Portable Distortion Degree of Measuring Apparatus
1
作者 王鑫 吕常智 王德勇 《Journal of Measurement Science and Instrumentation》 CAS 2011年第1期78-80,共3页
Distortion is a technical indicator in the field of voice signal processing. The design is a portable distortion degree tester, based on Field-Progranmmble Gate Array (FleA, EP2C20) as the cote, using harmonic analy... Distortion is a technical indicator in the field of voice signal processing. The design is a portable distortion degree tester, based on Field-Progranmmble Gate Array (FleA, EP2C20) as the cote, using harmonic analysis method which better solve the distortion problem of acctwacy. It can achieve the signal transformation from the time-domain to the frequency-donkain, and is widely used for signal spectrum analysis. All the componets used in the design are low power, high perf-, low drift and industrial grade compionents. The reference voltage sources of ADC and DAC have identical performance of high stability, high precision. The dtr.k is the precise stable clock with FPGA temperature compensation. This project can get the cost-effective, high-precision, low power and portable design goals. 展开更多
关键词 distortion degree FPGA measuring apparatus
下载PDF
Techniques and Apparatus for Measuring Rotational Core Losses of Soft Magnetic Materials
2
作者 Jin-Jiang Zhong You-Guang Guo +2 位作者 Jian-Guo Zhu Hai-Yan Lu Jian-Xun Jin 《Journal of Electronic Science and Technology of China》 2007年第3期218-225,共8页
In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux densi... In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux density vector is rotating. Therefore, the magnetic properties of the core materials under the rotating flux density vector excitation should be properly measured, modeled and applied in the design and analysis of these electromagnetic devices. This paper presents an extensive review on the development of techniques and apparatus for measuring the rotational core losses of soft magnetic materials based on the experiences of various researchers in the last hundred years. 展开更多
关键词 Magnetic property measurement measuring apparatus measuring technique rotational core loss soft magnetic material.
下载PDF
Blasting cumulative damage effects of underground engineering rock mass based on sonic wave measurement 被引量:5
3
作者 闫长斌 《Journal of Central South University of Technology》 EI 2007年第2期230-235,共6页
The principle of sonic wave measurement was introduced, and cumulative damage effects of underground engineering rock mass under blasting load were studied by in situ test, using RSM-SY5 intelligent sonic wave apparat... The principle of sonic wave measurement was introduced, and cumulative damage effects of underground engineering rock mass under blasting load were studied by in situ test, using RSM-SY5 intelligent sonic wave apparatus. The blasting test was carried out for ten times at some tunnels of Changba Lead-Zinc Mine. The damage depth of surrounding rock caused by old blasting excavation (0.8-1.2 m) was confirmed. The relation between the cumulative damage degree and blast times was obtained. The results show that the sonic velocity decreases gradually with increasing blast times, hut the damage degree (D) increases. The damage cumulative law is non-linear. The damage degree caused by blast decreases with increasing distance, and damage effects become indistinct. The blasting damage of rock mass is anisotropic. The damage degree of rock mass within charging range is maximal. And the more the charge is, the more severe the damage degree of rock mass is. The test results provide references for researches of mechanical parameters of rock mass and dynamic stability analysis of underground chambers. 展开更多
关键词 sonic wave measurement cumulative damage effects damage degree blasting load surrounding rock of underground engineering RSM-SY5 intelligent sonic wave apparatus
下载PDF
VFT PHASE VOLTAGE MEASUREMENT IN THREE-PHASE ENCLOSED GIS 被引量:1
4
作者 Zou Jianhua(邹建华) +3 位作者 Yue Ziding(岳子丁) Li Yang(李洋) 《Academic Journal of Xi'an Jiaotong University》 2002年第2期101-108,共8页
The measuring of VFT phase voltage in three-phase enclosed GIS is more complex and difficult than in single-phase ones. There are 3 capacitive sensors in the measuring system, the outputs of which are with a linear re... The measuring of VFT phase voltage in three-phase enclosed GIS is more complex and difficult than in single-phase ones. There are 3 capacitive sensors in the measuring system, the outputs of which are with a linear relation to the three phase voltages. This linear relation is presented with a factorial matrix. Because each capacitive sensor is coupled with the electric field of three phases (A, B, and C), the electric coupling coefficients are introduced. In order to determine the matrix of electric coupling coefficients, the numerical calculation method can be used. From the discussion on two types of three-phase enclosed GIS bus, i.e. standard arrangement and biased arrangement, the dominant electric coupling coefficients are named, which can be simply and approximately calculated by an analytic expression. Finally, as an example, the waveforms of VFT phase voltage generated on a three-phase enclosed GIS bus model are displayed. When a capacitive sensor is located at the ’shortest point’ of phase A (or B, or C), the VFT phase voltage V A (or V B, or V C) can almost be measured by that capacitive sensor alone. 展开更多
关键词 gas insulated substation(GIS) very fast transients(VFT) VOLTAGE measurEMENT electric field ANALYTIC expression measurEMENT apparatus VFT phase VOLTAGE wave
下载PDF
High Accuracy Zoom Magnification Measurement
5
作者 曾政东 孙长库 +2 位作者 郑义忠 YAN Mingdong CHANG Sengkeong 《Transactions of Tianjin University》 EI CAS 2010年第4期289-294,共6页
A precise zoom magnification is important for semiconductor industry and biomedical research. A novel measurement method is demonstrated for optical zoom magnification measurement in this paper. The magnification is o... A precise zoom magnification is important for semiconductor industry and biomedical research. A novel measurement method is demonstrated for optical zoom magnification measurement in this paper. The magnification is obtained by pattern correction between barcode image formed by optical zoom and reference image generated by an ideal optical model. Measurement accuracy which is better than 0.06% has been achieved for optical zoom magnification. Compared with traditional concept, the measurement results are only dependent on two line edges. The barcode correlation method can achieve higher accuracy and better robustness by using the information over the whole field of view. 展开更多
关键词 MAGNIFICATION MICROSCOPE optical zoom BARCODE image processing measurement apparatus
下载PDF
Function of large-volume high-pressure apparatus at SECUF
6
作者 Pinwen Zhu Qiang Tao +2 位作者 Lu Wang Zhi He Tian Cui 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期81-85,共5页
Pressure allows the precise tuning of a fundamental parameter, the interatomic distance, which controls the electronic structure and virtually all interatomic interactions that determine material properties. Hence, pr... Pressure allows the precise tuning of a fundamental parameter, the interatomic distance, which controls the electronic structure and virtually all interatomic interactions that determine material properties. Hence, pressure tuning is an effective tool in the search for new materials with enhanced properties. To realize pressure tuning on matter, large-volume press (LVP) apparatuses have been widely used not only to synthesize novel materials but also to implement the in situ measurement of physical properties. Herein, we introduce the LVP apparatuses, including belt-type, cubic anvil, and 6-8 type multi-anvil, that will be constructed at the Synergetic Extreme Condition User Facility (SECUF) at Jilin University. Typically, cell volumes of 1000 mm3 can be obtained at 20 GPa in a belt-type apparatus that is significantly larger than that obtained in a 6-8 type multi-anvil apparatus at the same pressure. Furthermore, the in situ measurement of physical prop- erties, including thermological, electrical, and mechanical behaviors, is coupled to these LVP apparatuses. Some typical results of both synthetic experiments and in situ measurements obtained from the LVP apparatuses are also reviewed. 展开更多
关键词 high pressure large-volume press multi-anvil apparatus in situ measurement synthesis
原文传递
Study of amplification coefficient in a water-cooling Gardon-type heat power measuring apparatus 被引量:1
7
作者 Li Miao Li Yunze +3 位作者 Zhang Hongsheng Wang Shengnan Li Yunhua Liu Jia 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2015年第2期410-417,共8页
A new water-cooling Gardon-type heat power measuring apparatus is designed to meet the need of heat power source management and distribution. The steady state measurement mathe- matic model of the apparatus is built u... A new water-cooling Gardon-type heat power measuring apparatus is designed to meet the need of heat power source management and distribution. The steady state measurement mathe- matic model of the apparatus is built up in theory and the system amplification coefficient is defined as the ratio of the heat power to the temperature difference of the device, with which the value of the measured source power can be calculated easily with the corresponding temperature difference. In order to obtain an optimal heat power measuring system, the coefficients that can influence the relationship between the amplification coefficient, the temperature difference, and the heat power are analyzed. On the basis of these analyses, a set of experimental device is constructed and a num- ber of experiments are carried on. Compared with the input heat power sample data, the error of the experimental measuring results is less than 4-2%, and the experimental measuring values are in good agreement with the calculated theoretical ones. The heat power measuring apparatus can be applied in heat flux or heat power measurement in other fields due to its simple structure and high accuracy. 展开更多
关键词 Amplification coefficient Gardon-type Heat flux Heat power measuring apparatus Water-cooling
原文传递
金属阻尼性能测试方法的现状与发展 被引量:14
8
作者 郑成琪 程晓农 《实验力学》 CSCD 北大核心 2004年第2期248-256,共9页
阻尼金属正成为减振降噪的首选方案之一,而阻尼性能测试结果可比性差已经成为制约高阻尼金属材料发展的一个"瓶颈"问题。由于自由衰减速率,共振峰宽度和应力-应变相位差都能够反映金属材料的阻尼性能高低,阻尼测试方法较多。... 阻尼金属正成为减振降噪的首选方案之一,而阻尼性能测试结果可比性差已经成为制约高阻尼金属材料发展的一个"瓶颈"问题。由于自由衰减速率,共振峰宽度和应力-应变相位差都能够反映金属材料的阻尼性能高低,阻尼测试方法较多。本文论述了表征金属材料阻尼性能的物理量,并分析了由于设备,测试方法和试验参数不同可能引入的系统误差。介绍了弯曲共振装置,扭摆仪和DMTA动态热机械分析仪等三种主要测试设备的原理和特点。文中还对测试设备和方法存在的系统误差,阻尼性能参数之间的换算以及金属材料阻尼性能的综合评价等若干问题进行了探讨,并对进一步完善和规范金属阻尼性能测试方法提出了建议。 展开更多
关键词 金属材料 阻尼参数 减振降噪 衰减速率 复数模量 品质因子
下载PDF
An apparatus for accurately measuring solubilities of gases in liquids at elevated temperatures and pressures
9
作者 HAN Bu-Xing YAN Hai-Ke HU Ri-Heng 《Acta Chimica Sinica English Edition》 SCIE CAS CSCD 1989年第6期481-486,共1页
An apparatus for measuring solubilities of gases in liquids at elevated temperatures and pressures has been constructed. Using this apparatus, the slubilities of N_2 and CO_2 in some solvents have been determined in t... An apparatus for measuring solubilities of gases in liquids at elevated temperatures and pressures has been constructed. Using this apparatus, the slubilities of N_2 and CO_2 in some solvents have been determined in the temperature range between 20 and 230℃, and at pressures up to 130 atm. The experimental results obtained generally agree well with literature values. It is shown that this apparatus is reliable; attainment of equilibria needs only about 5 hours; precision of the measure- ments is ±0.2%. 展开更多
关键词 An apparatus for accurately measuring solubilities of gases in liquids at elevated temperatures and pressures
全文增补中
Heat of Boron Trifluoride–Methanol System Determined by Bunsen Ice Calorimeter
10
作者 Weijiang Zhang Yace Zhang +1 位作者 Yuvaraja Gutha Jiao Xu 《Transactions of Tianjin University》 EI CAS 2018年第4期370-374,共5页
The complex heat of BF_3 with methanol was measured by utilizing the principle of the Bunsen ice calorimeter. The complex heat of BF_3 –methanol was found to be 49.2 and 58.1 kJ/mol when the molar ratio of BF_3 to me... The complex heat of BF_3 with methanol was measured by utilizing the principle of the Bunsen ice calorimeter. The complex heat of BF_3 –methanol was found to be 49.2 and 58.1 kJ/mol when the molar ratio of BF_3 to methanol was 1:2 and 1:1,respectively. In addition,the complex heat of BF_3 –anisole was also measured to test the apparatus error. The BF_3 –anisole result showed a calorimeter value of 53.1 kJ/mol with a system error of 2.3% as compared with the value reported in the literature. The mechanism of the reaction of BF_3 and methanol was interpreted based on our obtained results. This apparatus is useful and suitable for measuring the heat of other liquid–gas and liquid–liquid reactions. 展开更多
关键词 HEAT of reaction BF 3–methanol BF 3–anisole Bunsen ICE CALORIMETER Gas–liquid system measurement apparatus
下载PDF
The Use of Tamping Machine for Diagnosising the Longitudinal Forces in Rails of CWR Track
11
作者 Wladyslaw Koc Andrzej Wilk +1 位作者 Slawomir Grulkowski Piotr Chrostowski 《Journal of Civil Engineering and Architecture》 2010年第11期11-25,共15页
In the novel approach to the diagnostic tests of continuous welded rail (CWR) track by the use of the tamping machine, the fundamental statement related to the recording of the curvature with a definite value of the... In the novel approach to the diagnostic tests of continuous welded rail (CWR) track by the use of the tamping machine, the fundamental statement related to the recording of the curvature with a definite value of the lateral displacement being subjected to verification, can provide a basis for the determination of the longitudinal axial force in the rail. An attempt has also been made to define an alternative factor which by means of the measured signals, could be used for the determination of the axial forces in the rail sections. A power engineering approach has been adopted to this concept. Within the framework of the experimental investigations, measurements were carried out in the track test section. The investigations were based on stretching the rail sections by stretchers and on lateral displacements of the track by the tamping machine. The operation of the measuring apparatus was also tested in the experimental railway track section while carrying out the geometrical adjustments by the tamping machine. As a result of next series of the investigation carried out in 2006-2007, the authors worked out a procedure of estimating the longitudinal forces in rails of CWR track. 展开更多
关键词 CWR track longitudinal forces lateral displacements tamping machine measuring apparatus.
下载PDF
Development of All-Weather and Real-Time Bottom-Mounted Monitor of Bed Load Quantity
12
作者 窦希萍 左其华 +1 位作者 应强 黄海龙 《China Ocean Engineering》 SCIE EI CSCD 2014年第6期807-814,共8页
Quantity of bed load is an important physical parameter in sediment transport research. Aiming at the difficulties in the bed load measurement, this paper develops a bottom-mounted monitor to measure the bed load tran... Quantity of bed load is an important physical parameter in sediment transport research. Aiming at the difficulties in the bed load measurement, this paper develops a bottom-mounted monitor to measure the bed load transport rate by adopting the sedimentation pit method and resolving such key problems as weighing and desilting, which can achieve long-time, all-weather and real-time telemeasurement of the bed load transport rate of plain rivers, estuaries and coasts. Both laboratory and field tests show that this monitor is reasonable in design, stable in properties and convenient in measurement, and it can be used to monitor the bed load transport rate in practical projects. 展开更多
关键词 quantity of bed load bed load rate sediment transport real-time monitoring measuring apparatus
下载PDF
化工仪表的保运质量体系下的维护应用
13
作者 刘博唯 《今日自动化》 2022年第2期155-157,共3页
随着我国经济的快速发展,作为第二产业的石油、化工、冶金等产业也在飞速发展中,对节能降耗、提高质量、治污减排和安全生产的日益追求上提出了更高的标准,其中对于污染严重、出现事故影响严重的化工行业来讲也存有新的机遇和挑战。化... 随着我国经济的快速发展,作为第二产业的石油、化工、冶金等产业也在飞速发展中,对节能降耗、提高质量、治污减排和安全生产的日益追求上提出了更高的标准,其中对于污染严重、出现事故影响严重的化工行业来讲也存有新的机遇和挑战。化工行业的保运体系下有动静电仪四大专业,是炼化企业能够正常运转的有力保障。 展开更多
关键词 化工行业 仪器仪表 工艺参数 测量介质 仪表性能
下载PDF
Electronic moxibustion apparatus and traditional moxibustion in treating knee osteoarthritis:a randomized controlled trial 被引量:3
14
作者 Xue Kun Xing Qiu-juan +3 位作者 Wang Ya-qiong Wu Ji Zhao Hai-yin Lu Wang 《Journal of Acupuncture and Tuina Science》 CSCD 2020年第4期286-294,共9页
Objective:To observe the clinical efficacy of DZWJY-1 type electronic moxibustion apparatus and traditional moxibustion in treating knee osteoarthritis(KOA).Methods:A total of 76 eligible patients were randomized into... Objective:To observe the clinical efficacy of DZWJY-1 type electronic moxibustion apparatus and traditional moxibustion in treating knee osteoarthritis(KOA).Methods:A total of 76 eligible patients were randomized into an electronic moxibustion apparatus group and a traditional moxibustion group,with 38 cases in each group.The electronic moxibustion apparatus group was intervened by DZWJY-1 type electronic moxibustion apparatus,and the traditional moxibustion group received moxa stick moxibustion for treatment.Neixiyan(EX-LE 4),Dubi(ST 35),Xuehai(SP 10)and Liangqiu(ST 34)were selected for both groups and the treatment was conducted 3 times a week for a total of 12 times.The visual analog scale(VAS)and the Western Ontario and McMaster Universities osteoarthritis index(WOMAC)scores were observed before treatment and after 6 and 12 sessions of treatment,respectively.Results:There were 4 dropout cases in the traditional moxibustion group.Therefore,this trial had 72 valid cases,including 38 cases in the electronic moxibustion apparatus group and 34 cases in the traditional moxibustion group,the differences in the baseline data between the two groups were statistically insignificant(P>0.05).After 6 and 12 sessions of treatment,the VAS scores decreased significantly with the increase of treatment sessions in both groups(all P<0.01),and the betweengroup differences were statistically insignificant at the same time points(both P>0.05).The pain intensity was evaluated using the weighted value of VAS score.The markedly effective rate was 47.4%and the total effective rate was 89.5%in the electronic moxibustion apparatus group,versus 50.0%and 94.1%in the traditional moxibustion group,and the betweengroup differences were statistically insignificant(both P>0.05).After 6 and 12 sessions of treatment,the total score and the component scores including pain,stiffness and difficulty moving in the WOMAC decreased significantly with the increase of treatment sessions in both groups(all P<0.01),and the between-group differences were statistically insignificant(all P>0.05).Conclusion:Electronic moxibustion apparatus and traditional moxibustion both are effective in reducing joint pain and improving joint function in KOA patients,and they are equivalent comparing the clinical efficacy. 展开更多
关键词 Moxibustion Therapy Moxa Stick Moxibustion Electronic Moxibustion apparatus Osteoarthritis Knee Pain measurement Visual Analog Scale
原文传递
新建地方院校实验室测量仪器管理与维护——以河套学院为例 被引量:1
15
作者 杨学军 王霞 秦美荣 《河套学院论坛》 2017年第1期72-74,共3页
实验室测量仪器管理维护的好坏,直接影响测量课程实践教学的效果,根据河套学院测量实验管理的实际情况,结合多年从事测量仪器的管理和维修维护工作经验,介绍了测量仪器管理和维护的方法,以求对提高河套学院测量实践教学质量以及测量仪... 实验室测量仪器管理维护的好坏,直接影响测量课程实践教学的效果,根据河套学院测量实验管理的实际情况,结合多年从事测量仪器的管理和维修维护工作经验,介绍了测量仪器管理和维护的方法,以求对提高河套学院测量实践教学质量以及测量仪器的使用效益有所帮助。 展开更多
关键词 实验室 测量仪器 管理 维护
原文传递
Experimental study of oil-water interface layers dilatation rheological properties
16
作者 ZHU Hong ZHAO Feng +3 位作者 TANG Ji’an LI Jingru LI Xingchang JIANG Long 《Chinese Science Bulletin》 SCIE EI CAS 2002年第24期2056-2059,共4页
Oil-water interface layers dilatation rheological properties have been measured with the liquid-liquid interface film pressure measurement apparatus, which was based on the principles of Langmuir film balance. Experim... Oil-water interface layers dilatation rheological properties have been measured with the liquid-liquid interface film pressure measurement apparatus, which was based on the principles of Langmuir film balance. Experimental results show that it is possible to form the interface-associated material caused by the attraction of the dispersion forces at the pure alkane-water interface. The type of material is sensitive to the interfacial pressure. Under the influence of the interfacial pressure, the stability of the interface associated materials decreases with the increase of the number of alkane carbons. 展开更多
关键词 LIQUID-LIQUID INTERFACE film pressure measurement apparatus INTERFACE dilatational ELASTICITY dispersion FORCES INTERFACE associated material.
下载PDF
A Personal Wireless System for Cardiovascular Monitoring
17
作者 YANG Pan PAN Qing +6 位作者 LIN Chang-yu ZHOU Jia FU Xiao LI Li GONG Shi-jin YAN Jing NING Gang-min 《Chinese Journal of Biomedical Engineering(English Edition)》 2018年第1期28-32,共5页
Chronic diseases, especially cardiovascular diseases, have become one of the leading health problems in China. For preventing cardiovascular diseases and improving treatment, it is necessary to regularly monitor vascu... Chronic diseases, especially cardiovascular diseases, have become one of the leading health problems in China. For preventing cardiovascular diseases and improving treatment, it is necessary to regularly monitor vascular status related physiological signals at home. We designed a home-used wireless system for daily monitoring cardiovascular condition. Vital physiological signs are obtained by a chair-based measurement apparatus and then transmitted by bluetooth. Finally, these data are delivered to a remote healthcare server through internet. General practitioners can analyze the related indices and make an electronic report to users, who can check health status and understand cardiovascular risks. 展开更多
关键词 CARDIOVASCULAR MONITORING chair-based measurement apparatus HEALTH MANAGEMENT
下载PDF