期刊文献+
共找到3,623篇文章
< 1 2 182 >
每页显示 20 50 100
Intensity-Dependent Dipole Phase in High-Order Harmonic Interferometry
1
作者 王力 肖凡 +7 位作者 宋盼 陶文凯 孙旭 王家灿 郑志刚 赵晶 王小伟 赵增秀 《Chinese Physics Letters》 SCIE EI CAS CSCD 2023年第11期57-61,共5页
High-order harmonics are ideal probes to resolve the attosecond dynamics of strong-field recollision processes.An easy-to-implement phase mask is utilized to covert the Gaussian beam to TEM01 transverse electromagneti... High-order harmonics are ideal probes to resolve the attosecond dynamics of strong-field recollision processes.An easy-to-implement phase mask is utilized to covert the Gaussian beam to TEM01 transverse electromagnetic mode,allowing the realization of two-source interferometry of high-order harmonics.We experimentally measure the intensity dependence of dipole phase directly with high-order harmonic interferometry,in which the driving laser intensity can be precisely adjusted.The classical electron excursion simulations reproduce the experimental findings quite well,demonstrating that Coulomb potential plays subtle roles on movement of electrons for harmonics near the ionization threshold.This work is of great importance for precision measurements of ultrafast dynamics in strong-field physics. 展开更多
关键词 HARMONICS interferometry REALIZATION
原文传递
Achieving 1.2 fm/Hz^(1/2)Displacement Sensitivity with Laser Interferometry in Two-Dimensional Nanomechanical Resonators:Pathways towards Quantum-Noise-Limited Measurement at Room Temperature
2
作者 Jiankai Zhu Luming Wang +8 位作者 Jiaqi Wu Yachun Liang Fei Xiao Bo Xu Zejuan Zhang Xiulian Fan Yu Zhou Juan Xia Zenghui Wang 《Chinese Physics Letters》 SCIE EI CAS CSCD 2023年第3期74-81,共8页
Laser interferometry is an important technique for ultrasensitive detection of motion and displacement.We push the limit of laser interferometry through noise optimization and device engineering.The contribution of no... Laser interferometry is an important technique for ultrasensitive detection of motion and displacement.We push the limit of laser interferometry through noise optimization and device engineering.The contribution of noises other than shot noise is reduced from 92.6%to 62.4%,demonstrating the possibility towards shotnoise-limited measurement.Using noise thermometry,we quantify the laser heating effect and determine the range of laser power values for room-temperature measurements.With detailed analysis and optimization of signal transduction,we achieve 1.2 fm/Hz^(1/2)displacement measurement sensitivity at room temperature in twodimensional(2D)Ca Nb_(2)O_(6)nanomechanical resonators,the best value reported to date among all resonators based on 2D materials.Our work demonstrates a possible pathway towards quantum-noise-limited measurement at room temperature. 展开更多
关键词 noise interferometry optimization
原文传递
Wide-spectrum optical synthetic aperture imaging via spatial intensity interferometry
3
作者 Chunyan Chu Zhentao Liu +4 位作者 Mingliang Chen Xuehui Shao Guohai Situ Yuejin Zhao Shensheng Han 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第12期27-35,共9页
High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional... High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional long baseline amplitude interferometry is susceptible to uncontrollable phase fluctuations,and the technical difficulty increases rapidly as the wavelength decreases.The intensity interferometry inspired by HBT experiment is essentially insensitive to phase fluctuations,but suffers from a narrow spectral bandwidth which results in a lack of effective photons.In this study,we propose optical synthetic aperture imaging based on spatial intensity interferometry.This not only realizes diffraction-limited optical aperture synthesis in a single shot,but also enables imaging with a wide spectral bandwidth,which greatly improves the optical energy efficiency of intensity interferometry.And this method is insensitive to the optical path difference between the sub-apertures.Simulations and experiments present optical aperture synthesis diffraction-limited imaging through spatial intensity interferometry in a 100 nm spectral width of visible light,whose maximum optical path difference between the sub-apertures reaches 69λ.This technique is expected to provide a solution for optical aperture synthesis over kilometer-long baselines at optical wavelengths. 展开更多
关键词 optical synthetic aperture imaging ghost imaging intensity interferometry
下载PDF
Measurement of Shear Stress Acting on Flat Plate Using Oil Film Interferometry
4
作者 Takamitsu Fujino Masaki Endo +1 位作者 Hiromasa Suzuki Yoko Sakakibara 《Open Journal of Fluid Dynamics》 2023年第S1期217-225,共9页
Measurements of frictional resistance play an important role in engineering practice. There are several types of air resistance acting on an aircraft, for example. One of them, frictional resistance, accounts for half... Measurements of frictional resistance play an important role in engineering practice. There are several types of air resistance acting on an aircraft, for example. One of them, frictional resistance, accounts for half of the air resistance. Oil film interferometry is one of methods for measuring the frictional resistance. Oil dropped on an object is thinly stretched by the frictional resistance. The bright and dark fringe pattern is generated when monochromatic light is applied to the oil film. The gradient of the oil thickness decreases with the lapse of time, and thus the spacing between neighboring the dark lines increases. The rate at which the spacing increases is proportional to the frictional resistance. In this study, the frictional resistance acting on a small area on a plate was measured and compared with the theoretical value. As a result, these results qualitatively agree well with each other. 展开更多
关键词 Oil Film interferometry Fluid Friction Turbulent Flow Interference Fringes
下载PDF
Precise Three-Dimensional Deformation Retrieval in Large and Complex Deformation Areas via Integration of Offset-Based Unwrapping and Improved Multiple-Aperture SAR Interferometry:Application to the 2016 Kumamoto Earthquake 被引量:2
5
作者 Won-Kyung Baek Hyung-Sup Jung 《Engineering》 SCIE EI 2020年第8期927-935,共9页
Conventional synthetic aperture radar(SAR)interferometry(InSAR)has been successfully used to precisely measure surface deformation in the line-of-sight(LOS)direction,while multiple-aperture SAR interferometry(MAI)has ... Conventional synthetic aperture radar(SAR)interferometry(InSAR)has been successfully used to precisely measure surface deformation in the line-of-sight(LOS)direction,while multiple-aperture SAR interferometry(MAI)has provided precise surface deformation in the along-track(AT)direction.Integration of the InSAR and MAI methods enables precise measurement of the two-dimensional(2D)deformation from an interferometric pair;recently,the integration of ascending and descending pairs has allowed the observation of precise three-dimensional(3D)deformation.Precise 3D deformation measurement has been applied to better understand geological events such as earthquakes and volcanic eruptions.The surface deformation related to the 2016 Kumamoto earthquake was large and complex near the fault line;hence,precise 3D deformation retrieval had not yet been attempted.The objectives of this study were to①perform a feasibility test of precise 3D deformation retrieval in large and complex deformation areas through the integration of offset-based unwrapped and improved multiple-aperture SAR interferograms and②observe the 3D deformation field related to the 2016 Kumamoto earthquake,even near the fault lines.Two ascending pairs and one descending the Advanced Land Observing Satellite-2(ALOS-2)Phased Array-type L-band Synthetic Aperture Radar-2(PALSAR-2)pair were used for the 3D deformation retrieval.Eleven in situ Global Positioning System(GPS)measurements were used to validate the 3D deformation measurement accuracy.The achieved accuracy was approximately 2.96,3.75,and 2.86 cm in the east,north,and up directions,respectively.The results show the feasibility of precise 3D deformation measured through the integration of the improved methods,even in a case of large and complex deformation. 展开更多
关键词 Synthetic aperture radar(SAR) Conventional SAR interferometry(InSAR) Multiple-aperture SAR interferometry(MAI) ALOS-2 PALSAR-2 3D deformation retrieval 2016 Kumamoto earthquake
下载PDF
Comparison of four techniques for estimating temporal change of seismic velocity with passive image interferometry 被引量:6
6
作者 Zhikun Liu Jinli Huang Jiaojiao Li 《Earthquake Science》 CSCD 2010年第5期511-518,共8页
Passive image interferometry (PII) is becoming a powerful tool for detecting the temporal variations in the Earth's structure,which applies coda wave interferometry to the waveforms from the cross-correlation of s... Passive image interferometry (PII) is becoming a powerful tool for detecting the temporal variations in the Earth's structure,which applies coda wave interferometry to the waveforms from the cross-correlation of seismic ambient noise.There are four techniques for estimating temporal change of seismic velocity with PII:moving-window cross-correlation technique (MWCCT),moving-window cross-spectrum technique (MWCST),stretching technique (ST) and moving-window stretching technique (MWST).In this paper,we use the continuous seismic records from a typical station pair near the Wenchuan MS8.0 earthquake fault zone and generate three sets of waveforms by stacking cross-correlation function of ambient noise with different numbers of days,and then apply four techniques to processing the three sets of waveforms and compare their results.Our results indicate that the techniques based on moving-window (MWCCT,MWCST and MWST) are superior in detecting the change of seismic velocity,and the MWCST can give a better estimate of velocity change than the other moving-window techniques due to measurement error.We also investigate the clock errors and their influences on measuring velocity change.We find that when the clock errors are not very large,they have limited impact on the estimate of the velocity change with the moving-window techniques. 展开更多
关键词 passive image interferometry seismic ambient noise temporal variation moving-window cross-spectrum technique stretching technique
下载PDF
Monitoring elevation change of glaciers on Geladandong Mountain using Tan DEM-X SAR interferometry 被引量:5
7
作者 LIU Guang FAN Jing-hui +2 位作者 ZHAO Feng MAO Ke-biao DOU Chang-yong 《Journal of Mountain Science》 SCIE CSCD 2017年第5期859-869,共11页
Glaciers play an important role in the climate system. The elevation change of a glacier is an important parameter in studies of glacier dynamics. Only a few ground-based measurements of high mountain glaciers are ava... Glaciers play an important role in the climate system. The elevation change of a glacier is an important parameter in studies of glacier dynamics. Only a few ground-based measurements of high mountain glaciers are available due to their remoteness, high elevation, and complex topography. The acquisition from the German Tan DEM-X(Terra SAR-X add-on for Digital Elevation Measurement) SAR imaging configuration provides a reliable data sources for studying the elevation change of glaciers. In this study, the bistatic Tan DEM-X data that cover the Geladandong Mountain on the Tibetan Plateau were processed with SAR interferometry technique and the elevation changes of the mountain's glaciers during 2000–2014 were obtained. The results indicated that although distinct positive and negative elevation changes were found for different glacier tongues, the mean elevation change was about-0.14±0.26 m a-1. Geoscience Laser Altimeter System(GLAS) data were obtained for comparison and verification. The investigation using GLAS data demonstrated the efficacy of the proposed method in determining glacier elevation change. Thus, the presented approach is appropriate for monitoring glacier elevation change and it constitutes a valuable tool for studies of glacier dynamics. 展开更多
关键词 Elevation change Glacier Syntheticaperture radar interferometry Tan DEM-X Geladandongmountain Tibetan Plateau
原文传递
Imaging mantle transition zone discontinuities in southwest China from dense array ambient noise interferometry 被引量:2
8
作者 Jikun Feng Huajian Yao Weitao Wang 《Earthquake Science》 CSCD 2018年第5期301-310,共10页
Body waves retrieved from ambient noise cross-correlation functions(NCFs) have been reported by more and more recent studies in addition to the dominant recovered surface waves. And one of important applications of th... Body waves retrieved from ambient noise cross-correlation functions(NCFs) have been reported by more and more recent studies in addition to the dominant recovered surface waves. And one of important applications of these recovered body waves is to investigate the structure of discontinuities within the mantle transition zone(MTZ). In this study, clear body wave phases reflected from the MTZ discontinuities at 410 km and 660 km have been observed on the NCFs in the frequency band of 0.1–0.2 Hz from a dense regional seismic array in southwest China. The original timedomain reflected signals in the NCFs were first converted to the depth-domain NCFs based on a velocity model before they were further stacked spatially within different bins. Then the depth-domain NCFs were stacked to investigate the lateral variations of the MTZ discontinuities, that is, the 410-km and 660-km discontinuities. Our results exhibit a simple and lateral coherent P_(410) P phase and a much more complicated P_(660) P phase along two profiles, which are in good agreement with mineralogical prediction and recent receiver function studies in the same area. This interferometric method can provide stable reflected body wave phases mainly in the frequency band 0.1–0.2 Hz due to the secondary microseism noise, which can be potentially used for high-resolution mantle interface imaging. This approach is also a good complement to traditional imaging methods, such as receiver function imaging. 展开更多
关键词 ambient noise interferometry MANTLE transition zone 410-km and 660-km DISCONTINUITIES reflected body waves SOUTHWEST China
下载PDF
HIGH TEMPERATURE MOIRE INTERFEROMETRY TECHNOLOGY 被引量:1
9
作者 Zhang Guozhou Zhuang Yunan B. S. J. Kang, Wang Fengxiang(Faculty 403, Beijing University of Aeronautics andAstronautics, Beijing, China, 100083) 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1996年第4期289-295,共7页
HIGH TEMPERATURE MOIRE INTERFEROMETRY TECHNOLOGYZhangGuozhou;ZhuangYunan;B.S.J.Kang,WangFengxiang(Faculty403... HIGH TEMPERATURE MOIRE INTERFEROMETRY TECHNOLOGYZhangGuozhou;ZhuangYunan;B.S.J.Kang,WangFengxiang(Faculty403,BeijingUniversit... 展开更多
关键词 high temperature MOIRE interferometry DIFFRACTION GRATINGS (spectra)
下载PDF
Passive Seismic Structure Imaging of a Coal Mine by Ambient Noise Seismic Interferometry on a Dense Array 被引量:1
10
作者 GU Ning Michal CHAMARCZUK +2 位作者 GAO Ji Michal MALINOWSKI ZHANG Haijiang 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2021年第S01期37-39,共3页
Active source seismic method is generally used to image subsurface structures for resource exploration,including oil,gas and coal.Although it can provide highresolution subsurface structures,due to some economic and e... Active source seismic method is generally used to image subsurface structures for resource exploration,including oil,gas and coal.Although it can provide highresolution subsurface structures,due to some economic and environmental restrictions,it is not suitable in some cases.In recent 20 years,passive seismic survey based on ambient noise seismic interferometry(ANSI)has started to be widely used in imaging subsurface structures.In comparison,ANSI does not need active sources and can image subsurface structures at different depths as a lowcost alternative to active seismic exploration. 展开更多
关键词 passive seismic imaging ambient noise interferometry coal mine body wave
下载PDF
A Comparative Study of Ionospheric Correction on SAR Interferometry—A Case Study of L’Aquila Earthquake 被引量:2
11
作者 Yufang HE Wu ZHU +2 位作者 Yang LEI Qin ZHANG Zhenhong LI 《Journal of Geodesy and Geoinformation Science》 2022年第1期5-13,共9页
Synthetic Aperture Radar Interferometry(InSAR)has shown its potential on seismic deformation monitoring since it can achieve the accuracy of centimeter level or even the millimeter level.However,the irregular varietie... Synthetic Aperture Radar Interferometry(InSAR)has shown its potential on seismic deformation monitoring since it can achieve the accuracy of centimeter level or even the millimeter level.However,the irregular varieties of ionosphere can induce the additional phase delay on SAR interferometry,restricting its further application in high-precision deformation monitoring.Although several methods have been proposed to correct the ionospheric phase delay on SAR interferometry,the performances of them haven't been evaluated and compared.In this study,three commonly used methods,including polynomial fitting,azimuth offset and split-spectrum are applied to L'Aquila Earthquake to correct the ionospheric phase delay on two Phased Array type L-band Synthetic Aperture Radar(PALSAR)onboard the Advanced Land Observing Satellite-1(ALOS-1)images.The result indicates that these three methods can effectively correct the ionospheric phase delay error for SAR interferometry,where the standard deviations of the ionosphere-corrected results have decreased by almost a factor of 1.8 times for polynomial fitting method,4.2 times for azimuth offset method and 2.5 times for split-spectrum method,compared to those of the original phase.Furthermore,the result of the sliding distribution inversion of the seismic fault shows the best performance for split-spectrum method. 展开更多
关键词 SAR interferometry ionospheric effects split-spectrum method azimuth offset method performance evaluation
下载PDF
Optical System Design of Inter-Spacecraft Laser Interferometry Telescope 被引量:2
12
作者 Shengnan Chen Huilin Jiang +1 位作者 Chunyan Wang Zhe Chen 《Optics and Photonics Journal》 2019年第8期26-37,共12页
The fundamental measurement of space gravitational wave detection is to monitor the relative motion between pairs of freely falling test masses using heterodyne laser interferometry to a precision of 10 pm. The masses... The fundamental measurement of space gravitational wave detection is to monitor the relative motion between pairs of freely falling test masses using heterodyne laser interferometry to a precision of 10 pm. The masses under test are millions of kilometers apart. The inter-spacecraft laser interferometry telescope deliver laser efficiently from one spacecraft to another. It is an important component of the gravitational wave detection observatory. It needs to meet the requirements of large compression ratio, high image quality and extraordinary stray light suppression ability. Based on the primary aberration theory, the method of the large compression ratio off-axis four-mirror optical system design is explored. After optimization, the system has an entrance pupil of 200 mm, compression ratio of 40 times, scientific field of view (FOV) of ±8 μrad. To facilitate suppressing the stray light and delivering the laser beam to the back-end scientific interferometers, the intermediate images and the real exit pupils are spatially available. Over the full FOV, the maximum root mean square (RMS) wavefront error is less than 0.007λ, PV value is less than 0.03λ (λ = 1064 nm). The image quality is approached to the diffraction-limit. The TTL noise caused by the wavefront error of the telescope is analyzed. The TTL noise in the image space of 300 μrad range is less than 1 × 10-10 m whose slope is lower than 0.6 μm/rad, which is under the noise budget of the laser interferometer space antenna (LISA), satisfying the requirements of space gravitational wave detection. 展开更多
关键词 Laser interferometry TELESCOPE Optical Design GRAVITATIONAL WAVES
下载PDF
Ultraprecision intersatellite laser interferometry 被引量:3
13
作者 Min Ming Yingxin Luo +8 位作者 Yu-Rong Liang Jing-Yi Zhang Hui-Zong Duan Hao Yan Yuan-Ze Jiang Ling-Feng Lu Qin Xiao Zebing Zhou Hsien-Chi Yeh 《International Journal of Extreme Manufacturing》 2020年第2期54-66,共13页
Precision measurement tools are compulsory to reduce measurement errors or machining errors in the processes of calibration and manufacturing.The laser interferometer is one of the most important measurement tools inv... Precision measurement tools are compulsory to reduce measurement errors or machining errors in the processes of calibration and manufacturing.The laser interferometer is one of the most important measurement tools invented in the 20th century.Today,it is commonly used in ultraprecision machining and manufacturing,ultraprecision positioning control,and many noncontact optical sensing technologies.So far,the state-of-the-art laser interferometers are the ground-based gravitational-wave detectors,e.g.the Laser Interferometer Gravitational-wave Observatory(LIGO).The LIGO has reached the measurement quantum limit,and some quantum technologies with squeezed light are currently being tested in order to further decompress the noise level.In this paper,we focus on the laser interferometry developed for space-based gravitational-wave detection.The basic working principle and the current status of the key technologies of intersatellite laser interferometry are introduced and discussed in detail.The launch and operation of these large-scale,gravitational-wave detectors based on space-based laser interferometry is proposed for the 2030s. 展开更多
关键词 laser interferometry gravitational-wave detection inter-satellite laser ranging transponder laser interferometer
下载PDF
STUDY OF TRANSFORMATION PLASTICITY IN TETRAGONAL ZIRCONIA POLYCRYSTALS BY MOIRE INTERFEROMETRY
14
作者 卿新林 孙庆平 戴福隆 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1993年第4期329-336,共8页
Transformation plasticity in ceria-stabilized tetragonal zirconia poly-crystals due to the stress-induced tetragonal-to-monoclinic martensitic transforma-tion under tension and bending is studied by moire interferomet... Transformation plasticity in ceria-stabilized tetragonal zirconia poly-crystals due to the stress-induced tetragonal-to-monoclinic martensitic transforma-tion under tension and bending is studied by moire interferometry. The whole fringepatterns including u fields and v fields are acquired. According to these patterns, thedistributions of transformation plasticity in transformation zones are obtained, andthe phenomenon of plastic flow localization for transformation is revealed. The abovework provides a significant experimental foundation for establishing transformationconstitutive 展开更多
关键词 TRANSFORMATION PLASTICITY MOIRE interferometry PLASTIC flow localization.
下载PDF
Measurement of Liquid Concentration Fields Near Interface with Cocurrent Gas-Liquid Flow Absorption Using Holographic Interferometry
15
作者 郭莹 袁希钢 +1 位作者 曾爱武 余国琮 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2006年第6X期747-753,共7页
Real-time laser holographic interferometry was applied to measure liquid concentrations of CO2 in the vicinity of gas-liquid free interface under the conditions of cocurrent gas-liquid flow for absorption of CO2 by et... Real-time laser holographic interferometry was applied to measure liquid concentrations of CO2 in the vicinity of gas-liquid free interface under the conditions of cocurrent gas-liquid flow for absorption of CO2 by ethanol. The influences of the Reynolds number on the measurable interface concentration and on the film thickness were discussed. The results show that CO2 concentration decreases exponentially along the mass transfer direction, and the concentration gradient increases as Reynolds number of either liquid or gas increases. CO2 concentrations fluctuate slightly along the direction of flow; on the whole, there is an increase in CO2 concentration. The investiga- tion also demonstrated that film thickness decreases with the increase of Reynolds number of either of the two phases. Sherwood number representing the mass transfer coefficient was finally correlated as a function of the hy- drodynamic parameters and the physical properties. 展开更多
关键词 cocurrent GAS-LIQUID flow ABSORPTION concentration field NEAR INTERFACE HOLOGRAPHIC interferometry
下载PDF
THE APPLICATION OF MOIRE INTERFEROMETRY IN THE MEASUREMENT OF DISPLACEMENT FIELD AND STRAIN FIELD AT NOTCH-TIP AND CRACK-TIP
16
作者 韩金虎 毛天祥 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1991年第4期376-382,共7页
This paper presents the application of Moire interferometry in measuring the displacement andstrain field at notch-tip and crack-tip before and after crack propagation.The experiment is carried out using athree point ... This paper presents the application of Moire interferometry in measuring the displacement andstrain field at notch-tip and crack-tip before and after crack propagation.The experiment is carried out using athree point bending beam with a notch.The N_x and N_y fringe patterns representing displacement field,and theΔN_x/Δx and ΔN_y/Δy fringe patterns representing the strain field are obtained.The sensitivity of the meas-ured displacement is 0.417μm per fringe order.The displacement and strain distribution along the sectionx=0 have been worked out according to N_x and N_y fringe patterns. 展开更多
关键词 MOIRE interferometry displacement FIELD strain FIELD NECKING zone
下载PDF
MEASURING DISPLACEMENT FIELDS OF CURVED SURFACE BY MOIRE INTERFEROMETRY OF PARTIAL COHERENT LIGHT
17
作者 钟国成 王兵 +1 位作者 蒋小林 戴福隆 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1993年第2期177-184,共8页
This paper presents a method to measure the in-plane displacement fields of curved surface bymoire interferometry of partial coherent light.The method has the following advantages:simple opticalsystem,no requirement o... This paper presents a method to measure the in-plane displacement fields of curved surface bymoire interferometry of partial coherent light.The method has the following advantages:simple opticalsystem,no requirement on vibration isolation,high sensitivity,large measuring range,high contrast of interference fringes and availability to in-situ structural testing.The present paper also gives theoretical analysis ofthe method and the formulas of light intensity and displacement field,and introduces a replication techniqueto form a high frequency reflectance grating on the curved surface.The experiments achieved the measurementof the surface displacement field of a cylindrical shell—the simultaneous circumferential,axial and 45°displacement fields.The torsional test data for surface displacement of a circular bar agree well with thetheoretical result. 展开更多
关键词 MOIRE interferometry partial COHERENT light CIRCUMFERENTIAL DISPLACEMENT AXIAL DISPLACEMENT
下载PDF
Pitch Shift in Exsomatized Cochlea Observed by Laser Interferometry
18
作者 龙长才 沈涛 +1 位作者 张艳平 骆琳 《Chinese Physics Letters》 SCIE CAS CSCD 2019年第2期19-22,共4页
Pitch is one of the most important auditory perception characteristics of sound; however, the mechanism underlying the pitch perception of sound is unclear. Although theoretical researches have suggested that percepti... Pitch is one of the most important auditory perception characteristics of sound; however, the mechanism underlying the pitch perception of sound is unclear. Although theoretical researches have suggested that perception of virtual pitch is connected with physics in cochlea of inner ear, there is no direct experimental observation of virtual pitch processing in the cochlea. By laser interferometry, we observe shift phenomena of virtual pitch in basilar membrane vibration of exsomatized cochlea, which is consistent with perceptual pitch shift observed in psychoacoustic experiments. This means that the complex mechanical vibration of basilar membrane in cochlea plays an important role in pitch information processing during hearing. 展开更多
关键词 In PITCH SHIFT in Exsomatized COCHLEA OBSERVED by LASER interferometry
原文传递
THE THREE-DIMENSIONAL ANALYSIS OF THE SELF-VIBRATIONAL CHARACTERI-STICS OF THE 2050MM HOT-STRIP MILL HOUSING BY MEANS OF LASER HOLOGRAPHIC INTERFEROMETRY AND FINITE ELEMENT METHOD
19
作者 刘慰俭 蒋维兴 瞿志豪 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1991年第3期291-300,共10页
According to the theory of similarity,a three-dimensional simulation study on the self-vibrational characteristics of the2050mm hot-strip finishing mill housing at Baoshan Ironand Steel Complex has been carried out.Th... According to the theory of similarity,a three-dimensional simulation study on the self-vibrational characteristics of the2050mm hot-strip finishing mill housing at Baoshan Ironand Steel Complex has been carried out.The analysis of the main vibrational modes of thefirst three orders has also been done by means of holographic interferometry.In addition,the authors have carried out the numerical analysis of finite elements in three dimensions.The comparison of the results of both analyses(simulation analysis and numerical analysisof finite element)shows that they are consistent. 展开更多
关键词 self-vibration characteristic HOLOGRAPHIC interferometry numerical ANALYSIS Inherent frequency. Inherent vibrationai mode
下载PDF
Diagnosis of the surface morphology of laser-ablated materials using the weightedDCT approach in laser speckle interferometry for application to plasma facing materials
20
作者 李元博 王宏北 +3 位作者 崔晓倩 李树华 赵栋烨 丁洪斌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第9期122-131,共10页
To implement on-line, real-time monitoring for the surface morphology of Plasma-Facing Materials(PFMs) in tokamak, we developed a Laser Speckle Interferometry measurement approach. A laser ablation method was used to ... To implement on-line, real-time monitoring for the surface morphology of Plasma-Facing Materials(PFMs) in tokamak, we developed a Laser Speckle Interferometry measurement approach. A laser ablation method was used to simulate the erosion process during Plasma-Wall Interactions in a tokamak. In the present investigation, we evaluated the results of laser ablation morphology changes on the surface of Mo material reconstructed by four different approaches(Flood-fill, Quality-guided, Discrete Cosine Transform(DCT) and Weighted-DCT). The morphology results measured by the weighted-DCT approach are very close to the measurement results from confocal microscopy with an average error rate within 7%. It is verified that the weighted-DCT algorithm has high accuracy and can efficiently reduce the influence of noise pollution coming from laser ablation, which is used as a proxy for erosion from plasma wall interaction. Additionally, the CPU computer time has been shortened. This is of great significance for the real-time monitoring of PFMs’ morphology in the Experimental Advanced Superconducting Tokamak(EAST) in the future. 展开更多
关键词 TOKAMAK fusion plasma-wall INTERACTIONS LASER SPECKLE interferometry topographical reconstruction algorithms
下载PDF
上一页 1 2 182 下一页 到第
使用帮助 返回顶部