期刊文献+
共找到3,910篇文章
< 1 2 196 >
每页显示 20 50 100
Parametric resonance of axially functionally graded pipes conveying pulsating fluid
1
作者 Jie JING Xiaoye MAO +1 位作者 Hu DING Liqun CHEN 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第2期239-260,共22页
Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functio... Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functions of a simply supported beam.Via the direct multi-scale method,the response and stability boundary to the pulsating fluid velocity are solved analytically and verified by the differential quadrature element method(DQEM).The influence of Young's modulus gradient on the parametric resonance is investigated in the subcritical and supercritical regions.In general,the pipe in the supercritical region is more sensitive to the pulsating excitation.The nonlinearity changes from hard to soft,and the non-trivial equilibrium configuration introduces more frequency components to the vibration.Besides,the increasing Young's modulus gradient improves the critical pulsating flow velocity of the parametric resonance,and further enhances the stability of the system.In addition,when the temperature increases along the axial direction,reducing the gradient parameter can enhance the response asymmetry.This work further complements the theoretical analysis of pipes conveying pulsating fluid. 展开更多
关键词 pipe conveying fluid axially functionally graded supercritical resonance multi-scale method parametric resonance
下载PDF
Staging liver fibrosis with various diffusion-weighted magnetic resonance imaging models
2
作者 Yan-Li Jiang Juan Li +6 位作者 Peng-Fei Zhang Feng-Xian Fan Jie Zou Pin Yang Peng-Fei Wang Shao-Yu Wang Jing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1164-1176,共13页
BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diff... BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort.AIM To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances.METHODS This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants.All participants underwent multi-b value DWI.The main DWI-derived parameters included Mono-apparent diffusion coefficient(ADC)from mono-exponential DWI,intravoxel incoherent motion model-derived true diffusion coefficient(IVIM-D),diffusion kurtosis imaging-derived apparent diffusivity(DKI-MD),stretched exponential model-derived distributed diffusion coefficient(SEM-DDC),fractional order calculus(FROC)model-derived diffusion coefficient(FROC-D)and FROC model-derived microstructural quantity(FROC-μ),and continuous-time random-walk(CTRW)model-derived anomalous diffusion coefficient(CTRW-D)and CTRW model-derived temporal diffusion heterogeneity index(CTRW-α).The correlations between DWI-derived parameters and fibrosis stages and the parameters’diagnostic efficacy in detecting significant fibrosis(SF)were assessed and compared.RESULTS CTRW-D(r=-0.356),CTRW-α(r=-0.297),DKI-MD(r=-0.297),FROC-D(r=-0.350),FROC-μ(r=-0.321),IVIM-D(r=-0.251),Mono-ADC(r=-0.362),and SEM-DDC(r=-0.263)were significantly correlated with fibrosis stages.The areas under the ROC curves(AUCs)of the combined index of the six models for distinguishing SF(0.697-0.747)were higher than each of the parameters alone(0.524-0.719).The DWI models’ability to detect SF was similar.The combined index of CTRW model parameters had the highest AUC(0.747).CONCLUSION The DWI models were similarly valuable in distinguishing SF in patients with liver disease.The combined index of CTRW parameters had the highest AUC. 展开更多
关键词 Liver fibrosis Magnetic resonance imaging Diffusion-weighted magnetic resonance Liver biopsy Significant fibrosis
下载PDF
Enhanced resonance frequency in Co2FeAl thin film with different thicknesses grown on flexible graphene substrate
3
作者 周偲 袁少康 +8 位作者 朱登玉 白宇明 王韬 刘福福 潘禄禄 冯存芳 张博涵 何大平 汪胜祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期618-622,共5页
The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with un... The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with unique mechanical properties was extensively explored in high frequency devices.Herein,we report the characteristics of structure and magnetic properties at high frequency of Co2FeAl thin film with different thicknesses grown on flexible graphene substrate at room temperature.The exciting finding for the columnar structure of Co2FeAl thin film lays the foundation for excellent high frequency property of Co2FeAl/flexible graphene structure.In-plane magnetic anisotropy field varying with increasing thickness of Co2FeAl thin film can be obtained by measurement of ferromagnetic resonance,which can be ascribed to the enhancement of crystallinity and the increase of grain size.Meanwhile,the resonance frequency which can be achieved by the measurement of vector network analyzer with the microstrip method increases with increasing thickness of Co2FeAl thin film.Moreover,in our case with graphene film,the resonance magnetic field is quite stable though folded for twenty cycles,which demonstrates that good flexibility of graphene film and the stability of high frequency magnetic property of Co2FeAl thin film grown on flexible graphene substrate.These results are promising for the design of microwave devices and wireless communication equipment. 展开更多
关键词 enhanced resonance frequency magnetic resonance field flexible graphene substrate
原文传递
An underdamped and delayed tri-stable model-based stochastic resonance
4
作者 靳艳飞 王昊天 张婷婷 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期280-286,共7页
Stochastic resonance(SR) is investigated in an underdamped tri-stable potential system driven by Gaussian colored noise and a periodic excitation, where both displacement and velocity time-delayed states feedback are ... Stochastic resonance(SR) is investigated in an underdamped tri-stable potential system driven by Gaussian colored noise and a periodic excitation, where both displacement and velocity time-delayed states feedback are considered. It is challenging to study SR in a second-order delayed multi-stable system analytically. In this paper, the improved energy envelope stochastic average method is developed to derive the analytical expressions of stationary probability density(SPD)and spectral amplification. The effects of noise intensity, damping coefficient, and time delay on SR are analyzed. The results show that the shapes of joint SPD can be adjusted to the desired structure by choosing the time delay and feedback gains. For fixed time delay, the SR peak is increased for negative displacement or velocity feedback gain. Meanwhile, the SR peak is decreased while the optimal noise intensity increases with increasing correlation time of noise. The Monte Carlo simulations(MCS) confirm the effectiveness of the theoretical results. 展开更多
关键词 stochastic resonance underdamped tri-stable system spectral amplification time-delayed feedback
原文传递
Auto-parametric resonance of a continuous-beam-bridge model under two-point periodic excitation:an experimental investigation and stability analysis
5
作者 Li Yuchun Shen Chao +1 位作者 Liu Wei Li Dong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期445-454,共10页
The auto-parametric resonance of a continuous-beam bridge model subjected to a two-point periodic excitation is experimentally and numerically investigated in this study.An auto-parametric resonance experiment of the ... The auto-parametric resonance of a continuous-beam bridge model subjected to a two-point periodic excitation is experimentally and numerically investigated in this study.An auto-parametric resonance experiment of the test model is conducted to observe and measure the auto-parametric resonance of a continuous beam under a two-point excitation on columns.The parametric vibration equation is established for the test model using the finite-element method.The auto-parametric resonance stability of the structure is analyzed by using Newmark's method and the energy-growth exponent method.The effects of the phase difference of the two-point excitation on the stability boundaries of auto-parametric resonance are studied for the test model.Compared with the experiment,the numerical instability predictions of auto-parametric resonance are consistent with the test phenomena,and the numerical stability boundaries of auto-parametric resonance agree with the experimental ones.For a continuous beam bridge,when the ratio of multipoint excitation frequency(applied to the columns)to natural frequency of the continuous girder is approximately equal to 2,the continuous beam may undergo a strong auto-parametric resonance.Combined with the present experiment and analysis,a hypothesis of Volgograd Bridge's serpentine vibration is discussed. 展开更多
关键词 auto-parametric resonance continuous beam bridge model two-point excitation experimental investigation stability analysis vibration of Volgograd Bridge
下载PDF
Phonon resonance modulation in weak van der Waals heterostructures:Controlling thermal transport in graphene-silicon nanoparticle systems
6
作者 李毅 刘一浓 胡世谦 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期96-102,共7页
The drive for efficient thermal management has intensified with the miniaturization of electronic devices.This study explores the modulation of phonon transport within graphene by introducing silicon nanoparticles inf... The drive for efficient thermal management has intensified with the miniaturization of electronic devices.This study explores the modulation of phonon transport within graphene by introducing silicon nanoparticles influenced by van der Waals forces.Our approach involves the application of non-equilibrium molecular dynamics to assess thermal conductivity while varying the interaction strength,leading to a noteworthy reduction in thermal conductivity.Furthermore,we observe a distinct attenuation in length-dependent behavior within the graphene-nanoparticles system.Our exploration combines wave packet simulations with phonon transmission calculations,aligning with a comprehensive analysis of the phonon transport regime to unveil the underlying physical mechanisms at play.Lastly,we conduct transient molecular dynamics simulations to investigate interfacial thermal conductance between the nanoparticles and the graphene,revealing an enhanced thermal boundary conductance.This research not only contributes to our understanding of phonon transport but also opens a new degree of freedom for utilizing van der Waals nanoparticle-induced resonance,offering promising avenues for the modulation of thermal properties in advanced materials and enhancing their performance in various technological applications. 展开更多
关键词 thermal conductivity molecular dynamics phonon resonance van der Waals interaction graphene-silicon nanoparticle heterostructure
原文传递
Preoperative prediction of perineural invasion of rectal cancer based on a magnetic resonance imaging radiomics model:A dual-center study
7
作者 Yan Liu Bai-Jin-Tao Sun +3 位作者 Chuan Zhang Bing Li Xiao-Xuan Yu Yong Du 《World Journal of Gastroenterology》 SCIE CAS 2024年第16期2233-2248,共16页
BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for indivi... BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients. 展开更多
关键词 Rectal cancer Perineural invasion Magnetic resonance imaging Radiomics NOMOGRAM
下载PDF
Research and application of composite stochastic resonance in enhancement detection
8
作者 高蕊 焦尚彬 薛琼婕 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期264-273,共10页
Aiming at the problem that the intermediate potential part of the traditional bistable stochastic resonance model cannot be adjusted independently, a new composite stochastic resonance(NCSR) model is proposed by combi... Aiming at the problem that the intermediate potential part of the traditional bistable stochastic resonance model cannot be adjusted independently, a new composite stochastic resonance(NCSR) model is proposed by combining the Woods–Saxon(WS) model and the improved piecewise bistable model. The model retains the characteristics of the independent parameters of WS model and the improved piecewise model has no output saturation, all the parameters in the new model have no coupling characteristics. Under α stable noise environment, the new model is used to detect periodic signal and aperiodic signal, the detection results indicate that the new model has higher noise utilization and better detection effect.Finally, the new model is applied to image denoising, the results showed that under the same conditions, the output peak signal-to-noise ratio(PSNR) and the correlation number of NCSR method is higher than that of other commonly used linear denoising methods and improved piecewise SR methods, the effectiveness of the new model is verified. 展开更多
关键词 Woods–Saxon improved piecewise model composite stochastic resonance(SR) image denoising
原文传递
Current status of magnetic resonance imaging radiomics in hepatocellular carcinoma:A quantitative review with Radiomics Quality Score
9
作者 Valentina Brancato Marco Cerrone +2 位作者 Nunzia Garbino Marco Salvatore Carlo Cavaliere 《World Journal of Gastroenterology》 SCIE CAS 2024年第4期381-417,共37页
BACKGROUND Radiomics is a promising tool that may increase the value of magnetic resonance imaging(MRI)for different tasks related to the management of patients with hepatocellular carcinoma(HCC).However,its implement... BACKGROUND Radiomics is a promising tool that may increase the value of magnetic resonance imaging(MRI)for different tasks related to the management of patients with hepatocellular carcinoma(HCC).However,its implementation in clinical practice is still far,with many issues related to the methodological quality of radiomic studies.AIM To systematically review the current status of MRI radiomic studies concerning HCC using the Radiomics Quality Score(RQS).METHODS A systematic literature search of PubMed,Google Scholar,and Web of Science databases was performed to identify original articles focusing on the use of MRI radiomics for HCC management published between 2017 and 2023.The methodological quality of radiomic studies was assessed using the RQS tool.Spearman’s correlation(ρ)analysis was performed to explore if RQS was correlated with journal metrics and characteristics of the studies.The level of statistical significance was set at P<0.05.RESULTS One hundred and twenty-seven articles were included,of which 43 focused on HCC prognosis,39 on prediction of pathological findings,16 on prediction of the expression of molecular markers outcomes,18 had a diagnostic purpose,and 11 had multiple purposes.The mean RQS was 8±6.22,and the corresponding percentage was 24.15%±15.25%(ranging from 0.0% to 58.33%).RQS was positively correlated with journal impact factor(IF;ρ=0.36,P=2.98×10^(-5)),5-years IF(ρ=0.33,P=1.56×10^(-4)),number of patients included in the study(ρ=0.51,P<9.37×10^(-10))and number of radiomics features extracted in the study(ρ=0.59,P<4.59×10^(-13)),and time of publication(ρ=-0.23,P<0.0072).CONCLUSION Although MRI radiomics in HCC represents a promising tool to develop adequate personalized treatment as a noninvasive approach in HCC patients,our study revealed that studies in this field still lack the quality required to allow its introduction into clinical practice. 展开更多
关键词 Hepatocellular carcinoma Systematic review Magnetic resonance imaging Radiomics Radiomics quality score
下载PDF
Generation of lossy mode resonances(LMR)using perovskite nanofilms
10
作者 Dayron Armas Ignacio R.Matias +4 位作者 M.Carmen Lopez-Gonzalez Carlos Ruiz Zamarreño Pablo Zubiate Ignacio del Villar Beatriz Romero 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第2期33-40,共8页
The results presented here show for the first time the experimental demonstration of the fabrication of lossy mode resonance(LMR) devices based on perovskite coatings deposited on planar waveguides. Perovskite thin fi... The results presented here show for the first time the experimental demonstration of the fabrication of lossy mode resonance(LMR) devices based on perovskite coatings deposited on planar waveguides. Perovskite thin films have been obtained by means of the spin coating technique and their presence was confirmed by ellipsometry, scanning electron microscopy, and X-ray diffraction testing. The LMRs can be generated in a wide wavelength range and the experimental results agree with the theoretical simulations. Overall, this study highlights the potential of perovskite thin films for the development of novel LMR-based devices that can be used for environmental monitoring, industrial sensing, and gas detection, among other applications. 展开更多
关键词 PEROVSKITE thin films slab waveguide lossy mode resonance
下载PDF
Logical stochastic resonance in a cross-bifurcation non-smooth system
11
作者 张宇青 雷佑铭 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期659-667,共9页
This paper investigates logical stochastic resonance(LSR)in a cross-bifurcation non-smooth system driven by Gaussian colored noise.In this system,a bifurcation parameter triggers a transition between monostability,bis... This paper investigates logical stochastic resonance(LSR)in a cross-bifurcation non-smooth system driven by Gaussian colored noise.In this system,a bifurcation parameter triggers a transition between monostability,bistability and tristability.By using Novikov's theorem and the unified colored noise approximation method,the approximate Fokker-Planck equation is obtained.Then we derive the generalized potential function and the transition rates to analyze the LSR phenomenon using numerical simulations.We simulate the logic operation of the system in the bistable and tristable regions respectively.We assess the impact of Gaussian colored noise on the LSR and discover that the reliability of the logic response depends on the noise strength and the bifurcation parameter.Furthermore,it is found that the bistable region has a more extensive parameter range to produce reliable logic operation compared with the tristable region,since the tristable region is more sensitive to noise than the bistable one. 展开更多
关键词 logical stochastic resonance BIFURCATION mean first passage time
原文传递
Adaptive Bistable Stochastic Resonance Based Weak Signal Reception in Additive Laplacian Noise
12
作者 Jin Liu Zan Li +1 位作者 Qiguang Miao Li Yang 《China Communications》 SCIE CSCD 2024年第1期228-241,共14页
Weak signal reception is a very important and challenging problem for communication systems especially in the presence of non-Gaussian noise,and in which case the performance of optimal linear correlated receiver degr... Weak signal reception is a very important and challenging problem for communication systems especially in the presence of non-Gaussian noise,and in which case the performance of optimal linear correlated receiver degrades dramatically.Aiming at this,a novel uncorrelated reception scheme based on adaptive bistable stochastic resonance(ABSR)for a weak signal in additive Laplacian noise is investigated.By analyzing the key issue that the quantitative cooperative resonance matching relationship between the characteristics of the noisy signal and the nonlinear bistable system,an analytical expression of the bistable system parameters is derived.On this basis,by means of bistable system parameters self-adaptive adjustment,the counterintuitive stochastic resonance(SR)phenomenon can be easily generated at which the random noise is changed into a benefit to assist signal transmission.Finally,it is demonstrated that approximately 8dB bit error ratio(BER)performance improvement for the ABSR-based uncorrelated receiver when compared with the traditional uncorrelated receiver at low signal to noise ratio(SNR)conditions varying from-30dB to-5dB. 展开更多
关键词 adaptive bistable stochastic resonance additive Laplacian noise low signal to noise ratio uncorrelated reception scheme weak signal reception
下载PDF
Effect of magnetic resonance imaging in liver metastases
13
作者 Xing-Liang Huang Xiao-Dong Wang +2 位作者 Zhao-Miao Gong Yan-Feng Zheng Jing-Xin Mao 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期112-114,共3页
This letter to the editor is a commentary on a study titled"Liver metastases:The role of magnetic resonance imaging."Exploring a noninvasive imaging evaluation system for the biological behavior of hepatocel... This letter to the editor is a commentary on a study titled"Liver metastases:The role of magnetic resonance imaging."Exploring a noninvasive imaging evaluation system for the biological behavior of hepatocellular carcinoma(HCC)is the key to achieving precise diagnosis and treatment and improving prognosis.This review summarizes the role of magnetic resonance imaging in the detection and evaluation of liver metastases,describes its main imaging features,and focuses on the added value of the latest imaging tools(such as T1 weighted in phase imaging,T1 weighted out of phase imaging;diffusion-weighted imaging,T2 weighted imaging).In this study,I investigated the necessity and benefits of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid for HCC diagnostic testing and prognostic evaluation. 展开更多
关键词 Liver metastases Magnetic resonance imaging Liver-specific contrast agents Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid Hepatocellular carcinoma Hepatobiliary contrast agents
下载PDF
Brain mechanism of acupuncture for children with anisometropic amblyopia: a resting functional magnetic resonance imaging study based on voxel-mirrored homotopic connectivity
14
作者 Jue Wang Jing Jia +4 位作者 Yan Sun Chong-Bing Ma Yu-Zhu Chen An-Guo Liu Xing-Ke Yan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期339-347,共9页
AIM:To explore the brain mechanism of acupuncture for children with anisometropic amblyopia using the voxelmirror homotopic connectivity(VMHC)analysis method of resting functional magnetic resonance imaging(rs-fMRI)te... AIM:To explore the brain mechanism of acupuncture for children with anisometropic amblyopia using the voxelmirror homotopic connectivity(VMHC)analysis method of resting functional magnetic resonance imaging(rs-fMRI)technology based on clinical effectiveness.METHODS:Eighty children with anisometropic monocular amblyopia were randomly divided into two groups:control(40 cases,1 case of shedding)and acupuncture(40 cases,1 case of shedding)groups.The control group was treated with glasses,red flash,grating,and visual stimulations,with each procedure conducted for 5min per time.Based on routine treatment,the acupuncture group underwent acupuncture of“regulating qi and unblocking meridians to bright eyes”,Jingming(BL1),Cuanzhu(BL2),Guangming(GB37),Fengchi(GB20)acupoints were taken on both sides,with the needle kept for 30min each time.Both groups were treated once every other day,three times per week,for a total of 4wk.After the treatment,the overall curative effect of the two groups and the latency and amplitude changes of P100 wave of pattern visual-evoked potential were counted.At the same time,nine children with left eye amblyopia were randomly selected from the two groups and were scanned with rsfMRI before and after treatment.The differences in the brain regions between the two groups were compared and analyzed with VMHC.RESULTS:Chi-square test showed a notable difference in the total efficiency rate between the acupuncture(94.87%)and control groups(79.49%).Regarding the P100 wave latency and amplitude,the acupuncture group had significantly shorter latency and higher amplitude of P100 wave than the control group.Moreover,the VMHC values of the bilateral temporal lobe,superior temporal gyrus,and middle temporal gyrus were notably increased in the acupuncture group after treatment.CONCLUSION:Acupuncture combined with conventional treatment can significantly improve the corrected visual acuity and optic nerve conduction in children with anisometropic amblyopia.Compared with the conventional treatment,the regulation of acupuncture on the functional activities of the relevant brain areas in the anterior cerebellum may be an effective acupuncture mechanism for anisometropic amblyopia. 展开更多
关键词 resting functional magnetic resonance imaging voxel-mirror homotopy connection anisometropic amblyopia ACUPUNCTURE
原文传递
Magnetic resonance imaging of extraocular rectus muscles abnormalities in acute acquired concomitant esotropia
15
作者 Jia-Yu Chen Li-Rong Zhang +5 位作者 Jia-Wen Liu Jie Hao Hui-Xin Li Qiong-Yue Zhang Zhao-Hui Liu Jing Fu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期119-125,共7页
AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-con... AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-control study.Eighteen subjects with AACE and eighteen HCs were enrolled.MRI scanning data were conducted in target-controlled central gaze with a 3-Tesla magnetic resonance scanner.Extraocular muscles(EOMs)were scanned in contiguous image planes 2-mm thick spanning the EOM origins to the globe equator.To form posterior partial volumes(PPVs),the LR and MR cross-sections in the image planes 8,10,12,and 14 mm posterior to the globe were summed and multiplied by the 2-mm slice thickness.The data were classified according to the right eye,left eye,dominant eye,and non-dominant eye,and the differences in mean cross-sectional area,maximum cross-sectional area,and PPVs of the MR and LR muscle in the AACE group and HCs group were compared under the above classifications respectively.RESULTS:There were no significant differences between the two groups of demographic characteristics.The mean cross-sectional area of the LR muscle was significantly greater in the AACE group than that in the HCs group in the non-dominant eyes(P=0.028).The maximum cross-sectional area of the LR muscle both in the dominant and non-dominant eye of the AACE group was significantly greater than the HCs group(P=0.009,P=0.016).For the dominant eye,the PPVs of the LR muscle were significantly greater in the AACE than that in the HCs group(P=0.013),but not in the MR muscle(P=0.698).CONCLUSION:The size and volume of muscles dominant eyes of AACE subjects change significantly to overcome binocular diplopia.The LR muscle become larger to compensate for the enhanced convergence in the AACE. 展开更多
关键词 acute acquired concomitant esotropia magnetic resonance imaging extraocular muscles
原文传递
Nomogram prediction of vessels encapsulating tumor clusters in small hepatocellular carcinoma≤3 cm based on enhanced magnetic resonance imaging
16
作者 Hui-Lin Chen Rui-Lin He +5 位作者 Meng-Ting Gu Xing-Yu Zhao Kai-Rong Song Wen-Jie Zou Ning-Yang Jia Wan-Min Liu 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第5期1808-1820,共13页
BACKGROUND Vessels encapsulating tumor clusters(VETC)represent a recently discovered vascular pattern associated with novel metastasis mechanisms in hepatocellular carcinoma(HCC).However,it seems that no one have focu... BACKGROUND Vessels encapsulating tumor clusters(VETC)represent a recently discovered vascular pattern associated with novel metastasis mechanisms in hepatocellular carcinoma(HCC).However,it seems that no one have focused on predicting VETC status in small HCC(sHCC).This study aimed to develop a new nomogram for predicting VETC positivity using preoperative clinical data and image features in sHCC(≤3 cm)patients.AIM To construct a nomogram that combines preoperative clinical parameters and image features to predict patterns of VETC and evaluate the prognosis of sHCC patients.METHODS A total of 309 patients with sHCC,who underwent segmental resection and had their VETC status confirmed,were included in the study.These patients were recruited from three different hospitals:Hospital 1 contributed 177 patients for the training set,Hospital 2 provided 78 patients for the test set,and Hospital 3 provided 54 patients for the validation set.Independent predictors of VETC were identified through univariate and multivariate logistic analyses.These independent predictors were then used to construct a VETC prediction model for sHCC.The model’s performance was evaluated using the area under the curve(AUC),calibration curve,and clinical decision curve.Additionally,Kaplan-Meier survival analysis was performed to confirm whether the predicted VETC status by the model is associated with early recurrence,just as it is with the actual VETC status and early recurrence.RESULTS Alpha-fetoprotein_lg10,carbohydrate antigen 199,irregular shape,non-smooth margin,and arterial peritumoral enhancement were identified as independent predictors of VETC.The model incorporating these predictors demonstrated strong predictive performance.The AUC was 0.811 for the training set,0.800 for the test set,and 0.791 for the validation set.The calibration curve indicated that the predicted probability was consistent with the actual VETC status in all three sets.Furthermore,the decision curve analysis demonstrated the clinical benefits of our model for patients with sHCC.Finally,early recurrence was more likely to occur in the VETC-positive group compared to the VETC-negative group,regardless of whether considering the actual or predicted VETC status.CONCLUSION Our novel prediction model demonstrates strong performance in predicting VETC positivity in sHCC(≤3 cm)patients,and it holds potential for predicting early recurrence.This model equips clinicians with valuable information to make informed clinical treatment decisions. 展开更多
关键词 Small hepatocellular carcinoma Vessels encapsulating tumor clusters NOMOGRAM Magnetic resonance imaging MULTICENTER
下载PDF
Magnetic resonance imaging-based lymph node radiomics for predicting the metastasis of evaluable lymph nodes in rectal cancer
17
作者 Yong-Xia Ye Liu Yang +6 位作者 Zheng Kang Mei-Qin Wang Xiao-Dong Xie Ke-Xin Lou Jun Bao Mei Du Zhe-Xuan Li 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第5期1849-1860,共12页
BACKGROUND Lymph node(LN)staging in rectal cancer(RC)affects treatment decisions and patient prognosis.For radiologists,the traditional preoperative assessment of LN metastasis(LNM)using magnetic resonance imaging(MRI... BACKGROUND Lymph node(LN)staging in rectal cancer(RC)affects treatment decisions and patient prognosis.For radiologists,the traditional preoperative assessment of LN metastasis(LNM)using magnetic resonance imaging(MRI)poses a challenge.AIM To explore the value of a nomogram model that combines Conventional MRI and radiomics features from the LNs of RC in assessing the preoperative metastasis of evaluable LNs.METHODS In this retrospective study,270 LNs(158 nonmetastatic,112 metastatic)were randomly split into training(n=189)and validation sets(n=81).LNs were classified based on pathology-MRI matching.Conventional MRI features[size,shape,margin,T2-weighted imaging(T2WI)appearance,and CE-T1-weighted imaging(T1WI)enhancement]were evaluated.Three radiomics models used 3D features from T1WI and T2WI images.Additionally,a nomogram model combining conventional MRI and radiomics features was developed.The model used univariate analysis and multivariable logistic regression.Evaluation employed the receiver operating characteristic curve,with DeLong test for comparing diagnostic performance.Nomogram performance was assessed using calibration and decision curve analysis.RESULTS The nomogram model outperformed conventional MRI and single radiomics models in evaluating LNM.In the training set,the nomogram model achieved an area under the curve(AUC)of 0.92,which was significantly higher than the AUCs of 0.82(P<0.001)and 0.89(P<0.001)of the conventional MRI and radiomics models,respectively.In the validation set,the nomogram model achieved an AUC of 0.91,significantly surpassing 0.80(P<0.001)and 0.86(P<0.001),respectively.CONCLUSION The nomogram model showed the best performance in predicting metastasis of evaluable LNs. 展开更多
关键词 Radiomics Lymph node metastasis Rectal cancer Magnetic resonance imaging
下载PDF
Magnetic resonance imaging findings of radiation-induced breast angiosarcoma:A case report
18
作者 Wen-Pei Wu Chih-Wei Lee 《World Journal of Clinical Cases》 SCIE 2024年第13期2237-2242,共6页
BACKGROUND Breast conservation surgery(BCS)with adjuvant radiotherapy has become a gold standard in the treatment of early-stage breast cancer,significantly reducing the risk of tumor recurrence.However,this treatment... BACKGROUND Breast conservation surgery(BCS)with adjuvant radiotherapy has become a gold standard in the treatment of early-stage breast cancer,significantly reducing the risk of tumor recurrence.However,this treatment is associated with adverse effects,including the rare but aggressive radiation-induced angiosarcoma(RIAS).Despite its rarity and nonspecific initial presentation,RIAS presents a challenging diagnosis,emphasizing the importance of imaging techniques for early detection and accurate diagnosis.CASE SUMMARY We present a case of a 48-year-old post-menopausal woman who developed skin ecchymosis on the right breast seven years after receiving BCS and adjuvant radiotherapy for breast cancer.Initial mammography and ultrasound were inconclusive,showing post-treatment changes but failing to identify the underlying angiosarcoma.Contrast-enhanced breast magnetic resonance imaging(MRI)revealed diffuse skin thickening and nodularity with distinctive enhan-cement kinetics,leading to the diagnosis of RIAS.This case highlights the crucial role of MRI in diagnosing and determining the extent of RIAS,facilitating timely and appropriate surgical intervention.CONCLUSION Breast MRI is crucial for detecting RIAS,especially when mammography and ultrasound are inconclusive. 展开更多
关键词 Radiation-induced angiosarcoma RADIOTHERAPY Breast conserving surgery Breast cancer Magnetic resonance imaging Case report
下载PDF
High-grade pancreatic intraepithelial neoplasia diagnosed based on changes in magnetic resonance cholangiopancreatography findings:A case report
19
作者 Nao Furuya Atsushi Yamaguchi +13 位作者 Naohiro Kato Syuhei Sugata Takuro Hamada Takeshi Mizumoto Yuzuru Tamaru Ryusaku Kusunoki Toshio Kuwai Hirotaka Kouno Kazuya Kuraoka Yoshiyuki Shibata Sho Tazuma Takeshi Sudo Hiroshi Kohno Shiro Oka 《World Journal of Clinical Cases》 SCIE 2024年第8期1487-1496,共10页
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ... BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation. 展开更多
关键词 Pancreatic cancer Pancreatic intraepithelial neoplasm High-grade pancreatic intraepithelial neoplasm Magnetic resonance cholangiopancreatography Carcinoma in situ Case report
下载PDF
To explore the pathogenesis of anterior resection syndrome by magnetic resonance imaging rectal defecography
20
作者 Ling-Hou Meng Xian-Wei Mo +7 位作者 Bing-Yu Yang Hai-Quan Qin Qing-Zhou Song Xin-Xin He Qiang Li Zheng Wang Chang-Lin Mo Guo-Hai Yang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期529-538,共10页
BACKGROUND Over 90%of rectal cancer patients develop low anterior resection syndrome(LARS)after sphincter-preserving resection.The current globally recognized evaluation method has many drawbacks and its subjectivity ... BACKGROUND Over 90%of rectal cancer patients develop low anterior resection syndrome(LARS)after sphincter-preserving resection.The current globally recognized evaluation method has many drawbacks and its subjectivity is too strong,which hinders the research and treatment of LARS.AIM To evaluate the anorectal function after colorectal cancer surgery by quantifying the index of magnetic resonance imaging(MRI)defecography,and pathogenesis of LARS.METHODS We evaluated 34 patients using the standard LARS score,and a new LARS evaluation index was established using the dynamic images of MRI defecography to verify the LARS score.RESULTS In the LARS score model,there were 10(29.41%)mild and 24(70.58%)severe cases of LARS.The comparison of defecation rate between the two groups was 29.36±14.17%versus 46.83±18.62%(P=0.004);and MRI-rectal compliance(MRI-RC)score was 3.63±1.96 versus 7.0±3.21(P=0.001).Severe and mild LARS had significant differences using the two evaluation methods.There was a significant negative correlation between LARS and MRI-RC score(P<0.001),and they had a negative correlation with defecation rate(P=0.028).CONCLUSION MRI defecography and standard LARS score can both be used as an evaluation index to study the pathogenesis of LARS. 展开更多
关键词 Anterior resection syndrome Colorectal cancer Diagnostic evaluation system Magnetic resonance imaging defecography PATHOGENESIS
下载PDF
上一页 1 2 196 下一页 到第
使用帮助 返回顶部