In this study,we present characteristics of post-sunset GHz scintillation occurrence and their correlations with ionospheric parameters derived from ionosonde observations in high solar activity years(2012−2013)of sol...In this study,we present characteristics of post-sunset GHz scintillation occurrence and their correlations with ionospheric parameters derived from ionosonde observations in high solar activity years(2012−2013)of solar cycle 24 at Sanya(18.3°N,109.6°E;dip lat.:12.8°N),China.The analyzed data include the F_(2)-layer’s critical frequency(foF_(2)),peak height(h_(m)F_(2)),and minimum virtual height(h’F),as well as the scale height around the F_(2)-layer peak(H_(m)),and virtual height(h’F_(5))and true height(hF_(5))measured at 5 MHz.We have investigated relationships between the equinoctial asymmetry of these scintillations and these ionospheric parameters.In addition,we calculate the growth rates of Rayleigh−Taylor instability on the basis of the ionosonde measurements and theoretical models,respectively.We find that the equinoctial asymmetry of scintillation onset time is associated with the scale length of the vertical electron density gradient(L),which has been shown to affect the growth of Rayleigh−Taylor instability at the bottom of the F-layer.The seasonal variations of foF_(2),H_(m)and scale length of vertical electron density gradient appear to cause the seasonal variations of scintillation occurrence;the equinoctial asymmetry of scintillation occurrence rate over low latitudes appears to be related to background electron density and vertical drifts in the F-layer around time of sunset.Further study is required to explain the observed correlational weakness in low latitudes between scintillation strength,represented by the daily maximum S4,and daily maximum values of foF_(2),h_(m)F_(2),h’F,H_(m),and also the drifts.展开更多
The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillati...The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillation fiber dosimeter(PSFD)with a current readout mode,systematic studies of the stability and light-dose response were performed for the photomultiplier tube(PMT),silicon photomultiplier(SiPM),avalanche photodiode(APD),and photodiode(PD).The temperature stability,long-term stability,repeatability,signal-to-noise ratio(SNR),and current dose response of the PSFD with the abovementioned photoelectric devices were studied using a pulsed LED light source and the Small Animal Radiation Therapy platform.An exponential relationship between the dark/ne current and temperature was obtained for all the devices.I is shown that the APD is the most sensitive device to temperature,with a current dependence on temperature reaching 6.5%C^(-1)at room temperature,whereas for the other devices this dependence is always<0:6%C^(-1).In terms of long-term stability,the net current of PD can change by up to 4%when working continuously for 8 h and 2%when working intermittently for 32 h,whereas for the other devices,the changes are all<1%.For the dose response,the PMT and SiPM exhibit excellent linear responses and SNRs within the range of 0.1-60 Gy/min For the PSFD with a current readout mode,the performance of the PMT and SiPM is concluded to be better than that of the other devices in the study.In particular,the SiPM,which has a compact size,low bias voltage,and antimagnetic interference,has great advantages for further applications.展开更多
In the present work, we designed the new type of photonic crystals (PCs) as reflectors. Reflections from single layer of Al2O3/MgO PC help us in recapturing the light that does escape from the scintillation surface. P...In the present work, we designed the new type of photonic crystals (PCs) as reflectors. Reflections from single layer of Al2O3/MgO PC help us in recapturing the light that does escape from the scintillation surface. Photonic crystals in one dimension array of Al2O3 and MgO with silver at periodicities N = 1, 2 and 3 were used as a reflector around the surface of the scintillation volume. Scintillation detectors are widely used in nuclear medicine. The efficiency is an important parameter for characterizing the capability of the detectors. The counting efficiency of the detectors depends on the light emission induced by radiation. The light then was converted by the photomultiplier tube into electrical pulses. The efficiency may increase by an amount of 1.64% if MgO-Ag photonic crystals are used at periodicity N = 1 as a reflector.展开更多
A method of measuring the tritium in seawater based on electrolytic enrichment and ultra-low background liquid scintillation counting techniques was established.The different factors influencing the detection limit we...A method of measuring the tritium in seawater based on electrolytic enrichment and ultra-low background liquid scintillation counting techniques was established.The different factors influencing the detection limit were studied,including the counting time,the electrolytic volume of the seawater samples,the selection of background water,scintillation solution and their ratio.After optimizing the parameters and electrolyzing 350 mL volume of samples,the detection limit of the method was as low as 0.10 Bq/L.In order to test the optimization of system for this method,of the 84 seawater samples collected from the Arctic Ocean we measured,92%were above the detection limit(the activity of this samples ranged from 0.10 Bq/L to 1.44 Bq/L with an average of(0.30±0.24)Bq/L).In future research,if we need to accurately measure the tritium activity in samples,the volume of the electrolytic samples will be increased to further reduce the minimum detectable activity.展开更多
Formation elements logging is a neutron gamma spectroscopy logging technique used to acquire the content of elements and minerals by recording the gamma ray produced by the reaction of neutron and elemental nucleus in...Formation elements logging is a neutron gamma spectroscopy logging technique used to acquire the content of elements and minerals by recording the gamma ray produced by the reaction of neutron and elemental nucleus in the formation. It has a wide usage in discriminating complex lithology and evaluating unconventional reservoir. The Monte Carlo simulation model of formation elements logging tool is established in this paper, with which the effects of tool parameters including the material and length of the scintillation crystal and source spacing on logging responses are modeled. The results show that the energy response of LaBr_3: Ce crystal is better than others, and the detection efficiency increases with the crystal length but decrease with source spacing. The above results may be used as a reference for optimizing the tool structure design.展开更多
The observations of Global Positioning System(GPS) scintillation,Total Electron Content(TEC)depletion,the periodic structure of TEC and Rate of TEC Index(ROTI) over south China were presented.Data were collected from ...The observations of Global Positioning System(GPS) scintillation,Total Electron Content(TEC)depletion,the periodic structure of TEC and Rate of TEC Index(ROTI) over south China were presented.Data were collected from GPS observations at stations of Shenzhen and Guangzhou from 2011 to 2012.This study reported that the ratio of simultaneous occurrences of TEC depletions with strong scintillations was higher than that of TEC depletions with weak scintillations in vernal and autumnal equinoxes of 2011 over South China.The number of the periodic structures of TEC with depletion contained was greater than that with no depletion contained corresponding to strong scintillations.The structure of the slab of plasma irregularities could be responsible for the simultaneous occurrences of TEC depletion with strong scintillations and ROTI.Before and during the occurrences of strong scintillation,there was Large-Scale Wave Structure(LSWS) which provided the seed ionization perturbation to trigger ESF irregularities and contributed to the periodic structure of TEC.展开更多
In the equatorial region,deep amplitude fading in global positioning system(GPS)signals frequently occurs during the strong ionospheric scintillation,it can lead to the loss of lock in GPS carrier tracking loops,and r...In the equatorial region,deep amplitude fading in global positioning system(GPS)signals frequently occurs during the strong ionospheric scintillation,it can lead to the loss of lock in GPS carrier tracking loops,and result in increased positioning error and even navigation interruption.The relationships between amplitude scintillation indices and detrended carrier frequency are investigated,based on GPS L1 C/A signals during the last peak of the solar cycle at the low latitude site of São Josédos Campos,Brazil(23.2S,45.9W)from 2013 to 2015.Corresponding mathematic model of the probability distribution function is built for the first time to provide statistical analysis on the above relationships.The results show that the standard carrier frequencies reveal an almost linear relation with the amplitude scintillation indices.Moreover,the frequency widths of detrended frequency are proportional to levels of amplitude scintillation when the value of the peak probability is lower than the corresponding boundary.A conclusion can be drawn that different levels of amplitude scintillation will influence the fluctuation of the carrier frequency.The analysis will provide useful guidance to set the receiver’s bandwidth with respect to the different scintillation levels and design the advanced tracking algorithms to improve the robustness and precision of the GPS receiver.展开更多
In this study, a scintillation detector was developed to measure the space proton effective dose for astronauts based on the proton effective dose conversion coefficients provided by International Commission on Radiol...In this study, a scintillation detector was developed to measure the space proton effective dose for astronauts based on the proton effective dose conversion coefficients provided by International Commission on Radiological Protection Report No. 116. In the Monte Carlo N-Particle Transport Code X(version 2.6.0) simulation process, by modulating the depth and solid angle of truncated conical holes in an iron shell from lower-energy protons to higher-energy protons, the energy deposited in the scintillator by isotropic protons was nearly proportional to the corresponding effective dose, with a maximum relative deviation of 13.28% at thirteen energy points in the energy range of 10–400 MeV. Therefore, the detector can monitor proton effective dose indirectly in real time by measuring the deposited energy. We calibrated the photoelectric conversion efficiency of the detector at the cobalt source, tested the response of the detector in the energy range of 30–100 MeV in unidirectional proton field, and validated the simulation with the experimental results.展开更多
Besides their intended use in radio navigation, global positioning system (GPS) satellite signals provide convenient radio beacons for ionospheric studies. Among other propagation phenomena, the ionosphere affects GPS...Besides their intended use in radio navigation, global positioning system (GPS) satellite signals provide convenient radio beacons for ionospheric studies. Among other propagation phenomena, the ionosphere affects GPS signal propagation through amplitude scintillations that develop after radio waves propagation through ionospheric electron density irregularities. This paper outlines the design, testing, and results of a specialized GPS receiver to monitor L-band scintillations. The scintillation monitor system consists of a commercial GPS receiver development kit with its software designed to log signal strength and carrier phase from up to 12 channels at one sample per second rate. Other prime features of the monitor include the data compression, transmission and processing. Here is the fact that they are inexpensive and compact and therefore can be readily proliferated.展开更多
As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main me...As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources.The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel.GRAND is the largest neutrino detection array to be built in China.GRANDProto35,as the first stage of the GRAND experiment,is a coincidence array composed of radio antennas and a scintillation detector,the latter of which,as a traditional detector,is used to perform cross-validation with radio detection,thus verifying the radio detection efficiency and enabling study of the background exclusion method.This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35.A package based on GEANT4 was used to simulate the details of the scintillation detector,including the optical properties of its materials,the height of the light guide box,and position inhomogeneity.The surface of the scintillator and the reflective materials used in the detector was optimized,and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied.According to the simulation study,the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface,with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m^(2).The performance of the detector was tested in detail through a coincidence experiment,and the test results showed that the number of photoelectrons collected in the detector was$84 with a time resolution of~1 ns,indicating good performance.The simulation results were consistent with those obtained from the tests,which also verified the reliability of the simulation software.These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.展开更多
The amplitude and phase of L-band satellite signals are fluctuated randomly due to small scale electron density irregularity structures in the ionosphere which result in fleeting variations, known as 'ionospheric ...The amplitude and phase of L-band satellite signals are fluctuated randomly due to small scale electron density irregularity structures in the ionosphere which result in fleeting variations, known as 'ionospheric scintillations'. The Global Navigation Satellite System(GNSS) is a profound remote sensing tool to monitor, model and forecast the ionospheric weather conditions. In this paper, the GNSS amplitude scintillation data has been analyzed during the year 2013 at Bengaluru(12.9°N, 77.59°E) and Lucknow(26.8467°N, 80.9462°E) stations to reinforce climatology of ionospheric scintillation over Indian low-latitude region. The probability of scintillation occurrence and their variations over equatorial and Equatorial Ionization Anomaly(EIA) regions in India are analyzed during various geomagnetic quiet and disturbed days, months and seasons. The annual occurrence of amplitude scintillations are mapped with the function of local time. It is observed from the experimental results that the probability of scintillations occurrences is higher over EIA region than over the equatorial region. The probability of scintillations is higher during March equinox and December solstice, and lowest during June solstice.Distribution of scintillations is intense during post-sunset period. The maximum percentage of scintillation occurrences at the two stations are recorded in November. Moreover, the highest percentage of scintillation occurrences took place on storm day(March 17, 2013) at the two stations. This work would be helpful for understanding the features of GNSS amplitude scintillations over Southern and Northern Indian regions. Moreover, these kinds of investigations are helpful for developing new algorithms to nowcast and forecast ionospheric scintillations over Indian Sub-continent.展开更多
A theoretical formula for measuring the power-law spectrum with interferometer is presented inthis paper for the study of ionosphere.The results of theoretical calculation agree well with themeasurements.The radio sci...A theoretical formula for measuring the power-law spectrum with interferometer is presented inthis paper for the study of ionosphere.The results of theoretical calculation agree well with themeasurements.The radio scintillation power-law spectrum index which is caused by the irregulanrities in theionosphere is determined to be p=3.5 from the results.展开更多
The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete mat...The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete material.To address this problem,an in-situ and nondestructive analysis method was developed to determineγ-ray-emitting nuclides and their specific activities in the concrete walls and floor by using a portable germanium semiconductor detector.In this work,we examined a substitute for Ge detector to establish a simpler and more convenient method.As candidates,we focused on some scintillation type spectrometers,and the possibility of a substitute for a Ge detector was examined by both simulation and experiment.The detection limits were roughly estimated through Monte Carlo simulation for various scintillation crystals,and it was found that 1.5-inch LaBr3,CeBr3,and SrI2 could distinguish the clearance level.It was confirmed that the 1.5-inch LaBr3 could reproduce the calibration curve of the Ge detector in the experiment.The required thickness and length of the radiation shield for suppressing the background radiation during the measurement was also determined for the convenience of an actual decommissioning work.展开更多
We estimate the zonal drift velocity of small-scale ionospheric irregularities at low latitude by leveraging the spaced-receivers technique applied to two GNSS receivers for scintillation monitoring installed along th...We estimate the zonal drift velocity of small-scale ionospheric irregularities at low latitude by leveraging the spaced-receivers technique applied to two GNSS receivers for scintillation monitoring installed along the magnetic parallel passing in Presidente Prudente(Brazil,magnetic latitude 12.8°S).The investigated ionospheric sector is ideal to study small-scale irregularities,being located close to the expected position of the southern crest of the equatorial ionospheric anomaly.The measurement campaign took place between September 2013 and February 2014,i.e.equinox and summer solstice seasons under solar maximum,during which the probability of formation of small-scale irregularities is expected to maximize.We found that the hourly average of the velocity increases up to 135 m/s right after the local sunset at ionospheric altitudes and then smoothly decreases in the next hours.Such measurements are in agreement with independent estimations of the velocity made by the Incoherent Scatter Radar located at the Jicamarca Radio Observatory(magnetic latitude 0.1°N),by the Boa Vista Ionosonde(magnetic latitude 12.0°N),and by applying a recently-developed empirical regional short-term forecasting model.Additionally,we investigated the relationship with the percentage occurrence of amplitude scintillation;we report that it is exponentially dependent on the zonal velocity of the irregularities that cause it.展开更多
Emission spectra,longitudinal transmission and light output for the Sb-doped and Y-doped PbWO_(4) crystals are presented.Scintillation decay kinetics has been measured by using gate integration and single photon count...Emission spectra,longitudinal transmission and light output for the Sb-doped and Y-doped PbWO_(4) crystals are presented.Scintillation decay kinetics has been measured by using gate integration and single photon counting method with blue and green filters.Radiation hardness has also been measured by using ^(60)Coγ-ray irradiation under different dose rates and different dose rate profiles.The light yield and radiation hardness of the Sb-doped and Y-doped PbWO_(4) crystals are improved as compared to the undoped crystals and are suitable for the requirements of compact muon solenoid.展开更多
With the rapid demand for underwater optical communication(UOC), studies of UOC degradation by oceanic turbulence have attached increasing attention worldwide and become a research hot-spot in recent years. Previous s...With the rapid demand for underwater optical communication(UOC), studies of UOC degradation by oceanic turbulence have attached increasing attention worldwide and become a research hot-spot in recent years. Previous studies used a simplified and inaccurate oceanic turbulence spectrum, in which the eddy diffusivity ratio between temperature and salinity is assumed to be unity and the outer scale of turbulence is assumed to be infinite. However, both assumptions are not true in most of the actual marine environments. In this paper, based on the Rytov theory in weak turbulence, we derive analytical expressions of "the aperture-averaged scintillation index"(SI) for both plane and spherical waves, which can clearly demonstrate how SI is influenced by several key factors in UOC. Then, typical fade statistics of the UOC system in weak turbulence is discussed including the probability of fade, the expected number of fades per time, the mean fade time,signal-to-noise ratio and bit error rate. Our results show that spherical wave is preferable in the UOC system in weak turbulence compared to plane wave, and the aperture-averaged effect has a significant impact on UOC system's performance.Our results can be used to determine those key parameters for designing the UOC system over reasonable ranges.展开更多
The 2 nd Equatorial Plasma Bubble(EPB)workshop,funded by the Institute of Geology and Geophysics,Chinese Academy of Sciences,and the National Natural Science Foundation of China,took place in Beijing,China during Sept...The 2 nd Equatorial Plasma Bubble(EPB)workshop,funded by the Institute of Geology and Geophysics,Chinese Academy of Sciences,and the National Natural Science Foundation of China,took place in Beijing,China during September 13–15,2019.The EPB workshop belongs to a conference series that began in 2016 in Nagoya,Japan at the Institute for Space-Earth Environmental Research,Nagoya University,resulting in a special issue of Progress in Earth and Planetary Science that focused on EPBs.The main goal of the series is to organize in-depth discussion by scientists working on ionospheric irregularities,and solve the scientific challenges in EPB and ionospheric scintillation forecasting.The 2 nd EPB workshop gathered almost 60 scientists from seven countries.A total of 20 invited and contributing papers focusing on ionospheric irregularities and scintillations were presented.Here we briefly comment on 10 papers included in this special issue.展开更多
Based on the theory of optical scintillation induced by fluctuation of particulate concentration, a Gas Flow Velocity Measurement System (GFVMS) is proposed to measure the gas flow velocity in stack. Verification expe...Based on the theory of optical scintillation induced by fluctuation of particulate concentration, a Gas Flow Velocity Measurement System (GFVMS) is proposed to measure the gas flow velocity in stack. Verification experiments on simulation flue indicate that, for the smoothing effect of transmitting and receiving apertures, optical scintillation induced by refractive index fluctuation is very weak. When particles are added into gas flow, the standard deviation of optical scintillation increased obviously. And when the particulate number concentration exceeds 4000/m3, the GFVMS can work normally, and the variation range of measured velocities is almost the same with that of Pitot tube. Sensitivity testing results show that, GFVMS is very sensitive to velocity change. Results of outfield experiment prove that, velocities measured by GFVMS are more stable and the average velocity (7.62/s) is very close to the statistical average (7.61 m/s) of velocities measured by Pitot tube at different points along optical path.展开更多
Throughout the United States, laboratories use different sampling methods (“Direct Fill” vs. “Submerged Bottle” methods), sample preparations (“Simultaneous Drawing” vs. “Separate Drawing”), scintillators (“M...Throughout the United States, laboratories use different sampling methods (“Direct Fill” vs. “Submerged Bottle” methods), sample preparations (“Simultaneous Drawing” vs. “Separate Drawing”), scintillators (“Mineral Oil” vs. “Opti-Fluor”), volume of water plus scintillator in the cocktail (“8 mL plus 8 mL” vs. “10 mL plus 10 mL”), and liquid scintillation counting assays (“Full Spectrum: 0 - 2000 keV” vs. “Region of Interest: 130 - 700 keV”) for analyzing radon (222Rn) in water. We compared these and few other variables on the recovery of radon from two “Proficiency Test (PT)” samples and four “Household Well Water” samples from Georgia. The “130 - 700 keV” assay had significantly higher radon recovery than the “0 - 2000 keV” assay. The “Direct Fill” sampling produced significantly lower radon recovery than the “Submerged Bottle” sampling. “Simultaneous Drawing” of both scintillator and water sample yielded higher radon recovery than “Separate Drawing”. Air bubble in the samples resulted in significant loss of radon gas;and such loss became greater as the air bubble was larger. A “10 mL scintillator + 10 sample” combination appeared better than “8 mL scintillator + 8 mL sample”. Mixing scintillator and sample in the laboratory, when compared with doing it on-site, was found superior for better results and practicality of testing radon in private well waters. “Mineral Oil” scintillator provided higher radon activity than “Opti-Fluor”. However, in 10 consecutive measurements of the two proficiency test (PT) samples at 60 days interval (i.e., with full ingrowing), “Mineral Oil” overestimated the radon activity compared to the predicted/assigned value in most cases, whereas “Opti-Fluor” invariably produced results close to the predicted/assigned value. There were noticeable temporal variations in both radon and uranium concentrations in the study wells;nevertheless, uranium and radon concentrations had good positive correlation. Despite this, the use of uranium concentration over 30 ppb (the MCL of uranium in drinking water) as a trigger for recommending test for radon in well water remains questionable because there may be the safe level of uranium but unsafe level of radon in a well and vice versa.展开更多
The present work examines the validity of using barium as a carrier for radium-226 determination and optimizes the amount added during the radiochemical separation from rock samples. The activity concentration of Ra-2...The present work examines the validity of using barium as a carrier for radium-226 determination and optimizes the amount added during the radiochemical separation from rock samples. The activity concentration of Ra-226 is determined in rock samples by liquid scintillation spectrometer via its short-lived daughters after the radiochemical separation. The activity of Ra-226 was calculated based on the counts measured in a window set for Po-214 peak. The activity measured by Liquid Scintillation Counter, LSC using Pulse Shape Analysis, PSA. Ba-133 was used for chemical yield. The applied method was tested using a Certified Reference Material, CRM ore number-Dl-1a which shows a good agreement with the certified values. The applied method for measuring Ra-226 has been adapted to be used in rocks such as monazite. The average activity for Ra-226 in rock samples collected from the commercial grade Egyptian monazite was 13.85 ± 2.05 Bq/g with a detection limit 9.58 mBq/g. The optimum conditions have been established during the present work such as precision, cost and time preparation which makes the method useful for radio chemists and the decision makers.展开更多
基金supported by the Fundamental Research Funds for the Central Universities,South-Central MinZu University(Grant Number:CPT22019).
文摘In this study,we present characteristics of post-sunset GHz scintillation occurrence and their correlations with ionospheric parameters derived from ionosonde observations in high solar activity years(2012−2013)of solar cycle 24 at Sanya(18.3°N,109.6°E;dip lat.:12.8°N),China.The analyzed data include the F_(2)-layer’s critical frequency(foF_(2)),peak height(h_(m)F_(2)),and minimum virtual height(h’F),as well as the scale height around the F_(2)-layer peak(H_(m)),and virtual height(h’F_(5))and true height(hF_(5))measured at 5 MHz.We have investigated relationships between the equinoctial asymmetry of these scintillations and these ionospheric parameters.In addition,we calculate the growth rates of Rayleigh−Taylor instability on the basis of the ionosonde measurements and theoretical models,respectively.We find that the equinoctial asymmetry of scintillation onset time is associated with the scale length of the vertical electron density gradient(L),which has been shown to affect the growth of Rayleigh−Taylor instability at the bottom of the F-layer.The seasonal variations of foF_(2),H_(m)and scale length of vertical electron density gradient appear to cause the seasonal variations of scintillation occurrence;the equinoctial asymmetry of scintillation occurrence rate over low latitudes appears to be related to background electron density and vertical drifts in the F-layer around time of sunset.Further study is required to explain the observed correlational weakness in low latitudes between scintillation strength,represented by the daily maximum S4,and daily maximum values of foF_(2),h_(m)F_(2),h’F,H_(m),and also the drifts.
基金supported by the China Postdoctoral Science Foundation(No.2017M621818)the National Key Research and Development Project(Nos.2017YFF0206205 and2016YFB0501303)+1 种基金the National Natural Science Foundation of China(Nos.51873137 and 11705123)the Project of the State Key Laboratory of Radiation Medicine and Protection Soochow University(No.GZN1201801)。
文摘The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillation fiber dosimeter(PSFD)with a current readout mode,systematic studies of the stability and light-dose response were performed for the photomultiplier tube(PMT),silicon photomultiplier(SiPM),avalanche photodiode(APD),and photodiode(PD).The temperature stability,long-term stability,repeatability,signal-to-noise ratio(SNR),and current dose response of the PSFD with the abovementioned photoelectric devices were studied using a pulsed LED light source and the Small Animal Radiation Therapy platform.An exponential relationship between the dark/ne current and temperature was obtained for all the devices.I is shown that the APD is the most sensitive device to temperature,with a current dependence on temperature reaching 6.5%C^(-1)at room temperature,whereas for the other devices this dependence is always<0:6%C^(-1).In terms of long-term stability,the net current of PD can change by up to 4%when working continuously for 8 h and 2%when working intermittently for 32 h,whereas for the other devices,the changes are all<1%.For the dose response,the PMT and SiPM exhibit excellent linear responses and SNRs within the range of 0.1-60 Gy/min For the PSFD with a current readout mode,the performance of the PMT and SiPM is concluded to be better than that of the other devices in the study.In particular,the SiPM,which has a compact size,low bias voltage,and antimagnetic interference,has great advantages for further applications.
文摘In the present work, we designed the new type of photonic crystals (PCs) as reflectors. Reflections from single layer of Al2O3/MgO PC help us in recapturing the light that does escape from the scintillation surface. Photonic crystals in one dimension array of Al2O3 and MgO with silver at periodicities N = 1, 2 and 3 were used as a reflector around the surface of the scintillation volume. Scintillation detectors are widely used in nuclear medicine. The efficiency is an important parameter for characterizing the capability of the detectors. The counting efficiency of the detectors depends on the light emission induced by radiation. The light then was converted by the photomultiplier tube into electrical pulses. The efficiency may increase by an amount of 1.64% if MgO-Ag photonic crystals are used at periodicity N = 1 as a reflector.
基金The project sponsored by the Scientific Research Foundation of Third Institute of Oceanography,Ministry of Natural Resources,under contract No.2020012the Join Project of Xiamen Marine Research and Development Institute under contract No.K191301.
文摘A method of measuring the tritium in seawater based on electrolytic enrichment and ultra-low background liquid scintillation counting techniques was established.The different factors influencing the detection limit were studied,including the counting time,the electrolytic volume of the seawater samples,the selection of background water,scintillation solution and their ratio.After optimizing the parameters and electrolyzing 350 mL volume of samples,the detection limit of the method was as low as 0.10 Bq/L.In order to test the optimization of system for this method,of the 84 seawater samples collected from the Arctic Ocean we measured,92%were above the detection limit(the activity of this samples ranged from 0.10 Bq/L to 1.44 Bq/L with an average of(0.30±0.24)Bq/L).In future research,if we need to accurately measure the tritium activity in samples,the volume of the electrolytic samples will be increased to further reduce the minimum detectable activity.
文摘Formation elements logging is a neutron gamma spectroscopy logging technique used to acquire the content of elements and minerals by recording the gamma ray produced by the reaction of neutron and elemental nucleus in the formation. It has a wide usage in discriminating complex lithology and evaluating unconventional reservoir. The Monte Carlo simulation model of formation elements logging tool is established in this paper, with which the effects of tool parameters including the material and length of the scintillation crystal and source spacing on logging responses are modeled. The results show that the energy response of LaBr_3: Ce crystal is better than others, and the detection efficiency increases with the crystal length but decrease with source spacing. The above results may be used as a reference for optimizing the tool structure design.
基金Supported by the National Natural Science Young Foundation of China(41704168)。
文摘The observations of Global Positioning System(GPS) scintillation,Total Electron Content(TEC)depletion,the periodic structure of TEC and Rate of TEC Index(ROTI) over south China were presented.Data were collected from GPS observations at stations of Shenzhen and Guangzhou from 2011 to 2012.This study reported that the ratio of simultaneous occurrences of TEC depletions with strong scintillations was higher than that of TEC depletions with weak scintillations in vernal and autumnal equinoxes of 2011 over South China.The number of the periodic structures of TEC with depletion contained was greater than that with no depletion contained corresponding to strong scintillations.The structure of the slab of plasma irregularities could be responsible for the simultaneous occurrences of TEC depletion with strong scintillations and ROTI.Before and during the occurrences of strong scintillation,there was Large-Scale Wave Structure(LSWS) which provided the seed ionization perturbation to trigger ESF irregularities and contributed to the periodic structure of TEC.
基金This work was supported by the National Key Research and Development Plan of China(2018YFB0505103)the National Natural Science Foundation of China(61873064)the Science and Technology Project of State Grid Corporation of China(SGSHJX00KXJS1901531).
文摘In the equatorial region,deep amplitude fading in global positioning system(GPS)signals frequently occurs during the strong ionospheric scintillation,it can lead to the loss of lock in GPS carrier tracking loops,and result in increased positioning error and even navigation interruption.The relationships between amplitude scintillation indices and detrended carrier frequency are investigated,based on GPS L1 C/A signals during the last peak of the solar cycle at the low latitude site of São Josédos Campos,Brazil(23.2S,45.9W)from 2013 to 2015.Corresponding mathematic model of the probability distribution function is built for the first time to provide statistical analysis on the above relationships.The results show that the standard carrier frequencies reveal an almost linear relation with the amplitude scintillation indices.Moreover,the frequency widths of detrended frequency are proportional to levels of amplitude scintillation when the value of the peak probability is lower than the corresponding boundary.A conclusion can be drawn that different levels of amplitude scintillation will influence the fluctuation of the carrier frequency.The analysis will provide useful guidance to set the receiver’s bandwidth with respect to the different scintillation levels and design the advanced tracking algorithms to improve the robustness and precision of the GPS receiver.
基金supported by the National Natural Science Foundation of China(No.11305127)the State Key Lab of Intense Pulsed Radiation Simulation and Effect Basic Research Foundation(No.SKLIPR1216)
文摘In this study, a scintillation detector was developed to measure the space proton effective dose for astronauts based on the proton effective dose conversion coefficients provided by International Commission on Radiological Protection Report No. 116. In the Monte Carlo N-Particle Transport Code X(version 2.6.0) simulation process, by modulating the depth and solid angle of truncated conical holes in an iron shell from lower-energy protons to higher-energy protons, the energy deposited in the scintillator by isotropic protons was nearly proportional to the corresponding effective dose, with a maximum relative deviation of 13.28% at thirteen energy points in the energy range of 10–400 MeV. Therefore, the detector can monitor proton effective dose indirectly in real time by measuring the deposited energy. We calibrated the photoelectric conversion efficiency of the detector at the cobalt source, tested the response of the detector in the energy range of 30–100 MeV in unidirectional proton field, and validated the simulation with the experimental results.
基金SupportedbytheNationalNaturalScienceFoundationofChina (No .499840 0 1)
文摘Besides their intended use in radio navigation, global positioning system (GPS) satellite signals provide convenient radio beacons for ionospheric studies. Among other propagation phenomena, the ionosphere affects GPS signal propagation through amplitude scintillations that develop after radio waves propagation through ionospheric electron density irregularities. This paper outlines the design, testing, and results of a specialized GPS receiver to monitor L-band scintillations. The scintillation monitor system consists of a commercial GPS receiver development kit with its software designed to log signal strength and carrier phase from up to 12 channels at one sample per second rate. Other prime features of the monitor include the data compression, transmission and processing. Here is the fact that they are inexpensive and compact and therefore can be readily proliferated.
基金supported by the National Natural Science Foundation of China(Nos.11705103,12005120).
文摘As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources.The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel.GRAND is the largest neutrino detection array to be built in China.GRANDProto35,as the first stage of the GRAND experiment,is a coincidence array composed of radio antennas and a scintillation detector,the latter of which,as a traditional detector,is used to perform cross-validation with radio detection,thus verifying the radio detection efficiency and enabling study of the background exclusion method.This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35.A package based on GEANT4 was used to simulate the details of the scintillation detector,including the optical properties of its materials,the height of the light guide box,and position inhomogeneity.The surface of the scintillator and the reflective materials used in the detector was optimized,and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied.According to the simulation study,the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface,with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m^(2).The performance of the detector was tested in detail through a coincidence experiment,and the test results showed that the number of photoelectrons collected in the detector was$84 with a time resolution of~1 ns,indicating good performance.The simulation results were consistent with those obtained from the tests,which also verified the reliability of the simulation software.These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.
基金project titled Development of Ionospheric TEC Data Assimilation Model based on Kalman Filter using Ground and Space based GNSS and Ionosonde observations, File No. ECR/2015/000410the Department of Science and Technology, New Delhi, India for funding this research through SR/FST/ESI-130/2013(C) FIST program and File No. EMR/2015/000100
文摘The amplitude and phase of L-band satellite signals are fluctuated randomly due to small scale electron density irregularity structures in the ionosphere which result in fleeting variations, known as 'ionospheric scintillations'. The Global Navigation Satellite System(GNSS) is a profound remote sensing tool to monitor, model and forecast the ionospheric weather conditions. In this paper, the GNSS amplitude scintillation data has been analyzed during the year 2013 at Bengaluru(12.9°N, 77.59°E) and Lucknow(26.8467°N, 80.9462°E) stations to reinforce climatology of ionospheric scintillation over Indian low-latitude region. The probability of scintillation occurrence and their variations over equatorial and Equatorial Ionization Anomaly(EIA) regions in India are analyzed during various geomagnetic quiet and disturbed days, months and seasons. The annual occurrence of amplitude scintillations are mapped with the function of local time. It is observed from the experimental results that the probability of scintillations occurrences is higher over EIA region than over the equatorial region. The probability of scintillations is higher during March equinox and December solstice, and lowest during June solstice.Distribution of scintillations is intense during post-sunset period. The maximum percentage of scintillation occurrences at the two stations are recorded in November. Moreover, the highest percentage of scintillation occurrences took place on storm day(March 17, 2013) at the two stations. This work would be helpful for understanding the features of GNSS amplitude scintillations over Southern and Northern Indian regions. Moreover, these kinds of investigations are helpful for developing new algorithms to nowcast and forecast ionospheric scintillations over Indian Sub-continent.
文摘A theoretical formula for measuring the power-law spectrum with interferometer is presented inthis paper for the study of ionosphere.The results of theoretical calculation agree well with themeasurements.The radio scintillation power-law spectrum index which is caused by the irregulanrities in theionosphere is determined to be p=3.5 from the results.
文摘The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete material.To address this problem,an in-situ and nondestructive analysis method was developed to determineγ-ray-emitting nuclides and their specific activities in the concrete walls and floor by using a portable germanium semiconductor detector.In this work,we examined a substitute for Ge detector to establish a simpler and more convenient method.As candidates,we focused on some scintillation type spectrometers,and the possibility of a substitute for a Ge detector was examined by both simulation and experiment.The detection limits were roughly estimated through Monte Carlo simulation for various scintillation crystals,and it was found that 1.5-inch LaBr3,CeBr3,and SrI2 could distinguish the clearance level.It was confirmed that the 1.5-inch LaBr3 could reproduce the calibration curve of the Ge detector in the experiment.The required thickness and length of the radiation shield for suppressing the background radiation during the measurement was also determined for the convenience of an actual decommissioning work.
基金funded by FAPESP(Process 06/04008-2)funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sk?odowska-Curie Actions grant agreement No 722023。
文摘We estimate the zonal drift velocity of small-scale ionospheric irregularities at low latitude by leveraging the spaced-receivers technique applied to two GNSS receivers for scintillation monitoring installed along the magnetic parallel passing in Presidente Prudente(Brazil,magnetic latitude 12.8°S).The investigated ionospheric sector is ideal to study small-scale irregularities,being located close to the expected position of the southern crest of the equatorial ionospheric anomaly.The measurement campaign took place between September 2013 and February 2014,i.e.equinox and summer solstice seasons under solar maximum,during which the probability of formation of small-scale irregularities is expected to maximize.We found that the hourly average of the velocity increases up to 135 m/s right after the local sunset at ionospheric altitudes and then smoothly decreases in the next hours.Such measurements are in agreement with independent estimations of the velocity made by the Incoherent Scatter Radar located at the Jicamarca Radio Observatory(magnetic latitude 0.1°N),by the Boa Vista Ionosonde(magnetic latitude 12.0°N),and by applying a recently-developed empirical regional short-term forecasting model.Additionally,we investigated the relationship with the percentage occurrence of amplitude scintillation;we report that it is exponentially dependent on the zonal velocity of the irregularities that cause it.
基金Supported by the National Natural Science Foundation of China under Grant No.59932002.
文摘Emission spectra,longitudinal transmission and light output for the Sb-doped and Y-doped PbWO_(4) crystals are presented.Scintillation decay kinetics has been measured by using gate integration and single photon counting method with blue and green filters.Radiation hardness has also been measured by using ^(60)Coγ-ray irradiation under different dose rates and different dose rate profiles.The light yield and radiation hardness of the Sb-doped and Y-doped PbWO_(4) crystals are improved as compared to the undoped crystals and are suitable for the requirements of compact muon solenoid.
基金supported by the fund from Xi’an Institute of Optics and Precision Mechanics。
文摘With the rapid demand for underwater optical communication(UOC), studies of UOC degradation by oceanic turbulence have attached increasing attention worldwide and become a research hot-spot in recent years. Previous studies used a simplified and inaccurate oceanic turbulence spectrum, in which the eddy diffusivity ratio between temperature and salinity is assumed to be unity and the outer scale of turbulence is assumed to be infinite. However, both assumptions are not true in most of the actual marine environments. In this paper, based on the Rytov theory in weak turbulence, we derive analytical expressions of "the aperture-averaged scintillation index"(SI) for both plane and spherical waves, which can clearly demonstrate how SI is influenced by several key factors in UOC. Then, typical fade statistics of the UOC system in weak turbulence is discussed including the probability of fade, the expected number of fades per time, the mean fade time,signal-to-noise ratio and bit error rate. Our results show that spherical wave is preferable in the UOC system in weak turbulence compared to plane wave, and the aperture-averaged effect has a significant impact on UOC system's performance.Our results can be used to determine those key parameters for designing the UOC system over reasonable ranges.
基金the support from National Natural Science Foundation of China(42020104002)。
文摘The 2 nd Equatorial Plasma Bubble(EPB)workshop,funded by the Institute of Geology and Geophysics,Chinese Academy of Sciences,and the National Natural Science Foundation of China,took place in Beijing,China during September 13–15,2019.The EPB workshop belongs to a conference series that began in 2016 in Nagoya,Japan at the Institute for Space-Earth Environmental Research,Nagoya University,resulting in a special issue of Progress in Earth and Planetary Science that focused on EPBs.The main goal of the series is to organize in-depth discussion by scientists working on ionospheric irregularities,and solve the scientific challenges in EPB and ionospheric scintillation forecasting.The 2 nd EPB workshop gathered almost 60 scientists from seven countries.A total of 20 invited and contributing papers focusing on ionospheric irregularities and scintillations were presented.Here we briefly comment on 10 papers included in this special issue.
文摘Based on the theory of optical scintillation induced by fluctuation of particulate concentration, a Gas Flow Velocity Measurement System (GFVMS) is proposed to measure the gas flow velocity in stack. Verification experiments on simulation flue indicate that, for the smoothing effect of transmitting and receiving apertures, optical scintillation induced by refractive index fluctuation is very weak. When particles are added into gas flow, the standard deviation of optical scintillation increased obviously. And when the particulate number concentration exceeds 4000/m3, the GFVMS can work normally, and the variation range of measured velocities is almost the same with that of Pitot tube. Sensitivity testing results show that, GFVMS is very sensitive to velocity change. Results of outfield experiment prove that, velocities measured by GFVMS are more stable and the average velocity (7.62/s) is very close to the statistical average (7.61 m/s) of velocities measured by Pitot tube at different points along optical path.
文摘Throughout the United States, laboratories use different sampling methods (“Direct Fill” vs. “Submerged Bottle” methods), sample preparations (“Simultaneous Drawing” vs. “Separate Drawing”), scintillators (“Mineral Oil” vs. “Opti-Fluor”), volume of water plus scintillator in the cocktail (“8 mL plus 8 mL” vs. “10 mL plus 10 mL”), and liquid scintillation counting assays (“Full Spectrum: 0 - 2000 keV” vs. “Region of Interest: 130 - 700 keV”) for analyzing radon (222Rn) in water. We compared these and few other variables on the recovery of radon from two “Proficiency Test (PT)” samples and four “Household Well Water” samples from Georgia. The “130 - 700 keV” assay had significantly higher radon recovery than the “0 - 2000 keV” assay. The “Direct Fill” sampling produced significantly lower radon recovery than the “Submerged Bottle” sampling. “Simultaneous Drawing” of both scintillator and water sample yielded higher radon recovery than “Separate Drawing”. Air bubble in the samples resulted in significant loss of radon gas;and such loss became greater as the air bubble was larger. A “10 mL scintillator + 10 sample” combination appeared better than “8 mL scintillator + 8 mL sample”. Mixing scintillator and sample in the laboratory, when compared with doing it on-site, was found superior for better results and practicality of testing radon in private well waters. “Mineral Oil” scintillator provided higher radon activity than “Opti-Fluor”. However, in 10 consecutive measurements of the two proficiency test (PT) samples at 60 days interval (i.e., with full ingrowing), “Mineral Oil” overestimated the radon activity compared to the predicted/assigned value in most cases, whereas “Opti-Fluor” invariably produced results close to the predicted/assigned value. There were noticeable temporal variations in both radon and uranium concentrations in the study wells;nevertheless, uranium and radon concentrations had good positive correlation. Despite this, the use of uranium concentration over 30 ppb (the MCL of uranium in drinking water) as a trigger for recommending test for radon in well water remains questionable because there may be the safe level of uranium but unsafe level of radon in a well and vice versa.
文摘The present work examines the validity of using barium as a carrier for radium-226 determination and optimizes the amount added during the radiochemical separation from rock samples. The activity concentration of Ra-226 is determined in rock samples by liquid scintillation spectrometer via its short-lived daughters after the radiochemical separation. The activity of Ra-226 was calculated based on the counts measured in a window set for Po-214 peak. The activity measured by Liquid Scintillation Counter, LSC using Pulse Shape Analysis, PSA. Ba-133 was used for chemical yield. The applied method was tested using a Certified Reference Material, CRM ore number-Dl-1a which shows a good agreement with the certified values. The applied method for measuring Ra-226 has been adapted to be used in rocks such as monazite. The average activity for Ra-226 in rock samples collected from the commercial grade Egyptian monazite was 13.85 ± 2.05 Bq/g with a detection limit 9.58 mBq/g. The optimum conditions have been established during the present work such as precision, cost and time preparation which makes the method useful for radio chemists and the decision makers.