The fault current level analysis is important for bipolar direct current(DC)grids,which determines the operation and protection requirements.The DC grid topology significantly impacts the current path and then the fau...The fault current level analysis is important for bipolar direct current(DC)grids,which determines the operation and protection requirements.The DC grid topology significantly impacts the current path and then the fault current level of the grid,which makes it possible to limit the fault current by optimizing the grid topology.However,the corresponding discussion in the literature is indigent.Aiming at this point,the impact of grid topology,i.e.,the connecting scheme of converters,on the pole-to-ground fault current in bipolar DC grids,is investigated in this paper,and the ground-return-based and metallic-return-based grounding schemes are considered,respectively.Firstly,the decoupled equivalent model in frequency domain for fault current analysis is obtained.Then,the impacts of converters with different distances to the fault point on the fault current can be analyzed according to the high-frequency impedance characteristics.Based on the analysis results,a simplified fault current index(SFCI)is proposed to realize the fast evaluation of impact of grid topology on the fault current level.The SFCI is then applied to evaluate the relative fault current level.Finally,the simulation results validate the model,the analysis method,and the SFCI,which can effectively evaluate the relative fault current level in a direct and fast manner.展开更多
Pole-to-ground(PTG) fault analysis is of vital importance for high-voltage direct current(HVDC) grid. However, many factors are not considered in the existing studies such as the asymmetrical property of PTG fault, th...Pole-to-ground(PTG) fault analysis is of vital importance for high-voltage direct current(HVDC) grid. However, many factors are not considered in the existing studies such as the asymmetrical property of PTG fault, the coupling issue between DC transmission lines and the complexity of the structure of DC grid. This paper presents a PTG fault analysis method, which is based on common-and differential-mode(CDM)transformation. Similar to the symmetrical component method in AC system, the transformation decomposes the HVDC grid into CDM networks, which is balanced and decoupled. Then, a transfer impedance is defined and calculated based on the impedance matrices of the CDM networks. With the transfer impedance, analytical expressions of fault characteristics that vary with space and time are obtained. The proposed PTG fault analysis method is applicable to arbitrary HVDC grid topologies,and provides a new perspective to understand the fault mechanism. Moreover, the analytical expressions offer theoretical guidance for PTG fault protection. The validity of the proposed PTG fault analysis method is verified in comparison with the simulation results in PSCAD/EMTDC.展开更多
Symmetrical monopolar configuration is the prevailing scheme configuration for modular multilevel converter based high-voltage direct current(MMC-HVDC) links, in which severe DC overvoltage or overcurrent can be cause...Symmetrical monopolar configuration is the prevailing scheme configuration for modular multilevel converter based high-voltage direct current(MMC-HVDC) links, in which severe DC overvoltage or overcurrent can be caused by the DC faults. To deal with the possible asymmetry in the DC faults and the coupling effects of the DC lines, this paper analyzes the DC fault characteristics based on the phase-mode transformation. First, the DC grid is decomposed into the common-mode and the differential-mode networks. The equivalent models of the MMCs and DC lines in the two networks are derived, respectively. Then, based on the state matrices, a unified numerical calculation method for the fault voltages and currents at the DC side is proposed. Compared with the time-domain simulations performed on PSCAD/EMTDC, the accuracy of the proposed method is validated. Last, the system parameter analysis shows that the grounding parameters play an important role in reducing the severity of the pole-to-ground faults, whereas the coupling effects of the DC lines should be considered when calculating the DC fault currents associated with the pole-to-pole faults.展开更多
基金supported by the Science and Technology Project of State Grid Corporation of China“Cloud energy storage framework-based AI dispatching strategy of renewable energy integration and contingency response” (No.5100-202199274A-0-0-00)。
文摘The fault current level analysis is important for bipolar direct current(DC)grids,which determines the operation and protection requirements.The DC grid topology significantly impacts the current path and then the fault current level of the grid,which makes it possible to limit the fault current by optimizing the grid topology.However,the corresponding discussion in the literature is indigent.Aiming at this point,the impact of grid topology,i.e.,the connecting scheme of converters,on the pole-to-ground fault current in bipolar DC grids,is investigated in this paper,and the ground-return-based and metallic-return-based grounding schemes are considered,respectively.Firstly,the decoupled equivalent model in frequency domain for fault current analysis is obtained.Then,the impacts of converters with different distances to the fault point on the fault current can be analyzed according to the high-frequency impedance characteristics.Based on the analysis results,a simplified fault current index(SFCI)is proposed to realize the fast evaluation of impact of grid topology on the fault current level.The SFCI is then applied to evaluate the relative fault current level.Finally,the simulation results validate the model,the analysis method,and the SFCI,which can effectively evaluate the relative fault current level in a direct and fast manner.
基金supported in part by National Key Research and Development Program of China (No.2016YFB0900100)。
文摘Pole-to-ground(PTG) fault analysis is of vital importance for high-voltage direct current(HVDC) grid. However, many factors are not considered in the existing studies such as the asymmetrical property of PTG fault, the coupling issue between DC transmission lines and the complexity of the structure of DC grid. This paper presents a PTG fault analysis method, which is based on common-and differential-mode(CDM)transformation. Similar to the symmetrical component method in AC system, the transformation decomposes the HVDC grid into CDM networks, which is balanced and decoupled. Then, a transfer impedance is defined and calculated based on the impedance matrices of the CDM networks. With the transfer impedance, analytical expressions of fault characteristics that vary with space and time are obtained. The proposed PTG fault analysis method is applicable to arbitrary HVDC grid topologies,and provides a new perspective to understand the fault mechanism. Moreover, the analytical expressions offer theoretical guidance for PTG fault protection. The validity of the proposed PTG fault analysis method is verified in comparison with the simulation results in PSCAD/EMTDC.
文摘Symmetrical monopolar configuration is the prevailing scheme configuration for modular multilevel converter based high-voltage direct current(MMC-HVDC) links, in which severe DC overvoltage or overcurrent can be caused by the DC faults. To deal with the possible asymmetry in the DC faults and the coupling effects of the DC lines, this paper analyzes the DC fault characteristics based on the phase-mode transformation. First, the DC grid is decomposed into the common-mode and the differential-mode networks. The equivalent models of the MMCs and DC lines in the two networks are derived, respectively. Then, based on the state matrices, a unified numerical calculation method for the fault voltages and currents at the DC side is proposed. Compared with the time-domain simulations performed on PSCAD/EMTDC, the accuracy of the proposed method is validated. Last, the system parameter analysis shows that the grounding parameters play an important role in reducing the severity of the pole-to-ground faults, whereas the coupling effects of the DC lines should be considered when calculating the DC fault currents associated with the pole-to-pole faults.