期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Research on Program-controlled Power Source Based on DDS
1
作者 杨学蔚 公茂法 +2 位作者 公政 梁育雷 李保勇 《Journal of Measurement Science and Instrumentation》 CAS 2011年第1期75-77,共3页
Direct Digital Synthesis (DDS) chip was used in the design of program controlled power source in this paper. With the accurate control of Dual DDS chips by Micro Controller Unit (MCU), illter and power amplifier, ... Direct Digital Synthesis (DDS) chip was used in the design of program controlled power source in this paper. With the accurate control of Dual DDS chips by Micro Controller Unit (MCU), illter and power amplifier, this power source can generate voltage and corrent output with variable frequency, amplitude and phase. There are several advantages of this power source such as high power, high accuiracy, output stable, light and conveaient. 展开更多
关键词 DDS phase control power source program-controlled
下载PDF
Therapeutic effect of a dualchamber pacemaker with the optimized program-control mode on long-qt syndrome
2
作者 LUO Yuan-yuan,SUN Shao-xi,LI Heng,lI Yan,liu fu-qiang, MENG Su-rong,XU Ding-li,PENG Jian (Department of Cardiology,Nanfang Hospital,Southern Medical University,Guangzhou 510515,China) 《岭南心血管病杂志》 2011年第S1期92-92,共1页
Objectives To explore the optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital long QT syndrome(LQTS). Methods 12 LQTS patients in our hospital that still have symptom... Objectives To explore the optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital long QT syndrome(LQTS). Methods 12 LQTS patients in our hospital that still have symptoms despite use of regular drug therapies or that can not endure the therapies were implanted with DDD cardiac pacemaker.The QT/QTc intervals of those patients were measured at different pacing rates respectively.Their cardiac pacemakers were all programmed to selectively turn on and turn off some related functions at the pacing rate of 80 beats/min.The dosage ofβ-blockers was adjusted according to the patients’ PR intervals and blood pressures.The MACE and the cardiac function of the patients were recorded after operation.Results The measured QT / QTc interval decreased with the pacing rate increasing.The pacing rate of 80 beats/min can make QT/QTc interval basically normal. The MACE of the patients were statistically declined(P = 0.003) and no negative effect on cardiac function was found during the follow-up.Conclusions The optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital LQTS are:to pace at the rate of 80 beats/min and program to turn off lag,sleep,automatic preventing PMT and automatic threshold-capture feature and turn on the PVC,rate adaptation and atrioventricular node priority function. 展开更多
关键词 QTC MODE LQTS Therapeutic effect of a dualchamber pacemaker with the optimized program-control mode on long-qt syndrome
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部