BACKGROUND Peritoneal dialysis(PD)is an important renal replacement therapy in patients with end-stage renal disease.PD catheters remain the lifeline for patients undergoing PD.The catheter technique survival rate is ...BACKGROUND Peritoneal dialysis(PD)is an important renal replacement therapy in patients with end-stage renal disease.PD catheters remain the lifeline for patients undergoing PD.The catheter technique survival rate is considered a core PD outcome domain.CASE SUMMARY The PD catheter spontaneously dislodged in a patient undergoing PD during regular fluid exchange without pain.Abdominal computed tomography showed a tunnel infection.A double-cuff straight Tenckhoff catheter had been inserted using the Seldinger technique.Before this incident,the patient had a history of tunnel infections.We speculate that recurrent tunnel infections and catheter insertion using the Seldinger technique may have led to catheter dislodgement.CONCLUSION The present case suggests that clinicians should more rigorously assess the persistence of catheter-related infections concerning the potential complications arising from catheter dislodgement associated with the Seldinger technique.展开更多
Strand-ed turtles need fluid parenterally. The jugular access is best for the maintenance and patency of the catheter. The Seldinger technique guided by ultrasound seems to be the safest for catheter insertion. Five j...Strand-ed turtles need fluid parenterally. The jugular access is best for the maintenance and patency of the catheter. The Seldinger technique guided by ultrasound seems to be the safest for catheter insertion. Five juveniles Chelonia mydas with fibropapillomatosis and an adult male leatherback turtle (Dermochelys coriacea) with altered buoyancy were sent to Santos Municipal Aquarium for rehabilitation. Turtles underwent catheterization of the jugular vein using the Seldinger technique with central venous polyurethane catheter monolumen 14 G to Dermochelys and 18 G for Chelonia, guided by ultrasound with 10 MHz transducer catheters were sutured to the skin and animals were subjected to fluid. In all turtles, the catheters were patency and were well established. There were no granulomatous reactions or related infections. The Dermochelys improved clinically after fluid resuscitation, and the catheter was removed one week after. In one Chelonia excision was 21% of its weight in tumors, and the animals received colloid catheter by enabling the mitigation of bleeding due to removal. The use of ultrasonography has enabled monitoring of all access as the patency of the catheter and fluid diffusivity.展开更多
AIM To comparatively evaluate Seldinger and Trocar techniques in the percutaneous treatment of hydatid disease. METHODS Trocar and Seldinger techniques were used for 49 and 56 cysts, respectively, among 106 hydatid cy...AIM To comparatively evaluate Seldinger and Trocar techniques in the percutaneous treatment of hydatid disease. METHODS Trocar and Seldinger techniques were used for 49 and 56 cysts, respectively, among 106 hydatid cysts in 88 patients. The number of males and females were 22 and 66, respectively with a mean age of 44.9 years(range, 15-87). Follow-up studies included cyst diameter, cyst contents, and morphological changes inthe cyst wall, local recurrence, and secondary invasion, using ultrasound, computerized tomography and chest X-rays. RESULTS The positive criteria of healing were a decrease in cyst diameter, progressive solidification of the cyst contents, and disappearance of the cyst. Local recurrence was defined as an increase in the cyst diameter and contents, and appearance of daughter cysts in the primary cavity, while secondary dissemination was defined as the appearance of new cysts outside the treated cyst. Mean duration of follow-up was 19.23 mo(range, 18-26 mo). Follow-up results demonstrated that no significant differences were present between the Trocar and Seldinger techniques in the percentage of decrease in the cyst volume, rate of early complications, local recurrence and secondary dissemination(P = 0.384, 0.069, 0.215 and 0.533, respectively). CONCLUSION There are no differences between the Seldinger and Trocar techniques that gain entry to the cyst cavity in terms of the efficacy of the treatment and the rates of early and late complications.展开更多
文摘BACKGROUND Peritoneal dialysis(PD)is an important renal replacement therapy in patients with end-stage renal disease.PD catheters remain the lifeline for patients undergoing PD.The catheter technique survival rate is considered a core PD outcome domain.CASE SUMMARY The PD catheter spontaneously dislodged in a patient undergoing PD during regular fluid exchange without pain.Abdominal computed tomography showed a tunnel infection.A double-cuff straight Tenckhoff catheter had been inserted using the Seldinger technique.Before this incident,the patient had a history of tunnel infections.We speculate that recurrent tunnel infections and catheter insertion using the Seldinger technique may have led to catheter dislodgement.CONCLUSION The present case suggests that clinicians should more rigorously assess the persistence of catheter-related infections concerning the potential complications arising from catheter dislodgement associated with the Seldinger technique.
文摘Strand-ed turtles need fluid parenterally. The jugular access is best for the maintenance and patency of the catheter. The Seldinger technique guided by ultrasound seems to be the safest for catheter insertion. Five juveniles Chelonia mydas with fibropapillomatosis and an adult male leatherback turtle (Dermochelys coriacea) with altered buoyancy were sent to Santos Municipal Aquarium for rehabilitation. Turtles underwent catheterization of the jugular vein using the Seldinger technique with central venous polyurethane catheter monolumen 14 G to Dermochelys and 18 G for Chelonia, guided by ultrasound with 10 MHz transducer catheters were sutured to the skin and animals were subjected to fluid. In all turtles, the catheters were patency and were well established. There were no granulomatous reactions or related infections. The Dermochelys improved clinically after fluid resuscitation, and the catheter was removed one week after. In one Chelonia excision was 21% of its weight in tumors, and the animals received colloid catheter by enabling the mitigation of bleeding due to removal. The use of ultrasonography has enabled monitoring of all access as the patency of the catheter and fluid diffusivity.
文摘AIM To comparatively evaluate Seldinger and Trocar techniques in the percutaneous treatment of hydatid disease. METHODS Trocar and Seldinger techniques were used for 49 and 56 cysts, respectively, among 106 hydatid cysts in 88 patients. The number of males and females were 22 and 66, respectively with a mean age of 44.9 years(range, 15-87). Follow-up studies included cyst diameter, cyst contents, and morphological changes inthe cyst wall, local recurrence, and secondary invasion, using ultrasound, computerized tomography and chest X-rays. RESULTS The positive criteria of healing were a decrease in cyst diameter, progressive solidification of the cyst contents, and disappearance of the cyst. Local recurrence was defined as an increase in the cyst diameter and contents, and appearance of daughter cysts in the primary cavity, while secondary dissemination was defined as the appearance of new cysts outside the treated cyst. Mean duration of follow-up was 19.23 mo(range, 18-26 mo). Follow-up results demonstrated that no significant differences were present between the Trocar and Seldinger techniques in the percentage of decrease in the cyst volume, rate of early complications, local recurrence and secondary dissemination(P = 0.384, 0.069, 0.215 and 0.533, respectively). CONCLUSION There are no differences between the Seldinger and Trocar techniques that gain entry to the cyst cavity in terms of the efficacy of the treatment and the rates of early and late complications.