High-efficient isolated DC/DC converters with a high-efficiency synchronous reluctance generator(SRG)are the ultimate solutions in DC microgrid systems.The design and modeling of isolated DC/DC converters with the per...High-efficient isolated DC/DC converters with a high-efficiency synchronous reluctance generator(SRG)are the ultimate solutions in DC microgrid systems.The design and modeling of isolated DC/DC converters with the performance of SRG are carried out.On the generator side,reactive and active powers are used as pulse width modulation(PWM)control variables.Further,the flux estimator is used.Three-phase PWM rectifier is used by applying space vector modulation(SVM)with a constant switching frequency for direct power control.Further,the paper also includes the experimental validation of the results.The paper also proposes that highly efficient power converters and synchronous reluctance generators are required to achieve high performance for hybrid renewable energy systems applications.展开更多
EMI Filter Design and Performance for isolated full bridge buck converter is developed in this paper. In order to design a high performance EMI filter, many issues need to be considered beforehand. Some important issu...EMI Filter Design and Performance for isolated full bridge buck converter is developed in this paper. In order to design a high performance EMI filter, many issues need to be considered beforehand. Some important issues including accurate model of converter components, parasitic elements, its effect on EMI noise and impedance mismatch are included in this paper. A numerical prediction of EMI/EMC has the potential to evaluate EMI performances at the design stage and before prototyping. It can also help reduce the post-prototype EMC cost by minimizing late redesign and modifications of a design implementation. Saber simulator is used to analyze the EMI noises and EMI filter’s performance. Conducted EMI noise measurement and EMI filter design of isolated full bridge buck converter has been achieved while successfully satisfying the FCC class B limits in the frequency range from 150 kHz to 30 MHz. Simulation results are compared with experimental data and the effectiveness of the EMI simulation approach is demonstrated.展开更多
This paper introduces a design of high-precision high-voltage fiber-optic analog sig-nal isolation converter based on the technology of Voltage-to-Frequency (V/F) and Frequency-to-Voltage (F/V) conversion. It describe...This paper introduces a design of high-precision high-voltage fiber-optic analog sig-nal isolation converter based on the technology of Voltage-to-Frequency (V/F) and Frequency-to-Voltage (F/V) conversion. It describes the principle, system configuration and hardware design.展开更多
The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-...The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies.展开更多
In today’s fast-paced,information-driven world,data centers can offer high-speed,intricate capabilities on a larger scale owing to the ever-growing demand for networks and information systems.Because data centers pro...In today’s fast-paced,information-driven world,data centers can offer high-speed,intricate capabilities on a larger scale owing to the ever-growing demand for networks and information systems.Because data centers process and transmit information,stability and reliability are important.Data center power supply architectures rely heavily on isolated bidirectional DC-DC converters to ensure safety and stability.For the smooth operation of a data center,the power supply must be reliable and uninterrupted.In this study,we summarize the basic principle,topology,switch conversion strategy,and control technology of the existing isolated bidirectional DC-DC converters.Subsequently,existing research results and problems with isolated bidirectional DC-DC converters are reviewed.Finally,future trends in the development of isolated bidirectional DC-DC converters for data centers are presented,which offer valuable insights for solving engineering obstacles and future research directions in the field.展开更多
基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状...基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状态平均建模和PI控制器设计方法。首先,分析TAB的运行原理和Y型等效结构;然后,结合移相加占空比控制的特点和交流方波源等效方法,推导出TAB的广义状态空间平均模型;接着,在推得模型的基础上求得输入到输出的传递函数,设计出PI控制器参数。最后,结合数字仿真及样机实验验证了所提方法的正确性及有效性。展开更多
Due to the slow dynamic power-regulation characteristics of the electrolyser(EL),a novel integrated three-port DC/DC converter topology based on a phase-shifted full-bridge converter and dual active-bridge converter i...Due to the slow dynamic power-regulation characteristics of the electrolyser(EL),a novel integrated three-port DC/DC converter topology based on a phase-shifted full-bridge converter and dual active-bridge converter is proposed in this paper.Especially,the proposed converter can achieve a fast auxiliary response to the EL.This topology has the features of single-stage conversion,high system integration and compatibility with multiple operation modes.The operational principles and a hybrid modulation scheme of the proposed converter are analysed in detail.In addition,the power-transmission characteristics of each port and the soft-switching range are researched.On these bases,six operation modes suitable for a hydrogen energy-storage system are designed.The simulation and a 2-kW scaled-down experimental prototype are established to verify the feasibility and effectiveness of the proposed topology in different operation modes.展开更多
文摘High-efficient isolated DC/DC converters with a high-efficiency synchronous reluctance generator(SRG)are the ultimate solutions in DC microgrid systems.The design and modeling of isolated DC/DC converters with the performance of SRG are carried out.On the generator side,reactive and active powers are used as pulse width modulation(PWM)control variables.Further,the flux estimator is used.Three-phase PWM rectifier is used by applying space vector modulation(SVM)with a constant switching frequency for direct power control.Further,the paper also includes the experimental validation of the results.The paper also proposes that highly efficient power converters and synchronous reluctance generators are required to achieve high performance for hybrid renewable energy systems applications.
基金Sponsored by the National Science Foundation of China (Grant No.50477009).
文摘EMI Filter Design and Performance for isolated full bridge buck converter is developed in this paper. In order to design a high performance EMI filter, many issues need to be considered beforehand. Some important issues including accurate model of converter components, parasitic elements, its effect on EMI noise and impedance mismatch are included in this paper. A numerical prediction of EMI/EMC has the potential to evaluate EMI performances at the design stage and before prototyping. It can also help reduce the post-prototype EMC cost by minimizing late redesign and modifications of a design implementation. Saber simulator is used to analyze the EMI noises and EMI filter’s performance. Conducted EMI noise measurement and EMI filter design of isolated full bridge buck converter has been achieved while successfully satisfying the FCC class B limits in the frequency range from 150 kHz to 30 MHz. Simulation results are compared with experimental data and the effectiveness of the EMI simulation approach is demonstrated.
基金This work was supported by the National Meg-Science Engineering Project of the Chinese Government.
文摘This paper introduces a design of high-precision high-voltage fiber-optic analog sig-nal isolation converter based on the technology of Voltage-to-Frequency (V/F) and Frequency-to-Voltage (F/V) conversion. It describes the principle, system configuration and hardware design.
基金Project(50807002) supported by the National Natural Science Foundation of ChinaProject(SKLD10KM05) supported by Opening Fund of State Key Laboratory of Power System and Generation EquipmentsProject(201206025007) supported by the National Scholarship Fund,China
文摘The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies.
基金Supported by the Natural Science Foundation for Distinguished Young Scholars of Guangdong Province(2022B1515020002).
文摘In today’s fast-paced,information-driven world,data centers can offer high-speed,intricate capabilities on a larger scale owing to the ever-growing demand for networks and information systems.Because data centers process and transmit information,stability and reliability are important.Data center power supply architectures rely heavily on isolated bidirectional DC-DC converters to ensure safety and stability.For the smooth operation of a data center,the power supply must be reliable and uninterrupted.In this study,we summarize the basic principle,topology,switch conversion strategy,and control technology of the existing isolated bidirectional DC-DC converters.Subsequently,existing research results and problems with isolated bidirectional DC-DC converters are reviewed.Finally,future trends in the development of isolated bidirectional DC-DC converters for data centers are presented,which offer valuable insights for solving engineering obstacles and future research directions in the field.
文摘基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状态平均建模和PI控制器设计方法。首先,分析TAB的运行原理和Y型等效结构;然后,结合移相加占空比控制的特点和交流方波源等效方法,推导出TAB的广义状态空间平均模型;接着,在推得模型的基础上求得输入到输出的传递函数,设计出PI控制器参数。最后,结合数字仿真及样机实验验证了所提方法的正确性及有效性。
基金supported by the National Key R&D Program of China (no.2018YFB1503100)the National Natural Science Foundation of China (no.51907021).
文摘Due to the slow dynamic power-regulation characteristics of the electrolyser(EL),a novel integrated three-port DC/DC converter topology based on a phase-shifted full-bridge converter and dual active-bridge converter is proposed in this paper.Especially,the proposed converter can achieve a fast auxiliary response to the EL.This topology has the features of single-stage conversion,high system integration and compatibility with multiple operation modes.The operational principles and a hybrid modulation scheme of the proposed converter are analysed in detail.In addition,the power-transmission characteristics of each port and the soft-switching range are researched.On these bases,six operation modes suitable for a hydrogen energy-storage system are designed.The simulation and a 2-kW scaled-down experimental prototype are established to verify the feasibility and effectiveness of the proposed topology in different operation modes.