In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene...In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.展开更多
China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and e...China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and electronics for the VLAST is currently underway.The nuclide detector is a core detector in the VLAST.It mainly measures nuclides’charges and distinguishes high-energy gamma rays and electrons.This paper will discuss the prototype readout electronics for the VLAST’s nuclide detector,which accurately measures the charge signal of the photomultiplier tubes using the VATA160 applicationspecific integrated circuit chip;furthermore,we consider a series of critical problems,including radiation-hardening and environment monitoring.The test results show that the system exhibits stable operation,good performance,and good technical indicators.Furthermore,each electronic channel achieves a dynamic range of 0-12.5 pC,the random noise level exceeds 1.6 fC,and the integral nonlinearity exceeds 0.35%.展开更多
基金Foundation of China (Nos. 12227805, U1831206, 12103095, 12235012, 12273120, and 11973097)the Scientific Instrument Developing Project of the Chinese Academy of Sciences (No. GJJSTD20210009)。
文摘In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.
基金supported by the National Natural Science Foundation of China(Nos.U2031206,U1831206,11975292,11875304)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.GJJSTD20210009)+1 种基金the CAS“Light of West China”Programthe CAS Pioneer Hundred Talent Program。
文摘China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and electronics for the VLAST is currently underway.The nuclide detector is a core detector in the VLAST.It mainly measures nuclides’charges and distinguishes high-energy gamma rays and electrons.This paper will discuss the prototype readout electronics for the VLAST’s nuclide detector,which accurately measures the charge signal of the photomultiplier tubes using the VATA160 applicationspecific integrated circuit chip;furthermore,we consider a series of critical problems,including radiation-hardening and environment monitoring.The test results show that the system exhibits stable operation,good performance,and good technical indicators.Furthermore,each electronic channel achieves a dynamic range of 0-12.5 pC,the random noise level exceeds 1.6 fC,and the integral nonlinearity exceeds 0.35%.