期刊文献+
共找到851篇文章
< 1 2 43 >
每页显示 20 50 100
Atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction
1
作者 Ding-Han Zhu Xiong Zhang +3 位作者 Xiao-Qiang Li Peng Li Yan-Bin Wang Shuang Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期40-52,共13页
In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detect... In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detector following atmospheric transmission.To quantitatively analyze the effects of different satellite detection altitudes,burst heights,and transmission angles on the physical processes of X-ray transport and energy fluence,we developed an atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction.The proposed method is an improvement over the traditional analytical method that only computes direct-transmission X-rays.The traditional analytical method exhibits a maximum relative error of 67.79% compared with the Monte Carlo method.Our improved method reduces this error to within 10% under the same conditions,even reaching 1% in certain scenarios.Moreover,its computation time is 48,000 times faster than that of the Monte Carlo method.These results have important theoretical significance and engineering application value for designing satellite-borne nuclear detonation pulsed X-ray detectors,inverting nuclear detonation source terms,and assessing ionospheric effects. 展开更多
关键词 High-altitude nuclear detonation Atmospheric transmission pulsed x-rays Scattering correction Analytical method Monte Carlo method
下载PDF
Ultrafast two-dimensional x-ray imager with temporal fiducial pulses for laser-produced plasmas
2
作者 刘正东 仲佳勇 +21 位作者 远晓辉 张雅芃 姚嘉文 马作霖 徐向晏 薛彦华 张喆 袁大伟 张敏睿 李炳均 谷昊琛 戴羽 张成龙 董玉峰 周鹏 马鑫杰 马云峰 白雪洁 刘高扬 田进寿 赵刚 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期214-219,共6页
It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray s... It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray streak camera equipped with a row of multi-pinhole arrays. By processing multiple sets of one-dimensional streaked image data acquired from various pinholes, we are capable of reconstructing high-resolution two-dimensional images with a temporal resolution of 38 ps and a spatial resolution of 18 μm. The temporal fiducial pulses accessed from external sources can advance the precise timing and accurately determine the arrival time of the laser. Moreover, it can correct the nonlinear sweeping speed of the streak camera. The effectiveness of this diagnostic has been successfully verified at the Shenguang-II laser facility,providing an indispensable tool for observing complex physical phenomena, such as the implosion process of laser-fusion experiments. 展开更多
关键词 ultrafast diagnosis double-cone ignition x-ray streak camera pinhole array temporal fiducial pulses
原文传递
Extended Anode Effect for Tube Inner Coating of Non-Conductive Ceramics by Pulsed Coaxial Magnetron Plasma 被引量:2
3
作者 Musab Timan Idriss Gasab Hiroyuki Sugawara +1 位作者 Kei Sakata Hiroshi Fujiyama 《Materials Sciences and Applications》 2018年第1期1-10,共10页
For uniform tube inner coating of non-conductive thin films, the double-ended coaxial magnetron pulsed plasma (DCMPP) method was investigated. In this study, coating of TiN and TiO2 was performed. It was clearly shown... For uniform tube inner coating of non-conductive thin films, the double-ended coaxial magnetron pulsed plasma (DCMPP) method was investigated. In this study, coating of TiN and TiO2 was performed. It was clearly shown that the extended anode effect was strongly influenced by the electric resistance of the coated thin films on the inner surface of an insulator tube. Additionally, high frequency (100 kHz) was better for relatively high plasma density. On the other hand, in the case of titanium oxide deposition, negative ion productions drastically decrease the deposition rate and the shifting velocity of plasma main position for coated TiO2 films. 展开更多
关键词 Double-Ended COAXIAL MAGNETRON pulsed Plasma tube Inner Coating Extended Anode Effect Fine Ceramic FILMS TITANIUM Nitride FILMS TITANIUM Oxide FILMS
下载PDF
Influence of regenerator flow resistance on stability of pulse tube cooler 被引量:1
4
作者 蒋彦龙 陈国邦 《Journal of Southeast University(English Edition)》 EI CAS 2005年第3期277-281,共5页
Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigate... Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigated theoretically. The calculation results show that increasing regenerator flow resistance can lead to a smaller extent of DC flow.Therefore,a better stability performance of the cooler can be realized.On this basis,the stability characteristics of the cooler with various regenerator matrix arrangements are studied by experiments.By replacing 30% space of 247 screens of stainless steel mesh at the cold part of the regenerator by lead balls of 0.25 mm diameter,a long-time stable temperature output at 80 K region is achieved. This achievement provides a new way to obtain stable performance for pulse tube coolers at high temperature and is helpful for its application. 展开更多
关键词 pulse tube cooler flow resistance STABILITY
下载PDF
Treatment of Dye Wastewater by Using a Hybrid Gas/Liquid Pulsed Discharge Plasma Reactor 被引量:5
5
作者 鲁娜 李杰 +1 位作者 吴彦 佐藤正之 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第2期162-166,共5页
A hybrid gas/liquid pulsed discharge plasma reactor using a porous ceramic tube is proposed for dye wastewater treatment. High voltage pulsed discharge plasma was generated in the gas phase and simultaneously the plas... A hybrid gas/liquid pulsed discharge plasma reactor using a porous ceramic tube is proposed for dye wastewater treatment. High voltage pulsed discharge plasma was generated in the gas phase and simultaneously the plasma channel was permeated through the tiny holes of the ceramic tube into the water phase accompanied by gas bubbles. The porous ceramic tube not only separated the gas phase and liquid phase but also offered an effective plasma spreading channel. The effects of the peak pulse voltage, additive gas varieties, gas bubbling rate, solution conductivity and TiO2 addition were investigated. The results showed that this reactor was effective for dye wastewater treatment. The decoloration efficiency of Acid Orange II was enhanced with an increase in the power supplied. Under the studied conditions, 97% of Acid Orange II in aqueous solution was effectively decolored with additive oxygen gas, which was 51% higher than that with argon gas, and the increasing 02 bubbling rate also benefited the decoloration of dye wastewater. Water conductivity had a small effect on the level of decoloration. Catalysis of TiO2 could be induced by the pulsed discharge plasma and addition of TiO2 aided the decoloration of Acid Orange II. 展开更多
关键词 pulsed discharge plasma porous ceramic tube dye wastewater DECOLORATION
下载PDF
Improvements to conventional X-ray tube-based cone-beam computed tomography system 被引量:4
6
作者 Cui Zhang Xiao-Dong Pan +2 位作者 Hong-Jie Shang Yan-Hong Luo Gong-Ping Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第3期156-164,共9页
Conventional X-ray tube-based cone-beam computed tomography(CX-CBCT) systems have great potential in industrial applications. Such systems can rapidly obtain a three-dimensional(3D) image of an object.Conventional X-r... Conventional X-ray tube-based cone-beam computed tomography(CX-CBCT) systems have great potential in industrial applications. Such systems can rapidly obtain a three-dimensional(3D) image of an object.Conventional X-ray tubes fulfill the requirements for industrial applications, because of their high tube voltage and power. Continuous improvements have been made to CX-CBCT systems, such as imaging time shortening,acquisition strategy optimization, and imaging software development, etc. In this study, a CX-CBCT system is developed. Additionally, some improvements to the CX-CBCT system are proposed based on the hardware conditions of the X-ray tube and detector. A near-detector(ND)geometry condition is employed to obtain a sharper image and larger detection area. An improved acquisition strategy is proposed to simplify operations and reduce total imaging time. In the ND geometry condition, a simplified method called FBP slice stacking(SS-FBP) is proposed, which can be applied to 3D image reconstruction. SS-FBP is timesaving relative to traditional methods. Furthermore, imaging software for the CX-CBCT system is developed in the MATLAB environment. Several imaging experiments were performed. The results suggest that the CX-CBCT system works properly, and that the above improvements are feasible and practical. 展开更多
关键词 CONE-BEAM CT CONVENTIONAL x-ray tube NONDESTRUCTIVE testing x-ray imaging
下载PDF
Study on a 5.0 W/80 K single stage Stirling type pulse tube cryocooler 被引量:5
7
作者 Zhi-hua GAN Guo-jun LIU +4 位作者 Ying-zhe WO Qiang CAO Li-min QIU Guo-bang CHEN J.M. PFOTENHAUER 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第9期1277-1282,共6页
A single stage Stifling pulse tube cryocooler was designed based on REGEN 3.2 and fabricated for testing. The experimental results show that the cooler can provide a cooling capacity of 5.0 W at 79.1 K, and produce a ... A single stage Stifling pulse tube cryocooler was designed based on REGEN 3.2 and fabricated for testing. The experimental results show that the cooler can provide a cooling capacity of 5.0 W at 79.1 K, and produce a no-load temperature of 57.0 K, operating with an average pressure of 2.50 MPa and a frequency of 60 Hz, performance results that are very close to the calculated values. The cryocooler can be cooled from room temperature to 80 K in 8.5 min. The fast cooldown time is a result of the small regenerator. 展开更多
关键词 CRYOCOOLER REGENERATOR High frequency pulse tube
下载PDF
Experimental research on the feature of an x-ray Talbot–Lau interferometer versus tube accelerating voltage 被引量:3
8
作者 王圣浩 Margie P.Olbinado +7 位作者 Atsushi Momose 韩华杰 胡仁芳 王志立 高昆 张凯 朱佩平 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期673-678,共6页
X-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a con- ventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of sample... X-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a con- ventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of samples producing low absorption contrast, thus beating tremendous potential for future clinical diagnosis. In this work, by changing the accel- erating voltage of the x-ray tube from 35 kV to 45 kV, x-ray phase-contrast imaging of a test sample is performed at each integer value of the accelerating voltage to investigate the characteristic of an x-ray Talbot-Lau interferometer (located in the Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) versus tube voltage. Ex- perimental results and data analysis show that within a range this x-ray Talbot-Lau interferometer is not sensitive to the accelerating voltage of the tube with a constant fringe visibility of ~ 44%. This x-ray Talbot-Lau interferometer research demonstrates the feasibility of a new dual energy phase-contrast x-ray imaging strategy and the possibility to collect a refraction spectrum. 展开更多
关键词 x-ray Talbot-Lau interferometer x-ray imaging PHASE-CONTRAST tube accelerating voltage x-ray tube
原文传递
Generating femtosecond coherent X-ray pulses in a diffractionlimited storage ring with the echo-enabled harmonic generation scheme 被引量:5
9
作者 Wei-Hang Liu Guan-Qun Zhou Yi Jiao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第10期191-199,共9页
To study ultrafast processes at the sub-picosecond level, novel methods based on coherent harmonic generation technologies have been proposed to generate ultrashort radiation pulses in existing ring-based light source... To study ultrafast processes at the sub-picosecond level, novel methods based on coherent harmonic generation technologies have been proposed to generate ultrashort radiation pulses in existing ring-based light sources. Using the High Energy Photon Source as an example, we numerically test the feasibility of implementing one coherent harmonic generation technology, i.e.,the echo-enabled harmonic generation(EEHG) scheme, in a diffraction-limited storage ring(DLSR). Two different EEHG element layouts are considered, and the effect of the EEHG process on the electron beam quality is also analyzed. Studies suggest that soft X-ray pulses, with pulse lengths of a few femtoseconds and peak powers of up to1 MW, can be generated by using the EEHG scheme, while causing little perturbation to the regular operation of a DLSR. 展开更多
关键词 Echo-enabled harmonic generation Diffraction-limited storage ring HIGH-ENERGY PHOTON source FEMTOSECOND x-ray pulsES
下载PDF
Gas Flow in Unilateral Opening Pulse Tubes Based on Real Gas Equation of State 被引量:3
10
作者 代玉强 胡大鹏 +1 位作者 邹久朋 赵家权 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2009年第6期914-918,共5页
The real gas effect is dominant at high pressure and low temperature, and it is modeled by complex equations of state other than perfect gas law. In the vicinity of liquid-vapor critical point, the real gas exhibits u... The real gas effect is dominant at high pressure and low temperature, and it is modeled by complex equations of state other than perfect gas law. In the vicinity of liquid-vapor critical point, the real gas exhibits unusual gas dynamic behavior. In the present work, a transient wave fields in unilateral opening pulse tube is simulated by solving the Navier-Stokes equations incorporated with the Peng-Robinson thermodynamic model. The computational fluid dynamics (CFD) results show a remarkable deviation between perfect gas model and real gas model for contact interface and shockwave. The wave diagram based on the real gas model can help to solve the problem of offset design point. 展开更多
关键词 real gas flow pulse tube expansion refrigeration unsteady flow
下载PDF
Core-Excited Molecules by Resonant Intense X-Ray Pulses Involving Electron-Rotation Coupling 被引量:1
11
作者 Yanping Zhu Yanrong Liu +2 位作者 Xi Zhao Victor Kimberg Songbin Zhang 《Chinese Physics Letters》 SCIE CAS CSCD 2021年第5期21-26,共6页
It has been reported that electron-rotation coupling plays a significant role in diatomic nuclear dynamics induced by intense VUV pulses [Phys. Rev. A 102(2020) 033114;Phys. Rev. Res. 2(2020) 043348]. As a further ste... It has been reported that electron-rotation coupling plays a significant role in diatomic nuclear dynamics induced by intense VUV pulses [Phys. Rev. A 102(2020) 033114;Phys. Rev. Res. 2(2020) 043348]. As a further step, we present here investigations of the electron-rotation coupling effect in the presence of Auger decay channel for core-excited molecules, based on theoretical modeling of the total electron yield(TEY), resonant Auger scattering(RAS) and x-ray absorption spectra(XAS) for two showcases of CO and CH^(+) molecules excited by resonant intense x-ray pulses. The Wigner D-functions and the universal transition dipole operators are introduced to include the electron-rotation coupling for the core-excitation process. It is shown that with the pulse intensity up to 10^(16) W/cm^(2), no sufficient influence of the electron-rotation coupling on the TEY and RAS spectra can be observed. This can be explained by a suppression of the induced electron-rotation dynamics due to the fast Auger decay channel, which does not allow for effective Rabi cycling even at extreme field intensities,contrary to transitions in optical or VUV range. For the case of XAS, however, relative errors of about 10% and 30% are observed for the case of CO and CH^(+), respectively, when the electron-rotation coupling is neglected.It is concluded that conventional treatment of the photoexcitation, neglecting the electron-rotation coupling,can be safely and efficiently employed to study dynamics at the x-ray transitions by means of electron emission spectroscopy, yet the approximation breaks down for nonlinear processes as stimulated emission, especially for systems with light atoms. 展开更多
关键词 red Core-Excited Molecules by Resonant Intense x-ray pulses Involving Electron-Rotation Coupling
原文传递
An Improved Water-filled Pulse Tube Method Using Time Domain Pulse Separation Method 被引量:1
12
作者 Liang Sun Hong Hou 《Journal of Marine Science and Application》 2013年第1期122-125,共4页
Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method... Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500-2 000 Hz. 展开更多
关键词 pulse tube damped sine pulse water-air surface water-filled pulse tube
下载PDF
Reducing Radiation Dose by Using Pulse X-Ray Apparatus
13
作者 A. A. Komarskiy A. S. Chepusov +3 位作者 V. L. Kuznetsov S. R. Korzhenevskiy S. P. Niculin S. O. Cholakh 《Journal of Biosciences and Medicines》 2014年第2期17-21,共5页
Pulse X-ray diagnostics is capable of reducing the radiation exposure considerably. As for pulse X-ray diagnostic machines, which form pulses with the duration of 0.1 μs, using them one can get outstanding results in... Pulse X-ray diagnostics is capable of reducing the radiation exposure considerably. As for pulse X-ray diagnostic machines, which form pulses with the duration of 0.1 μs, using them one can get outstanding results in this area. This fact can be explained by the long period of luminophor persistence in intensifying X-ray luminescent screens. In this paper we present experimental data, comparing radiation doses, measured at pulse X-ray apparatus and apparatus of constant radiation. 展开更多
关键词 X-Radiation pulsE x-ray tube pulsE x-ray DIAGNOSTIC Ionizing RADIATION
下载PDF
Experimental Investigation of a Single-Stage Four-Valve Pulse Tube Refrigerator
14
作者 王坤 鲁雪生 顾安忠 《Journal of Shanghai Jiaotong university(Science)》 EI 2007年第1期96-99,105,共5页
In order to simplify the structure of the cold end of the pulse tube refrigerator (PTR) and have a better utilization of the cold energy of the system, a one-stage four-valve pulse tube refrigerator (FVPTR) with an &q... In order to simplify the structure of the cold end of the pulse tube refrigerator (PTR) and have a better utilization of the cold energy of the system, a one-stage four-valve pulse tube refrigerator (FVPTR) with an "L" type pulse tube structure and two orifice valves at the hot end of pulse tube has been constructed. Verification experiments show that the two orifice valve structure performs better than one orifice valve structure. A lowest temperature of 67.5 K was obtained at a frequency of 2.5 Hz under a system average pressure of 1.5 MPa with 200 mesh bronze screens as regenerator material, 80 mesh copper screens as stuffing material of heat exchanger. Due to the difficulty in manufacturing the thin "L" type pulse tube, the wall thickness of the pulse tube in the experiment was relatively difficult for us to reach 0.5 mm as that of the ordinary pulse tube, which resulted in relatively big system loss and affected the minimum temperature of the system to some degree. 展开更多
关键词 pulse tube refrigerator(PTR) "L" type pulse tube two orifice valves experimental investigation
下载PDF
Attosecond x-Ray Pulse Generation by Linear Thomson Scattering of Intense Laser Beam with Relativistic Electron
15
作者 TIAN You-Wei YU Wei +4 位作者 LU Pei-Xiang Vinod Senecha HE Feng DENG De-Gang XU Han 《Communications in Theoretical Physics》 SCIE CAS CSCD 2006年第1期167-170,共4页
Abstract Linear Thomson scattering of a short pulse laser by relativistic electron has been investigated using computer simulations. It is shown that scattering of an intense laser pulse of -33 fs full width at half m... Abstract Linear Thomson scattering of a short pulse laser by relativistic electron has been investigated using computer simulations. It is shown that scattering of an intense laser pulse of -33 fs full width at half maximum, with an electron of γ0 = 10 initial energy, generates an ultrashort, pulsed radiation of 76 attoseconds with a photon wavelength of 2.5 nm in the backward direction. The scattered radiation generated by a highly relativistic electron has superior quality in terms of its pulse width and angular distribution in comparison to the one generated by lower relativistic energy electron. 展开更多
关键词 attosecond pulse x-ray linear Thomson scattering relativistic electron
下载PDF
Suppression of Natural Convection in a Thermoacoustic Pulse Tube Refrigerator
16
作者 HAN Jun-Qing LIU Qiu-Sheng 《Chinese Physics Letters》 SCIE CAS CSCD 2013年第5期97-100,共4页
The effects of gravity on the efficiency of thermoacoustic engines are investigated theoretically and experimentally,especially for thermoacoustic pulse tube refrigerators.The significant effects of gravity are found ... The effects of gravity on the efficiency of thermoacoustic engines are investigated theoretically and experimentally,especially for thermoacoustic pulse tube refrigerators.The significant effects of gravity are found to be due to the presence of natural convection in the thermoacoustic pulse tube when the hot side of the tube is lower than the cold side.This kind of natural convection influences and reduces the efficiency of the thermoacoustic working system.Thus,how to suppress this natural convection becomes important for increasing the efficiency of thermoacoustic engines.Unlike the method of inserting a silk screen in a pulse tube,the present study uses a numerical simulation method to research the natural convection in pulse tubes,and we try to change the shape of the pulse tube to suppress this convection. 展开更多
关键词 pulsE pulsE tube
原文传递
DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER
17
作者 JIANGYan-long CHENGuo-bang THUMMESGuenter 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2004年第4期277-280,共4页
An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of t... An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively. 展开更多
关键词 pulse tube cooler DC flow SUPPRESSION
下载PDF
Quantum interference in laser-assisted photo-ionization excited by a femtosecond x-ray pulse
18
作者 葛愉成 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第12期4492-4497,共6页
The photoelectron energy spectra (PESs) excited by monochromatic femtosecond x-ray pulses in the presence of a femtosecond laser are investigated. APES is composed of a set of separate peaks, showing interesting com... The photoelectron energy spectra (PESs) excited by monochromatic femtosecond x-ray pulses in the presence of a femtosecond laser are investigated. APES is composed of a set of separate peaks, showing interesting comb-like structures. These structures result from the quantum interferences between photoelectron wave packets generated at different times. The width and the localization of each peak as well as the number of peaks are determined by all the laser and x-ray parameters. Most of peak heights of the PES are higher than the classical predictions. 展开更多
关键词 femtosecond x-ray pulse PHOTO-IONIZATION quantum interference photoelectron energy spectrum
原文传递
Growth of Erbium Dihydride Films under Low Hydrogen Pressure by Pulsed Laser Deposition
19
作者 王雪敏 SHEN Changle +5 位作者 WANG Yuying PENG Liping LI Weihua YAN Dawei 吴卫东 TANG Yongjian 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2015年第1期33-36,共4页
Erbium dihydride thin films were prepared by pulsed laser deposition on Si(100) substrates using erbium target under different low hydrogen pressures. The properties of these films were examined by atomic force micr... Erbium dihydride thin films were prepared by pulsed laser deposition on Si(100) substrates using erbium target under different low hydrogen pressures. The properties of these films were examined by atomic force microscopy, X-ray diffractometer, transmission electron microscopy, and Fourier transform infrared spectroscopy and UV-vis spectroscopy. Surface morphology reveals the smooth surface of these films (RMS: from 0.503 to 2.849 nm). The presence of obviously-broadened peaks for diffraction planes (111) suggests a presence of very tiny crystallites distributed along a preferred crystallographic orientation. Transmission electron microscopy investigations confirmed the formation of tiny crystallites due to the implantation of erbium ions. Due to the increase of nominal H concentration, the intensity of the broad absorbance from 190-260 nm increased. 展开更多
关键词 thin films pulsed laser deposition x-ray diffractometer transmission electron microscopy
原文传递
Synthesis of Crystalline Carbon Nitride Thin Films by Pulsed Arc Discharge at Atmospheric Pressure
20
作者 施昌勇 马志斌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第4期460-462,共3页
The preparation of crystalline C3N4 films was investigated using pulsed arc discharge from mixed methanol and ammonia water at atmospheric pressure. The X-ray diffraction (XRD) patterns of the films prepared at a su... The preparation of crystalline C3N4 films was investigated using pulsed arc discharge from mixed methanol and ammonia water at atmospheric pressure. The X-ray diffraction (XRD) patterns of the films prepared at a substrate temperature of 450℃ suggested that the film was composed of α-C3N4 and fl-C3N4 crystallites. Raman spectra exhibited distinct peaks which are in good agreement with those predicted theoretically for C3N4 crystallites. 展开更多
关键词 carbon nitride pulsed arc discharge x-ray diffraction Raman spectrum
下载PDF
上一页 1 2 43 下一页 到第
使用帮助 返回顶部