期刊文献+
共找到211,470篇文章
< 1 2 250 >
每页显示 20 50 100
Indoor Air Quality Real-Time Monitoring Results of Pathology Department
1
作者 Like Shi Yue Wang +4 位作者 Liang Xu Yan Liu Dongsheng Yao Xiuwu Li Yuan Jia 《Journal of Environmental Protection》 2015年第8期851-856,共6页
In this work, the objectives were to provide a scientific basis for environmental governance and to ensure staff health by real-time monitoring of indoor air quality of the pathology department. Using eagle eye enviro... In this work, the objectives were to provide a scientific basis for environmental governance and to ensure staff health by real-time monitoring of indoor air quality of the pathology department. Using eagle eye environment monitor to make a real-time dynamic monitoring of the air quality of the pathological technical room for 30 days, the paper records the monitoring data of PM 2.5, PM 10, formaldehyde, CO2, total volatile organic compounds (TVOC) every day at Beijing time 3 a.m, 10 am, 1 pm, 4 pm, and 10 pm, and makes a summarization and analysis. The average value of CO2 concentration of the 5 time points is (0.05 ± 0.01)%, and each time point concentration are different (P 0.05);the average TVOC concentration of the 5 time points is (0.08 + 0.31) mg/m3. They are all different between the concentration at each time point (P 2 and NO are not checked out. Through the real-time online monitoring of the pathology room, we find that the formaldehyde concentration of different time periods is far more than the safety value standard, and the concentration of formaldehyde, CO2, PM 2.5, PM 10 and total volatile organic compound (TVOC) is different at different time periods, and the concentrations at working time are higher than the non-working time. We must take effective measures to control the concentration of harmful gases in order to ensure the staff’s health. 展开更多
关键词 PATHOLOGY DEPARTMENT INDOOR POLLUTION Real-Time monitoring Influence FACTORS
下载PDF
Analysis of the displacements of pipeline overpasses based on geodetic monitoring results
2
作者 Roman Shults Andriy Annenkov +6 位作者 Gulnur Seitkazina Saule Soltabayeva Zhenis Kozhayev Andrii Khailak Kira Nikitenko Bohdan Sossa Nataliia Kulichenko 《Geodesy and Geodynamics》 CSCD 2022年第1期50-71,共22页
There are many approaches to address geospatial monitoring of pipeline overpasses,among which the most widespread methods are terrestrial laser scanning and total station measurements.However,there is a problem in com... There are many approaches to address geospatial monitoring of pipeline overpasses,among which the most widespread methods are terrestrial laser scanning and total station measurements.However,there is a problem in comparing the geospatial monitoring data collected by different methods in different epochs.The main task of this work is to find the correspondence between points in different epochs.The total station measurements are carried out in specific discrete points of the pipeline overpass.In contrast,terrestrial laser scanning allows the collection of the whole data set without fixing specific point co-ordinates.In order to compare different data in different epochs,it is necessary to select a relevant presentation of the monitoring results(reference model)and specify appropriate criteria for quality inspection.In general,a pipeline can be presented as a spatial curve.In this study,two types of reference models are considered:cubic splines and Bezier curves.These models are examined for the monitoring of two gas pipeline overpasses.The first measurement epoch is accomplished by the terrestrial laser scanning,and the second measurement epoch is completed by the total station.The reference models are simulated by Matlab coding.The preliminary accuracy of ground laser scanning and total station mea-surement is selected as the criterion of quality inspection.The simulation and comparison results provide the evidence that the correct selection of reference model is a crucial component of successful geospatial monitoring.The results show that the Hermite splines are effective in the comparison of different data sets.These splines present the interpolation accuracy compatible with measurement accuracy,i.e.,15-20 mm for spatial displacement determination. 展开更多
关键词 Geospatial monitoring Terrestrial laser scanning Total station PIPELINE
原文传递
Radiological monitoring results of the ambient environment around Qinshan Nuclear Power Plant
3
作者 ZHANGRong-Suo ZENGGuang-Jian JIANGRang-Rong YEJi-Da XIANGYuan-Yi HUANGRen-Jie CAOZhong-Gang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2004年第1期59-64,共6页
A plan of surveillance monitoring Qinshan Nuclear Power Plant (QNPP) has been implemented since 1992, the objective of which is to establish the database of environmental radiation information around QNPP, and to dete... A plan of surveillance monitoring Qinshan Nuclear Power Plant (QNPP) has been implemented since 1992, the objective of which is to establish the database of environmental radiation information around QNPP, and to detect any unplanned discharge of radioactive materials from QNPP. This paper presents the monitoring results for radionuclide concentrations in the environmental matrices before and after QNPP operation. The radionuclide con- centrations in vegetation, food, atmosphere, soil and littoral soil samples have been determined. After operation of QNPP, the mean values of 137Cs, Sr and H in water are 0.6, 4.9 mBq/L and 1.7 Bq/L, respectively; the mean values 90 3 of137Cs in soil and littoral soil are 3.5 and 2.7 Bq/kg, respectively; the mean values of137Cs in rice, green cabbage, meat, mullet, milk and tea are 0.033, 0.039, 0.081, 0.069, 0.018 and 0.62 Bq/kg, respectively; the mean values of 90 Sr in rice, green cabbage and tea are 0.081, 0.315 and 4.1 Bq/kg, respectively; gross β activity in fallout is 0.9 Bq·m-2·d-1. Compared with the data before QNPP’s operation, no significant difference has heen observed in the radioactivity of137Cs, Sr, H and the gross β activity in ambient environmental matrices from 1992 to 2001, and 90 3 there are only some fluctuations within the range of background. 展开更多
关键词 辐射监测 秦山核电站 QNPP 环境污染 辐射防护
下载PDF
Results and Application of Soil and Water Conservation Monitoring in the Yellow River Basin
4
作者 Yaxi Cai Xiaodong Yang Binhua Zhao 《Journal of Architectural Research and Development》 2023年第3期40-45,共6页
Since water and soil conservation monitoring in the Yellow River Basin entered a new stage at the end of the 20th century,the monitoring scope has been expanding,the monitoring accuracy has been improving,the monitori... Since water and soil conservation monitoring in the Yellow River Basin entered a new stage at the end of the 20th century,the monitoring scope has been expanding,the monitoring accuracy has been improving,the monitoring content and indicators have been increasing,and the monitoring technology and methods have been improving.This paper mainly analyzes the status of soil and water conservation monitoring in the Yellow River Basin,as well as the construction of the monitoring system and related research,in order to provide a reference for watershed management and development and the scientific research of water and soil conservation. 展开更多
关键词 Soil and water conservation monitoring results APPLICATION
下载PDF
Vulvectomy: Indications and Results in the General Surgery Department of the Ignace Deen Chu Hospital in Conakry
5
作者 Camara Mariama Barry Mamadou Sakoba +1 位作者 Yattara Abdoulaye Touré Aboubacar 《Open Journal of Obstetrics and Gynecology》 2024年第4期560-564,共5页
Introduction: The aim of this study was to report the indications and evaluate the results of vulvectomy in the general surgery department of Ignace Deen Hospital, CHU Conakry. Materials and Methods: This was a retros... Introduction: The aim of this study was to report the indications and evaluate the results of vulvectomy in the general surgery department of Ignace Deen Hospital, CHU Conakry. Materials and Methods: This was a retrospective descriptive study, conducted over a period of five (05) years from January 1, 2018 to December 31, 2022, in the general surgery department of Ignace Deen Hospital, CHU Conakry. We included in our study all patient records in whom vulvectomy was performed. Results: We recorded 15 cases of vulvectomy out of 453 perineal surgeries, i.e. 3.31%, with a mean age of 43.56 years and extremes of 35 and 69 years. Vulvar cancer was the most common diagnosis (46.67%), followed by Buschke-Lowenstein (33.33%) and anal canal cancer extending to the vulva (20%). Six patients had undergone biopsy (40%). Vulvectomy with lymph node dissection was performed in only 9 patients (60%), and all surgical specimens were sent to anatomical pathology (100%). Conclusion: Vulvectomy is a surgical technique most often indicated for the treatment of vulvar cancer. 展开更多
关键词 VULVECTOMY INDICATIONS results Ignace Deen Conakry University Hospital
下载PDF
Application and management of continuous glucose monitoring in diabetic kidney disease
6
作者 Xin-Miao Zhang Quan-Quan Shen 《World Journal of Diabetes》 SCIE 2024年第4期591-597,共7页
Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly fou... Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly found in diabetic patients with DKD and especially ESKD,as a result of impaired renal metabolism.It is essential to monitor glycemia for effective management of DKD.Hemoglobin A1c(HbA1c)has long been considered as the gold standard for monitoring glycemia for>3 months.However,assessment of HbA1c has some bias as it is susceptible to factors such as anemia and liver or kidney dysfunction.Continuous glucose monitoring(CGM)has provided new insights on glycemic assessment and management.CGM directly measures glucose level in interstitial fluid,reports real-time or retrospective glucose concentration,and provides multiple glycemic metrics.It avoids the pitfalls of HbA1c in some contexts,and may serve as a precise alternative to estimation of mean glucose and glycemic variability.Emerging studies have demonstrated the merits of CGM for precise monitoring,which allows fine-tuning of glycemic management in diabetic patients.Therefore,CGM technology has the potential for better glycemic monitoring in DKD patients.More research is needed to explore its application and management in different stages of DKD,including hemodialysis,peritoneal dialysis and kidney transplantation. 展开更多
关键词 Diabetic kidney disease Continuous glucose monitoring Glycemic monitoring HEMODIALYSIS Peritoneal dialysis Kidney transplantation
下载PDF
Push forward LC-MS-based therapeutic drug monitoring and pharmacometabolomics for anti-tuberculosis precision dosing and comprehensive clinical management
7
作者 Nguyen Quang Thu Nguyen Tran Nam Tien +3 位作者 Nguyen Thi Hai Yen Thuc-Huy Duong Nguyen Phuoc Long Huy Truong Nguyen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第1期16-38,共23页
The spread of tuberculosis(TB),especially multidrug-resistant TB and extensively drug-resistant TB,has strongly motivated the research and development of new anti-TB drugs.New strategies to facilitate drug combination... The spread of tuberculosis(TB),especially multidrug-resistant TB and extensively drug-resistant TB,has strongly motivated the research and development of new anti-TB drugs.New strategies to facilitate drug combinations,including pharmacokinetics-guided dose optimization and toxicology studies of first-and second-line anti-TB drugs have also been introduced and recommended.Liquid chromatography-mass spectrometry(LC-MS)has arguably become the gold standard in the analysis of both endo-and exo-genous compounds.This technique has been applied successfully not only for therapeutic drug monitoring(TDM)but also for pharmacometabolomics analysis.TDM improves the effectiveness of treatment,reduces adverse drug reactions,and the likelihood of drug resistance development in TB patients by determining dosage regimens that produce concentrations within the therapeutic target window.Based on TDM,the dose would be optimized individually to achieve favorable outcomes.Pharmacometabolomics is essential in generating and validating hypotheses regarding the metabolism of anti-TB drugs,aiding in the discovery of potential biomarkers for TB diagnostics,treatment monitoring,and outcome evaluation.This article highlighted the current progresses in TDM of anti-TB drugs based on LC-MS bioassay in the last two decades.Besides,we discussed the advantages and disadvantages of this technique in practical use.The pressing need for non-invasive sampling approaches and stability studies of anti-TB drugs was highlighted.Lastly,we provided perspectives on the prospects of combining LC-MS-based TDM and pharmacometabolomics with other advanced strategies(pharmacometrics,drug and vaccine developments,machine learning/artificial intelligence,among others)to encapsulate in an all-inclusive approach to improve treatment outcomes of TB patients. 展开更多
关键词 TUBERCULOSIS Therapeutic drug monitoring LC-MS MIPD Pharmacometabolomics Precision medicine
下载PDF
Deformation monitoring of long-span railway bridges based on SBAS-InSAR technology
8
作者 Lv Zhou Xinyi Li +4 位作者 Yuanjin Pan Jun Ma Cheng Wang Anping Shi Yukai Chen 《Geodesy and Geodynamics》 EI CSCD 2024年第2期122-132,共11页
The deformation monitoring of long-span railway bridges is significant to ensure the safety of human life and property.The interferometric synthetic aperture radar(In SAR)technology has the advantage of high accuracy ... The deformation monitoring of long-span railway bridges is significant to ensure the safety of human life and property.The interferometric synthetic aperture radar(In SAR)technology has the advantage of high accuracy in bridge deformation monitoring.This study monitored the deformation of the Ganjiang Super Bridge based on the small baseline subsets(SBAS)In SAR technology and Sentinel-1A data.We analyzed the deformation results combined with bridge structure,temperature,and riverbed sediment scouring.The results are as follows:(1)The Ganjiang Super Bridge area is stable overall,with deformation rates ranging from-15.6 mm/yr to 10.7 mm/yr(2)The settlement of the Ganjiang Super Bridge deck gradually increases from the bridge tower toward the main span,which conforms to the typical deformation pattern of a cable-stayed bridge.(3)The sediment scouring from the riverbed cause the serious settlement on the bridge’s east side compared with that on the west side.(4)The bridge deformation negatively correlates with temperature,with a faster settlement at a higher temperature and a slow rebound trend at a lower temperature.The study findings can provide scientific data support for the health monitoring of long-span railway bridges. 展开更多
关键词 SBAS-InSAR Long-span railway bridge Deformation monitoring Bridge structure Time series deformation
原文传递
Advances in Wireless,Batteryless,Implantable Electronics for Real‑Time,Continuous Physiological Monitoring
9
作者 Hyeonseok Kim Bruno Rigo +2 位作者 Gabriella Wong Yoon Jae Lee Woon‑Hong Yeo 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期254-302,共49页
This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design co... This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design considerations,such as biological constraints,energy sourcing,and wireless communication,are discussed in achieving the desired performance of the devices and enhanced interface with human tissues.In addition,we review the recent achievements in materials used for developing implantable systems,emphasizing their importance in achieving multi-functionalities,biocompatibility,and hemocompatibility.The wireless,batteryless devices offer minimally invasive device insertion to the body,enabling portable health monitoring and advanced disease diagnosis.Lastly,we summarize the most recent practical applications of advanced implantable devices for human health care,highlighting their potential for immediate commercialization and clinical uses. 展开更多
关键词 Implantable electronics Biomedical systems Batteryless devices Wireless electronics Physiological signal monitoring
下载PDF
Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information
10
作者 Jin Zhou Shenghan Zhou +4 位作者 Peidi Fan Xunjia Li Yibin Ying Jianfeng Ping Yuxiang Pan 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期183-211,共29页
In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,... In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,implantable electrochemical microsensors have emerged as a prominent area of research.These microsensors not only fulfill the technical requirements for monitoring animal physiological information but also offer an ideal platform for integration.They have been extensively studied for their ability to monitor animal physiological information in a minimally invasive manner,characterized by their bloodless,painless features,and exceptional performance.The development of implantable electrochemical microsensors for in vivo monitoring of animal physiological information has witnessed significant scientific and technological advancements through dedicated efforts.This review commenced with a comprehensive discussion of the construction of microsensors,including the materials utilized and the methods employed for fabrication.Following this,we proceeded to explore the various implantation technologies employed for electrochemical microsensors.In addition,a comprehensive overview was provided of the various applications of implantable electrochemical microsensors,specifically in the monitoring of diseases and the investigation of disease mechanisms.Lastly,a concise conclusion was conducted on the recent advancements and significant obstacles pertaining to the practical implementation of implantable electrochemical microsensors. 展开更多
关键词 Electrochemical microsensors Implantable sensors In vivo monitoring Animal physiological information
下载PDF
Microarrow sensor array with enhanced skin adhesion for transdermal continuous monitoring of glucose and reactive oxygen species
11
作者 Xinshuo Huang Baoming Liang +9 位作者 Shantao Zheng Feifei Wu Mengyi He Shuang Huang Jingbo Yang Qiangqiang Ouyang Fanmao Liu Jing Liu Hui-jiuan Chen Xi Xie 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期14-30,共17页
Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain an... Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain and potential tissue inflammation,and the presence of reactive oxygen species(ROS)due to inflammationmay affect glucose detection.Microneedle technology is less invasive,yet microneedle adhesion with skin tissue is limited.In this work,we developed a microarrow sensor array(MASA),which provided enhanced skin surface adhesion and enabled simultaneous detection of glucose and H_(2)O_(2)(representative of ROS)in interstitial fluid in vivo.The microarrows fabricated via laser micromachining were modified with functional coating and integrated into a patch of a three-dimensional(3D)microneedle array.Due to the arrow tip mechanically interlocking with the tissue,the microarrow array could better adhere to the skin surface after penetration into skin.The MASA was demonstrated to provide continuous in vivo monitoring of glucose and H_(2)O_(2) concentrations,with the detection of H_(2)O_(2) providing a valuable reference for assessing the inflammation state.Finally,the MASA was integrated into a monitoring system using custom circuitry.This work provides a promising tool for the stable and reliable monitoring of blood glucose in diabetic patients. 展开更多
关键词 Microarrow sensor array Glucose sensing Reactive oxygen species sensing Integrated system Continuous monitoring
下载PDF
Panoptic UAV:Panoptic Segmentation of UAV Images for Marine Environment Monitoring
12
作者 Yuling Dou Fengqin Yao +7 位作者 Xiandong Wang Liang Qu Long Chen Zhiwei Xu Laihui Ding Leon Bevan Bullock Guoqiang Zhong Shengke Wang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期1001-1014,共14页
UAV marine monitoring plays an essential role in marine environmental protection because of its flexibility and convenience,low cost and convenient maintenance.In marine environmental monitoring,the similarity between... UAV marine monitoring plays an essential role in marine environmental protection because of its flexibility and convenience,low cost and convenient maintenance.In marine environmental monitoring,the similarity between objects such as oil spill and sea surface,Spartina alterniflora and algae is high,and the effect of the general segmentation algorithm is poor,which brings new challenges to the segmentation of UAV marine images.Panoramic segmentation can do object detection and semantic segmentation at the same time,which can well solve the polymorphism problem of objects in UAV ocean images.Currently,there are few studies on UAV marine image recognition with panoptic segmentation.In addition,there are no publicly available panoptic segmentation datasets for UAV images.In this work,we collect and annotate UAV images to form a panoptic segmentation UAV dataset named UAV-OUC-SEG and propose a panoptic segmentation method named PanopticUAV.First,to deal with the large intraclass variability in scale,deformable convolution and CBAM attention mechanism are employed in the backbone to obtain more accurate features.Second,due to the complexity and diversity of marine images,boundary masks by the Laplacian operator equation from the ground truth are merged into feature maps to improve boundary segmentation precision.Experiments demonstrate the advantages of PanopticUAV beyond the most other advanced approaches on the UAV-OUC-SEG dataset. 展开更多
关键词 Panoptic segmentation UAV marine monitoring attention mechanism boundary mask enhancement
下载PDF
Comparative Analysis of ARIMA and LSTM Model-Based Anomaly Detection for Unannotated Structural Health Monitoring Data in an Immersed Tunnel
13
作者 Qing Ai Hao Tian +4 位作者 Hui Wang Qing Lang Xingchun Huang Xinghong Jiang Qiang Jing 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1797-1827,共31页
Structural Health Monitoring(SHM)systems have become a crucial tool for the operational management of long tunnels.For immersed tunnels exposed to both traffic loads and the effects of the marine environment,efficient... Structural Health Monitoring(SHM)systems have become a crucial tool for the operational management of long tunnels.For immersed tunnels exposed to both traffic loads and the effects of the marine environment,efficiently identifying abnormal conditions from the extensive unannotated SHM data presents a significant challenge.This study proposed amodel-based approach for anomaly detection and conducted validation and comparative analysis of two distinct temporal predictive models using SHM data from a real immersed tunnel.Firstly,a dynamic predictive model-based anomaly detectionmethod is proposed,which utilizes a rolling time window for modeling to achieve dynamic prediction.Leveraging the assumption of temporal data similarity,an interval prediction value deviation was employed to determine the abnormality of the data.Subsequently,dynamic predictive models were constructed based on the Autoregressive Integrated Moving Average(ARIMA)and Long Short-Term Memory(LSTM)models.The hyperparameters of these models were optimized and selected using monitoring data from the immersed tunnel,yielding viable static and dynamic predictive models.Finally,the models were applied within the same segment of SHM data,to validate the effectiveness of the anomaly detection approach based on dynamic predictive modeling.A detailed comparative analysis discusses the discrepancies in temporal anomaly detection between the ARIMA-and LSTM-based models.The results demonstrated that the dynamic predictive modelbased anomaly detection approach was effective for dealing with unannotated SHM data.In a comparison between ARIMA and LSTM,it was found that ARIMA demonstrated higher modeling efficiency,rendering it suitable for short-term predictions.In contrast,the LSTM model exhibited greater capacity to capture long-term performance trends and enhanced early warning capabilities,thereby resulting in superior overall performance. 展开更多
关键词 Anomaly detection dynamic predictive model structural health monitoring immersed tunnel LSTM ARIMA
下载PDF
VR-based digital twin for remote monitoring of mining equipment:Architecture and a case study
14
作者 Jovana PLAVŠIĆ Ilija MIŠKOVIĆNorman BKeevil 《虚拟现实与智能硬件(中英文)》 EI 2024年第2期100-112,共13页
Background Traditional methods for monitoring mining equipment rely primarily on visual inspections,which are time-consuming,inefficient,and hazardous.This article introduces a novel approach to monitoring mission-cri... Background Traditional methods for monitoring mining equipment rely primarily on visual inspections,which are time-consuming,inefficient,and hazardous.This article introduces a novel approach to monitoring mission-critical systems and services in the mining industry by integrating virtual reality(VR)and digital twin(DT)technologies.VR-based DTs enable remote equipment monitoring,advanced analysis of machine health,enhanced visualization,and improved decision making.Methods This article presents an architecture for VR-based DT development,including the developmental stages,activities,and stakeholders involved.A case study on the condition monitoring of a conveyor belt using real-time synthetic vibration sensor data was conducted using the proposed methodology.The study demonstrated the application of the methodology in remote monitoring and identified the need for further development for implementation in active mining operations.The article also discusses interdisciplinarity,choice of tools,computational resources,time and cost,human involvement,user acceptance,frequency of inspection,multiuser environment,potential risks,and applications beyond the mining industry.Results The findings of this study provide a foundation for future research in the domain of VR-based DTs for remote equipment monitoring and a novel application area for VR in mining. 展开更多
关键词 Virtual reality Digital twin Condition monitoring Mining equipment
下载PDF
Appropriateness of Amikacin Dose Prescription, Monitoring and Safety during Hospitalization as an Impact of Clinical Pharmacologist Intervention, in the Israeli Regional Hospital
15
作者 Renata Shihmanter Olga Lazar Lidia Arcavi 《Journal of Biosciences and Medicines》 2024年第3期337-354,共18页
Background: Use of inappropriate amikacin dose is one of the most important factors in inducing toxicity, prolonged hospitalization as well as in increasing patient’s mortality. Objective: The aims of this study are ... Background: Use of inappropriate amikacin dose is one of the most important factors in inducing toxicity, prolonged hospitalization as well as in increasing patient’s mortality. Objective: The aims of this study are the analysis of amikacin dose, serum level and the examination of the effectiveness of the clinical pharmacologist (CP) therapeutic drug monitoring (TDM) intervention to guarantee the safety of amikacin use. Methods: This is a one-year retrospective observational chart review study, which evaluates amikacin dose, serum drug level, development of adverse effects in patients on amikacin with or without CP TDM consultation. Results: Amikacin was prescribed for 393 complex patients, with median age 83. Amikacin group (AG) included 140 (32%) courses with CP consultation (AG1) and 292 (68%) courses without CP consultation (AG2). The distribution of most study characteristics in both groups was similar including amikacin dose (9-10 mg/kg/day), renal failure (14%) and mortality (12%). Acceptance for CP consultation was in 46% of amikacin courses and dose changes were done in 63% after CP intervention. Prolonged antibiotic course (4.6 ± 1.5 vs 3.8 ± 1.6 days, p < 0.0001) and the patient’s hemodynamic instability (15% vs 7%, p = 0.01) were more frequent in the AG1 compared to the AG2. There was a strong association between CP consultation and prolonged hospitalization (p = 0.005), while no association between it and amikacin adverse effects, renal failure or mortality. Conclusions: There was no trend to reducing amikacin toxicity, days of hospitaliza tion or mortality in patients with CP consultation. CP TDM intervention was more in the management of complicated clinical situations. However, it is necessary to optimize it. 展开更多
关键词 AMIKACIN Therapeutic Drug monitoring APPROPRIATE Clinical Pharmacologist SAFETY Adverse Effects
下载PDF
Monitoring seismicity in the southern Sichuan Basin using a machine learning workflow
16
作者 Kang Wang Jie Zhang +2 位作者 Ji Zhang Zhangyu Wang Huiyu Zhu 《Earthquake Research Advances》 CSCD 2024年第1期59-66,共8页
Monitoring seismicity in real time provides significant benefits for timely earthquake warning and analyses.In this study,we propose an automatic workflow based on machine learning(ML)to monitor seismicity in the sout... Monitoring seismicity in real time provides significant benefits for timely earthquake warning and analyses.In this study,we propose an automatic workflow based on machine learning(ML)to monitor seismicity in the southern Sichuan Basin of China.This workflow includes coherent event detection,phase picking,and earthquake location using three-component data from a seismic network.By combining Phase Net,we develop an ML-based earthquake location model called Phase Loc,to conduct real-time monitoring of the local seismicity.The approach allows us to use synthetic samples covering the entire study area to train Phase Loc,addressing the problems of insufficient data samples,imbalanced data distribution,and unreliable labels when training with observed data.We apply the trained model to observed data recorded in the southern Sichuan Basin,China,between September 2018 and March 2019.The results show that the average differences in latitude,longitude,and depth are 5.7 km,6.1 km,and 2 km,respectively,compared to the reference catalog.Phase Loc combines all available phase information to make fast and reliable predictions,even if only a few phases are detected and picked.The proposed workflow may help real-time seismic monitoring in other regions as well. 展开更多
关键词 Earthquake monitoring Machine learning Local seismicity Gaussian waveform Sparse stations
下载PDF
Is tumor necrosis factor-α monoclonal therapy with proactive therapeutic drug monitoring optimized for inflammatory bowel disease? Network meta-analysis
17
作者 Fang-Yuan Zheng Kai-Si Yang +5 位作者 Wen-Cheng Min Xin-Zhu Li Yu Xing Shuai Wang Ying-Shi Zhang Qing-Chun Zhao 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期571-584,共14页
BACKGROUND The efficacy and safety of anti-tumor necrosis factor-α(TNF-α)monoclonal antibody therapy[adalimumab(ADA)and infliximab(IFX)]with therapeutic drug monitoring(TDM),which has been proposed for inflammatory ... BACKGROUND The efficacy and safety of anti-tumor necrosis factor-α(TNF-α)monoclonal antibody therapy[adalimumab(ADA)and infliximab(IFX)]with therapeutic drug monitoring(TDM),which has been proposed for inflammatory bowel disease(IBD)patients,are still controversial.AIM To determine the efficacy and safety of anti-TNF-αmonoclonal antibody therapy with proactive TDM in patients with IBD and to determine which subtype of IBD patients is most suitable for proactive TDM interventions.METHODS As of July 2023,we searched for randomized controlled trials(RCTs)and observa-tional studies in PubMed,Embase,and the Cochrane Library to compare anti-TNF-αmonoclonal antibody therapy with proactive TDM with therapy with reactive TDM or empiric therapy.Pairwise and network meta-analyses were used to determine the IBD patient subtype that achieved clinical remission and to determine the need for surgery.RESULTS This systematic review and meta-analysis yielded 13 studies after exclusion,and the baseline indicators were balanced.We found a significant increase in the number of patients who achieved clinical remission in the ADA[odds ratio(OR)=1.416,95%confidence interval(CI):1.196-1.676]and RCT(OR=1.393,95%CI:1.182-1.641)subgroups and a significant decrease in the number of patients who needed surgery in the proactive vs reactive(OR=0.237,95%CI:0.101-0.558)and IFX+ADA(OR=0.137,95%CI:0.032-0.588)subgroups,and the overall risk of adverse events was reduced(OR=0.579,95%CI:0.391-0.858)according to the pairwise meta-analysis.Moreover,the network meta-analysis results suggested that patients with IBD treated with ADA(OR=1.39,95%CI:1.19-1.63)were more likely to undergo TDM,especially in comparison with patients with reactive TDM(OR=1.38,95%CI:1.07-1.77).CONCLUSION Proactive TDM is more suitable for IBD patients treated with ADA and has obvious advantages over reactive TDM.We recommend proactive TDM in IBD patients who are treated with ADA. 展开更多
关键词 Inflammatory bowel disease Therapeutic drug monitoring ADALIMUMAB INFLIXIMAB Network meta-analysis
下载PDF
Continuous glucose monitoring metrics in pregnancy with type 1 diabetes mellitus
18
作者 Mohammad Sadiq Jeeyavudeen Mairi Crosby Joseph M Pappachan 《World Journal of Methodology》 2024年第1期6-17,共12页
Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level mon... Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level monitoring and periodic HbA1c tests,the advent of continuous glucose monitoring(CGM)systems has revolutionized the approach.These devices offer a safe and reliable means of tracking glucose levels in real-time,benefiting both women with diabetes during pregnancy and the healthcare providers.Moreover,CGM systems have shown a low rate of side effects and high feasibility when used in pregnancies complicated by diabetes,especially when paired with continuous subcutaneous insulin infusion pump as hybrid closed loop device.Such a combined approach has been demonstrated to improve overall blood sugar control,lessen the occurrence of preeclampsia and neonatal hypoglycaemia,and minimize the duration of neonatal intensive care unit stays.This paper aims to offer a comprehensive evaluation of CGM metrics specifically tailored for pregnancies impacted by type 1 diabetes mellitus. 展开更多
关键词 Type 1 diabetes mellitus Continuous glucose monitoring PREGNANCY Glycaemic control Continuous glucose monitoring system
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
19
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 Transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
Fiber optic monitoring of an anti-slide pile in a retrogressive landslide
20
作者 Lei Zhang Honghu Zhu +1 位作者 Heming Han Bin Shi 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第1期333-343,共11页
Anti-slide piles are one of the most important reinforcement structures against landslides,and evalu-ating the working conditions is of great significance for landslide mitigation.The widely adopted analytical methods... Anti-slide piles are one of the most important reinforcement structures against landslides,and evalu-ating the working conditions is of great significance for landslide mitigation.The widely adopted analytical methods of pile internal forces include cantilever beam method and elastic foundation beam method.However,due to many assumptions involved in calculation,the analytical models cannot be fully applicable to complex site situations,e.g.landslides with multi-sliding surfaces and pile-soil interface separation as discussed herein.In view of this,the combination of distributed fiber optic sensing(DFOS)and strain-internal force conversion methods was proposed to evaluate the working conditions of an anti-sliding pile in a typical retrogressive landslide in the Three Gorges reservoir area,China.Brillouin optical time domain reflectometry(BOTDR)was utilized to monitor the strain distri-bution along the pile.Next,by analyzing the relative deformation between the pile and its adjacent inclinometer,the pile-soil interface separation was profiled.Finally,the internal forces of the anti-slide pile were derived based on the strain-internal force conversion method.According to the ratio of calculated internal forces to the design values,the working conditions of the anti-slide pile could be evaluated.The results demonstrated that the proposed method could reveal the deformation pattern of the anti-slide pile system,and can quantitatively evaluate its working conditions. 展开更多
关键词 Anti-slide pile Multi-sliding surface Pile-soil interface Brillouin optical time domain reflectometry (BOTDR) Geotechnical monitoring Reservoir landslide
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部