期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Endophthalmitis in silicone oil-filled eye: A case report
1
作者 Hui-Chao Yan Ze-Lu Wang +5 位作者 Wen-Zhen Yu Ming-Wei Zhao Jian-Hong Liang Hong Yin Xuan Shi Heng Miao 《World Journal of Clinical Cases》 SCIE 2024年第1期163-168,共6页
BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis ... BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis include the removal of silicone oil,washout of the vitreous cavity,administration of intravitreal antibiotics,and reinjection of silicone oil.CASE SUMMARY Herein,we report the case of a 39-year-old man with unilateral endophthalmitis after pars plana vitrectomy and silicone oil tamponade.Intravitreal injections of full-dose antibiotics and anterior chamber washout were used to treat the patient.No signs of retinal toxicity were observed during the follow-up period.CONCLUSION Intravitreal full-dose antibiotic injections and anterior chamber washout are promising alternatives to traditional therapies for endophthalmitis in silicone oilfilled eyes. 展开更多
关键词 ENDOPHTHALMITIS Intravitreal injection Silicone oil-filled eye Pars plana vitrectomy WASHOUT Case report
下载PDF
Design and friction loss study of full-ocean depth oil-filled direct current motor
2
作者 Hao WANG Chen CAO +3 位作者 Jin GUO Wei WANG Peng ZHOU Jia-wang CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2022年第8期587-598,共12页
In this study,we designed an oil-filled motor that can be used at full-ocean depths,and investigated the friction losses caused by the rotating seal and the properties of the oil.The direct current(DC)motor is encapsu... In this study,we designed an oil-filled motor that can be used at full-ocean depths,and investigated the friction losses caused by the rotating seal and the properties of the oil.The direct current(DC)motor is encapsulated in an aluminum alloy housing.A rubber diaphragm is used to balance the internal and external pressures so that the motor can work on the seabed without pressure difference.To study the resistance caused by the rotating seal,a numerical model of the Glyd ring and the rotating shaft was established.Results from a rotational torque test agreed with those from numerical analysis.The kinematic viscosity of four oils was measured at 1-25℃.Oil bath experiments in an incubator showed that the resistance from oil is highly correlated with its dynamic viscosity.Dimethicone appears to be very suitable as an insulating oil for these motors.The working characteristics of the motor were tested in a high-pressure chamber.The results showed that the motor needs to overcome higher oil resistance under higher pressure.A prototype of a pressure-adaptive motor was designed and applied successfully in the hadal zone at a water depth of more than 10000 m. 展开更多
关键词 oil-filled motor Full-ocean depth Rotating seals Friction loss Viscous power Sea trial
原文传递
Non-contact wide-field viewing system-assisted scleral buckling surgery for retinal detachment in silicone oilfilled eyes
3
作者 Su-Lan Wu Yi-Qi Chen +7 位作者 Li-Jun Shen Jian-Bo Mao Li Lin Ji-Wei Tao Huan Chen Shi-An Zhang Jia-Feng Yu Chen-Xi Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期761-766,共6页
AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.MET... AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes. 展开更多
关键词 non-contact wide-field viewing system scleral buckling silicone oil-filled retinal detachment
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部