期刊文献+
共找到85,336篇文章
< 1 2 250 >
每页显示 20 50 100
Sinus Lift versus Short Implants: Results of a Prospective Radiologic Study and Critical Review of Minimally Invasive Transcrestal Sinus Lift Procedures
1
作者 Izabela Schlichting Dagmar Lacina Bianca Fischak-Treitl 《Open Journal of Stomatology》 2017年第1期1-24,共24页
Introduction: The current discussion about the use of short implants to avoid bone-augmentation (“sinus lift”) in the lateral maxilla remains a controversial topic and is increasingly at odds with the reality of evo... Introduction: The current discussion about the use of short implants to avoid bone-augmentation (“sinus lift”) in the lateral maxilla remains a controversial topic and is increasingly at odds with the reality of evolutionary biology. Aim of the study was to determine the percentage of cases from a large routine patient-sample in which short implants might be suitable to avoid sinus lift procedures. Materials and Methods: From January 2012 to June 2015, all patients in three general dental practices in Austria with at least one subantral edentulous area were subjected to routine panoramic X-ray screening. The subantral alveolar ridge heights and the mesial extension of the maxillary sinus towards the canine fossa were measured. Statistics were performed by Excel data analysis (mean value, standard deviation). Results: 2837 patients were screened with 2837 panoramic radiographs presenting 3528 edentulous subantral regions and the subantral bone heights of 5674 maxillary sinuses were surveyed. 57.43% revealed subantral alveolar ridge heights of 4 mm or less;24.43% of all measure-points indicated a maximum alveolar ridge height of 6 mm. In 39.32% of cases, the pneumatisation of the maxillary sinuses with a subantral residual ridge height of 6 mm or less extended as far as the anatomical position of the second premolars, in 20.51% as far as the position of the first premolar and in 10.84% as far as the canine fossa. Discussion: The sinus lift procedure will continue to be one of the basic standard surgical procedures carried out by practice-based dental surgeons who perform implant surgery since in at least two thirds of the cases short implants with lengths of less than 6 mm cannot be applied. Preference should be given to sinus lift-procedures, which can be learned safely with a minimum of time-effort, least risk of failure and lowest possible level of patient morbidity. Transcrestal hydrodynamic ultrasonic sinus lift-procedures with piezotomes seem to fulfill these basic demands. 展开更多
关键词 Oral SURGERY implantOLOGY SINUS LIFT Piezotome SURGERY Ultrasonic SURGERY short implants
下载PDF
Stress Distributions Created by Short and Regular Implants Placed in the Anterior Maxilla at Different Angles: A Finite Element Analysis
2
作者 Mehmet Fatih Özmen Funda Bayındır 《Open Journal of Stomatology》 2023年第1期32-49,共18页
Although short implants are seen as alternative treatments that require additional surgical techniques in posterior region, they can be applied to anterior maxilla and various studies are required on this subject. The... Although short implants are seen as alternative treatments that require additional surgical techniques in posterior region, they can be applied to anterior maxilla and various studies are required on this subject. The purpose of this study was to examine and compare the peak von Mises stress distributions in the crown, implant and abutment by using finite element analysis (FEA). Besides, a comparison of the implant-abutment connection types in the short implant with the FEA method was established. A short implant (4 × 5 mm) with a taper-lock connection and a regular implant (4 × 9 mm) with a screw connection were used in maxillary central incisor tooth area. Three different titanium abutments with 0?, 15? and 25? angles were used for abutments. In addition, in order to determine whether the stress change in short implants is due to the length of the implant-abutment connection, a screw was designed for a short implant and it was also evaluated in the same three angles. A total of three groups and nine models were generated. 114.6N load was applied to the cingulum area of the crown at an angle of 135? to the long axis of the crowns. A torque load of 25 Ncm was applied to the regular and short implant screw. Von Mises stress distributions of implants, abutments and crowns were evaluated by using FEA. Increased angle in implants increased von Mises stress values of implant, abutment and crown. Screw connection was found higher at all angles in short implants. Close values were found at different angles in taper-lock short implant crowns. The length and the angle in the bone of implant with the type of implant-abutment connection results in the accumulated stress values. Clinical Implications Taper implant-abutment connection system was found to be more promising in terms of stress accumulation in crowns. Although the amount of stress on the abutment increased due to the length of the implant in short implants, taper implant-abutment connection system slightly reduced related to this increase. 展开更多
关键词 Anterior Maxilla Finite Element Analysis Von Mises short implant
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
3
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer Capsular Contracture Expander implantation
下载PDF
Burden of routine orthopedic implant removal a single center retrospective study
4
作者 Ammar K AlOmran Nader Alosaimi +6 位作者 Ahmed A Alshaikhi Omar M Bakhurji Khalid J Alzahrani Basil Ziyad Salloot Tamim Omar Alabduladhem Ahmed I AlMulhim Arwa Alumran 《World Journal of Orthopedics》 2024年第2期139-146,共8页
BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramou... BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramount for orthopedic surgeons.This study aims to quantify the impact of routine implant removal on patients and healthcare facilities.A retrospective analysis of implant removal cases from 2016 to 2022 at King Fahad Hospital of the University(KFHU)was conducted and subjected to statistical scrutiny.Among these cases,44%necessitated hospitalization exceeding one day,while 56%required only a single day.Adults exhibited a 55%need for extended hospital stays,contrasting with 22.8%among the pediatric cohort.The complication rate was 6%,with all patients experiencing at least one complication.Notably,34.1%required sick leave and 4.8%exceeded 14 d.General anesthesia was predominant(88%).Routine implant removal introduces unwarranted complications,particularly in adults,potentially prolonging hospitalization.This procedure strains hospital resources,tying up the operating room that could otherwise accommodate critical surgeries.Clearly defined institutional guidelines are imperative to regulate this practice.AIM To measure the burden of routine implant removal on the patients and hospital.METHODS This is a retrospective analysis study of 167 routine implant removal cases treated at KFHU,a tertiary hospital in Saudi Arabia.Data were collected in the orthopedic department at KFHU from February 2016 to August 2022,which includes routine asymptomatic implant removal cases across all age categories.Nonroutine indications such as infection,pain,implant failure,malunion,nonunion,restricted range of motion,and prominent hardware were excluded.Patients who had external fixators removed or joints replaced were also excluded.RESULTS Between February 2016 and August 2022,360 implants were retrieved;however,only 167 of those who met the inclusion criteria were included in this study.The remaining implants were rejected due to exclusion criteria.Among the cases,44%required more than one day in the hospital,whereas 56%required only one day.55%of adults required more than one day of hospitalization,while 22.8%of pediatric patients required more than one day of inpatient care.The complication rate was 6%,with each patient experiencing at least one complication.Sick leave was required in 34.1%of cases,with 4.8%requiring more than 14 d.The most common type of anesthesia used in the surgeries was general anesthesia(88%),and the mean(SD)surgery duration was 77.1(54.7)min.CONCLUSION Routine implant removal causes unnecessary complications,prolongs hospital stays,depletes resources and monopolizing operating rooms that could serve more critical procedures. 展开更多
关键词 implant removal Healed fracture Orthopedic implant COMPLICATIONS Healthcare system
下载PDF
Improving the Surface Roughness of Dental Implant Fixture by Considering the Size,Angle and Spraying Pressure of Sandblast Particles
5
作者 Ehsan Anbarzadeh Bijan Mohammadi 《Journal of Bionic Engineering》 SCIE EI CSCD 2024年第1期303-324,共22页
In this study,different conditions of sandblasting on dental implant fixtures were investigated to achieve the best sandblasting conditions.18 different sandblasting conditions(Using 152 implant fixture samples)were e... In this study,different conditions of sandblasting on dental implant fixtures were investigated to achieve the best sandblasting conditions.18 different sandblasting conditions(Using 152 implant fixture samples)were examined,including parameters such as particle size,particle blasting pressure,and particle blasting angle.The surface treatment of the samples was performed using the SLA+Anodizing method.AFM testing was performed for each of the 18 different states,and the average surface roughness of each of these was compared with each other.Then,a bone layer was placed on the sample with the closest average surface roughness to the standard and the least amount of aluminum oxide on its surface among the 18 different states,to confirm the accuracy and quality of the desired surface roughness by examining the bone formation process and speed.The results showed that state No.4(sandblast particle size:75µm,spraying pressure of sandblast particles:4 bar,sandblast particle spraying angle:30 degrees),which was prepared using the SLA+Anodizing method and had a surface roughness of 1.989µm(The percentage of Al_(2)O_(3)on the surface=6%),had the best sandblasting conditions and showed 95%cell viability and accelerated the treatment and bone formation process for about a week.The simulation results,using Abaqus software,indicated that the stress distribution on the surface of the implant fixture in contact with the bone surface has increased by approximately 4.3%for state No.4.This will help prevent loosening of the dental implant fixture over time. 展开更多
关键词 Dental implants Surface treatment Sandblast Surface roughness OSSEOINTEGRATION
下载PDF
Graphene-calcium carbonate coating to improve the degradation resistance and mechanical integrity of a biodegradable implant
6
作者 Lokesh Choudhary Parama Chakraborty Banerjee +5 位作者 R.K.Singh Raman Derrek E.Lobo Christopher D.Easton Mainak Majumder Frank Witte Jörg F.Löffler 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期394-404,共11页
Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve ... Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve the corrosion resistance of these implants without compromising their mechanical integrity.In this study,an AZ91 magnesium alloy,as a representative for a biodegradable Mg implant material,was modified with a thin reduced graphene oxide(RGO)-calcium carbonate(CaCO_(3))composite coating.Detailed analytical and in-vitro electrochemical characterization reveals that this coating significantly improves the corrosion resistance and mechanical integrity,and thus has the potential to greatly extend the related application field. 展开更多
关键词 Graphene coating Biodegradable implant HYDROXYAPATITE Corrosion Magnesium alloy
下载PDF
Peri-implant gas accumulation in response to magnesium-based musculoskeletal biomaterials:Reframing current evidence for preclinical research and clinical evaluation
7
作者 Yu Sun Heike Helmholz Regine Willumeit-Römer 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期59-71,共13页
Historically,the rapid degradation and massive gas release from magnesium(Mg)implants resulted in severe emphysema and mechanical failure.With the advent of new alloys and surface treatment methods,optimized Mg implan... Historically,the rapid degradation and massive gas release from magnesium(Mg)implants resulted in severe emphysema and mechanical failure.With the advent of new alloys and surface treatment methods,optimized Mg implants have re-entered clinics since last decade with reliable performance.However,the optimization aims at slowing down the degradation process,rather than exemption of the gas release.This study involved a systematic evaluation of current preclinical and clinical evidence,regarding the physical signs,symptoms,radiological features,pathological findings and complications potentially associated with peri±implant gas accumulation(PIGA)after musculoskeletal Mg implantation.The literature search identified 196 potentially relevant publications,and 51 papers were enrolled for further analysis,including 22 preclinical tests and 29 clinical studies published from 2005 to 2023.Various Mg-based materials have been evaluated in animal research,and the application of pure Mg and Mg alloys have been reported in clinical follow-ups involving multiple anatomical sites and musculoskeletal disorders.Soft tissue and intraosseous PIGA are common in both animal tests and clinical follow-ups,and potentially associated with certain adverse events.Radiological examinations especially micro-CT and clinical CT scans provide valuable information for quantitative and longitudinal analysis.While according to simulation tests involving Mg implantation and chemical processing,tissue fixation could lead to an increase in the volume of gas cavity,thus the results obtained from ex vivo imaging or histopathological evaluations should be interpreted with caution.There still lacks standardized procedures or consensus for both preclinical and clinical evaluation of PIGA.However,by providing focused insights into the topic,this evidence-based study will facilitate future animal tests and clinical evaluations,and support developing biocompatible Mg implants for the treatment of musculoskeletal disorders. 展开更多
关键词 Magnesium implant Degradation Hydrogen Gas release Postoperative follow-up
下载PDF
HVOF-sprayed HAp/S53P4 BG composite coatings on an AZ31 alloy for potential applications in temporary implants
8
作者 Carlos A.Poblano-Salas John Henao +6 位作者 Astrid L.Giraldo-Betancur Paola Forero-Sossa Diego German Espinosa-Arbelaez Jorge A.González-Sánchez Luis R.Dzib-Pérez Susana T.Estrada-Moo Idelfonso E.Pech-Pech 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期345-360,共16页
Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HA... Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HAp and BG to dissolve and promote osseointegration,considering that both phases have different reaction and dissolution rates under in-vitro conditions.In the present work,75%wt.HAp-25%wt.S53P4 bioactive glass powders were HVOF-sprayed to obtain HAp/S53P4 BG composite coatings on a bioresorbable AZ31 alloy.The study is focused on exploring the effect of the stand-off distance and fuel/oxygen ratio variation as HVOF parameters to obtain stable structural coatings and to establish their effect on the phases and microstructure produced in those coatings.Different characterization techniques,such as scanning electron microscopy,X-ray diffraction,and Fourier transform infrared spectroscopy,were employed to characterize relevant structural and microstructural properties of the composite coatings.The results showed that thermal gradients during coating deposition must be managed to avoid delamination due to the high temperature achieved(max 550℃)and the differences in coefficients of thermal expansion.It was also found that both spraying distance and oxygen/fuel ratio allowed to keep the hydroxyapatite as the main phase in the coatings.In addition,in-vitro electrochemical studies were performed on the obtained HAp/S53P4 BG composite coatings and compared against the uncoated AZ31 alloy.The results showed a significant decrease in hydrogen evolution(at least 98%)when the bioactive coating was applied on the Mg alloy during evaluation in simulated body fluid(SBF). 展开更多
关键词 Coatings Composites Thermal spray Temporary implants Hydrogen evolution
下载PDF
Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information
9
作者 Jin Zhou Shenghan Zhou +4 位作者 Peidi Fan Xunjia Li Yibin Ying Jianfeng Ping Yuxiang Pan 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期183-211,共29页
In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,... In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,implantable electrochemical microsensors have emerged as a prominent area of research.These microsensors not only fulfill the technical requirements for monitoring animal physiological information but also offer an ideal platform for integration.They have been extensively studied for their ability to monitor animal physiological information in a minimally invasive manner,characterized by their bloodless,painless features,and exceptional performance.The development of implantable electrochemical microsensors for in vivo monitoring of animal physiological information has witnessed significant scientific and technological advancements through dedicated efforts.This review commenced with a comprehensive discussion of the construction of microsensors,including the materials utilized and the methods employed for fabrication.Following this,we proceeded to explore the various implantation technologies employed for electrochemical microsensors.In addition,a comprehensive overview was provided of the various applications of implantable electrochemical microsensors,specifically in the monitoring of diseases and the investigation of disease mechanisms.Lastly,a concise conclusion was conducted on the recent advancements and significant obstacles pertaining to the practical implementation of implantable electrochemical microsensors. 展开更多
关键词 Electrochemical microsensors implantable sensors In vivo monitoring Animal physiological information
下载PDF
A Novel Method for Forecasting Freak Wave Occurrence in A Short Crested Coastal Sea
10
作者 WANG Ying-guang 《China Ocean Engineering》 SCIE EI CSCD 2024年第1期104-116,共13页
In order to forecast the distribution of crest amplitudes and the occurrence of freak waves in a short crested coastal sea,a novel transformed linear simulation method is initially proposed in this paper.A Hermite tra... In order to forecast the distribution of crest amplitudes and the occurrence of freak waves in a short crested coastal sea,a novel transformed linear simulation method is initially proposed in this paper.A Hermite transformation model expressed as a monotonic cubic polynomial serves as the foundation for the novel simulation technique.The wave crest amplitude exceedance probabilities of two sea states-one with a directional wave spectrum based on the measured wave elevation data at the Yura coast and the other with a typical directional JONSWAP wave spectrum-have been predicted using the novel simulation method that has been proposed.The likelihood that a particular critical wave crest amplitude will be exceeded is directly correlated with the probability that freak waves will occur.It is shown that the novel simulation approach suggested can provide predictions that are more precise than those obtained from the Rayleigh crest amplitude distribution model,the Jahns and Wheeler crest amplitude distribution model,or the conventional linear simulation method.This study also demonstrated that the nonlinear simulation method is less effective than the novel simulation method in terms of efficiency. 展开更多
关键词 wave crest amplitude freak waves short crested sea transformed linear simulation
下载PDF
Baerveldt glaucoma implant with Supramid© ripcord stent in neovascular glaucoma: a case series
11
作者 Yuen Keat Gan Shiivaa Manjare Birapadian +1 位作者 Muhammad Irfan Abdul Jalal Norshamsiah Md Din 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期265-271,共7页
AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripco... AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripcord stent in patients with NVG.No tube ligation or venting slits were performed.Supramid was removed after 3mo if the target intraocular pressure(IOP)was not achieved.Surgical success was defined as IOP≤21 mm Hg with(qualified success)or without IOP-lowering medications(complete success).RESULTS:Twenty-six eyes from 24 patients were included in the study.The median duration of follow-up was 4[interquartile range(IQR)=1-5]y,ranging from 0.5 to 5y.IOP decreased by a mean of 24.2 mm Hg(59.7%);from a mean of 40.5±12.6 mm Hg at baseline to 16.3±11.9 mm Hg,P≤0.001.The number of glaucoma medications reduced from a median of 5(IQR=5-6)to 1(IQR=0-2,P≤0.001)at the final follow-up.Overall success rates were 88.0%at 1y,34.8%at 3y,66.7%at 4y,and 50%at 5y.Hypertensive phase(HP)in the first 3mo occurred in 15/26 eyes(57.7%)with a mean IOP of 31.1 mm Hg.CONCLUSION:BGI with Supramid©ripcord stent gives close to 90%of the overall survival rate at the final follow-up without significant early hypotony.However,early HP is still a challenge. 展开更多
关键词 neovascular glaucoma Supramid ripcord stent Baerveldt glaucoma implant
原文传递
Advances in Wireless,Batteryless,Implantable Electronics for Real‑Time,Continuous Physiological Monitoring
12
作者 Hyeonseok Kim Bruno Rigo +2 位作者 Gabriella Wong Yoon Jae Lee Woon‑Hong Yeo 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期254-302,共49页
This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design co... This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design considerations,such as biological constraints,energy sourcing,and wireless communication,are discussed in achieving the desired performance of the devices and enhanced interface with human tissues.In addition,we review the recent achievements in materials used for developing implantable systems,emphasizing their importance in achieving multi-functionalities,biocompatibility,and hemocompatibility.The wireless,batteryless devices offer minimally invasive device insertion to the body,enabling portable health monitoring and advanced disease diagnosis.Lastly,we summarize the most recent practical applications of advanced implantable devices for human health care,highlighting their potential for immediate commercialization and clinical uses. 展开更多
关键词 implantable electronics Biomedical systems Batteryless devices Wireless electronics Physiological signal monitoring
下载PDF
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
13
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
原文传递
Glaucoma drainage device implantation and cyclophotocoagulation in the management of refractory glaucoma after Descemet-stripping automated endothelial keratoplasty
14
作者 Min-Shu Wang Xue-Chuan Dong +4 位作者 Mi-Yun Zheng Xiang Fan Ge-Ge Xiao Jing Hong Ling-Ling Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期257-264,共8页
AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated en... AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated endothelial keratoplasty(DSAEK).METHODS:This retrospective study on observational case series enrolled 29 patients who underwent DSAEK and posterior anti-glaucoma surgery(15 with GDI and 14 with CPC).The main outcome measures were intraocular pressure(IOP),glaucoma surgery success rate(defined as IOP of 6–21 mm Hg without additional anti-glaucoma operation),number of glaucoma medications,endothelial graft status,and best-corrected visual acuity(BCVA).RESULTS:The mean follow-up time was 34.1 and 21.0mo for DSAEK or glaucoma surgeries,both for the GDI and CPC groups.Both groups showed significant IOP reduction after glaucoma surgery.The GDI group presented a significantly higher success rate in IOP control than the CPC group(60%vs 21.4%,P=0.03).Both procedures significantly decreased the number of glaucoma medications(P=0.03).Forty percent and 57%of cases in the GDI and the CPC group,respectively,experienced endothelial graft failure during follow-up(P=0.36).Significantly worse BCVA after surgery was observed in the CPC group but not in the GDI group.CONCLUSION:Both GDI and CPC significantly decrease IOP in eyes with glaucoma after DSAEK.GDI is preferable to CPC in refractory glaucoma cases after DSAEK,as it manifests a significantly higher success rate for IOP control,similar endothelial graft failure rate,and relatively preserves BCVA than CPC. 展开更多
关键词 glaucoma drainage device implantation CYCLOPHOTOCOAGULATION refractory glaucoma Descemetstripping automated endothelial keratoplasty
原文传递
Effectiveness of Short Message Service Support on Adherence to Chemotherapy Treatment among Patients Attending Cancer Treatment Facilities in Kenya
15
作者 Nebert Kiguhe Mchidi John P. Oyore Gordon Ogweno 《Open Journal of Nursing》 2024年第3期93-113,共21页
Introduction: Cancer is a chronic debilitating disease that unnerves patients, communities, and nations. At some point in cancer patient’s disease experience, chemotherapy is used, and the patient is expected to adhe... Introduction: Cancer is a chronic debilitating disease that unnerves patients, communities, and nations. At some point in cancer patient’s disease experience, chemotherapy is used, and the patient is expected to adhere to treatment to improve survival and quality of life. Methods: This multisite Cluster Randomized Trial (CRT) evaluated the effectiveness of mobile phone Short Message Service (SMS) support on the adherence to treatment schedules among adult cancer patients in Kenya. Data was collected using questionnaires. Ethical approvals were obtained from relevant Ethical Review Boards (ERBs). Results: The mean adherence was 83%. There was a significant difference between treatment arms in relation to the adherence. The intervention arm had a higher mean adherence difference, M = 3.913, 95% CI 2.632-5.193, t (402) = 6.006, p ≤ 0.001), with Cohen’s d = 0.60. Although not significant, (χ<sup>2</sup>dd = 0.151, df = 1, p = 2.064), more women were perfect adheres than males. Perfect adherers were satisfied with SMS support (χ<sup>2</sup>dd = 7.620, df = 1, p = 0.06), were in the intervention arm (χ<sup>2</sup>dd = 22.942, df = 1, p ≤ 0.001), and had trust in the care provider (χ<sup>2</sup>dd = 10.591 p ≤ 0.001). SMS support was not significant in the multivariate analysis but had an estimated effect size of 0.958 (z = 1.424, p = 0.154, CI = 0.242-3.781), indicating that mean adherence was slightly better in the presence of the intervention. Conclusions: SMS-support intervention has demonstrated superiority in influencing adherence. Further, health system-related factors have a significant influence on the adherence to chemotherapy treatment. Interventions to re-design health systems that are responsive to unmet care needs of cancer patients must be explored. . 展开更多
关键词 ADHERENCE Cancer Symptom Distress Quality of Life Medication Posses-sion Ratio short Message Service SURVIVORSHIP
下载PDF
Embryo Transfer Strategies for Women with Recurrent Implantation Failure During the Frozen-thawed Embryo Transfer Cycles:Sequential Embryo Transfer or Double-blastocyst Transfer?
16
作者 Qiao-hang ZHAO Yu-wei SONG +8 位作者 Jian CHEN Xiang ZHOU Ji-lai XIE Qiu-ping YAO Qi-yin DONG Chun FENG Li-ming ZHOU Wei-ping FU Min JIN 《Current Medical Science》 SCIE CAS 2024年第1期212-222,共11页
Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of Se... Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of SeET and DBT on pregnancy outcomes.Methods Totally,261 frozen-thawed embryo transfer cycles of 243 RIF women were included in this multicenter retrospective analysis.According to different embryo quality and transfer strategies,they were divided into four groups:group A,good-quality SeET(GQ-SeET,n=38 cycles);group B,poor-quality or mixed-quality SeET(PQ/MQ-SeET,n=31 cycles);group C,good-quality DBT(GQ-DBT,n=121 cycles);and group D,poor-quality or mixed-quality DBT(PQ/MQ-DBT,n=71 cycles).The main outcome,clinical pregnancy rate,was compared,and the generalized estimating equation(GEE)model was used to correct potential confounders that might impact pregnancy outcomes.Results GQ-DBT achieved a significantly higher clinical pregnancy rate(aOR 2.588,95%CI 1.267–5.284,P=0.009)and live birth rate(aOR 3.082,95%CI 1.482–6.412,P=0.003)than PQ/MQ-DBT.Similarly,the clinical pregnancy rate was significantly higher in GQ-SeET than in PQ/MQ-SeET(aOR 4.047,95%CI 1.218–13.450,P=0.023).The pregnancy outcomes of GQ-SeET were not significantly different from those of GQ-DBT,and the same results were found between PQ/MQ-SeET and PQ/MQ-DBT.Conclusion SeET relative to DBT did not seem to improve pregnancy outcomes for RIF patients if the embryo quality was comparable between the two groups.Better clinical pregnancy outcomes could be obtained by transferring good-quality embryos,no matter whether in SeET or DBT.Embryo quality plays a more important role in pregnancy outcomes for RIF patients. 展开更多
关键词 recurrent implantation failure sequential embryo transfer frozen-thawed embryo transfer embryo transfer strategies
下载PDF
Mid-term survival of the Optimys short stem: A prospective case series of 500 patients
17
作者 Bryan Hamans Sheryl de Waard +4 位作者 Sjoerd Kaarsemaker Esther R C Janssen Inger N Sierevelt Gino M M J Kerkhoffs Daniël Haverkamp 《World Journal of Orthopedics》 2024年第3期257-265,共9页
BACKGROUND In recent years,there has been an increase in the number of total hip arthroplasty procedures in the younger patient population.This active group has higher expectations of their prosthesis in comparison to... BACKGROUND In recent years,there has been an increase in the number of total hip arthroplasty procedures in the younger patient population.This active group has higher expectations of their prosthesis in comparison to the older population,and there is a greater physical demand for the prosthesis.Short femoral stems were in-troduced to retain proximal bone stock and joint biomechanics and became more common to implant in this specific population.Currently,the long-term survival and functional outcomes of various short stems are still being investigated in different clinics.AIM To determine the 5-year survival of the Optimys hip stem.METHODS This was a prospective multicenter cohort study of 500 patients conducted in two hospitals in the Netherlands.All patients received the Optimys short stem(Mathys Ltd,Bettlach,Switzerland).The primary outcome measure was survival of the hip stem,with revision as the endpoint.The secondary outcome measurements included patient-reported outcome measures(PROMs).Kaplan-Meier analysis was used to calculate the 5-year survival rate.Log-minus-log transformation was performed to calculate the 95%confidence interval(95%CI).Mixed model analyses were performed to assess the course of the PROMs during the 1st 2 years after surgery.Analyses were modeled separately for the 1st and 2nd years to calculate the yearly change in PROMs during both follow-up periods with accompanying 95%CIs.RESULTS The mean age of the total 500 patients was 62.3 years(standard deviation:10.6)and 202 were male(40%).At a median follow-up of 5.5 years(interquartile range:4.5-6.7),7 patients were deceased and 6 revisions were registered,for infection(n=3),subsidence(n=2)and malposition(n=1).This resulted in an overall 5-year survival of 98.8%(95%CI:97.3-99.5).If infection was left out as reason for revision,a stem survival of 99.4%(95%CI:98.1-99.8)was seen.Baseline questionnaires were completed by 471 patients(94%),317 patients(63%)completed the 1-year follow-up questionnaires and 233 patients(47%)completed the 2-year follow-up.Both outcome measures significantly improved across all domains in the 1st year after the operation(P<0.03 for all domains).In the 2nd year after surgery,no significant changes were observed in any domain in comparison to the 1-year follow-up.CONCLUSION The Optimys stem has a 5-year survival of 98.8%.Patient-reported outcome measures increased significantly in the 1st postoperative year with stabilization at the 2-year follow-up. 展开更多
关键词 Total hip arthroplasty Femoral stem short stem Optimys SURVIVAL 5-year survival REVISION PROMs
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
18
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Analysis of the Application and Effect of Homemade Medical Scrotal Support Shorts
19
作者 Jianbin Cheng Xiaohui Liu Lin Lin 《Journal of Clinical and Nursing Research》 2024年第2期244-248,共5页
Objective:To design and manufacture medical scrotal support shorts for patients with enlarged scrotum and observe its application and effect.Methods:40 patients with enlarged scrotum admitted to the basic surgery depa... Objective:To design and manufacture medical scrotal support shorts for patients with enlarged scrotum and observe its application and effect.Methods:40 patients with enlarged scrotum admitted to the basic surgery department from February 2021 to March 2023 were selected and divided into a test group and a control group according to their time of admission,with the test group using scrotal support shorts and the control group using ordinary shorts without scrotal support pockets or diapers.Results:The complication rate of skin injury in the scrotum and the surrounding inguinal area of the patients in the test group was significantly lower than that of the control group(P<0.01).The medical cost covered by patients in the test group was significantly lower than that of the control group(P<0.01)and the hospitalization satisfaction of the patients in the test group was significantly higher than that of the control group(P<0.01).The difference in the therapeutic effect of the test groups was statistically significant when compared with the control group(P<0.05).Conclusion:Homemade medical scrotal support shorts reduced the local enlargement of the scrotum and bleeding,but also protected the scrotum and the surrounding skin to prevent secondary injuries.The process of patient care was simple and promoted their recovery.The length of hospitalization was also decreased,the burden of health care costs was reduced,and the overall comfort and satisfaction of the patient was improved. 展开更多
关键词 Enlarged scrotum Medical scrotal support shorts Nursing care
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
20
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 Continuous precision nursing model Percutaneous coronary angiography Stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部