The density of Ni-AI alloys in both liquid state and solid-liquid coexistence state was measured with a modified pycnometric method. It was found that the density of Ni-AI alloys decreases with increasing temperature ...The density of Ni-AI alloys in both liquid state and solid-liquid coexistence state was measured with a modified pycnometric method. It was found that the density of Ni-AI alloys decreases with increasing temperature and Al concentration in the alloys. The molar volume of liquid Ni-AI binary alloys increases with the increase of temperature and Al concentration. The partial molar volume of Al in Ni-AI binary alloy was calculated approximately. The molar volume of liquid Ni-AI alloy determined in the present work shows a negative deviation from the ideal linear molar volume.展开更多
The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) wasmeasured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decrea...The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) wasmeasured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decreaseswith increasing temperature, but increases with the increase of molybdenum concentration in the alloys. The molarvolume of liquid Ni-Mo binary alloys increases with the increase of temperature and molybdenum concentration. Thepartial molar volume of molybdenum in Ni-Mo binary alloy has been approximately calculated as [13.18-2.65×10^(-3)T+(-47.94+3.10×10^(-2)T)×10^(-2)X_(Mo)]×10^(-6)m^3·mol^(-1). The molar volume of Ni-Mo alloy determined inthe present work shows a negative deviation from the ideal linear mixing molar volume.展开更多
The density of liquid Ni-Ta alloys was measured by using a modified sessile drop method. It is found that the density of the liquid Ni-Ta alloys decreases with the increasing temperature, but increases with the increa...The density of liquid Ni-Ta alloys was measured by using a modified sessile drop method. It is found that the density of the liquid Ni-Ta alloys decreases with the increasing temperature, but increases with the increase of tantalum concentration in the alloys. The molar volume of liquid Ni-Ta binary alloys increases with the increase of temperature and tantalum concentration.展开更多
The densities of liquid NiCoAlCr quaternary alloys with a fixed molar ratio of Ni to Co to Al (x(Ni):x(Co):x(Al)≈73:12.15) which is close to the average value of the commercial Ni-based superalloys TMS75, INCO713, CM...The densities of liquid NiCoAlCr quaternary alloys with a fixed molar ratio of Ni to Co to Al (x(Ni):x(Co):x(Al)≈73:12.15) which is close to the average value of the commercial Ni-based superalloys TMS75, INCO713, CM247LC and CMSX-4, and the mass fraction of chromium changes from 0 to 9% were measured by a modified sessile drop method. It is found that with increasing temperature and chromium concentration in the alloys, the densities of the liquid NiCoAlCr quaternary alloys decrease, whereas the molar volume of the liquid NiCoAlCr quaternary alloys increases. And the liquid densities of NiCoAlCr quaternary alloys calculated from the partial molar volumes of nickel, cobalt, aluminum and chromium in the corresponding Ni-bases binary alloys are in good agreement with the experimental ones, i.e. within the error tolerance range the densities of the liquid Ni-based multi-component alloys can be predicted from the partial volumes of elements in Ni-based binary alloys in liquid state. The molar volume of liquid NiCoAlCr binary alloy shows a negative deviation from the ideal linear mixing and the deviation changes small with the increase of chromium concentration at the same temperature.展开更多
Pure K2Ti4O9 whiskers were prepared by KDC(Kneading-Drying-Calcination) method with TiO2 and K2CO3 as raw materials. The influences of TiO2/K2CO3 molar ratio(RT/K), calcination temperature(TC) and cooling proces...Pure K2Ti4O9 whiskers were prepared by KDC(Kneading-Drying-Calcination) method with TiO2 and K2CO3 as raw materials. The influences of TiO2/K2CO3 molar ratio(RT/K), calcination temperature(TC) and cooling process on phase composition and morphology of the whiskers were investigated by TG-DSC(thermo gravimetric-differential scanning calorimeter), XRD(X-ray diffraction), and SEM(scanning electron microscope). Pure K2Ti4O9 potassium titanate whiskers with large length-diameter ratio(r)(over 250) can be obtained at RT/K = 2.9 and TC = 950 ℃.展开更多
文摘The density of Ni-AI alloys in both liquid state and solid-liquid coexistence state was measured with a modified pycnometric method. It was found that the density of Ni-AI alloys decreases with increasing temperature and Al concentration in the alloys. The molar volume of liquid Ni-AI binary alloys increases with the increase of temperature and Al concentration. The partial molar volume of Al in Ni-AI binary alloy was calculated approximately. The molar volume of liquid Ni-AI alloy determined in the present work shows a negative deviation from the ideal linear molar volume.
文摘The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) wasmeasured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decreaseswith increasing temperature, but increases with the increase of molybdenum concentration in the alloys. The molarvolume of liquid Ni-Mo binary alloys increases with the increase of temperature and molybdenum concentration. Thepartial molar volume of molybdenum in Ni-Mo binary alloy has been approximately calculated as [13.18-2.65×10^(-3)T+(-47.94+3.10×10^(-2)T)×10^(-2)X_(Mo)]×10^(-6)m^3·mol^(-1). The molar volume of Ni-Mo alloy determined inthe present work shows a negative deviation from the ideal linear mixing molar volume.
文摘The density of liquid Ni-Ta alloys was measured by using a modified sessile drop method. It is found that the density of the liquid Ni-Ta alloys decreases with the increasing temperature, but increases with the increase of tantalum concentration in the alloys. The molar volume of liquid Ni-Ta binary alloys increases with the increase of temperature and tantalum concentration.
基金Project(NCET-05-0764) supported by the Program for New Century Excellent Talent in Universityproject(2004527) supported by SRF for ROCS, SEM
文摘The densities of liquid NiCoAlCr quaternary alloys with a fixed molar ratio of Ni to Co to Al (x(Ni):x(Co):x(Al)≈73:12.15) which is close to the average value of the commercial Ni-based superalloys TMS75, INCO713, CM247LC and CMSX-4, and the mass fraction of chromium changes from 0 to 9% were measured by a modified sessile drop method. It is found that with increasing temperature and chromium concentration in the alloys, the densities of the liquid NiCoAlCr quaternary alloys decrease, whereas the molar volume of the liquid NiCoAlCr quaternary alloys increases. And the liquid densities of NiCoAlCr quaternary alloys calculated from the partial molar volumes of nickel, cobalt, aluminum and chromium in the corresponding Ni-bases binary alloys are in good agreement with the experimental ones, i.e. within the error tolerance range the densities of the liquid Ni-based multi-component alloys can be predicted from the partial volumes of elements in Ni-based binary alloys in liquid state. The molar volume of liquid NiCoAlCr binary alloy shows a negative deviation from the ideal linear mixing and the deviation changes small with the increase of chromium concentration at the same temperature.
基金Funded by the Natural Science Foundation Key Project of Hubei Province(No.2011CDA060)
文摘Pure K2Ti4O9 whiskers were prepared by KDC(Kneading-Drying-Calcination) method with TiO2 and K2CO3 as raw materials. The influences of TiO2/K2CO3 molar ratio(RT/K), calcination temperature(TC) and cooling process on phase composition and morphology of the whiskers were investigated by TG-DSC(thermo gravimetric-differential scanning calorimeter), XRD(X-ray diffraction), and SEM(scanning electron microscope). Pure K2Ti4O9 potassium titanate whiskers with large length-diameter ratio(r)(over 250) can be obtained at RT/K = 2.9 and TC = 950 ℃.
基金National Natural Science Foundation of China(12175254,U1832119)National Key R&D Program of China(2021YFE0104800)+2 种基金International Partnership Program of Chinese Academy of Sciences(121631KYSB20200039)International Cooperation Project of Shanghai Science and Technology Commission(20520750200)National Centre for Research and Development(WPC2/1/SCAPOL/2021)。