HJ-1A HSI on-orbit radiometric calibration and validation research 被引量:10
1
作者 GAO HaiLiang GU XingFa +3 位作者 YU Tao GONG Hui LI JiaGuo LI XiaoYing 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第11期3119-3128,共10页
The calibration experiment data at Dunhuang radiometric calibration site in October, 2008 were used to achieve the on-orbit radiometric calibration for HJ-1A hyper spectral imager (HSI). Two other field experiments da... The calibration experiment data at Dunhuang radiometric calibration site in October, 2008 were used to achieve the on-orbit radiometric calibration for HJ-1A hyper spectral imager (HSI). Two other field experiments data were used to validate the Dunhuang calibration results. One field experiment took place in Inner-Mongolia, China in September, 2008, and the other field experiment took place in Lake Frome, Australia in February, 2009. Finally, the ‘confidence interval of calibration error’ concept was put forward for quantitatively computing the calibration coefficient error confidence interval. The results showed that the Dunhuang calibration results in 2008 had high reliability. The confidence intervals of calibration error for all HSI channels were between 2% to 12%, which could satisfy the requirement of the HSI quantitative applications. 展开更多
关键词 HJ-1A hyper spectral imager(HSI) radiometric calibration VALIDATION confidence interval
原文传递
Terrain radiometric calibration of airborne UAVSAR for forested area 被引量:2
2
作者 CHENG Xiaoguang Naiara PINTO GONG Jianya 《Geo-Spatial Information Science》 SCIE EI 2012年第4期229-240,共12页
In the field of biomass estimation,terrain radiometric calibration of airborne polarimetric SAR data for forested areas is an urgent problem.Illuminated area correction ofσ-naught could not completely remove terrain ... In the field of biomass estimation,terrain radiometric calibration of airborne polarimetric SAR data for forested areas is an urgent problem.Illuminated area correction ofσ-naught could not completely remove terrain features.Inspired by Small and Shimada,this paper tested gamma-naught on one mountainous forested area using airborne Uninhabited Aerial Vehicle Synthetic Aperture Radar data and found it could remove most terrain features.However,a systematic increasing trend from far range to near range is found in airborne SAR cases.This paper made an attempt to use the relationship between distance to SAR sensor andγ-naught to calibrateγ-naught.Two quantitative evaluation methods are proposed.Experimental results demonstrate that variation ofγ-naught can be constrained to a limited extent from near range to far range.Since this method is based on ground range images,it avoids complicated orthorectification. 展开更多
关键词 terrain radiometric calibration UAVSAR sigma-naught γ-naught
原文传递
Radiometric calibration of hyper-spectral imaging spectrometer based on optimizing multi-spectral band selection
3
作者 孙立微 叶新 +3 位作者 方伟 何振磊 衣小龙 王玉鹏 《Optoelectronics Letters》 EI 2017年第6期405-408,共4页
Hyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of s... Hyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of source, an on-orbit radiometric calibration method is designed in this paper. This chain is based on the spectral inversion accuracy of the calibration light source. We compile the genetic algorithm progress which is used to optimize the channel design of the transfer radiometer and consider the degradation of the halogen lamp, thus realizing the high accuracy inversion of spectral curve in the whole working time. The experimental results show the average root mean squared error is 0.396%, the maximum root mean squared error is 0.448%, and the relative errors at all wavelengths are within 1% in the spectral range from 500 nm to 900 nm during 100 h operating time. The design lays a foundation for the high accuracy calibration of imaging spectrometer. 展开更多
关键词 In LENGTH radiometric calibration of hyper-spectral imaging spectrometer based on optimizing multi-spectral band selection
原文传递
Estimation of Thermal Imaging System Operating Range Based on Background Radiation 被引量:1
4
作者 Tingzhu Bai Long Shao +1 位作者 Heng He Peishan Song 《Journal of Beijing Institute of Technology》 EI CAS 2018年第2期241-249,共9页
Traditional operating range prediction methods assume that the atmospheric radiances in a target path and a background path are equal. But they are different in a real-world environment. To solve this problem,the infl... Traditional operating range prediction methods assume that the atmospheric radiances in a target path and a background path are equal. But they are different in a real-world environment. To solve this problem,the influence of atmospheric radiance on operating range prediction is analyzed in this paper. Range estimation model in thermal imaging based on background radiation( REBR) is proposed. Infrared image radiometric calibration is used to calculate the background radiation of a system entrance pupil. The result shows that,compared with traditional operating range prediction methods,the REBR method is more suitable for the actual atmospheric transmission process and the physical process of infrared imaging. 展开更多
关键词 atmospheric radiance operating range background radiation radiometric calibration