期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
IDENTIFICATION OF DOUBLE BOND POSITION IN HEXADECENYL ACETATES BY MASS SPECTROMETRY
1
作者 Gu YUAN a Department of Chemistry,Peking University,Beijing,100871Michio HORIIKE Chisato HIRANO b Department of Agricultural Chemistry,Kochi University,Nankoku-shi 783,Japan 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第4期351-352,共2页
A method for locating double bond in hexadecenyl acetates has been developed by analyzing the mass spectral patterns on a fuzzy classification. The procedure was tested with the spectra of Δ~2- to Δ^(15)-isomers and... A method for locating double bond in hexadecenyl acetates has been developed by analyzing the mass spectral patterns on a fuzzy classification. The procedure was tested with the spectra of Δ~2- to Δ^(15)-isomers and the original double-bond position in these acetates was located unambiguously. 展开更多
关键词 identification OF DOUBLE BOND POSITION IN HEXADECENYL ACETATES BY mass SPECTROMETRY
下载PDF
Thruster direction controlling of assembled spacecraft based on gimbal suspension
2
作者 Hongliang Xu Hai Huang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2016年第2期442-448,共7页
The attitude control system design and its control effect are affected considerably by the mass-property parameters of the spacecraft. In the mission of on-orbit servicing, as fuel is expended, or the payloads are add... The attitude control system design and its control effect are affected considerably by the mass-property parameters of the spacecraft. In the mission of on-orbit servicing, as fuel is expended, or the payloads are added or removed, the center of mass will be changed in certain axe; consequently, some thrusters' directions are deviated from the center of mass(CM) in certain plane. The CM of assembled spacecraft estimation and thruster direction control are studied. Firstly, the attitude dynamics of the assembled spacecraft is established based on the Newton-Euler method. Secondly, the estimation can be identified by the least recursive squares algorithm. Then, a scheme to control the thrusters' directions is proposed. By using the gimbal installed at the end of the boom, the angle of the thruster is controlled by driving the gimbal; therefore, thrusters can be directed to the CM again. Finally, numerical simulations are used to verify this scheme. Results of the numerical simulations clearly show that this control scheme is rational and feasible. 展开更多
关键词 on-orbit servicing thruster's direction control assembled spacecraft center of mass(CM) identification
下载PDF
Improved identification of glycerophospholipids using a linear ion trap mass spectrometer(LTQ) with Pulsed Q Collision Induced Dissociation(PQD)
3
作者 Tanxi Cai, Jing Li, Peng Xue, Zhengsheng Xie, Ziyou Cui, Junjie Hou, Xiulan Chen, Peng Wu, Pingsheng Liu, Fuquan Yang Proteomic Platform & National Laboratory of Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China, 100101 《生物物理学报》 CAS CSCD 北大核心 2009年第S1期191-191,共1页
Phospholipids are the major building blocks of the biological membranes. Additionally, phospholipids modulate membrane trafficking and metabolites derived from their
关键词 PQD with Pulsed Q Collision Induced Dissociation Improved identification of glycerophospholipids using a linear ion trap mass spectrometer
原文传递
Amino acid identification and sequence analysis of peptides by reaction mass spectrometry
4
作者 YANG Hou-Jun HU Xiao-Yu CHEN Yao-Zu 《Chinese Journal of Chemistry》 SCIE CAS CSCD 1993年第6期540-549,共8页
Fast atom bombardment mass spectrometry (FAB-MS) is applied to distinguish N- terminal series ions from C-terminal series ions of a peptide by on-probe acetylation, it provides valuable information about the sequence ... Fast atom bombardment mass spectrometry (FAB-MS) is applied to distinguish N- terminal series ions from C-terminal series ions of a peptide by on-probe acetylation, it provides valuable information about the sequence of an unknown peptide. The FAB mass spectra contain a number of characteristic ions at low-mass region in addition to the sequence ions at high-mass region. It was found that the ions below m/z 200 are characteristic of the amino acid composition of the peptide, from which the amino acid composition of the peptide could be estimated. Additionally, mixture analysis is also discussed. 展开更多
关键词 Pro Amino acid identification and sequence analysis of peptides by reaction mass spectrometry acid
全文增补中
上一页 1 下一页 到第
使用帮助 返回顶部