期刊文献+
共找到1,747篇文章
< 1 2 88 >
每页显示 20 50 100
An electrochemiluminescent magneto-immunosensor for ultrasensitive detection of hs-cTnI on a microfluidic chip
1
作者 Yun Hui Zhen Zhao +7 位作者 Weiliang Shu Fengshan Shen Weijun Kong Shengyong Geng Zhen Xu Tianzhun Wu Wenhua Zhou Xuefeng Yu 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第3期13-23,共11页
Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-c... Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-cTnI) is strongly recommended in clinical guidelines for early diagnosis of acute myocardial infarction.Based on the use of an electrode modified by single-walled carbon nanotubes (SWCNTs) and a Ru(bpy)32+-doped silica nanoparticle (Ru@SiO2)/tripropylamine (TPA) system,a novel type of electrochemiluminescent (ECL) magnetoimmunosensor is developed for ultrasensitive detection of hs-cTnI.In this approach,a large amount of[Ru(bpy)3]2+is loaded in SiO2(silica nanoparticles) as luminophores with high luminescent efficiency and SWCNTs as electrode surface modification material with excellent electrooxidation ability for TPA.Subsequently,a hierarchical micropillar array of microstructures is fabricated with a magnet placed at each end to efficiently confine a single layer of immunomagnetic microbeads on the surface of the electrode and enable 7.5-fold signal enhancement In particular,the use of transparent SWCNTs to modify a transparent ITO electrode provides a two-order-of-magnitude ECL signal amplification.A good linear calibration curve is developed for hs-cTnI concentrations over a wide range from 10 fg/ml to 10 ng/ml,with the limit of detection calculated as 8.720 fg/ml (S/N=3).This ultrasensitive immunosensor exhibits superior detection performance with remarkable stability,reproducibility,and selectivity.Satisfactory recoveries are obtained in the detection of hs-cTnI in human serum,providing a potentia analysis protocol for clinical applications. 展开更多
关键词 Electrochemiluminescent magneto-immunosensor microfluidic chip High-sensitivity cardiac troponin I Single-walled carbon nanotube [Ru(bpy)3]2+-doped silica nanoparticle
下载PDF
Advances in microfluidic-based DNA methylation analysis 被引量:1
2
作者 Jiwen Li Tiechuan Li Xuexin Duan 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第1期116-134,共19页
DNA methylation has been extensively investigated in recent years,not least because of its known relationship with various diseases.Progress in analytical methods can greatly increase the relevance of DNA methylation ... DNA methylation has been extensively investigated in recent years,not least because of its known relationship with various diseases.Progress in analytical methods can greatly increase the relevance of DNA methylation studies to both clinical medicine and scientific research.Microflu-idic chips are excellent carriers for molecular analysis,and their use can provide improvements from multiple aspects.On-chip molecular analysis has received extensive attention owing to its advantages of portability,high throughput,low cost,and high efficiency.In recent years,the use of novel microfluidic chips for DNA methylation analysis has been widely reported and has shown obvious superiority to conventional methods.In this review,wefirst focus on DNA methylation and its applications.Then,we discuss advanced microfluidic-based methods for DNA methylation analysis and describe the great progress that has been made in recent years.Finally,we summarize the advantages that microfluidic technology brings to DNA methylation analysis and describe several challenges and perspectives for on-chip DNA methylation analysis.This review should help researchers improve their understanding and make progress in developing microfluidic-based methods for DNA methylation analysis. 展开更多
关键词 microfluidic chip DNA methylation analysis Molecular analysis High throughput Low cost
下载PDF
Micro-LED芯片激光去除机理及工艺参数优化 被引量:1
3
作者 乔健 吴振铎 +2 位作者 彭信翰 冉雨宣 杨景卫 《光学精密工程》 EI CAS CSCD 北大核心 2024年第9期1360-1370,共11页
为提高面板级Micro-LED显示面板的制造质量,需要对不良Micro-LED芯片进行原位去除与修复,利用COMSOL建立激光双温烧蚀模型,开展了Micro-LED不良芯片激光去除机理和工艺参数的优化。通过单脉冲激光对MicroLED芯片烧蚀所形成表面光斑的直... 为提高面板级Micro-LED显示面板的制造质量,需要对不良Micro-LED芯片进行原位去除与修复,利用COMSOL建立激光双温烧蚀模型,开展了Micro-LED不良芯片激光去除机理和工艺参数的优化。通过单脉冲激光对MicroLED芯片烧蚀所形成表面光斑的直径平方来推算Micro-LED的烧蚀阈值,拟合出激光参数与烧蚀深度的关系,并对双温烧蚀模型的准确性进行验证;分析了激光光斑重叠率、能量密度和不同扫描路径下对应芯片的烧蚀特征及去除机理,结合双温烧蚀模型完成了激光扫描路径及对应工艺参数的优化。结果表明,飞秒激光烧蚀模型对Micro-LED芯片激光烧蚀加工的最大分析误差为9.28%,优化的激光去除模式实现了1秒/颗的快速精准剥离和焊盘表面的高质量整平修复,对大幅面Micro-LED显示面板规模化生产中不良芯片的快速修复具有重要的指导作用。 展开更多
关键词 飞秒激光 原位去除 微发光二极管显示器 不良芯片
下载PDF
Micro-mixing in chemical reactors:A perspective 被引量:3
4
作者 Zaisha Mao Chao Yang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第4期381-390,共10页
Micro-mixing is an important mechanism, which works simultaneously with macro-mixing in chemical reactors in process industries, for achieving the best selectivity with respect to desired products. In about a half cen... Micro-mixing is an important mechanism, which works simultaneously with macro-mixing in chemical reactors in process industries, for achieving the best selectivity with respect to desired products. In about a half century, a huge amount of data and knowledge has been accumulated from theoretical and experimental studies on micromixing. Nevertheless, those results are mostly composites of simplified theoretical and empirical models, and the true nature of interactions of flow inhomogeneity and micro-mixing with chemical reaction has not been fully unveiled. This article reviews the progress in micro-mixing study in chemical reactors to date. A few important topics related to the nature, experimental evaluation, and numerical simulation of micro-mixing are addressed.Some suggestions are given hopefully to motivate more chemical engineers to devote their efforts to better understanding of micro-mixing in chemical reactors. 展开更多
关键词 mixing simplified desired selectivity devote turbulence addressed accumulated reactant dispersed
下载PDF
NEW SELF-MIXING MICRO-INTERFEROMETER BASED ON EXTERNAL PHASE MODULATION 被引量:1
5
作者 GUO Dongmei WANG Ming 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第3期83-85,共3页
ASeblsf-tmraicxti:n gA innteewrf esreelnf-cme ioxcincgu rms iicnr oa -liansteerrf derioodmee t(eLrD b)a sbeyd r eofnl eecxtitnergn tahl ep lhiagshet fmroomdu ala tmioinrr oisr-plirkees etanrtgedet. in front of the ... ASeblsf-tmraicxti:n gA innteewrf esreelnf-cme ioxcincgu rms iicnr oa -liansteerrf derioodmee t(eLrD b)a sbeyd r eofnl eecxtitnergn tahl ep lhiagshet fmroomdu ala tmioinrr oisr-plirkees etanrtgedet. in front of the laser. Sinusoidal phase modulation of the beam is obtained by an electro-optic crystal (EOC) in the external cavity. The phase of the interference signal is demodulated by Fourier analysis method. The combination of the modulation and demodulation decreases the sensitivity of the instru-ment to fluctuations of the laser power and the noise induced by environment. Experimentally, the new micro-interferometer is applied to measure the micro-displacement of a high precision commer-cial PZT with an accuracy of 〈10 nm. 展开更多
关键词 micro-interferometer Self-mixing interference Displacement measurement
下载PDF
Analysis of micro vortex metallization and introduction of evaluation factor in mixing process
6
作者 赫俊国 魏希柱 +1 位作者 姜涛 张杰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第2期185-188,共4页
To improve the mixing efficiency in water purification or wastewater treatment process and understand the mechanism of mass transfer,and a suitable evaluation factor is introduced to evaluate the efficiency of mixing ... To improve the mixing efficiency in water purification or wastewater treatment process and understand the mechanism of mass transfer,and a suitable evaluation factor is introduced to evaluate the efficiency of mixing process.The diffusion mass transfer under turbulent condition is investigated based on dynamic and mathematical analysis.The results indicate that submicroscopic diffusion is the rate-limiting step in mass transfer,and the inertia effect of micro vortex causes the phase mixing.An excellent efficiency can be obtained by controlling the scale of micro vortex within millimeter.Furthermore,a new indicator named mixing factor(IH)is proposed to evaluate the efficiency of mixing processes,which is more feasible than conventional evaluation methods,because of its connection of mixing extent with energy consumption. 展开更多
关键词 mixing process micro vortex mixing efficiency mass transfer evaluating indicator
下载PDF
Effect of Viscosities on Mixing in A Patterned Micro Mixer
7
作者 华硕 刘扬 许友生 《Communications in Theoretical Physics》 SCIE CAS CSCD 2010年第5期952-956,共5页
The effect of viscosity and viscosity difference and boundary patterned slip on mixing in a micro mixer has been numerically studied using lattice Boltzmann method (LBM). The slip and no-slip ratio is not constant a... The effect of viscosity and viscosity difference and boundary patterned slip on mixing in a micro mixer has been numerically studied using lattice Boltzmann method (LBM). The slip and no-slip ratio is not constant and varies irregularly, and viscosity is altered by changing the relaxation time in LBE equation. The slip boundary condition is simulated by specular reflection boundary and the no-slip boundary condition is simulated by bounce back boundary. It has been found that it is feasible to optimize the micro mixer design by combining the viscosity effect and boundary patterned ratio altogether. 展开更多
关键词 micro mixing lattice Boltzmann method patterned boundary
下载PDF
Effect of Hole Size on Flow Structure and Mixing Characteristic in a Multi-Hole Baffled Micro Combustor
8
作者 Won Hyun Kim Young Su Park +1 位作者 Seon Myeong Park Tae Seon Park 《Journal of Applied Mathematics and Physics》 2017年第1期7-16,共10页
Flow structure and mixing properties by the baffle shape are numerically studied for a baffled micro combustor. The baffle shape is changed by various fuel and hole sizes. The numerical simulations based on different ... Flow structure and mixing properties by the baffle shape are numerically studied for a baffled micro combustor. The baffle shape is changed by various fuel and hole sizes. The numerical simulations based on different geometric conditions are performed by using the Reynolds Stress Model. The fuel-air mixing is greatly affected by flow recirculations. The centrally located flow recirculation has an important role for the entire mixing performance. The results show that this feature depends on the baffle configurations, and the baffle with small air holes represents efficient characters. 展开更多
关键词 micro COMBUSTOR BAFFLE Diameter Ratio Flow Recirculation mixing Secondary FLOWS
下载PDF
A Microfluidic System with Active Mixing for Improved Real-Time Isothermal Amplification
9
作者 Dianlong Yang Xiaodan Jiang +4 位作者 Yijie Zhou Xiaobin Dong Luyao Liu Lulu Zhang Xianbo Qiu 《Journal of Beijing Institute of Technology》 EI CAS 2022年第3期275-284,共10页
To improve the performance of real-time recombinase polymerase amplification(RPA),a microfluidic system with active mixing is developed to optimize the reaction dynamics.Instead of adopting a single typical reaction c... To improve the performance of real-time recombinase polymerase amplification(RPA),a microfluidic system with active mixing is developed to optimize the reaction dynamics.Instead of adopting a single typical reaction chamber,a specific reactor including a relatively large chamber in center with two adjacent zig-zag channels at two sides is integrated into the microfluidic chip.Active mixing is achieved by driving the viscous reagent between the chamber and the channel back and forth periodically with an outside compact peristaltic pump.To avoid reagent evapora-tion,one end of the reactor is sealed with paraffin oil.A hand-held companion device is developed to facilitate real-time RPA amplification within 20 min.The whole area of the reactor is heated with a resistance heater to provide uniform reaction temperature.To achieve real-time monitoring,a compact fluorescence detection module is integrated into the hand-held device.A smartphone with custom application software is adopted to control the hand-held device and display the real-time fluorescence curves.The performances of two cases with and without active on-chip mixing are compared between each other by detecting African swine fever viruses.It has been demonstrated that,with active on-chip mixing,the amplification efficiency and detection sensitivity can be signifi-cantly improved. 展开更多
关键词 recombinase polymerase amplification(RPA) microfluidic chip active mixing optical detection SMARTPHONE
下载PDF
Micro-crack detection of nonlinear Lamb wave propagation in three-dimensional plates with mixed-frequency excitation 被引量:3
10
作者 Wei-Guang Zhu Yi-Feng Li +3 位作者 Li-Qiang Guan Xi-Li Wan Hui-Yang Yu Xiao-Zhou Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第1期336-345,共10页
We propose a nonlinear ultrasonic technique by using the mixed-frequency signals excited Lamb waves to conduct micro-crack detection in thin plate structures.Simulation models of three-dimensional(3D)aluminum plates a... We propose a nonlinear ultrasonic technique by using the mixed-frequency signals excited Lamb waves to conduct micro-crack detection in thin plate structures.Simulation models of three-dimensional(3D)aluminum plates and composite laminates are established by ABAQUS software,where the aluminum plate contains buried crack and composite laminates comprises cohesive element whose thickness is zero to simulate delamination damage.The interactions between the S0 mode Lamb wave and the buried micro-cracks of various dimensions are simulated by using the finite element method.Fourier frequency spectrum analysis is applied to the received time domain signal and fundamental frequency amplitudes,and sum and difference frequencies are extracted and simulated.Simulation results indicate that nonlinear Lamb waves have different sensitivities to various crack sizes.There is a positive correlation among crack length,height,and sum and difference frequency amplitudes for an aluminum plate,with both amplitudes decreasing as crack thickness increased,i.e.,nonlinear effect weakens as the micro-crack becomes thicker.The amplitudes of sum and difference frequency are positively correlated with the length and width of the zero-thickness cohesive element in the composite laminates.Furthermore,amplitude ratio change is investigated and it can be used as an effective tool to detect inner defects in thin 3D plates. 展开更多
关键词 nonlinear Lamb wave mixed-frequency micro-CRACKS amplitude ratio
原文传递
Highly Sensitive Chemiluminescence Detection for PDMS/GIass Micro-chip Electrophoresis 被引量:1
11
作者 XiangYiHUANG JiaoNingWANG LinCHEN JiCurtREN 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第6期683-686,共4页
This paper described a highly sensitive chemiluminescence detection system for micro-chip electrophoresis (MCE) based on luminol-hydrogen peroxide reaction catalyzed by the metal ions. The micro-chip was composed of p... This paper described a highly sensitive chemiluminescence detection system for micro-chip electrophoresis (MCE) based on luminol-hydrogen peroxide reaction catalyzed by the metal ions. The micro-chip was composed of poly(dimethylsiloxane) (PDMS) and glass, and was fabricated by micro-machining technology. The surface of channels was dynamically modified by polydimethylacrylamide (PDMA) in order to eliminate unhomogeneous electroosmotic flow (EOF) of the PDMS/glass chip, adsorption of molecules, and improve hydrophobicity on PDMS surface. The detection modes, reagent mix procedures and reaction conditions were optimized and the detection limit of 5×10 mol/L for cobalt (II) was achieved by MCE with chemiluminescence detection, which was about four orders of magnitude more sensitive than that reported in the reference. 展开更多
关键词 micro-chip ELECTROPHORESIS chemiluminenscence poly(dimethylsiloxane).
下载PDF
Stable ^(85)Rb micro vapour cells:fabrication based on anodic bonding and application in chip-scale atomic clocks 被引量:3
12
作者 苏娟 邓科 +4 位作者 郭等柱 汪中 陈兢 张耿民 陈徐宗 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第11期243-250,共8页
We describe the microfabrication of ^85Rb vapour cells using a glass-silicon anodic bonding technique and in situ chemical reaction between rubidium chloride and barium azide to produce Rb. Under controlled conditions... We describe the microfabrication of ^85Rb vapour cells using a glass-silicon anodic bonding technique and in situ chemical reaction between rubidium chloride and barium azide to produce Rb. Under controlled conditions, the pure metallic Rb drops and buffer gases were obtained in the cells with a few mm^3 internal volumes during the cell sealing process. At an ambient temperature of 90 ℃ the optical absorption resonance of ^85Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 kHz, have been detected. The sealing quality and the stability of the cells have also been demonstrated experimentally by using the helium leaking detection and the after-9-month optoelectronics measurement which shows a similar CPT signal as its original status. In addition, the physics package of chip-scale atomic clock (CSAC) based on the cell was realized. The measured frequency stability of the physics package can reach to 2.1 × 10^-10 at one second when the cell was heated to 100 ℃ which proved that the cell has the quality to be used in portable and battery-operated devices. 展开更多
关键词 ^85Rb micro vapour cell anodic bonding coherent population trapping chip-scale atomic clock frequency stability
原文传递
Velocity distribution of flow with submerged flexible vegetations based on mixing-length approach 被引量:2
13
作者 槐文信 韩杰 +3 位作者 曾玉红 安翔 钱忠东 Yu-lu LIU 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2009年第3期343-351,共9页
By choosing a PVC slice to simulate flexible vegetation, we carried out experiments in an open channel with submerged flexible vegetation. A 3D acoustic Doppler velocimeter (micro ADV) was used to measure local flow... By choosing a PVC slice to simulate flexible vegetation, we carried out experiments in an open channel with submerged flexible vegetation. A 3D acoustic Doppler velocimeter (micro ADV) was used to measure local flow velocities and Reynolds stress. The results show that hydraulic characteristics in non-vegetation and vegetation layers are totally different. In a region above the vegetation, Reynolds stress distribution is linear, and the measured velocity profile is a classical logarithmic one. Based on the concept of new-riverbed, the river compression parameter representing the impact of vegetation on river is given, and a new assumption of mixing length expression is made. The formula for time-averaged velocity derived from the expression requires less parameters and simple calculation, and is useful in applications. 展开更多
关键词 flexible vegetation PVC slice micro ADV mixing-length approach streamwise velocity distribution Reynolds stress river compression parameter
下载PDF
Integrated Micro Bio Systems and High Performance Liquid Chromatographic System on Chip
14
作者 KITAMORI Takehiko 《色谱》 CAS CSCD 北大核心 2004年第4期335-337,共3页
关键词 高效液相色谱 小型集成化学系统 生物测定 相分离 毛细管电动色谱 碎片
下载PDF
Combination of Micro-fluidic Chip with Fluorescence Correlation Spectroscopy for Single Molecule Detection
15
作者 Rui BI Pu Dun ZHANG Chao Qing DONG Ji Cun REN 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第4期521-524,共4页
A single molecule detection technique was developed by the combination of a single channel poly (dimethylsiloxane)/glass micro-fluidic chip and fluorescence correlation spectroscopy (FCS). This method was successf... A single molecule detection technique was developed by the combination of a single channel poly (dimethylsiloxane)/glass micro-fluidic chip and fluorescence correlation spectroscopy (FCS). This method was successfully used to determine the proportion of two model components in the mixture containing fluorescein and the rhodamine-green succinimidyl ester. 展开更多
关键词 Fluorescence correlation spectroscopy micro-fluidic chip single molecule detection
下载PDF
Generating micro/nanostructures on magnesium alloy surface using ultraprecision diamond surface texturing process
16
作者 Hanheng Du Mengnan Jiang +2 位作者 Zuankai Wang Zhiwei Zhu Suet To 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第4期1472-1483,共12页
The lightness and high strength-to-weight ratio of the magnesium alloy have attracted more interest in various applications.However,micro/nanostructure generation on their surfaces remains a challenge due to the flamm... The lightness and high strength-to-weight ratio of the magnesium alloy have attracted more interest in various applications.However,micro/nanostructure generation on their surfaces remains a challenge due to the flammability and ignition.Motivated by this,this study proposed a machining process,named the ultraprecision diamond surface texturing process,to machine the micro/nanostructures on magnesium alloy surfaces.Experimental results showed the various microstructures and sawtooth-shaped nanostructures were successfully generated on the AZ31B magnesium alloy surfaces,demonstrating the effectiveness of this proposed machining process.Furthermore,sawtooth-shaped nanostructures had the function of inducing the optical effect and generating different colors on workpiece surfaces.The colorful letter and colorful flower image were clearly viewed on magnesium alloy surfaces.The corresponding cutting force,chip morphology,and tool wear were systematically investigated to understand the machining mechanism of micro/nanostructures on magnesium alloy surfaces.The proposed machining process can further improve the performances of the magnesium alloy and extend its functions to other fields,such as optics. 展开更多
关键词 Magnesium alloy micro/NANOSTRUCTURE Ultraprecision diamond surface texturing Cutting force chip morphology Structural color
下载PDF
基于200 mm硅基GaN的单色Micro LED微显示芯片制备及量产难点分析
17
作者 彭劲松 杨建兵 +3 位作者 殷照 汪曾峰 宋琦 吴焱 《光电子技术》 CAS 2023年第2期129-132,共4页
应用200 mm硅基GaN外延片,研究晶圆级键合、薄膜转移和微小尺寸像素制备等技术,实现了Micro LED微显示阵列的点亮与显示功能。相对于传统蓝宝石基GaN外延晶圆,200 mm硅基GaN外延晶圆与硅基驱动晶圆尺寸更匹配,有利于通过晶圆键合工艺实... 应用200 mm硅基GaN外延片,研究晶圆级键合、薄膜转移和微小尺寸像素制备等技术,实现了Micro LED微显示阵列的点亮与显示功能。相对于传统蓝宝石基GaN外延晶圆,200 mm硅基GaN外延晶圆与硅基驱动晶圆尺寸更匹配,有利于通过晶圆键合工艺实现低成本量产。同时对工艺量产的难点和解决思路进行了分析,指出显示缺陷是目前亟待解决的问题。 展开更多
关键词 发光二极管微显示芯片 硅基氮化镓外延片 显示缺陷
原文传递
Relationship between Leaf Micro- and Macro-Nutrients in Top Canopy Trees in a Mixed Forest in the Upper Rio Negro in the Amazon Region
18
作者 M. A. Sobrado 《American Journal of Plant Sciences》 2014年第10期1423-1431,共9页
The mixed forests of the upper Rio Negro at the northern of the Amazon basin grow in oxisol soils that are extremely infertile. These areas exhibit deficiencies in several macro-nutrients, and may also be characterize... The mixed forests of the upper Rio Negro at the northern of the Amazon basin grow in oxisol soils that are extremely infertile. These areas exhibit deficiencies in several macro-nutrients, and may also be characterized by the shortage or toxic excess of some micronutrients. The overall goal of this research is to collect more comprehensive information regarding the micronutrient composition of the upper Rio Negro forests as well as discern the relationship between leaf micro- and macro-nutrients that may contribute to the homeostasis and balance of the ionome. Firstly, the nutrient composition within the oxisol soil and leaf tissues of two top canopy tree species from the mixed forests was determined. We then analyzed the relationship between leaf micronutrient composition with N and P levels of the two species and that of species inhabiting the Amazon caatinga. Extractable soil Zn, B, Mn and Cu were very low in the mixed forest. In contrast, Fe and Al levels were potentially toxic. The analysis of leaf N/P ratios revealed for the first time the co-limitation of N and P in the mixed forest. This contrasts with species from the adjacent Amazon caatinga toposequence that are characterized by strong N limitation. All micronutrients within leaves of species inhabiting the mixed forest were also found to have low concentrations. Moreover, Fe and Al were detected at concentrations well below those reported for accumulator species. This suggested that leaf ion homeostasis was maintained under potentially toxic soil Fe and Al conditions. Leaf micronutrient (Fe, Zn and B) contents mirrored that of leaf N and P contents, and comparable Fe/N, Fe/P, Zn/N, Zn/P, B/N as well as B/P ratios were found across species and forest types. Therefore, forest species exhibited the capability to maintain leaf nutrient balances under soil conditions with deficient or toxic levels of micronutrients. 展开更多
关键词 AMAZON Forests AMAZON Caatinga LEAF Ionome Homeostasis LEAF N-P and microNUTRIENTS micro-Nutrient Deficiency microNUTRIENTS Toxicity mixed Forest N-P Co-Limitation Plant NUTRIENT Balance Oxisol PODZOL
下载PDF
人工智能时代成人高等教育教学发展路径探究 被引量:1
19
作者 张蕾 吉祥 陈涛 《继续教育研究》 2024年第5期103-107,共5页
成人高等教育教学是我国教育体系的一大分支,在培养卓越人才、建设终身学习型社会中发挥着重要作用。随着信息技术的发展,人工智能思维深刻影响着“教”与“学”方式,将人工智能与教育融合既是历史缘起与现实所需,也是政策支持与国家计... 成人高等教育教学是我国教育体系的一大分支,在培养卓越人才、建设终身学习型社会中发挥着重要作用。随着信息技术的发展,人工智能思维深刻影响着“教”与“学”方式,将人工智能与教育融合既是历史缘起与现实所需,也是政策支持与国家计划,更是时代呼唤与机械革命。故此,成人高等教育教学应在人工智能的带动下努力实现教育内容长效化、教育评价全景化、师资培养现代化、教学模式个性化,以此促进传统教学方式的变革,满足不同学习需求,促进教育资源均衡配置,为成人高等教育教学发展注入引擎新动能。 展开更多
关键词 人工智能 成人高等教育教学 发展 “翻转微教育” “混合微培训” “泛在微教育”
下载PDF
贺信精神引领下微纳加工技术课课程思政教学改革与实践
20
作者 王晨曦 刘威 +3 位作者 张威 原小慧 闫寒 田艳红 《高教学刊》 2024年第30期61-64,共4页
微纳加工技术课程的教学内容与我国当前所面临的高端芯片制造“卡脖子”技术密切相连。2020年以来该课程将习近平总书记贺信精神融入课程思政教学设计,通过寓德于教、寓哲于教、寓念于教和寓新于教的“四位一体”方式,引导学生树立坚定... 微纳加工技术课程的教学内容与我国当前所面临的高端芯片制造“卡脖子”技术密切相连。2020年以来该课程将习近平总书记贺信精神融入课程思政教学设计,通过寓德于教、寓哲于教、寓念于教和寓新于教的“四位一体”方式,引导学生树立坚定理想信念,厚植爱国主义情怀,提升品德修养,激发远大志向。该文列举多个典型案例,经过教学改革基本实现知识传授、价值引领和情怀根植三方面的有机统一,期待该教学设计及经验分享为全国各高校电子封装专业的课程思政教学改革提供借鉴。 展开更多
关键词 贺信精神 课程思政 微纳加工 芯片制造 教学改革
下载PDF
上一页 1 2 88 下一页 到第
使用帮助 返回顶部