The percent ammonia nitrogen was determined in Passaic River waste water using Ion-Selective Electrode EPA Method 350.3. The intelligent ammonia sensor integrates ammonia electrode, pH electrode and Ammonia Ion electr...The percent ammonia nitrogen was determined in Passaic River waste water using Ion-Selective Electrode EPA Method 350.3. The intelligent ammonia sensor integrates ammonia electrode, pH electrode and Ammonia Ion electrode together to realize the in situ detection of ammonia. The test results have shown that the sensor is easy operation, low cost and no pollution. The ammonia is determined potentiometrically using an ammonia ion selective electrode and a pH/mV meter, having an expanded millivolt scale. The ammonia selective electrode uses a hydrophobic gas-permeable membrane to separate the sample solution from an electrode internal solution of ammonium chloride. Dissolved ammonia is converted to NH<sub>3</sub> gas by raising the pH to above 11.0 with a strong base. NH<sub>3</sub> gas diffuses the membrane and changes the internal solution pH that is sensed by the electrode. In single laboratory test results have been found 1.001 NH<sub>3</sub>-/L and 0.897 mg NH<sub>3</sub>-N/L, recoveries were 77.3% and 83.1%, respectively.展开更多
Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health a...Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health and help in normal mineralization of bone and formation of dental enamel. The determination of fluoride in some species was performed by using fluoride ion-selective electrode by direct measurement and standard addition method. The concentration of fluoride ion was determined in drinking water (from different place at Kathmandu), toothpaste, various brand of tea and coffees. The range of fluoride concentration in water sample was 0.16 to 0.39 mg/l, tea and coffee samples were 0.011 to 0.084 mg/l and its value of toothpaste was 0.026 to 0.75 mg/l. The concentration of fluoride ion obtain from different sample was compared with the legitimate value given by the world health organization.展开更多
In this study,the multi-sensing system based on the tin oxide pH electrode for the ion-determination was presented. With the advantages of the real-time supervisory control apparatus,the measured values could be displ...In this study,the multi-sensing system based on the tin oxide pH electrode for the ion-determination was presented. With the advantages of the real-time supervisory control apparatus,the measured values could be displayed on the liquid crystal display (LCD) immediately.In this study,the basic sensor was the tin oxide pH electrode,which was fabricated by radio frequency (r.f.) sputtering system on the indium tin oxide (ITO)/glass substrate.Moreover,the major blocks of the system consist of the tin oxide electrode-based ion selective electrodes (ISEs),an analog front-ended readout circuit,a microcontroller with built-in analog to digital (A/D) converter.In addition,by the embedded system design,the measurement results can be transmitted to a portable system or computer through the Universal Serial Bus (USB) and Universal Asynchronous Receiver Transmitter (UART) interface immediately.According to the experimental results,the multi-sensing system has high performance and reliability for pH,K^+,and Na^+ detection.展开更多
Novel potassium ion selective electrodes (K^+ISEs) and cDNA array sensors based on porous silicon (PS) have been developed.The calibration curve for the K^+ISEs is linear within a wide range of pK=2.0~6.0 with the sl...Novel potassium ion selective electrodes (K^+ISEs) and cDNA array sensors based on porous silicon (PS) have been developed.The calibration curve for the K^+ISEs is linear within a wide range of pK=2.0~6.0 with the slope of 56 mV per decade,which is near Nernst response.The response time and detection limit are within 31 s and 0.5μmol/L,respectively.The selective coefficient for Na^+ is-3.8,satisfies the requirement for the assay of blood potassium.The response variation is within 2 mV during 2 months.The binding capacity,the dynamic range and the detection limit of the DNA sensors were improved by replacing glass slide with PS substrates.The cDNA array sensors can bear 80℃of high temperature,75% of humidity,3.6 kLx of irradiation and keep stable within 10 days when they are exposed in air.Good performances of the K^+ISE and the cDNA array sensor are attributed to the large internal surface area and the easily modified microstructure of PS.展开更多
文摘The percent ammonia nitrogen was determined in Passaic River waste water using Ion-Selective Electrode EPA Method 350.3. The intelligent ammonia sensor integrates ammonia electrode, pH electrode and Ammonia Ion electrode together to realize the in situ detection of ammonia. The test results have shown that the sensor is easy operation, low cost and no pollution. The ammonia is determined potentiometrically using an ammonia ion selective electrode and a pH/mV meter, having an expanded millivolt scale. The ammonia selective electrode uses a hydrophobic gas-permeable membrane to separate the sample solution from an electrode internal solution of ammonium chloride. Dissolved ammonia is converted to NH<sub>3</sub> gas by raising the pH to above 11.0 with a strong base. NH<sub>3</sub> gas diffuses the membrane and changes the internal solution pH that is sensed by the electrode. In single laboratory test results have been found 1.001 NH<sub>3</sub>-/L and 0.897 mg NH<sub>3</sub>-N/L, recoveries were 77.3% and 83.1%, respectively.
文摘Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health and help in normal mineralization of bone and formation of dental enamel. The determination of fluoride in some species was performed by using fluoride ion-selective electrode by direct measurement and standard addition method. The concentration of fluoride ion was determined in drinking water (from different place at Kathmandu), toothpaste, various brand of tea and coffees. The range of fluoride concentration in water sample was 0.16 to 0.39 mg/l, tea and coffee samples were 0.011 to 0.084 mg/l and its value of toothpaste was 0.026 to 0.75 mg/l. The concentration of fluoride ion obtain from different sample was compared with the legitimate value given by the world health organization.
文摘In this study,the multi-sensing system based on the tin oxide pH electrode for the ion-determination was presented. With the advantages of the real-time supervisory control apparatus,the measured values could be displayed on the liquid crystal display (LCD) immediately.In this study,the basic sensor was the tin oxide pH electrode,which was fabricated by radio frequency (r.f.) sputtering system on the indium tin oxide (ITO)/glass substrate.Moreover,the major blocks of the system consist of the tin oxide electrode-based ion selective electrodes (ISEs),an analog front-ended readout circuit,a microcontroller with built-in analog to digital (A/D) converter.In addition,by the embedded system design,the measurement results can be transmitted to a portable system or computer through the Universal Serial Bus (USB) and Universal Asynchronous Receiver Transmitter (UART) interface immediately.According to the experimental results,the multi-sensing system has high performance and reliability for pH,K^+,and Na^+ detection.
基金supported by National Natural Science Foundation of China(69925409,60276036)Shanghai Applied Material Foundation(0202).
文摘Novel potassium ion selective electrodes (K^+ISEs) and cDNA array sensors based on porous silicon (PS) have been developed.The calibration curve for the K^+ISEs is linear within a wide range of pK=2.0~6.0 with the slope of 56 mV per decade,which is near Nernst response.The response time and detection limit are within 31 s and 0.5μmol/L,respectively.The selective coefficient for Na^+ is-3.8,satisfies the requirement for the assay of blood potassium.The response variation is within 2 mV during 2 months.The binding capacity,the dynamic range and the detection limit of the DNA sensors were improved by replacing glass slide with PS substrates.The cDNA array sensors can bear 80℃of high temperature,75% of humidity,3.6 kLx of irradiation and keep stable within 10 days when they are exposed in air.Good performances of the K^+ISE and the cDNA array sensor are attributed to the large internal surface area and the easily modified microstructure of PS.