This paper presents the development and testing of a novel internal dissipation connection for the use of post-tensioned rocking columns.The solution is one of the many referring to the dissipative controlled rocking(...This paper presents the development and testing of a novel internal dissipation connection for the use of post-tensioned rocking columns.The solution is one of the many referring to the dissipative controlled rocking(DCR)bridge design philosophy.The internal dissipaters are carefully designed to be cost-effective and reduce the over-all construction cost.The dissipaters are fully threaded,Grade 300 bars connected to the permanent column and foundation longitudinal reinforcement with threaded couplers.In this research,a DCR column is subjected to subsequent earthquake events,and the dissipaters’strain design limits are chosen such that there is no need for replacing after a significant seismic event.The result is a recommended design strain limit of 1.5%for the dissi-paters that guarantees the structural integrity of the DCR column after a seismic event.Additionally,a cumulated strain of 5%is recommended for the dissipaters before replacement is suggested.The proposed connection de-tailing with replaceable internal dissipaters,combined with post-tensioned high strength bars and well-confined concrete,provided self-centring capabilities(no residual displacement),dissipation capacity and significantly less damage in the bridge column than a traditional reinforced concrete solution.展开更多
文摘This paper presents the development and testing of a novel internal dissipation connection for the use of post-tensioned rocking columns.The solution is one of the many referring to the dissipative controlled rocking(DCR)bridge design philosophy.The internal dissipaters are carefully designed to be cost-effective and reduce the over-all construction cost.The dissipaters are fully threaded,Grade 300 bars connected to the permanent column and foundation longitudinal reinforcement with threaded couplers.In this research,a DCR column is subjected to subsequent earthquake events,and the dissipaters’strain design limits are chosen such that there is no need for replacing after a significant seismic event.The result is a recommended design strain limit of 1.5%for the dissi-paters that guarantees the structural integrity of the DCR column after a seismic event.Additionally,a cumulated strain of 5%is recommended for the dissipaters before replacement is suggested.The proposed connection de-tailing with replaceable internal dissipaters,combined with post-tensioned high strength bars and well-confined concrete,provided self-centring capabilities(no residual displacement),dissipation capacity and significantly less damage in the bridge column than a traditional reinforced concrete solution.