This paper proposes a new upper-limb exoskeleton to reduce worker physical strain.The proposed design is based on a novel PRRRP(P-Prismatic;R-Revolute)kinematic chain with 5 passive Degrees of Freedom(DoF).Utilizing a...This paper proposes a new upper-limb exoskeleton to reduce worker physical strain.The proposed design is based on a novel PRRRP(P-Prismatic;R-Revolute)kinematic chain with 5 passive Degrees of Freedom(DoF).Utilizing a magnetic spring,the proposed mechanism includes a specially designed locking mechanism that maintains any desired task posture.The proposed exoskeleton incorporates a balancing mechanism to alleviate discomfort and spinal torsional effects also helping in limb weight relief.This paper reports specific models and simulations to demonstrate the feasibility and effectiveness of the proposed design.An experimental characterization is performed to validate the performance of the mechanism in terms of forces and physical strain during a specific application consisting of ceiling-surface drilling tasks.The obtained results preliminarily validate the engineering feasibility and effectiveness of the proposed exoskeleton in the intended operation task thereby requiring the user to exert significantly less force than when not wearing it.展开更多
Valleytronics is an emerging field of research which utilizes the valley degree of freedom to encode information.However,it is technically nontrivial to produce a stable valley polarization and to achieve efficient co...Valleytronics is an emerging field of research which utilizes the valley degree of freedom to encode information.However,it is technically nontrivial to produce a stable valley polarization and to achieve efficient control and manipulation of valleys.Spin–valley locking refers to the coupling between spin and valley degrees of freedom in the materials with large spin–orbit coupling(SOC)and enables the manipulation of valleys indirectly through controlling spins.Here,we review the recent advances in spin–valley locking physics and outline possible device implications.In particular,we focus on the spin–valley locking induced by SOC and external electric field in certain two-dimensional materials with inversion symmetry and demonstrate the intriguing switchable valley–spin polarization,which can be utilized to design the promising electronic devices,namely,valley-spin valves and logic gates.展开更多
BACKGROUND Osteochondroma is one of the most common benign bone tumors,and it may cause bone and joint deformities and limited range of motion of an adjacent joint.The pes anserinus region is one of the most frequent ...BACKGROUND Osteochondroma is one of the most common benign bone tumors,and it may cause bone and joint deformities and limited range of motion of an adjacent joint.The pes anserinus region is one of the most frequent sites of osteochondroma,but knee locking caused by osteochondromas in the pes anserinus region is extremely rare.CASE SUMMARY We describe a 13-year-old Japanese girl’s extra-articular knee locking that occurred when the semitendinosus tendon got caught in osteochondroma that had developed in the pes anserinus region.The osteochondroma was surgically resected.The postoperative outcome has been excellent,with no recurrence of knee locking or tumor one-year post-surgery.CONCLUSION When a young person develops knee locking,the possibility of extra-articular as well as intra-articular locking should be considered.Osteochondroma,one of the causes of extra-articular locking,can be treated with surgery with good postoperative results.展开更多
BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixati...BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixation is the treatment of choice among orthopaedics.Conventional plates allow stability of the fracture if bone quality is present.Locking plates might offer an advantage for the treatment of lateral malleolar fracture in patients with comminution,severe instability,distal fractures,or osteoporotic bone.Our hospital introduced a new locking plate for fracture of the distal fibula.AIM To evaluate locking plates in terms of outcomes and complications in young and elderly patients.METHODS We retrospectively reviewed a total of 67 patients treated for displaced distal fibula fractures.Demographic data,number of comorbidities,use of inter fragmentary screw,complication,time of fracture healing,partial or full weight bearing,and reoperation were recorded for all patients.Clinical outcome was assessed by the American Orthopedic Foot and Ankle Society clinical scoring system.Radiographs were obtained at 4,8,12,16,20,and 24 wk until radiographic union was obtained.RESULTS All patients displayed complete bony union on radiographic assessment,and no patients developed any serious complications.We observed two superficial infections,one delayed wound healing,and two plate intolerances.Significant differences were observed between the two age groups in terms of radiographic healing(11.9 wk in younger patients vs 13.7 wk in older patients;P=0.011)and in the American Orthopedic Foot and Ankle Society score at 6 mo after surgery(88.2 in younger patients vs 86.0 in older patients;P=0.001)and at 12 mo after surgery(92.6 in younger patients vs 90.0 in older patients;P=0.000).CONCLUSION Locking plates provide a stable and rigid fixation in multifragmentary and comminuted fractures or in the presence of poor bone quality.展开更多
Triggering,locking,clicking,and crepitus of the fingers are common symptoms patients present with.Even though crepitus and triggering can occur as part of the same underlying diagnosis,it is important to differentiate...Triggering,locking,clicking,and crepitus of the fingers are common symptoms patients present with.Even though crepitus and triggering can occur as part of the same underlying diagnosis,it is important to differentiate between them,as they usually indicate different possible diagnoses.The differential diagnoses that should be considered include trigger finger,metacarpophalangeal joint(MCPJ)arthritis,fractures or dislocations,extensor digitorum communis subluxation or dislocation,locked MCPJ,avascular necrosis of the metacarpal head,and Dupuytren’s disease.A thorough clinical examination with appropriate special investigations can permit the clinician to make the correct diagnosis.Appropriate management of a confirmed diagnosis is successful in providing symptomatic improvement.展开更多
Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.B...Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.Beavis II fracture has large bone fracture,obvious displacement,obvious soft tissue irritation,and often leads to skin necrosis.It needs surgical treatment,reduction and fixation as soon as possible.Although open reduction and tension screw internal fixation is used for Beavis II calcaneal tubercle fracture,but the failure rate is more common.Methods:This study retrospectively analyzed the surgical treatment of calcaneal tubercle Beavis II fracture over 55 years old in our hospital from January 2013 to January 2019.The patients were treated with tension screw combined with locking plate,and followed up and analyzed.Results:12 patients in this group were followed up for 12 to 36 months(mean 20 months).After operation,the fracture healed smoothly in all patients,the healing time was 8 to 12 weeks(mean 10.7 weeks),and there were no complications such as poor incision healing,fracture displacement,internal fixation loosening,fracture and so on.When the patients were followed up 18 weeks after operation,the AOFAS score was 47 to 100,with an average of 91.1,of which 8 cases were excellent,3 good and 1 poor,with an excellent and good rate of 91.7%.Conclusion:Our hospital has been treated with tension screw combined with locking plate,fixed firmly,can early functional exercise,achieved good results.展开更多
We present a compact injection-locking diode laser module to generate 671 nm laser light with a high output power up to 150 m W.The module adopts a master-slave injection-locking scheme,and the injection-locking state...We present a compact injection-locking diode laser module to generate 671 nm laser light with a high output power up to 150 m W.The module adopts a master-slave injection-locking scheme,and the injection-locking state is monitored using the transmission spectrum from a Fabry-Perot interferometer.Beat frequency spectrum measurement shows that the injection-locked slave laser has no other frequency components within the 150-MHz detection bandwidth.It is found that without additional electronic feedback,the slave laser can follow the master laser over a wide range of 6 GHz.All the elements of the module are commercially available,which favors fast construction of a complete 671-nm laser system for the preparation of cold^(6)Li atoms with only one research-grade diode laser as the seeding source.展开更多
The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus ...The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus nailing locking options in the conventional nailing systems are placed in the anterior-posterior and lateral-medial directions. It exposes both the patient and surgeon to radiation, is time consuming, and has a potential risk of damaging neurovascular structures, especially the radial and lateral cutaneous nerve when the anterior-posterior and lateral-medial locking constructs are used. We aim to present a technical tip to ease the distal locking procedure and avoid the possible neurovascular complications with the existing nailing systems.展开更多
Background: Since we are very successful in the operation of hallux valgus using a transverse sub-capital osteotomy fixated with an intramedullary angle-stable locking plate, and a tailors bunion is understood as a re...Background: Since we are very successful in the operation of hallux valgus using a transverse sub-capital osteotomy fixated with an intramedullary angle-stable locking plate, and a tailors bunion is understood as a reversed hallux valgus, we have applied the operation also for such indication. Method: The osteotomy was carried out at a straight V. metatarsal subcapitally, and in case of an outwardly curved V. metatarsal at the bending location. The intramedullary plates are available in different designs and the plate and screws disappear completely in the bone, so the soft tissues are not disturbed. The head of the plate is either straight or curved in order to shift the distal fragment sufficiently. Results: 26 patients were operated within a period of 5 years (2008-2012). 21 patients were followed up after an average of 34.4 months. The IM angle IV/V could be improved by an average of 11.76 to an average of 4.10. This is a highliy significant pre- to postoperative difference of 7.66 (t = 15.07, p < 0.001). The AOFAS score was improved by an average of 42.24 points from 55.76 points preoperatively to 98.00 points postoperative. There was no pseudo-arthrosis and no wound healing impairment. All patients were either satisfied or very satisfied with the surgery. Conclusion: This method does not have the disadvantages of the other common operations of the Tailors bunion and is applied now as a standard method in this deformity.展开更多
AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necess...AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n = 29), or another treatment modality(n = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk. Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE) Score; Disabilities of the Arm, Shoulder and Hand and activities of daily living(ADLs). Clinical outcomes were wrist range of motion and grip strength. Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores, ADL scores, grip strength and range of extension at three months compared with the control group. All radiological parameters were significantly better in the volar locking plate group at 3 mo. CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities. Anatomical reduction was significantly more likely to be preserved in the plating group. Level of evidence: Ⅱ.展开更多
Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in dif...Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications.展开更多
AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fr...AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.展开更多
AIM: To review the results of our experience with the Medartis Aptus plating system for four corner arthrodesis of the wrist, which uses a combination of compression screws and variable angle locking screws.METHODS: W...AIM: To review the results of our experience with the Medartis Aptus plating system for four corner arthrodesis of the wrist, which uses a combination of compression screws and variable angle locking screws.METHODS: We reviewed the results of 17 procedures in 16 patients that underwent scaphoid excision and four corner fusion using the Medartis Aptus system between May 2010 and June 2014. The primary outcome measure was radiographic and clinical union. RESULTS: The mean clinical follow up time was 20.6 mo. The mean union time was 6 mo. Two non-unions required revision procedures. The mean disabilities of the arm, shoulder and hand score taken after union was 36. The mean final grip strength was 27 kg. The mean final range of movement was 30° flexion and 31° of extension. All patients had a restored scapholunate angle on postoperative radiographs. There were no incidences of dorsal impingement.CONCLUSION: Overall our experience with the Aptus plating system shows comparable results to other methods of fixation for four corner fusion, in the short to medium term.展开更多
Coherent beam combining(CBC)is an efficient way to scale the brightness of laser arrays.We demonstrate the active phase locking CBC of two slab laser amplifiers based on the multi-dithering technique.The experimental ...Coherent beam combining(CBC)is an efficient way to scale the brightness of laser arrays.We demonstrate the active phase locking CBC of two slab laser amplifiers based on the multi-dithering technique.The experimental investigation on the 102 W coherent beam combining of two slab amplifiers shows that the whole system in a closed loop performs well over a long time observation.The contrast of the coherent combined beam profile is about 87%and the combining efficiency is nearly 85%.In addition,the CBC of two green lasers is realized based on the second-harmonic generation of the phase locking pump lasers.To the best of our knowledge,this is the first report about second-harmonic active phase locking,which indicates further potential applications of CBC.展开更多
Introduction: Totally implantable venous access port (TIVAP) is essential prerequisite for most of chemotherapy protocols. Flushing with 0.9% sodium chloride becomes an alternative to heparinized solution. As flushing...Introduction: Totally implantable venous access port (TIVAP) is essential prerequisite for most of chemotherapy protocols. Flushing with 0.9% sodium chloride becomes an alternative to heparinized solution. As flushing and locking solutions are still controversial, this study was conducted to compare efficacy of heparinized solution versus normal saline solution for locking in ports TIVAP. Patients and Methods: Prospective Cohort study performed in teaching hospital Sulaymaniyah-University of Kurdistan, Iraq, including 384 TIVAP implanted in cancer and non-cancer patients. The study reports the TIVAP outcome in 2 groups of patients where 2 different solutions used for maintaining catheter’s patency by heparinized solution in group (A), versus normal saline for group (B). Results: In group A, the rate of complications was 8.2% (n = 16) while in group B complications rate was 7.9% (n = 15). Thrombosis in group A occurred in 1.03% of the cases and in group B was 1.57%. There were no significant differences between the two groups regarding the causes for unwanted removals of the TIVAP. Conclusions: The results of our study suggest that heparin has no role in preventing the early or late complications of TIVAP and we do not recommend using it as a locking solution.展开更多
Background: Supracutaneous plating using a locking compression plate (LCP) as an external fixator in compound periarticular areas is facilitated by the development of anatomical plates. The soft tissue around the dist...Background: Supracutaneous plating using a locking compression plate (LCP) as an external fixator in compound periarticular areas is facilitated by the development of anatomical plates. The soft tissue around the distal tibia is easily compromised by trauma and subsequent operative fracture treatment posing a definitive challenge in the distal tibia compound fractures. The purpose of this report is to describe our successful results using the metaphyseal locking compression plate (LCP) as an external fixator in the treatment of Grade I & II compound fractures of distal tibia. Methodology: A total of five (05) patients underwent “supracutaneous plating” of the tibia using a metaphyseal locking compression plate. Average age was 36 years. Regular screw tract dressings were done. Average period of follow-up was 15 months. Results: The plate was in situ for an average of 24 weeks. There were no clinically significant screw site infections. In all five patients the plate was kept in place until there was complete consolidation both clinically and radiologically. At the latest follow-up (average 15 months), all patients were fully weight bearing with a fully healed tibia. All patients were infection-free with well-healed wounds. Conclusion: Routinely, after initial debridement and temporary bony stabilization is provided by external fixation in compound fractures of the distal tibia with significant soft tissue injury. Most external frames for the lower leg are bulky and cumbersome, causing significant problems for the patient. To circumvent these issues, we have successfully used an anatomically-contoured supracutaneous metaphyseal locking compression plate as external fixator in a series of five patients for grade I & II compound fracture of the distal tibia.展开更多
Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes...Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters.展开更多
Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability,...Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.展开更多
In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable the...In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is to determine whether distal femur locking plates are superior implants than dynamic condylar screw and distal femur nail. A prospective and observational study was done in Department of Orthopaedics and Traumatology, Sri Ramachandra Medical Collage, Chennai between Jan. 2011 and Jan. 2015. Patients with distal femoral fractures, admitted into the hospital, were treated using various modes of internal fixation and followed up over a period of six months to one year and their functional outcome was evaluated. The functional and radiological assessment of patients during follow-up was done using Neer’s criteria. The use of any one of the implant, i.e. distal femur locking plates, dynamic condylar screw or distal femur nailing for internal fixation, depends on the type of fracture and the pre operative planning and intra operate decision of the surgeon. In our study, 38% of fractures treated by Dynamic condylar screw, 72% of fractures treated by distal femur locking plate and 42% of fractures treated by Distal femur supracondylar nail had excellent/satisfactory results. Locking plates had better outcome in both extra-articular and intra-articular group. They also had better outcome in both younger and older age groups.展开更多
基金supported by the European Regional Development Fund and the Romanian Government through the Competitiveness Operational Programme 2014-2020project APOLLO,MySMIS code 155988,contract no.9/1.2.1-PTIap.2/23.02.2023.
文摘This paper proposes a new upper-limb exoskeleton to reduce worker physical strain.The proposed design is based on a novel PRRRP(P-Prismatic;R-Revolute)kinematic chain with 5 passive Degrees of Freedom(DoF).Utilizing a magnetic spring,the proposed mechanism includes a specially designed locking mechanism that maintains any desired task posture.The proposed exoskeleton incorporates a balancing mechanism to alleviate discomfort and spinal torsional effects also helping in limb weight relief.This paper reports specific models and simulations to demonstrate the feasibility and effectiveness of the proposed design.An experimental characterization is performed to validate the performance of the mechanism in terms of forces and physical strain during a specific application consisting of ceiling-surface drilling tasks.The obtained results preliminarily validate the engineering feasibility and effectiveness of the proposed exoskeleton in the intended operation task thereby requiring the user to exert significantly less force than when not wearing it.
基金supported by the Fundamental Research Funds for the Central Universities(Grant No.FRFCU5710053421)the National Natural Science Foundation of China(Grant No.12274102)。
文摘Valleytronics is an emerging field of research which utilizes the valley degree of freedom to encode information.However,it is technically nontrivial to produce a stable valley polarization and to achieve efficient control and manipulation of valleys.Spin–valley locking refers to the coupling between spin and valley degrees of freedom in the materials with large spin–orbit coupling(SOC)and enables the manipulation of valleys indirectly through controlling spins.Here,we review the recent advances in spin–valley locking physics and outline possible device implications.In particular,we focus on the spin–valley locking induced by SOC and external electric field in certain two-dimensional materials with inversion symmetry and demonstrate the intriguing switchable valley–spin polarization,which can be utilized to design the promising electronic devices,namely,valley-spin valves and logic gates.
文摘BACKGROUND Osteochondroma is one of the most common benign bone tumors,and it may cause bone and joint deformities and limited range of motion of an adjacent joint.The pes anserinus region is one of the most frequent sites of osteochondroma,but knee locking caused by osteochondromas in the pes anserinus region is extremely rare.CASE SUMMARY We describe a 13-year-old Japanese girl’s extra-articular knee locking that occurred when the semitendinosus tendon got caught in osteochondroma that had developed in the pes anserinus region.The osteochondroma was surgically resected.The postoperative outcome has been excellent,with no recurrence of knee locking or tumor one-year post-surgery.CONCLUSION When a young person develops knee locking,the possibility of extra-articular as well as intra-articular locking should be considered.Osteochondroma,one of the causes of extra-articular locking,can be treated with surgery with good postoperative results.
文摘BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixation is the treatment of choice among orthopaedics.Conventional plates allow stability of the fracture if bone quality is present.Locking plates might offer an advantage for the treatment of lateral malleolar fracture in patients with comminution,severe instability,distal fractures,or osteoporotic bone.Our hospital introduced a new locking plate for fracture of the distal fibula.AIM To evaluate locking plates in terms of outcomes and complications in young and elderly patients.METHODS We retrospectively reviewed a total of 67 patients treated for displaced distal fibula fractures.Demographic data,number of comorbidities,use of inter fragmentary screw,complication,time of fracture healing,partial or full weight bearing,and reoperation were recorded for all patients.Clinical outcome was assessed by the American Orthopedic Foot and Ankle Society clinical scoring system.Radiographs were obtained at 4,8,12,16,20,and 24 wk until radiographic union was obtained.RESULTS All patients displayed complete bony union on radiographic assessment,and no patients developed any serious complications.We observed two superficial infections,one delayed wound healing,and two plate intolerances.Significant differences were observed between the two age groups in terms of radiographic healing(11.9 wk in younger patients vs 13.7 wk in older patients;P=0.011)and in the American Orthopedic Foot and Ankle Society score at 6 mo after surgery(88.2 in younger patients vs 86.0 in older patients;P=0.001)and at 12 mo after surgery(92.6 in younger patients vs 90.0 in older patients;P=0.000).CONCLUSION Locking plates provide a stable and rigid fixation in multifragmentary and comminuted fractures or in the presence of poor bone quality.
文摘Triggering,locking,clicking,and crepitus of the fingers are common symptoms patients present with.Even though crepitus and triggering can occur as part of the same underlying diagnosis,it is important to differentiate between them,as they usually indicate different possible diagnoses.The differential diagnoses that should be considered include trigger finger,metacarpophalangeal joint(MCPJ)arthritis,fractures or dislocations,extensor digitorum communis subluxation or dislocation,locked MCPJ,avascular necrosis of the metacarpal head,and Dupuytren’s disease.A thorough clinical examination with appropriate special investigations can permit the clinician to make the correct diagnosis.Appropriate management of a confirmed diagnosis is successful in providing symptomatic improvement.
基金the Youth Science and Technology Project of Health Commission of Shanghai Pudong New Area(Project no.PW2020B-5)the Outstanding Clinical Discipline Project of Shanghai Pudong(Grant No.PWYgy2021-04)+4 种基金the Health Industry Clinical Research Project of Shanghai Health Commission(Project no.20224Y0393)the Young Medical Talents Training Program of Pudong Health Committee of Shanghai(Grant No.PWRq 2021-08)the Outstanding Leaders Training Program of Pudong Hospital affiliated to Fudan University(Grant No.LX202201)the Talents Training Program of Pudong Hospital affiliated to Fudan University(Project no.PX202001)the Scientific Research Foundation provided by Pudong Hospital affiliated to Fudan University(Project no.YJRCJJ201906).
文摘Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.Beavis II fracture has large bone fracture,obvious displacement,obvious soft tissue irritation,and often leads to skin necrosis.It needs surgical treatment,reduction and fixation as soon as possible.Although open reduction and tension screw internal fixation is used for Beavis II calcaneal tubercle fracture,but the failure rate is more common.Methods:This study retrospectively analyzed the surgical treatment of calcaneal tubercle Beavis II fracture over 55 years old in our hospital from January 2013 to January 2019.The patients were treated with tension screw combined with locking plate,and followed up and analyzed.Results:12 patients in this group were followed up for 12 to 36 months(mean 20 months).After operation,the fracture healed smoothly in all patients,the healing time was 8 to 12 weeks(mean 10.7 weeks),and there were no complications such as poor incision healing,fracture displacement,internal fixation loosening,fracture and so on.When the patients were followed up 18 weeks after operation,the AOFAS score was 47 to 100,with an average of 91.1,of which 8 cases were excellent,3 good and 1 poor,with an excellent and good rate of 91.7%.Conclusion:Our hospital has been treated with tension screw combined with locking plate,fixed firmly,can early functional exercise,achieved good results.
基金the National Natural Science Foundation of China(Grant Nos.12035006,12205095,and12147219)the Natural Science Foundation of Zhejiang Province(Grant No.LQ21A040001)。
文摘We present a compact injection-locking diode laser module to generate 671 nm laser light with a high output power up to 150 m W.The module adopts a master-slave injection-locking scheme,and the injection-locking state is monitored using the transmission spectrum from a Fabry-Perot interferometer.Beat frequency spectrum measurement shows that the injection-locked slave laser has no other frequency components within the 150-MHz detection bandwidth.It is found that without additional electronic feedback,the slave laser can follow the master laser over a wide range of 6 GHz.All the elements of the module are commercially available,which favors fast construction of a complete 671-nm laser system for the preparation of cold^(6)Li atoms with only one research-grade diode laser as the seeding source.
文摘The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus nailing locking options in the conventional nailing systems are placed in the anterior-posterior and lateral-medial directions. It exposes both the patient and surgeon to radiation, is time consuming, and has a potential risk of damaging neurovascular structures, especially the radial and lateral cutaneous nerve when the anterior-posterior and lateral-medial locking constructs are used. We aim to present a technical tip to ease the distal locking procedure and avoid the possible neurovascular complications with the existing nailing systems.
文摘Background: Since we are very successful in the operation of hallux valgus using a transverse sub-capital osteotomy fixated with an intramedullary angle-stable locking plate, and a tailors bunion is understood as a reversed hallux valgus, we have applied the operation also for such indication. Method: The osteotomy was carried out at a straight V. metatarsal subcapitally, and in case of an outwardly curved V. metatarsal at the bending location. The intramedullary plates are available in different designs and the plate and screws disappear completely in the bone, so the soft tissues are not disturbed. The head of the plate is either straight or curved in order to shift the distal fragment sufficiently. Results: 26 patients were operated within a period of 5 years (2008-2012). 21 patients were followed up after an average of 34.4 months. The IM angle IV/V could be improved by an average of 11.76 to an average of 4.10. This is a highliy significant pre- to postoperative difference of 7.66 (t = 15.07, p < 0.001). The AOFAS score was improved by an average of 42.24 points from 55.76 points preoperatively to 98.00 points postoperative. There was no pseudo-arthrosis and no wound healing impairment. All patients were either satisfied or very satisfied with the surgery. Conclusion: This method does not have the disadvantages of the other common operations of the Tailors bunion and is applied now as a standard method in this deformity.
文摘AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n = 29), or another treatment modality(n = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk. Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE) Score; Disabilities of the Arm, Shoulder and Hand and activities of daily living(ADLs). Clinical outcomes were wrist range of motion and grip strength. Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores, ADL scores, grip strength and range of extension at three months compared with the control group. All radiological parameters were significantly better in the volar locking plate group at 3 mo. CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities. Anatomical reduction was significantly more likely to be preserved in the plating group. Level of evidence: Ⅱ.
文摘Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications.
文摘AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.
文摘AIM: To review the results of our experience with the Medartis Aptus plating system for four corner arthrodesis of the wrist, which uses a combination of compression screws and variable angle locking screws.METHODS: We reviewed the results of 17 procedures in 16 patients that underwent scaphoid excision and four corner fusion using the Medartis Aptus system between May 2010 and June 2014. The primary outcome measure was radiographic and clinical union. RESULTS: The mean clinical follow up time was 20.6 mo. The mean union time was 6 mo. Two non-unions required revision procedures. The mean disabilities of the arm, shoulder and hand score taken after union was 36. The mean final grip strength was 27 kg. The mean final range of movement was 30° flexion and 31° of extension. All patients had a restored scapholunate angle on postoperative radiographs. There were no incidences of dorsal impingement.CONCLUSION: Overall our experience with the Aptus plating system shows comparable results to other methods of fixation for four corner fusion, in the short to medium term.
基金by the Innovation Foundation for Graduates in National University of Defense Technology under Grant B090704the Hunan Provincial Innovation Foundation For Postgraduate(No CX2009B006).
文摘Coherent beam combining(CBC)is an efficient way to scale the brightness of laser arrays.We demonstrate the active phase locking CBC of two slab laser amplifiers based on the multi-dithering technique.The experimental investigation on the 102 W coherent beam combining of two slab amplifiers shows that the whole system in a closed loop performs well over a long time observation.The contrast of the coherent combined beam profile is about 87%and the combining efficiency is nearly 85%.In addition,the CBC of two green lasers is realized based on the second-harmonic generation of the phase locking pump lasers.To the best of our knowledge,this is the first report about second-harmonic active phase locking,which indicates further potential applications of CBC.
文摘Introduction: Totally implantable venous access port (TIVAP) is essential prerequisite for most of chemotherapy protocols. Flushing with 0.9% sodium chloride becomes an alternative to heparinized solution. As flushing and locking solutions are still controversial, this study was conducted to compare efficacy of heparinized solution versus normal saline solution for locking in ports TIVAP. Patients and Methods: Prospective Cohort study performed in teaching hospital Sulaymaniyah-University of Kurdistan, Iraq, including 384 TIVAP implanted in cancer and non-cancer patients. The study reports the TIVAP outcome in 2 groups of patients where 2 different solutions used for maintaining catheter’s patency by heparinized solution in group (A), versus normal saline for group (B). Results: In group A, the rate of complications was 8.2% (n = 16) while in group B complications rate was 7.9% (n = 15). Thrombosis in group A occurred in 1.03% of the cases and in group B was 1.57%. There were no significant differences between the two groups regarding the causes for unwanted removals of the TIVAP. Conclusions: The results of our study suggest that heparin has no role in preventing the early or late complications of TIVAP and we do not recommend using it as a locking solution.
文摘Background: Supracutaneous plating using a locking compression plate (LCP) as an external fixator in compound periarticular areas is facilitated by the development of anatomical plates. The soft tissue around the distal tibia is easily compromised by trauma and subsequent operative fracture treatment posing a definitive challenge in the distal tibia compound fractures. The purpose of this report is to describe our successful results using the metaphyseal locking compression plate (LCP) as an external fixator in the treatment of Grade I & II compound fractures of distal tibia. Methodology: A total of five (05) patients underwent “supracutaneous plating” of the tibia using a metaphyseal locking compression plate. Average age was 36 years. Regular screw tract dressings were done. Average period of follow-up was 15 months. Results: The plate was in situ for an average of 24 weeks. There were no clinically significant screw site infections. In all five patients the plate was kept in place until there was complete consolidation both clinically and radiologically. At the latest follow-up (average 15 months), all patients were fully weight bearing with a fully healed tibia. All patients were infection-free with well-healed wounds. Conclusion: Routinely, after initial debridement and temporary bony stabilization is provided by external fixation in compound fractures of the distal tibia with significant soft tissue injury. Most external frames for the lower leg are bulky and cumbersome, causing significant problems for the patient. To circumvent these issues, we have successfully used an anatomically-contoured supracutaneous metaphyseal locking compression plate as external fixator in a series of five patients for grade I & II compound fracture of the distal tibia.
文摘Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters.
文摘Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.
文摘In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is to determine whether distal femur locking plates are superior implants than dynamic condylar screw and distal femur nail. A prospective and observational study was done in Department of Orthopaedics and Traumatology, Sri Ramachandra Medical Collage, Chennai between Jan. 2011 and Jan. 2015. Patients with distal femoral fractures, admitted into the hospital, were treated using various modes of internal fixation and followed up over a period of six months to one year and their functional outcome was evaluated. The functional and radiological assessment of patients during follow-up was done using Neer’s criteria. The use of any one of the implant, i.e. distal femur locking plates, dynamic condylar screw or distal femur nailing for internal fixation, depends on the type of fracture and the pre operative planning and intra operate decision of the surgeon. In our study, 38% of fractures treated by Dynamic condylar screw, 72% of fractures treated by distal femur locking plate and 42% of fractures treated by Distal femur supracondylar nail had excellent/satisfactory results. Locking plates had better outcome in both extra-articular and intra-articular group. They also had better outcome in both younger and older age groups.