期刊文献+
共找到4,385篇文章
< 1 2 220 >
每页显示 20 50 100
Flapless one-knot suture:a novel surgical technique for transscleral fixation of C-loop intraocular lenses
1
作者 Qing-Qing Long Bao-Jiang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期736-742,共7页
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv... AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique. 展开更多
关键词 C-loop intraocular lens implantation lens dislocation transscleral fixation four-haptics intraocular lens
原文传递
Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery
2
作者 Lara Buhl Julian Langer +3 位作者 Stefan Kassumeh Thomas C.Kreutzer Wolfgang J.Mayer Siegfried G.Priglinger 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1231-1236,共6页
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL... AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months. 展开更多
关键词 combined phaco-vitrectomy toric intraocular lens rotational stability corneal astigmatism CATARACT vitreoretinal disease
原文传递
Pupillary capture following sutureless scleral-fixated intraocular lens in children with Marfan syndrome
3
作者 Dong-Mei Qi Shu-Jia Huo Tao Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1789-1793,共5页
AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxat... AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxation due to MFS.These children underwent lensectomy,anterior vitrectomy,and sutureless SFIOL.According to the position of placement of intraocular lens(IOL)haptics,two study groups were reviewed for best corrected visual acuity(BCVA)and postoperative complications:group A,14 eyes with haptics fixated at 2.0 mm from the limbus;group B,12 eyes with the haptics fixated at 2.5 mm from the limbus.RESULTS:The mean axial length for all patients was 25.66±2.35 mm.Postoperative BCVA in logMAR were significant improved in both groups(0.77±0.32 to 0.17±0.12 in group A,0.66±0.25 to 0.24±0.12 in group B,both P<0.001)while no significant difference between two groups(P>0.05).Pupillary capture was main postoperative complication,occurring between 3d and 18mo.It occurred in 7 eyes in group A and one eye in group B(P=0.02).CONCLUSION:Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS.Pupillary capture is the main postoperative complication.Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture. 展开更多
关键词 Marfan syndrome sutureless scleral-fixated intraocular lens pupillary capture CHILDREN
原文传递
IOL Master 700与Lenstar LS900对高度近视合并白内障患者术前生物测量及人工晶状体计算的比较
4
作者 陶露莎 高铃 +3 位作者 喻娟 冯英 陈爽 吴敏 《国际眼科杂志》 CAS 2024年第4期612-617,共6页
目的:比较IOL Master 700与Lenstar LS900对高度近视合并白内障患者术前眼生物测量的差异性、相关性、一致性及人工晶状体(IOL)度数计算的准确性。方法:回顾性研究。收集2021-03/2023-03于陆军特色医学中心眼科行白内障超声乳化联合IOL... 目的:比较IOL Master 700与Lenstar LS900对高度近视合并白内障患者术前眼生物测量的差异性、相关性、一致性及人工晶状体(IOL)度数计算的准确性。方法:回顾性研究。收集2021-03/2023-03于陆军特色医学中心眼科行白内障超声乳化联合IOL植入手术的高度近视合并白内障患者136例136眼,平均年龄57.38±8.08岁。根据眼轴长度(AL)将患者分为3组:A组(26 mm≤AL≤28 mm)41眼,B组(28 mm30 mm)52眼。术前分别使用两种仪器测量AL、平均角膜曲率(Km)、前房深度(ACD)、晶状体厚度(LT)和白到白距离(WTW)。所有患者均采用Barrett UniversalⅡ公式计算IOL度数,个性化选择适宜的预留屈光度,比较两种仪器的预测屈光误差(PE)和绝对屈光误差(AE)。结果:三组患者中Lenstar LS900测量的AL和ACD均大于IOL Master 700测量值(均P<0.05),且两种仪器测量AL的平均差值C组>B组>A组。两种仪器测量LT、Km与WTW值均无差异(均P>0.05)。两种仪器所得各组生物参数均具有正相关性(均r>0.9,P<0.05)且一致性较好(95%LoA范围较窄)。两种仪器计算的AE无差异(P>0.05),但IOL Master 700计算的PE小于Lenstar LS900(P<0.05),且前者远视偏移百分比更低。结论:在高度近视合并白内障患者中,Lenstar LS900测量AL值大于IOL Master 700,且该差异随着AL的增加而增大,两种仪器对IOL的计算均具有良好的预测性,但IOL Master 700术后屈光误差更小,远视偏移百分比更低。 展开更多
关键词 IOL Master 700 lenstar LS900 高度近视 白内障 生物测量 眼轴 人工晶状体 Barrett UniversalⅡ
下载PDF
Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths 被引量:16
5
作者 Jia-Kang Wang Shu-Wen Chang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第2期150-154,共5页
AIM: To investigate the predictability of intraocular lens (IOL) power calculation using the IOLMaster and different IOL power calculation formulas in eyes with various axial length (AL). METHODS: Patients were includ... AIM: To investigate the predictability of intraocular lens (IOL) power calculation using the IOLMaster and different IOL power calculation formulas in eyes with various axial length (AL). METHODS: Patients were included who underwent uneventful phacoemulsification with IOL implantation in the Department of Ophthalmology, Far Eastern Memorial Hospital, Taipei, Taiwan, China from February 2007 to January 2009. Preoperative AL and keratometric values (Ks) were measured by IOLMaster optical biometry. Patients were divided into 3 groups based on AL less than 22mm (Group 1), 22-26mm (Group 2), and more than 26mm (Group 3). The power of the implanted IOL was used to calculate the predicted postoperative spherical equivalence (SE) by various formulas: the Haigis, Hoffer Q, Holladay 1, and SRK/T. The predictive accuracy of each formula was analyzed by comparing the difference between the actual and predicted postoperative SE (MedAE, median absolute error). All the patients had follow-up periods exceeding 3 months. RESULTS: Totally, there were 200 eyes (33 eyes in Group 1, 92 eyes in Group 2, 75 eyes in Group 3). In all patients, the Haigis had the significantly lower MedAE generated by the other formulas (P<0.05). In Group 1 to 3, the MedAE calculated by the Haigis was either significantly lower or comparable to those calculated by the other formulas.CONCLUSION: Compared with other formulas using IOLMaster biometric data, the Haigis formula yields superior refractive results in eyes with various AL. 展开更多
关键词 intraocular lens OPTICAL BIOMETRY calculation formula
原文传递
Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia 被引量:14
6
作者 Isil Bahar Sayman Muslubas Baran Kandemir +2 位作者 Ayse Yesim Aydin Oral Suleyman Kugu Metin Dastan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期376-380,共5页
AIM:To report the long-term vision-threatening complications in patients who underwent phakic intraocular lens(pIOLs)implantation for high myopia.METHODS:Thisstudywasdesignedfromaconsecutive series of phakic intraocul... AIM:To report the long-term vision-threatening complications in patients who underwent phakic intraocular lens(pIOLs)implantation for high myopia.METHODS:Thisstudywasdesignedfromaconsecutive series of phakic intraocular lens complication and corrective surgeries.Sixteen eyes of 13 patients had implantation of phakic intraocular lens for correction high myopia and developed serious complications have been included in this study.The mean age of patients was 38.6±6.35y(range 32-50y)and the mean time of history of pIOL implantation for high myopia was 6±2y(range 2-10y).Before corrective surgery,best spectaclecorrective visual acuity(BSCVA)ranged from perception to 20/200 in the eyes in which severe complications occurred.RESULTS:Corneal decompensation occurred in 12eyes of 9 high myopic patients after anterior chamber pIOL implantation.Rhegmatogenous retinal detachment(RRD)occurred in 4 eyes of 4 high myopic patients following anterior chamber and posterior chamber pIOL implantation.Patients with corneal decompensation,had combined procedures consisting of pIOL removal and penetrating keratoplasty(PKP).Removals of pIOL,phacoemulsification and pars plana vitrectomy(PPV)with silicone oil tamponade were performed in patients with RRD.After corrective surgeries,all patients but one(P+,patient 2,right eye)achieved moderate BSCVA ranged from 20/200 to 20/50 at the last visit.CONCLUSION:Phakic IOLs may be effective for thecorrection of high myopia.Although these IOLs may have severe complications and it affects safety and efficacy of this surgery.As seen here,corneal decompensation and rhegmatogenous retinal detachment are possible postoperative vision-threatening complications of phakic IOLs.Patients must be carefully examined before and after surgery for possible endothelial cell loss and vitreoretinal problems. 展开更多
关键词 PHAKIC intraocular lens high MYOPIA COMPLICATIONS corneal DECOMPENSATION rhegmatogenous retinal DETACHMENT
原文传递
High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric,aberration correcting monofocal intraocular lens 被引量:14
7
作者 Florian T A Kretz Tamer Tandogan +1 位作者 Ramin Khoramnia Gerd U Auffarth 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期736-741,共6页
·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twent... ·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twenty-one patients(34 eyes) aged 50 to83 y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL(Tecnis ZCB00,Abbott Medical Optics). Three months after surgery they were examined for uncorrected(UDVA) and corrected distance visual acuity(CDVA), contrast sensitivity(CS)under photopic and mesopic conditions with and without glare source, ocular high order aberrations(HOA, Zywave II) and retinal straylight(C-Quant).· RESULTS: Postoperatively, patients achieved a postoperative CDVA of 0.0 log MAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27(primary coma components) and-0.04 ±0.16(spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed(P ≥0.28).· CONCLUSION: The implantation of an aspherical aberration correcting monofocal IOL after cataractsurgery resulted in very low residual higher order aberration(HOA) and normal straylight. 展开更多
关键词 cataract ABERRATIONS intraocular lens
原文传递
Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens 被引量:8
8
作者 Xian-Hui Gong Qin-Xiang Zheng +4 位作者 Na Wang Ding Chen Juan Zhao Jin Li and Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期323-328,共6页
AIM:To compare the visual and optical performance of eyes with different corneal spherical aberration(SA) implanted with spherical aberration-free intraocular lens(IOLs).· METHODS:Thirty-six patients with differe... AIM:To compare the visual and optical performance of eyes with different corneal spherical aberration(SA) implanted with spherical aberration-free intraocular lens(IOLs).· METHODS:Thirty-six patients with different corneal SA had phacoemulsification with implantation of spherical aberration-free IOLs.Patients were divided into 3 groups according to the value of preoperative corneal SA.Eyes with corneal SA <0.10μm were assigned to group A,those with 0.10 ≤corneal SA <0.20μm to Group B,and those with 0.20≤corneal SA <0.35μm to Group C.Best-corrected visual acuity(BCVA),contrast sensitivity,corneal SA,total ocular aberrations,and depth of focus were recorded 3 months postoperatively.Distance-corrected near and intermediate visual acuity was studied to measure depth of focus.· RESULTS:BCVA and contrast sensitivity were similar between groups.There were no significant differences in distance-corrected near or intermediate visual acuity.Corneal SA was similar before and 3 months after surgery in the 3 groups.With a 5.0mm pupil diameter,root mean square values for total ocular higher-order aberrations(HOAs) were lower in groups A and B than in group C.Total ocular SA was lower in group A than in groups B and C.SA was also lower in group B than in group C.Coma and trefoil were similar between the groups.· CONCLUSION:Implantation of spherical aberration-free IOLs in eyes with different corneal SA results in similar visual performance at BCVA,contrast sensitivity and depth of focus. 展开更多
关键词 spherical aberration-free intraocular lens sherical ABERRATION contrast sensitivity CATARACT
原文传递
Clinical study of customized aspherical intraocular lens implants 被引量:8
9
作者 Lie-Xi Jia Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第5期816-821,共6页
AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assign... AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assigned lenses.METHODS:A total of 124 eyes of 124 patients with age-related cataracts were placed in experimental group and a group receiving randomly assigned(RA) lenses.The experimental group was undergone Pentacam corneal spherical aberration measurement before surgery; the targeted range for residual total spherical aberration after surgery was set to 0-0.3 μm. Patients with a corneal spherical aberration <0.3 μm were implanted with a zero-spherical aberration advanced optics(AO) aspherical IOL and patients with an aberration ≥0.3 μm received a Tecnis Z9003 aspherical lens in experimental group. RA patients were randomly implanted with an AO lens or a Tecnis Z9003 lens. Three months after surgery total spherical aberration, photopic/mesopic contrast sensitivities, photopic/mesopic with glare contrast sensitivities, and logMAR vision were measured.RESULTS:Statistical analysis on logMAR vision showed no significant difference between two groups(P =0.413). The post-surgical total spherical aberration was 0.126 ±0.097 μm and 0.152 ±0.151 μm in the experimental and RA groups, respectively(P =0.12). The mesopic contrast sensitivities at spatial frequencies of 6,12 and 18 c/d in the experimental group were significantly higher than of the RA group(P =0.00; P =0.04;P =0.02). The mesopic with glare contrast sensitivity in the experimental group at a spatial frequency of 18 c/d was also significantly higher vs the RA group(P =0.01).CONCLUSION:Pre-surgical corneal spherical aberration measurement in cataract patients followed bycustomized selection of aspherical IOL implants improved mesopic contrast sensitivities at high spatial frequencies, and thus is a superior strategy compared to the random selection of aspherical intraocular lens implants. 展开更多
关键词 intraocular lens CATARACT extraction CORNEAL WAVEFRONT ABERRATION mesopic VISION night VISION
原文传递
Posterior chamber phakic intraocular lens implantation for high myopia 被引量:7
10
作者 Yan Ju Xiao-Wei Gao Bing Ren 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第6期831-835,共5页
AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implanta... AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove. 展开更多
关键词 PHAKIC intraocular lens lens IMPLANTATION MYOPIA
原文传递
Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses:a meta-analysis 被引量:6
11
作者 Jian-Ping Liu Fan Zhang +2 位作者 Jiang-Yue Zhao Li-Wei Ma Jin-Song Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期690-695,共6页
AIM:To assess the visual outcomes of aspheric multifocal intraocular lenses(IOLs) compared with spherical multifocal IOL after cataract surgery.METHODS:Potential prospective controlled trials that comparing aspheric m... AIM:To assess the visual outcomes of aspheric multifocal intraocular lenses(IOLs) compared with spherical multifocal IOL after cataract surgery.METHODS:Potential prospective controlled trials that comparing aspheric multifocal IOL implantation with spherical multifocal IOL group were extracted from the computer database.The statistical analysis was carried out using Stata 10 software.Standardized mean differences with 95% confidence intervals(CIs) were calculated for continuous variables.The pooled estimates were computed in the use of a random-effects model. RESULTS:A systematic review identified five prospective nonrandomized controlled trials,including 178 aspheric multifocal IOL and 164 spherical multifocal IOL.There was no significant difference in uncorrected distance visual acuity(95%CI,-0.248 to 0.152;P=0.641) and uncorrected near visual acuity(95% CI,-0.210 to 0.428;P=0.504) between aspheric multifocal IOL and spherical multifocal IOL.Statistically significant differences were detected less spherical aberration in aspheric multifocal IOL(95% CI,-1.111 to-0.472;P<0.001) when compared to spherical multifocal IOL.Spherical multifocal IOL showed a greater higher order aberration compared to the aspheric multifocal IOL(95% CI,-1.024 to-0.293;P<0.001).Sensitivity analysis suggested that the results were relatively reliable. CONCLUSION:The overall findings indicated that aspheric multifocal IOL and spherical multifocal IOL provided similar visual acuity at near and distance.Patients implanted with aspheric multifocal IOL had less spherical aberration and higher order aberration than patients with spherical multifocal IOL.Further well organized,prospective controlled trials involving larger patient numbers are needed. 展开更多
关键词 aspheric MULTIFOCAL intraocular lens uncorrected near visual ACUITY uncorrected distance visual ACUITY SPHERICAL MULTIFOCAL intraocular lens higher order ABERRATION meta-analysis
原文传递
Optical quality of toric intraocular lens implantation in cataract surgery 被引量:7
12
作者 Xian-Wen Xiao Jing Hao +1 位作者 Hong Zhang Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第1期66-71,共6页
AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D ... AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P >0.05), except the residual refractive cylinder(P <0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery. 展开更多
关键词 optical QUALITY analysis system TORIC intraocular lens ASTIGMATISM
原文传递
Comparison of Artisan iris-claw intraocular lens implantation and posterior chamber intraocular lens sulcus fixation for aphakic eyes 被引量:7
13
作者 He Teng Hong Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期283-287,共5页
AIM:To compare the efficacy and complications of Artisan iris-claw intraocular lens(IOL)implantation and posterior chamber IOL sulcus fixation for the treatment of aphakic eyes without capsular support after vitrectom... AIM:To compare the efficacy and complications of Artisan iris-claw intraocular lens(IOL)implantation and posterior chamber IOL sulcus fixation for the treatment of aphakic eyes without capsular support after vitrectomy.METHODS:A prospective study of 45 cases was conducted.Forty-five eyes without sufficient lens capsule support following pars plana vitrectomy(PPV)combined lens extraction were divided into two groups.Group A:25 eyes received Artisan iris-claw IOL implantation.Group B:20 eyes received posterior chamber IOL sulcus fixation.The corrected distance visual acuity(CDVA)and intraocular pressure(IOP),corneal endothelial cell loss rate,surgical time and complications were compared between the two groups.Pigment changes of trabecular meshwork and anterior chamber depths were measured at each time point in Artisan group.RESULTS:The mean surgical time of Artisan group was significantly shorter(P<0.05).No statistically significant difference in endothelial cell loss rate was noted between two groups at any time point(P>0.05).CDVA of Artian group was better than that of the sulcus fixation group 1d after surgery(P<0.05)and there was no statistically significant difference 1 and 3mo after surgery(P>0.05).Mean IOP showed no significant differences between groups before and after surgery.The postoperative complications of Artisan group were anterior uveitis,iris depigmentation,pupillary distortion and spontaneous lens dislocation.The complications of sulcus fixation group include choroidal detachment,intraocular haemorrhage,tilt of IOL optic part and retinal detachment.CONCLUSION:Secondary Artisan IOL implantation canbe performed less invasively and in a shorter surgical time period with earlier visual recovery after surgery compared to transscleral suturing fixation of an IOL.This technique is an effective and safe procedure.It is a promising option for the treatment of aphakic eyes without capsular support after vitrectomy. 展开更多
关键词 iris-claw intraocular lens aphakic eye VITRECTOMY
原文传递
Comparison of design of intraocular lens versus the material for PCO prevention 被引量:5
14
作者 Sarbani Hazra Himangshu Palui Geeta K Vemuganti 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期59-63,共5页
AIM: To evaluate the influence of different intraocular lens(IOL) designs made of PMMA on posterior capsular opacification(PCO) and compare with foldable designs.· METHODS: Phacoemulsification and IOL implantatio... AIM: To evaluate the influence of different intraocular lens(IOL) designs made of PMMA on posterior capsular opacification(PCO) and compare with foldable designs.· METHODS: Phacoemulsification and IOL implantation was done in one eye of 24 New Zealand White rabbits, with IOL of two different designs (Square edged or round edge) and two different materials(PMMA or HEMA). After three months, the animals were sacrificed and enucleated. Evaluation of PCO included posterior view, migration of anterior capsular epithelial cells to the posterior capsule following epithelial-mesenchymal transition were assessed by staining the histological sections of posterior capsule by hematoxylin-eosin(HE) and Periodic acid- Schiff (PAS). The IOLs were extracted and stained with HE to evaluate the presence of adherent cells on the lens surface. · RESULTS: PCO was highest with round edged rigid lens. There was no significant difference in the PCO between the square edged PMMA and square edged foldable lens.· CONCLUSION: It is the design of the IOL not the material that offers protection on PCO formation. 展开更多
关键词 DESIGN MATERIAL of intraocular lens posterior CAPSULAR OPACIFICATION
原文传递
Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes 被引量:5
15
作者 Jia-Qing Zhang Xu-Yuan Zou +3 位作者 Dan-Ying Zheng Wei-Rong Chen Ao Sun Li-Xia Luo 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第6期943-948,共6页
AIM: To evaluate the effect of different lens constant optimization methods on the accuracy of intraocular lens(IOL) power calculation formulas for highly myopic eyes.METHODS: This study comprised 108 eyes of 94 conse... AIM: To evaluate the effect of different lens constant optimization methods on the accuracy of intraocular lens(IOL) power calculation formulas for highly myopic eyes.METHODS: This study comprised 108 eyes of 94 consecutive patients with axial length(AL) over 26 mm undergoing phacoemulsification and implantation of a Rayner(Hove, UK) 920H IOL. Formulas were evaluated using the following lens constants: manufacturer’s lens constant, User Group for Laser Interference Biometry(ULIB) constant, and optimized constant for long eyes. Results were compared with Barrett Universal II formula, original Wang-Koch AL adjustment method, and modified Wang-Koch AL adjustment method. The outcomes assessed were mean absolute error(MAE) and percentage of eyes with IOL prediction errors within ±0.25, ±0.50, and ±1.0 diopter(D). The nonparametric method, Friedman test, was used to compare MAE performance among constants.RESULTS: Optimized constants could significantly reduce the MAE of SRK/T, Hoffer Q, and Holladay 1 formulas compared with manufacturer’s lens constant, whereas the percentage of eyes with IOL prediction errors within ±0.25, ±0.50, and ±1.0 D had no statistically significant differences. Optimized lens constant for long eyes alone showed non-significant refractive advantages over the ULIB constant. Barrett Universal II formula and formulas with AL adjustment showed significantly higher accuracy in highly myopic eyes(P<0.001). CONCLUSION: Lens constant optimization for the subset of long eyes reduces the refractive error only to a limited extent for highly myopic eyes. 展开更多
关键词 high MYOPIA CATARACT intraocular lens power lens constant OPTIMIZATION prediction error
原文传递
Contrast visual acuity after multifocal intraocular lens implantation: aspheric versus spherical design 被引量:5
16
作者 Jun-Hua Li Yi-Fan Feng +2 位作者 Yun-E Zhao Yin-Ying Zhao Lei Lin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第1期100-103,共4页
AIM: To evaluate contrast visual acuity(CVA) after implantation of an aspheric apodized diffractive intraocular lens(IOL) or a spherical apodized diffractive IOL in cataract surgery. ·METHODS: This prospective ra... AIM: To evaluate contrast visual acuity(CVA) after implantation of an aspheric apodized diffractive intraocular lens(IOL) or a spherical apodized diffractive IOL in cataract surgery. ·METHODS: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL(30 eyes) and a spherical AcrySof ReSTOR SN60D3 IOL(30 eyes). CVA with best distance correction was measured at 4 contrast levels(100%,25%,10% and 5%) under 3 levels of chart luminance [250,85 and 25 candelas per square meter(cd/m2)] using a multi-functional visual acuity tester(MFVA-100). ·RESULTS: At 12 months after surgery,there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2(P100% =0.875 and P25% =0.057) and 85cd/m2(P100% =0.198 and P25% =0.193) between the aspheric group and the spherical group. However,the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2(P10% =0.042 and P5% = 0.007) and 85cd/m2(P10% =0.002 and P5%=0.039). Under the luminance level of 25cd/m 2,no significant differences was found in the 100% CVA between the 2 group(P100% = 0.245),while aspheric group had better visual acuity in the remaining 3 contracts(P25% =0.023,P10% =0.026 and P5% = 0.002,respectively). ·CONCULSION: The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL. 展开更多
关键词 CATARACT surgery intraocular lens CONTRAST sensitivity visual ACUITY
原文传递
Clinical evaluation of two multifocal intraocular lens implantation patterns 被引量:5
17
作者 Hao-Tian Lin Wei-Rong Chen +2 位作者 Zhao-Feng Ding Wan Chen and Chang-Rui Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期76-83,共8页
AIM:To evaluate the visual outcomes and patient satisfaction of two multifocal intraocular lens implantation patterns,with the decision between the two patterns being guided by the patients' choice of visual zones... AIM:To evaluate the visual outcomes and patient satisfaction of two multifocal intraocular lens implantation patterns,with the decision between the two patterns being guided by the patients' choice of visual zones that best suited their lifestyle,or lifestyle zones.· METHODS:This is a prospective non-randomized comparative study.The lifestyle zones of 32 consecutive age-related cataract patients (64 eyes) were investigated individually to guide the surgical decision between two multifocal intraocular lens implantation patterns.The first group (MIX) received a combined implantation of a ReZoom NXG1 lens in the dominant eye and a Tecnis ZM900 lens in the other eye.The second group (MATCH) received bilateral ReZoom NXG1 lenses.One year postoperatively,the patients were assessed for binocular uncorrected visual acuity,reading visual acuity,reading speed and depth of focus under different luminance and were surveyed for visual disturbances,satisfaction and complete spectacle independence.· RESULTS:According to the determination of lifestyle zones,18 and 14 patients were included in the MIX and MATCH groups,respectively.One year postoperatively,each of the patients exhibited positive visual outcomes and lifestyle satisfaction,although there were still some differences between the two groups.Generally,patients in the MATCH group had better distance visual acuity than those in the MIX group.In contrast,patients in the MIX group had better near visual acuity,better reading acuity and better reading speed than those in the MATCH group.Between the two groups,there was no clear difference in intermediate visual acuity,and the depths of focus between the two groups were approximately equal.The results of the mean NEI-RQL-42 questionnaire score,overall satisfaction,and complete spectacle independence did not differ between the two groups.· CONCLUSION:Different multifocal intraocular lenses implantation patterns can have differing advantages and disadvantages;however,the best results with respect to visual outcome and patient satisfaction can be achieved by taking individual lifestyle zones into account. 展开更多
关键词 intraocular lens visual OUTCOMES PATIENT SATISFACTION
原文传递
Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison 被引量:5
18
作者 Pan-Pan Ye Xia Li Ke Yao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第3期300-306,共7页
AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·MET... AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best - corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractivepower than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. 展开更多
关键词 intraocular lens ABERRATION visual ACUITY MULTIFOCAL
原文传递
Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics 被引量:5
19
作者 Mohammad Taher Rajabi Sara Korouji +4 位作者 Mahgol Farjadnia Mohammad Naderan Mohammad Bagher Rajabi Bahram Khosravi Seyed Mehdi Tabatabaie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期565-568,共4页
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty... AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses. 展开更多
关键词 aspherical lenses higher order ABERRATIONS CATARACT intraocular lens
原文传递
Intraocular lens optic capture in pediatric cataract surgery 被引量:5
20
作者 Ying-Bin Xie Mei-Yu Ren +1 位作者 Qi Wang Li-Hua Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第8期1403-1410,共8页
Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended co... Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended considerable effort into preventing and mitigating PCO. The intraocular lens(IOL) optic capture technique has been used for the prevention of PCO after pediatric cataract surgery for more than 20 y, but there is still no professional consensus. However, recent research has shown encouraging results. The IOL optic capture technique can be performed without anterior vitrectomy to prevent PCO, even in younger children. The type and characteristics of IOLs used for optic capture technique, the location of IOL and the complications of IOL optic capture in children are here reviewed. 展开更多
关键词 CATARACT PEDIATRIC lens intraocular surgery
原文传递
上一页 1 2 220 下一页 到第
使用帮助 返回顶部