Currently,cigarette smoke(CS)remains a major contributor to disease morbidity and mortality.CS can be divided into cigarette mainstream smoke(CMS)and side-stream smoke,depending on where it is produced by burning toba...Currently,cigarette smoke(CS)remains a major contributor to disease morbidity and mortality.CS can be divided into cigarette mainstream smoke(CMS)and side-stream smoke,depending on where it is produced by burning tobacco^([1]).CMS is inhaled by smokers from the filter end during cigarette combustion and is strongly associated with the development of several diseases^([2-4]).展开更多
The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the t...The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels.展开更多
The centralized smoke exhaust system of shield tunnel is an important determinant for tunnel fire safety,and the use of different design parameters of the tunnel smoke exhaust system will affect the smoke exhaust effe...The centralized smoke exhaust system of shield tunnel is an important determinant for tunnel fire safety,and the use of different design parameters of the tunnel smoke exhaust system will affect the smoke exhaust effect in the tunnel,and the influence of different design parameters on the smoke exhaust effect and temperature attenuation of the tunnel can help engineers in designing a more effective centralized smoke exhaust system for the tunnel.In this paper,the Fire Dynamic Simulator(FDS)is utilized to examine smoke exhaust vent settings for a centralized exhaust system in shield tunnel with both flat and sloped conditions,including slopes of+4.5%and−4.5%,under a 30MWfire power with a 150m^(3)/s smoke exhaust rate.The results suggest that maintaining a vent spacing of 60m and a vent size of 4.0 m×1.5 m is a reasonable configuration for centralized smoke exhaust systems in both flat and slope shield tunnels.This choice helpsminimize construction costs and prevent excessive smoke accumulation.It also promotes favorable conditions for maintaining temperature distribution at 2-m height,visibility,smoke spread distance,and temperature below the ceiling,all below the threshold values,while ensuring high smoke extraction efficiency.However,in the slope section,the chimney effect can disrupt exhaust efficiency,visibility,ceiling temperature,and temperature distribution at a height of 2 m.Employing different opening methods,such as having 2 vents up and 4 vents down in a+4.5%slope and 4 vents up and 2 vents down in a−4.5%slope,can help mitigate these effects.Furthermore,the temperature decay formula for shield tunnels follows a bi-exponential decay pattern,and different design parameters of centralized smoke exhaust systems have minimal effects on temperature decay in shield tunnels.展开更多
In the rapidly evolving urban landscape,outdoor parking lots have become an indispensable part of the city’s transportation system.The growth of parking lots has raised the likelihood of spontaneous vehicle combus-ti...In the rapidly evolving urban landscape,outdoor parking lots have become an indispensable part of the city’s transportation system.The growth of parking lots has raised the likelihood of spontaneous vehicle combus-tion,a significant safety hazard,making smoke detection an essential preventative step.However,the complex environment of outdoor parking lots presents additional challenges for smoke detection,which necessitates the development of more advanced and reliable smoke detection technologies.This paper addresses this concern and presents a novel smoke detection technique designed for the demanding environment of outdoor parking lots.First,we develop a novel dataset to fill the gap,as there is a lack of publicly available data.This dataset encompasses a wide range of smoke and fire scenarios,enhanced with data augmentation to ensure robustness against diverse outdoor conditions.Second,we utilize an optimized YOLOv5s model,integrated with the Squeeze-and-Excitation Network(SENet)attention mechanism,to significantly improve detection accuracy while maintaining real-time processing capabilities.Third,this paper implements an outdoor smoke detection system that is capable of accurately localizing and alerting in real time,enhancing the effectiveness and reliability of emergency response.Experiments show that the system has a high accuracy in terms of detecting smoke incidents in outdoor scenarios.展开更多
This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under ...This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under different conditions,including variations in heat release rates,exhaust volumetric flow rates,spacing between smoke outlets,and the longitudinal fire source positions.Results indicate that altering the fire source positions and the smoke outlets in the tunnel leads to variations in the properties of smoke flow both the fire source upstream and downstream;the distance between fire source and smoke outlet increases gradually,airflow rate decreases initially and eventually reaches a stable state.Similarly,smoke mass flow rate exhibits an increasing trend that eventually reaches a stable state.Moreover,the heat exchange between the tunnel walls and hot smoke increases as the smoke outlet moves further away from the fire source.This interaction leads to a reduction in the heat exhaust coefficient and a decrease in the distance the smoke spreads.This study investigates the impact of altering the relative longitudinal fire source positions and smoke outlet on smoke flow characteristics by numerical simulation.A theoretical analytical method is used to give a predictive model for the heat exhaust coefficient and the smoke spreading distance.This research can support the theory and technical process of tunnel smoke exhaust prevention and control.展开更多
Industrial activities, through the human-induced release of Green House Gas (GHG) emissions, have beenidentified as the primary cause of global warming. Accurate and quantitative monitoring of these emissions isessent...Industrial activities, through the human-induced release of Green House Gas (GHG) emissions, have beenidentified as the primary cause of global warming. Accurate and quantitative monitoring of these emissions isessential for a comprehensive understanding of their impact on the Earth’s climate and for effectively enforcingemission regulations at a large scale. This work examines the feasibility of detecting and quantifying industrialsmoke plumes using freely accessible geo-satellite imagery. The existing systemhas so many lagging factors such aslimitations in accuracy, robustness, and efficiency and these factors hinder the effectiveness in supporting timelyresponse to industrial fires. In this work, the utilization of grayscale images is done instead of traditional colorimages for smoke plume detection. The dataset was trained through a ResNet-50 model for classification and aU-Net model for segmentation. The dataset consists of images gathered by European Space Agency’s Sentinel-2 satellite constellation from a selection of industrial sites. The acquired images predominantly capture scenesof industrial locations, some of which exhibit active smoke plume emissions. The performance of the abovementionedtechniques and models is represented by their accuracy and IOU (Intersection-over-Union) metric.The images are first trained on the basic RGB images where their respective classification using the ResNet-50model results in an accuracy of 94.4% and segmentation using the U-Net Model with an IOU metric of 0.5 andaccuracy of 94% which leads to the detection of exact patches where the smoke plume has occurred. This work hastrained the classification model on grayscale images achieving a good increase in accuracy of 96.4%.展开更多
Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal...Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal of the tunnel follows aW-shaped distribution.The congestion situation does not allowfor immediate longitudinal smoke exhaust at the early stage of the fire,and the natural spread of smoke is complicated.An exhaustive investigation was carried out to analyze the smoke behaviors during a fire incident,employing the fire dynamics software FDS,considering five slopes and four fire locations.The simulation results reveal that the layer of high-temperature smoke becomes thicker as one gets closer to the fire source.The thermal pressure difference significantly impacts the temperature distribution within the tunnel and the distance of smoke spread.The value of the thermal pressure difference is significantly affected by changes in slope.It reaches a maximum of 157 Pa at a 5%slope,while it is only 41 Pa at a 1%slope when the fire occurs at the V-point.Fire hazards vary across locations within the W-shaped tunnel,necessitating separate consideration of the V-point and inverted V-point fire characteristics.The mass flow rate in small and large slope tunnels shows different decay rates due to variations in the main forces acting on the movement.Hence,two equations have been developed to predict the smoke mass flow rate,indicating a nonlinear relationship with the tunnel slope and the distance fromthe fire source.The tunnel slope inversely affects the smoke mass flowrate at the same location.The results can be utilized as a reference for conducting evacuation operations and aiding rescues during aW-shaped tunnel fire.展开更多
Chronic obstructive pulmonary disease(COPD)is a multifaceted syndrome characterized by a dysregulated inflammatory cascade within the respiratory system,primarily triggered by exposure to harmful particles and gases,n...Chronic obstructive pulmonary disease(COPD)is a multifaceted syndrome characterized by a dysregulated inflammatory cascade within the respiratory system,primarily triggered by exposure to harmful particles and gases,notably from cigarette smoke.This inflammatory response is orchestrated by innate immune cells like macrophages and epithelial cells,which recognize danger signals released from damaged cells.Prolonged inflammation prompts an adaptive immune reaction mediated by dendritic cells,culminating in the formation of lymphoid follicles and involving a complex interplay of T and B cells,as well as cytotoxic activity.Additionally,both viral and bacterial infections exacerbate COPD by further igniting inflammatory pathways,perpetuating the chronic inflammatory state.This comprehensive review encapsulates the intricate interplay between innate and adaptive immunity in COPD,with a particular focus on the role of cigarette smoke in its pathogenesis and potential therapeutic targets.展开更多
The United Kingdom may soon become a world leader in forging a smoke-free generation.Last month,the country passed a bill that bans the sale of cigarettes to anyone born in 2009 or later.The prime minister claims the ...The United Kingdom may soon become a world leader in forging a smoke-free generation.Last month,the country passed a bill that bans the sale of cigarettes to anyone born in 2009 or later.The prime minister claims the policy will"phase out smoking in young people almost completely as early as 2040."A final vote by Parliament is expected next month.Tobacco claims 8 million lives every year,and could claim a billion lives over this century-mostly in low-and middle-income countries.For every person that dies,at least 30 more suffer from smokingrelated chronic disease.The benefits of a tobacco-free society would be transformational.展开更多
Objective This study assesses the impact of smoke-free legislation on the incidence rate for acute myocardial infarction(AMI)and stroke in Shenzhen.Methods Data on ischemic(n=72,945)and hemorrhagic(n=18,659)stroke and...Objective This study assesses the impact of smoke-free legislation on the incidence rate for acute myocardial infarction(AMI)and stroke in Shenzhen.Methods Data on ischemic(n=72,945)and hemorrhagic(n=18,659)stroke and AMI(n=17,431)incidence covering about 12 million people in Shenzhen from 2012 to 2016 were used.Immediate and gradual changes in incidence rates were analyzed using segmented Poisson regression.Results Following the smoke-free legislation,a 9%(95%CI:3%-15%)immediate reduction was observed in AMI incidence,especially in men(8%,95%CI:1%-14%)and in those aged 65 years and older(17%,95%CI:9%-25%).The gradual annual benefits were observed only in hemorrhagic and ischemic stroke incidence,with a 7%(95%CI:2%-11%)and 6%(95%CI:4%-8%)decrease per year,respectively.This health effect extended gradually to the 50-64 age group.In addition,neither the immediate nor gradual decrease in stroke and AMI incidence rates did not show statistical significance among the 35-49 age group(P>0.05).Conclusion Smoke-free legislation was enforced well in Shenzhen,which would generate good experiences for other cities to enact and enforce smoke-free laws.This study also provided more evidence of the health benefits of smoke-free laws on stroke and AMI.展开更多
Objective To analyze the association between exposure to second-hand smoke(SHS) and 23 diseases,categorized into four classifications, among the Chinese population.Methods We searched the literature up to June 30, 202...Objective To analyze the association between exposure to second-hand smoke(SHS) and 23 diseases,categorized into four classifications, among the Chinese population.Methods We searched the literature up to June 30, 2021, and eligible studies were identified according to the PECOS format: Participants and Competitors(Chinese population), Exposure(SHS),Outcomes(Disease or Death), and Study design(Case-control or Cohort).Results In total, 53 studies were selected. The odds ratio(OR) for all types of cancer was 1.79(1.56–2.05), and for individual cancers was 1.92(1.42–2.59) for lung cancer, 1.57(1.40–1.76) for breast cancer, 1.52(1.12–2.05) for bladder cancer, and 1.37(1.08–1.73) for liver cancer. The OR for circulatory system diseases was 1.92(1.29–2.85), with a value of 2.29(1.26–4.159) for stroke. The OR of respiratory system diseases was 1.76(1.13–2.74), with a value of 1.82(1.07–3.11) for childhood asthma. The original ORs were also shown for other diseases. Subgroup analyses were performed for lung and breast cancer. The ORs varied according to time period and were significant during exposure in the household;For lung cancer, the OR was significant in women.Conclusion The effect of SHS exposure in China was similar to that in Western countries, but its definition and characterization require further clarification. Studies on the association between SHS exposure and certain diseases with high incidence rates are insufficient.展开更多
Introduction: The use of biomass for cooking is a very common practice in Africa and Benin, and is associated with exposure to organic pollutants. The aim of this study was to assess carbon monoxide exposure and respi...Introduction: The use of biomass for cooking is a very common practice in Africa and Benin, and is associated with exposure to organic pollutants. The aim of this study was to assess carbon monoxide exposure and respiratory disorders in women at artisanal fish-smoking sites. Methods: This was a cross-sectional study of women fish smokers at two artisanal fish-smoking sites in Benin. Recruitment was exhaustive. An interview using a respiratory questionnaire inspired by the Union questionnaire, spirometry and carbon monoxide (CO) measurement were carried out. Descriptive analysis and comparison of means using Student’s t-test with a threshold of p = 0.05 were performed. Results: The median age of the 81 people surveyed was 40, with an interquartile range (IQT) of [25 to 75]. The median duration of daily exposure to smoke was 6 h IQT [4, 7]. Of those surveyed, 64 (79.01%) were illiterate and 39 (48.24%) had been working for 20 years. CO levels at the start of activity varied from 89 to 145 ppm in one case and from 40 to 89 ppm in the other. Respiratory symptoms were present in 19 (23.46%);18 (22.22%) had mild airway impairment on spirometry. There was a statistically significant decrease between the mean values of peak expiratory flow (PEF), mean expiratory volume in seconds (FEV1) and forced vital capacity (FVC) before and after exposure to smoke. Conclusion: CO levels are high on fish smoking sites and respiratory problems are common. Improved working conditions are important for these women.展开更多
In order to improve the maintenance efficiency,extend the use time,ensure that the exhaust emission meets the standard,forthe 830E truck heating bucket exhaust pipe design defects,the current single smoke exhaust syst...In order to improve the maintenance efficiency,extend the use time,ensure that the exhaust emission meets the standard,forthe 830E truck heating bucket exhaust pipe design defects,the current single smoke exhaust system is transformed into atime period,convertible smoke exhaust system.After the transformation,it can not only realize the side row to prevent direct corrosion of the box bucket in summer,but also realize the heating of the box bucket at low temperature in winter to prevent snow and ice and frozen blocks from sticking to the box bucket and the materials transported.After the transformation can save a lot of manpower,material resources,financial resources,improve the service life.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.82060638)Academic and Technical Leaders of Major Disciplines in Jiangxi Province(Grant No.20194BCJ22032)
文摘Currently,cigarette smoke(CS)remains a major contributor to disease morbidity and mortality.CS can be divided into cigarette mainstream smoke(CMS)and side-stream smoke,depending on where it is produced by burning tobacco^([1]).CMS is inhaled by smokers from the filter end during cigarette combustion and is strongly associated with the development of several diseases^([2-4]).
基金National Natural Science Foundation of China,Grant/Award Numbers:72091512,52104198,52374210。
文摘The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels.
文摘The centralized smoke exhaust system of shield tunnel is an important determinant for tunnel fire safety,and the use of different design parameters of the tunnel smoke exhaust system will affect the smoke exhaust effect in the tunnel,and the influence of different design parameters on the smoke exhaust effect and temperature attenuation of the tunnel can help engineers in designing a more effective centralized smoke exhaust system for the tunnel.In this paper,the Fire Dynamic Simulator(FDS)is utilized to examine smoke exhaust vent settings for a centralized exhaust system in shield tunnel with both flat and sloped conditions,including slopes of+4.5%and−4.5%,under a 30MWfire power with a 150m^(3)/s smoke exhaust rate.The results suggest that maintaining a vent spacing of 60m and a vent size of 4.0 m×1.5 m is a reasonable configuration for centralized smoke exhaust systems in both flat and slope shield tunnels.This choice helpsminimize construction costs and prevent excessive smoke accumulation.It also promotes favorable conditions for maintaining temperature distribution at 2-m height,visibility,smoke spread distance,and temperature below the ceiling,all below the threshold values,while ensuring high smoke extraction efficiency.However,in the slope section,the chimney effect can disrupt exhaust efficiency,visibility,ceiling temperature,and temperature distribution at a height of 2 m.Employing different opening methods,such as having 2 vents up and 4 vents down in a+4.5%slope and 4 vents up and 2 vents down in a−4.5%slope,can help mitigate these effects.Furthermore,the temperature decay formula for shield tunnels follows a bi-exponential decay pattern,and different design parameters of centralized smoke exhaust systems have minimal effects on temperature decay in shield tunnels.
基金This work was supported byNatural Science Foundation of China(No.62362008,author Z.Z,https://www.nsfc.gov.cn/)Guizhou Provincial Science and Technology Projects(No.ZK[2022]149,author Z.Z,https://kjt.guizhou.gov.cn/)+2 种基金Guizhou Provincial Research Project(Youth)for Universities(No.[2022]104,author Z.Z,https://jyt.guizhou.gov.cn/)Natural Science Special Foundation of Guizhou University(No.[2021]47,author Z.Z,https://www.gzu.edu.cn/)GZU Cultivation Project of NSFC(No.[2020]80,author Z.Z,https://www.gzu.edu.cn/).
文摘In the rapidly evolving urban landscape,outdoor parking lots have become an indispensable part of the city’s transportation system.The growth of parking lots has raised the likelihood of spontaneous vehicle combus-tion,a significant safety hazard,making smoke detection an essential preventative step.However,the complex environment of outdoor parking lots presents additional challenges for smoke detection,which necessitates the development of more advanced and reliable smoke detection technologies.This paper addresses this concern and presents a novel smoke detection technique designed for the demanding environment of outdoor parking lots.First,we develop a novel dataset to fill the gap,as there is a lack of publicly available data.This dataset encompasses a wide range of smoke and fire scenarios,enhanced with data augmentation to ensure robustness against diverse outdoor conditions.Second,we utilize an optimized YOLOv5s model,integrated with the Squeeze-and-Excitation Network(SENet)attention mechanism,to significantly improve detection accuracy while maintaining real-time processing capabilities.Third,this paper implements an outdoor smoke detection system that is capable of accurately localizing and alerting in real time,enhancing the effectiveness and reliability of emergency response.Experiments show that the system has a high accuracy in terms of detecting smoke incidents in outdoor scenarios.
文摘This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under different conditions,including variations in heat release rates,exhaust volumetric flow rates,spacing between smoke outlets,and the longitudinal fire source positions.Results indicate that altering the fire source positions and the smoke outlets in the tunnel leads to variations in the properties of smoke flow both the fire source upstream and downstream;the distance between fire source and smoke outlet increases gradually,airflow rate decreases initially and eventually reaches a stable state.Similarly,smoke mass flow rate exhibits an increasing trend that eventually reaches a stable state.Moreover,the heat exchange between the tunnel walls and hot smoke increases as the smoke outlet moves further away from the fire source.This interaction leads to a reduction in the heat exhaust coefficient and a decrease in the distance the smoke spreads.This study investigates the impact of altering the relative longitudinal fire source positions and smoke outlet on smoke flow characteristics by numerical simulation.A theoretical analytical method is used to give a predictive model for the heat exhaust coefficient and the smoke spreading distance.This research can support the theory and technical process of tunnel smoke exhaust prevention and control.
文摘Industrial activities, through the human-induced release of Green House Gas (GHG) emissions, have beenidentified as the primary cause of global warming. Accurate and quantitative monitoring of these emissions isessential for a comprehensive understanding of their impact on the Earth’s climate and for effectively enforcingemission regulations at a large scale. This work examines the feasibility of detecting and quantifying industrialsmoke plumes using freely accessible geo-satellite imagery. The existing systemhas so many lagging factors such aslimitations in accuracy, robustness, and efficiency and these factors hinder the effectiveness in supporting timelyresponse to industrial fires. In this work, the utilization of grayscale images is done instead of traditional colorimages for smoke plume detection. The dataset was trained through a ResNet-50 model for classification and aU-Net model for segmentation. The dataset consists of images gathered by European Space Agency’s Sentinel-2 satellite constellation from a selection of industrial sites. The acquired images predominantly capture scenesof industrial locations, some of which exhibit active smoke plume emissions. The performance of the abovementionedtechniques and models is represented by their accuracy and IOU (Intersection-over-Union) metric.The images are first trained on the basic RGB images where their respective classification using the ResNet-50model results in an accuracy of 94.4% and segmentation using the U-Net Model with an IOU metric of 0.5 andaccuracy of 94% which leads to the detection of exact patches where the smoke plume has occurred. This work hastrained the classification model on grayscale images achieving a good increase in accuracy of 96.4%.
文摘Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal of the tunnel follows aW-shaped distribution.The congestion situation does not allowfor immediate longitudinal smoke exhaust at the early stage of the fire,and the natural spread of smoke is complicated.An exhaustive investigation was carried out to analyze the smoke behaviors during a fire incident,employing the fire dynamics software FDS,considering five slopes and four fire locations.The simulation results reveal that the layer of high-temperature smoke becomes thicker as one gets closer to the fire source.The thermal pressure difference significantly impacts the temperature distribution within the tunnel and the distance of smoke spread.The value of the thermal pressure difference is significantly affected by changes in slope.It reaches a maximum of 157 Pa at a 5%slope,while it is only 41 Pa at a 1%slope when the fire occurs at the V-point.Fire hazards vary across locations within the W-shaped tunnel,necessitating separate consideration of the V-point and inverted V-point fire characteristics.The mass flow rate in small and large slope tunnels shows different decay rates due to variations in the main forces acting on the movement.Hence,two equations have been developed to predict the smoke mass flow rate,indicating a nonlinear relationship with the tunnel slope and the distance fromthe fire source.The tunnel slope inversely affects the smoke mass flowrate at the same location.The results can be utilized as a reference for conducting evacuation operations and aiding rescues during aW-shaped tunnel fire.
文摘Chronic obstructive pulmonary disease(COPD)is a multifaceted syndrome characterized by a dysregulated inflammatory cascade within the respiratory system,primarily triggered by exposure to harmful particles and gases,notably from cigarette smoke.This inflammatory response is orchestrated by innate immune cells like macrophages and epithelial cells,which recognize danger signals released from damaged cells.Prolonged inflammation prompts an adaptive immune reaction mediated by dendritic cells,culminating in the formation of lymphoid follicles and involving a complex interplay of T and B cells,as well as cytotoxic activity.Additionally,both viral and bacterial infections exacerbate COPD by further igniting inflammatory pathways,perpetuating the chronic inflammatory state.This comprehensive review encapsulates the intricate interplay between innate and adaptive immunity in COPD,with a particular focus on the role of cigarette smoke in its pathogenesis and potential therapeutic targets.
文摘The United Kingdom may soon become a world leader in forging a smoke-free generation.Last month,the country passed a bill that bans the sale of cigarettes to anyone born in 2009 or later.The prime minister claims the policy will"phase out smoking in young people almost completely as early as 2040."A final vote by Parliament is expected next month.Tobacco claims 8 million lives every year,and could claim a billion lives over this century-mostly in low-and middle-income countries.For every person that dies,at least 30 more suffer from smokingrelated chronic disease.The benefits of a tobacco-free society would be transformational.
基金supported by the CAMS Innovation Fund for Medical Sciences[CIFMS2016-12M-3-001]the China Medical Board Strengthen Capacity of Study and Application on Burden of Disease in Health Care System of China-Establishment and Development of Chinese Burden of Disease Research and Dissemination Center[15-208]。
文摘Objective This study assesses the impact of smoke-free legislation on the incidence rate for acute myocardial infarction(AMI)and stroke in Shenzhen.Methods Data on ischemic(n=72,945)and hemorrhagic(n=18,659)stroke and AMI(n=17,431)incidence covering about 12 million people in Shenzhen from 2012 to 2016 were used.Immediate and gradual changes in incidence rates were analyzed using segmented Poisson regression.Results Following the smoke-free legislation,a 9%(95%CI:3%-15%)immediate reduction was observed in AMI incidence,especially in men(8%,95%CI:1%-14%)and in those aged 65 years and older(17%,95%CI:9%-25%).The gradual annual benefits were observed only in hemorrhagic and ischemic stroke incidence,with a 7%(95%CI:2%-11%)and 6%(95%CI:4%-8%)decrease per year,respectively.This health effect extended gradually to the 50-64 age group.In addition,neither the immediate nor gradual decrease in stroke and AMI incidence rates did not show statistical significance among the 35-49 age group(P>0.05).Conclusion Smoke-free legislation was enforced well in Shenzhen,which would generate good experiences for other cities to enact and enforce smoke-free laws.This study also provided more evidence of the health benefits of smoke-free laws on stroke and AMI.
基金supported by the Chinese Academy of Medical Sciences(CAMS)Innovation Fund for Medical Sciences(CIFM)[NO.2016-12M-3-001]the China Medical Board“Strengthen Capacity of Study and Application on Burden of Disease in Health Care System of China-Establishment and Development of Chinese Burden of Disease Research and Dissemination Center”[NO.15-208]。
文摘Objective To analyze the association between exposure to second-hand smoke(SHS) and 23 diseases,categorized into four classifications, among the Chinese population.Methods We searched the literature up to June 30, 2021, and eligible studies were identified according to the PECOS format: Participants and Competitors(Chinese population), Exposure(SHS),Outcomes(Disease or Death), and Study design(Case-control or Cohort).Results In total, 53 studies were selected. The odds ratio(OR) for all types of cancer was 1.79(1.56–2.05), and for individual cancers was 1.92(1.42–2.59) for lung cancer, 1.57(1.40–1.76) for breast cancer, 1.52(1.12–2.05) for bladder cancer, and 1.37(1.08–1.73) for liver cancer. The OR for circulatory system diseases was 1.92(1.29–2.85), with a value of 2.29(1.26–4.159) for stroke. The OR of respiratory system diseases was 1.76(1.13–2.74), with a value of 1.82(1.07–3.11) for childhood asthma. The original ORs were also shown for other diseases. Subgroup analyses were performed for lung and breast cancer. The ORs varied according to time period and were significant during exposure in the household;For lung cancer, the OR was significant in women.Conclusion The effect of SHS exposure in China was similar to that in Western countries, but its definition and characterization require further clarification. Studies on the association between SHS exposure and certain diseases with high incidence rates are insufficient.
文摘Introduction: The use of biomass for cooking is a very common practice in Africa and Benin, and is associated with exposure to organic pollutants. The aim of this study was to assess carbon monoxide exposure and respiratory disorders in women at artisanal fish-smoking sites. Methods: This was a cross-sectional study of women fish smokers at two artisanal fish-smoking sites in Benin. Recruitment was exhaustive. An interview using a respiratory questionnaire inspired by the Union questionnaire, spirometry and carbon monoxide (CO) measurement were carried out. Descriptive analysis and comparison of means using Student’s t-test with a threshold of p = 0.05 were performed. Results: The median age of the 81 people surveyed was 40, with an interquartile range (IQT) of [25 to 75]. The median duration of daily exposure to smoke was 6 h IQT [4, 7]. Of those surveyed, 64 (79.01%) were illiterate and 39 (48.24%) had been working for 20 years. CO levels at the start of activity varied from 89 to 145 ppm in one case and from 40 to 89 ppm in the other. Respiratory symptoms were present in 19 (23.46%);18 (22.22%) had mild airway impairment on spirometry. There was a statistically significant decrease between the mean values of peak expiratory flow (PEF), mean expiratory volume in seconds (FEV1) and forced vital capacity (FVC) before and after exposure to smoke. Conclusion: CO levels are high on fish smoking sites and respiratory problems are common. Improved working conditions are important for these women.
基金2022 Liaoning Natural Science Foundation Plan(Yingkou Joint Fund)Damping damping Design and Optimization of New Bore Head Transmission Structure(Fund No.:2022-YKLH-17)In 2023,the key scientific research project of Yingkou Institute of Technology is the Design and Optimization of Smoke Drainage Pipe for New Mining Truck(Fund No.:ZDIL202306)2021 Natural Science Foundation of Liaoning Province(Yingkou Joint Fund)Research on Dynamic Characteristics of Damped Dynamic Reduction Vertical Holack(Fund No.:2021-YKLH-08).
文摘In order to improve the maintenance efficiency,extend the use time,ensure that the exhaust emission meets the standard,forthe 830E truck heating bucket exhaust pipe design defects,the current single smoke exhaust system is transformed into atime period,convertible smoke exhaust system.After the transformation,it can not only realize the side row to prevent direct corrosion of the box bucket in summer,but also realize the heating of the box bucket at low temperature in winter to prevent snow and ice and frozen blocks from sticking to the box bucket and the materials transported.After the transformation can save a lot of manpower,material resources,financial resources,improve the service life.