期刊文献+
共找到122,586篇文章
< 1 2 250 >
每页显示 20 50 100
Using Pearson’s System of Curves to Approximate the Distributions of the Difference between Two Correlated Estimates of Signal-to-Noise Ratios: The Cases of Bivariate Normal and Bivariate Lognormal Distributions
1
作者 Mohamed M. Shoukri 《Open Journal of Statistics》 2024年第3期207-227,共21页
Background: The signal-to-noise ratio (SNR) is recognized as an index of measurements reproducibility. We derive the maximum likelihood estimators of SNR and discuss confidence interval construction on the difference ... Background: The signal-to-noise ratio (SNR) is recognized as an index of measurements reproducibility. We derive the maximum likelihood estimators of SNR and discuss confidence interval construction on the difference between two correlated SNRs when the readings are from bivariate normal and bivariate lognormal distribution. We use the Pearsons system of curves to approximate the difference between the two estimates and use the bootstrap methods to validate the approximate distributions of the statistic of interest. Methods: The paper uses the delta method to find the first four central moments, and hence the skewness and kurtosis which are important in the determination of the parameters of the Pearsons distribution. Results: The approach is illustrated in two examples;one from veterinary microbiology and food safety data and the other on data from clinical medicine. We derived the four central moments of the target statistics, together with the bootstrap method to evaluate the parameters of Pearsons distribution. The fitted Pearsons curves of Types I and II were recommended based on the available data. The R-codes are also provided to be readily used by the readers. 展开更多
关键词 signal-to-noise ratio Bivariate Distributions Bootstrap Methods Delta Method Pearson System of Curves
下载PDF
Acquisition Practice of High Signal-to-Noise Ratio in YTB Block of Sichuan Basin
2
作者 Jun Wu Jiangli Chen +5 位作者 Zhong Li Zengyou Wu Hong Liu Yiwei Li Yong Tang Junguo Du 《Journal of Geoscience and Environment Protection》 2023年第6期229-236,共8页
YTB block in Sichuan basin is a favorable area to exploit oil and gas in shallow tight rock. 3D seismic project of this zone has two characteristics. Firstly, it has high requirements for the tolerance rate of the con... YTB block in Sichuan basin is a favorable area to exploit oil and gas in shallow tight rock. 3D seismic project of this zone has two characteristics. Firstly, it has high requirements for the tolerance rate of the construction process and the acquisition of high signal-to-noise ratio seismic data;Second, there are widely obstacles and noises that lead to difficult acquisition construction organization. In acquisition practice, high signal-to-noise ratio seismic data was obtained by reasonable design of construction scheme, optimization of excitation parameters, improvement of receiving conditions and optimization of obstacle crossing observation system. . 展开更多
关键词 Tight Oil and Gas Tolerance Rate High signal-to-noise ratio OBSTACLE
下载PDF
Effective DOA Estimation Under Low Signal-to-Noise Ratio Based on Multi-Source Information Meta Fusion 被引量:2
3
作者 Yun Wu Xiukun Li Zhimin Cao 《Journal of Beijing Institute of Technology》 EI CAS 2021年第4期377-396,共20页
Efficiently performing high-resolution direction of arrival(DOA)estimation under low signal-to-noise ratio(SNR)conditions has always been a challenge task in the literatures.Obvi-ously,in order to address this problem... Efficiently performing high-resolution direction of arrival(DOA)estimation under low signal-to-noise ratio(SNR)conditions has always been a challenge task in the literatures.Obvi-ously,in order to address this problem,the key is how to mine or reveal as much DOA related in-formation as possible from the degraded array outputs.However,it is certain that there is no per-fect solution for low SNR DOA estimation designed in the way of winner-takes-all.Therefore,this paper proposes to explore in depth the complementary DOA related information that exists in spa-tial spectrums acquired by different basic DOA estimators.Specifically,these basic spatial spec-trums are employed as the input of multi-source information fusion model.And the multi-source in-formation fusion model is composed of three heterogeneous meta learning machines,namely neural networks(NN),support vector machine(SVM),and random forests(RF).The final meta-spec-trum can be obtained by performing a final decision-making method.Experimental results illus-trate that the proposed information fusion based DOA estimation method can really make full use of the complementary information in the spatial spectrums obtained by different basic DOA estim-ators.Even under low SNR conditions,promising DOA estimation performance can be achieved. 展开更多
关键词 direction of arrival(DOA) signal-to-noise ratio(SNR) information fusion meta-learn-ing spatial spectrum
下载PDF
An innovative detection method of high frequency BPSK signal with low signal-to-noise ratio 被引量:2
4
作者 石硕 徐立振 +1 位作者 顾学迈 张宏莉 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2012年第6期93-99,共7页
Based on chaotic oscillator system, this paper proposes a novel method on high frequency low signal- to-noise ratio BPSK( Binary Phase Shift Keying) signal detection. Chaotic oscillator system is a typical non-lin- ... Based on chaotic oscillator system, this paper proposes a novel method on high frequency low signal- to-noise ratio BPSK( Binary Phase Shift Keying) signal detection. Chaotic oscillator system is a typical non-lin- ear system which is sensitive to periodic signals and immune to noise at the same time. Those properties make it possible to detect low signal-to-noise ratio signals. The BPSK signal is a common signal type which is widely used in modern communication. Starting from the analysis of advantages of chaotic, os~.illator system and signal features of the BPSK signal, we put forward a unique method that can detect low signar-to-noise ratio BPSK sig- nals with high frequency. The simulation results show that the novel method can dclct.t low signal-to-noise ratio BPSK signals with frequency in an order of magnitude of l0s Hz, and the input Signal-to-Noise Ratio threshold can be -20 dB. 展开更多
关键词 low signal-to-noise ratio signal detection chaotic oscillator system Binary Phase Shift Keying high frequency
下载PDF
Signal-to-noise ratio of lensless ghost interference with thermal incoherent light 被引量:1
5
作者 张二峰 戴宏毅 陈平形 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期229-234,共6页
Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the trans... Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the transverse length of the object, the position of the object in the imaging system and the transverse size of the light source. Furthermore, the effects of these factors on the SNR are discussed in detail by numerical simulations. 展开更多
关键词 ghost interference ghost imaging signal-to-noise ratio
原文传递
Influence of signal-to-noise ratio on accuracy of spectral analysis by near infrared spectroscopy 被引量:1
6
作者 ZHUANG Xin-gang SHI Xue-shun +3 位作者 LIU Hong-bo LIU Chang-ming ZHANG Peng-ju WANG Heng-fei 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2020年第3期211-216,共6页
As one of the important indicators of spectrometer,signal-to-noise ratio(SNR)reflects the ability of spectrometer to detect weak signals.To investigate the influence of SNR on the prediction accuracy of spectral analy... As one of the important indicators of spectrometer,signal-to-noise ratio(SNR)reflects the ability of spectrometer to detect weak signals.To investigate the influence of SNR on the prediction accuracy of spectral analysis,we first introduce the major factors affecting the spectral SNR.Taking green tea as an example,the influence of spectral SNR on the prediction accuracy of the origin identification model is analyzed by experiments.At the same time,the relationship between the spectral SNR and prediction accuracy of spectral analysis model is fitted.Based on this,the common methods for improving the spectral SNR are discussed.The results show that the accuracy of the prediction set model first decreases slowly,then decreases linearly,and finally tends to be flat as the spectral SNR decreases.Through calculation,in order to achieve the prediction accuracy of prediction model reaching 90%and 85%,the spectral SNR is required to be higher than 23.42 dB and 21.16 dB,respectively.The overall results provide certain parameters support for the development of new online analytical spectroscopic instruments,especially for the technical indicators of SNR. 展开更多
关键词 near infrared spectroscopy signal-to-noise ratio(SNR) partial least squares(PLS) spectral analysis green tea
下载PDF
Calculation method of the signal-to-noise ratio attribute of seismic data based on structural orientation
7
作者 Zhao Yan Mao Ning-Bo Chen Xu 《Applied Geophysics》 SCIE CSCD 2019年第4期455-462,560,共9页
At present,most signal-to-noise ratio(SNR)estimation methods can only calculate the global and not the local SNR of seismic data.This paper proposes a calculation method of a structure-oriented-based seismic SNR attri... At present,most signal-to-noise ratio(SNR)estimation methods can only calculate the global and not the local SNR of seismic data.This paper proposes a calculation method of a structure-oriented-based seismic SNR attribute.The purpose is to characterize the temporal and spatial variation of the seismic data SNR.First,the local slope parameters of the seismic events are calculated using a plane wave decomposition filter.Then,the singular value decomposition method is used to calculate the local seismic data SNR,thereby obtaining it in time and space.The proposed method overcomes the insufficiency of a conventional global SNR to characterize any local seismic data features and uses the SNR as an attribute of seismic data to more accurately describe the signal-noise energy distribution characteristics of seismic data in time and space.The results of a theoretical model test and real data processing show that the SNR attribute can be used not only for seismic data quality evaluation but also for analysis and evaluation of denoising methods. 展开更多
关键词 Seismic data signal-to-noise ratio attribute local slope singular value decomposition structure-oriented
下载PDF
Enhancement of signal-to-noise ratio of ultracold polar NaCs molecular spectra by phase locking detection
8
作者 王文浩 刘文良 +6 位作者 武寄洲 李玉清 王晓锋 刘艳艳 马杰 肖连团 贾锁堂 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期227-231,共5页
We report a method of high-sensitively detecting the weak signal in photoassociation (PA) spectra of ultracold NaCs molecules by phase sensitive-demodulated trap-loss spectra of Na atoms from a photomultiplier tube.... We report a method of high-sensitively detecting the weak signal in photoassociation (PA) spectra of ultracold NaCs molecules by phase sensitive-demodulated trap-loss spectra of Na atoms from a photomultiplier tube. We find that the signal-to-noise ratio (SNR) of the PA spectra is strongly dependent on the integration time and the sensitivity of the lock-in amplifier, and our results show reasonable agreement with the theoretical analyses of the SNR with the demodulation parameters. Meanwhile, we investigate the effect of the interaction time of the PA laser with the colliding Na-Cs atom pairs on the SNR of the PA spectra. The atom loss rate is dependent on both the PA-induced atom loss and the loading of the MOT. The high-sensitive detection of the excited ultracold NaCs molecules lays a solid foundation for further study of the formation and application of ultracold NaCs molecules. 展开更多
关键词 ultracold NaCs molecules PHOTOASSOCIATION high-resolution spectroscopy signal-to-noise ratio
原文传递
Signal-to-noise ratio of Raman signal measured by multichannel detectors
9
作者 Xue-Lu Liu Yu-Chen Leng +2 位作者 Miao-Ling Lin Xin Cong Ping-Heng Tan 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第9期31-44,共14页
Raman spectroscopy has been widely used to characterize the physical properties of two-dimensional materials(2DMs).The signal-to-noise ratio(SNR or S/N ratio)of Raman signal usually serves as an important indicator to... Raman spectroscopy has been widely used to characterize the physical properties of two-dimensional materials(2DMs).The signal-to-noise ratio(SNR or S/N ratio)of Raman signal usually serves as an important indicator to evaluate the instrumental performance rather than Raman intensity itself.Multichannel detectors with outstanding sensitivity,rapid acquisition speed and low noise level have been widely equipped in Raman instruments for the measurement of Raman signal.In this mini-review,we first introduce the recent advances of Raman spectroscopy of 2DMs.Then we take the most commonly used CCD detector and IGA array detector as examples to overview the various noise sources in Raman measurements and analyze their potential influences on SNR of Raman signal in experiments.This overview can contribute to a better understanding on the SNR of Raman signal and the performance of multichannel detector for numerous researchers and instrumental design for industry,as well as offer practical strategies for improving spectral quality in routine measurement. 展开更多
关键词 multichannel detectors signal-to-noise ratio dark noise shot noise
原文传递
Signal-to-noise ratio comparison of angular signal radiography and phase stepping method
10
作者 Wali Faiz 朱佩平 +4 位作者 胡仁芳 高昆 吴朝 鲍园 田扬超 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期173-178,共6页
Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are imp... Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications. 展开更多
关键词 angular signal radiography (ASR) phase-stepping (PS) signal-to-noise ratio (SNRs) information retrieval method
原文传递
Noises and Signal-to-Noise Ratio of Nanosize EIS and ISFET Biosensors 被引量:2
11
作者 Lusine Gasparyan Ilya Mazo +1 位作者 Vahan Simonyan Ferdinand Gasparyan 《Open Journal of Biophysics》 2020年第1期1-12,共12页
The results of comparative theoretical analyzes of the behavior of internal low-frequency noises, signal-to-noise ratio and sensitivity to DNA molecules for EIS and ISFET based nanosize biosensors are presented. It is... The results of comparative theoretical analyzes of the behavior of internal low-frequency noises, signal-to-noise ratio and sensitivity to DNA molecules for EIS and ISFET based nanosize biosensors are presented. It is shown that EIS biosensor is more sensitive to the presence of DNA molecules in aqueous solution than ISFET sensor. Internal electrical noises level decreases with the increase of concentration of DNA molecules in aqueous solution. In the frequency range 10&minus;3 - 103 Hz noises level for EIS sensor about in three orders is higher than for ISFET sensor. In the other hand, signal-to-noise ratio for capacitive EIS biosensor is much higher than for ISFET sensor. 展开更多
关键词 BIOSENSOR Noise Sensitivity signal-to-noise ratio
下载PDF
An Analytical Theory of the Signal-to-Noise Ratio of Hall Plates with Four Contacts and a Single Mirror Symmetry 被引量:1
12
作者 Udo Ausserlechner 《Journal of Applied Mathematics and Physics》 2018年第10期2032-2066,共35页
This work gives an analytical theory of the signal-to-thermal-noise ratio (SNR) of classical Hall plates with four contacts at small magnetic field. In contrast to previous works, the symmetry of the Hall plates is re... This work gives an analytical theory of the signal-to-thermal-noise ratio (SNR) of classical Hall plates with four contacts at small magnetic field. In contrast to previous works, the symmetry of the Hall plates is reduced to only a single mirror axis, whereby the average of potentials of the two output contacts off this mirror axis differs from the average of potentials at the two supply contacts on the mirror axis, i.e. the output common mode differs from 50%. Surprisingly, at fixed power dissipated in the Hall plate, the maximum achievable SNR is only 9% smaller for output common modes of 30% and 70% when compared to the overall optimum at output common modes of 50%. The theory is applied to Vertical Hall effect devices with three contacts on the top surface and one contact being the buried layer in a silicon BiCMOS process. Geometries are found with large contacts and only a moderate loss in SNR. 展开更多
关键词 HALL Plate Vertical HALL Effect Device Geometry Factor CONFORMAL Mapping Signal to Noise ratio SINGLE Mirror SYMMETRY Equivalent RESISTOR Circuit Common Mode Potential
下载PDF
Local Correlated Noise Improvement of Signal-to-Noise Ratio Gain in an Ensemble of Noisy Neuron
13
作者 Tianquan Feng Qingrong Chen Ming Yi 《Journal of Intelligent Learning Systems and Applications》 2018年第3期104-119,共16页
We theoretically investigate the collective response of an ensemble of leaky integrate-and-fire neuron units to a noisy periodic signal by including local spatially correlated noise. By using the linear response theor... We theoretically investigate the collective response of an ensemble of leaky integrate-and-fire neuron units to a noisy periodic signal by including local spatially correlated noise. By using the linear response theory, we obtained the analytic expression of signal-to-noise ratio (SNR). Numerical simulation results show that the rms amplitude of internal noise can be increased up to?an optimal value where the output SNR reaches a maximum value. Due to the existence of the local spatially correlated noise in the units of the ensemble, the SNR gain of the collective ensemble response can exceed unity and can be optimized when the nearest-neighborhood correlation is negative. This nonlinear collective phenomenon of SNR gain amplification in an ensemble of leaky integrate-and-fire neuron units can be related to the array stochastic resonance (SR) phenomenon. Furthermore, we also show that the SNR gain can also be optimized by tuning the number of neuron units, frequency and?amplitude of the weak periodic signal. The present study illustrates the potential to utilize the local spatially correlation noise and the number of ensemble units for optimizing the collective response of the neuron to inputs, as well as a guidance in the design of information processing devices to weak signal detection. 展开更多
关键词 Array Stochastic Resonance signal-to-noise ratio LOCAL Correlation NOISY NEURONS
下载PDF
Study of signal-to-noise ratio driven by colored noise
14
作者 ZHAO Jin 《科技视界》 2016年第2期203-204,共2页
This paper investigates the signal-to-noise ratio(SNR)driven by colored noise and weak input signals.Based on the Cauchy-Schwarz and Rayleigh quotients inequalities,an analytical expression of SNR is developed,and its... This paper investigates the signal-to-noise ratio(SNR)driven by colored noise and weak input signals.Based on the Cauchy-Schwarz and Rayleigh quotients inequalities,an analytical expression of SNR is developed,and its upper band is closely related to the Fisher information of noise.For mimicking the colored noise,we adopt the first-order moving-average model and propose the optimal input signal waveform.The stochastic resonance effect in threshold systems is demonstrated for the Gaussian mixture colored noise.The obtained results will be interesting in the case of improving the nonlinear filter performance by adding noise to the weak signal corrupted by the colored noise. 展开更多
关键词 噪声 信号 科技创新 通信行业
下载PDF
Consistency in responses to conspecific advertisement calls with various signal-to-noise ratios in both sexes of the Anhui tree frog
15
作者 Zhiyue Wang Haohao Ma +4 位作者 Cheng Chen Ruolei Sun Kai Liu Baowei Zhang Guangzhan Fang 《Current Zoology》 SCIE CAS CSCD 2023年第6期718-726,共9页
Environmental noise has a significant negative impact on acoustic communication in most situations,as it influences the production,transmis-sion,and reception of acoustic signals.However,how animals respond to conspec... Environmental noise has a significant negative impact on acoustic communication in most situations,as it influences the production,transmis-sion,and reception of acoustic signals.However,how animals respond to conspecific sounds when there is interference from environmental noise,and whether males and females display convergent behavioral responses in the face of noise masking remain poorly understood.In this study,we investigated the effects of conspecific male advertisement calls with different signal-to-noise ratios on male-male competition and female choice in the Anhui tree frog Rhacophorus zhoukaiyae using playback and phonotaxis experiments,respectively.The results showed that(1)female Anhui tree frogs preferentially selected the conspecific calls with higher SNR compared to calls with lower SNR;(2)males preferen-tially responded vocally to the conspecific calls with higher SNR compared to calls with lower SNR;and(3)males'competitive strategies were flexible in the face of noise interference.These results suggest that preferences of both sexes converge in outcome,and that male competitive strategies may depend on predictable female preferences.This study will provide an important basis for further research on decision-making in animals. 展开更多
关键词 advertisement call female choice male-male competition noise signal-to-noise ratio(SNR)
原文传递
Target tracking methods based on a signal-to-noise ratio model 被引量:2
16
作者 Dai LIU Yong-bo ZHAO +2 位作者 Zi-qiao YUAN Jie-tao LI Guo-ji CHEN 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2020年第12期1804-1814,共11页
In traditional target tracking methods,the angle error and range error are often measured by the empirical value,while observation noise is a constant.In this paper,the angle error and range error are analyzed.They ar... In traditional target tracking methods,the angle error and range error are often measured by the empirical value,while observation noise is a constant.In this paper,the angle error and range error are analyzed.They are influenced by the signalto-noise ratio(SNR).Therefore,a model related to SNR has been established,in which the SNR information is applied for target tracking.Combined with an advanced nonlinear filter method,the extended Kalman filter method based on the SNR model(SNR-EKF)and the unscented Kalman filter method based on the SNR model(SNR-UKF)are proposed.There is little difference between the SNR-EKF and SNR-UKF methods in position precision,but the SNR-EKF method has advantages in computation time and the SNR-UKF method has advantages in velocity precision.Simulation results show that target tracking methods based on the SNR model can greatly improve the tracking performance compared with traditional tracking methods.The target tracking accuracy and convergence speed of the proposed methods have significant improvements. 展开更多
关键词 signal-to-noise ratio(SNR)model Target tracking Angle error Range error Nonlinear filter
原文传递
Signal-to-noise ratio gain of an adaptive neuron model with Gamma renewal synaptic input 被引量:1
17
作者 Yanmei Kang Yuxuan Fu Yaqian Chen 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2022年第1期148-156,共9页
We take an adaptive leaky integrate-and-fire neuron model to explore the effect of non-Poisson neurotransmitter on stochastic resonance and its signal-to-noise ratio(SNR)gain.Event triggered algorithm is adopted to sp... We take an adaptive leaky integrate-and-fire neuron model to explore the effect of non-Poisson neurotransmitter on stochastic resonance and its signal-to-noise ratio(SNR)gain.Event triggered algorithm is adopted to speed up the simulating process.It is revealed that both the output SNR and the SNR gain can be monotonically improved when increasing the shape parameter for Gamma distribution.Particularly,for large signal coupling strength,the 1:1 stochastic phase locking induced by Gamma noise is responsible for the frequency matching stochastic resonance,and the output signal-to-noise ratio can surpass the input signal-to-noise ratio,which is significantly different with Poisson case,while for extremely weak signal coupling strength,the SNR gain peak,which is far larger than unity,is due to noise induced resonance.The observations are meaningful in understanding the neural processing mechanisms from a more realistic viewpoint of synaptic modeling. 展开更多
关键词 Shot noise Gamma renewal point process signal-to-noise ratio gain Adaptive integrate-and-fire model
原文传递
High signal-to-noise ratio fiber laser at 1596 nm based on a Bi/Er/La co-doped silica fiber 被引量:1
18
作者 Lei Yang Jianxiang Wen +6 位作者 Yan Wu Ying Wan Longzhao Zeng Wei Chen Fufei Pang Xiaobei Zhang Tingyun Wang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2022年第5期19-23,共5页
We fabricate a high-performance Bi/Er/La co-doped silica fiber with a fluorescence intensity of-33.8 dBm and a gain coefficient of 1.9 dB/m.With the utilization of the fiber as a gain medium,a linear-cavity fiber lase... We fabricate a high-performance Bi/Er/La co-doped silica fiber with a fluorescence intensity of-33.8 dBm and a gain coefficient of 1.9 dB/m.With the utilization of the fiber as a gain medium,a linear-cavity fiber laser has been constructed,which exhibits a signal-to-noise ratio of 74.9 dB at 1596 nm.It has been demonstrated that the fiber laser has a maximum output power of 107.4 mW,a slope efficiency of up to 17.0%,and a linewidth of less than 0.02 nm.Moreover,an all-fiber single-stage optical amplifier is built up for laser amplification,by which the amplified laser power is up to 410.0 mW with pump efficiency of 33.8%.The results indicate that the laser is capable of high signal-to-noise ratio and narrow linewidth,with potential applications for optical fiber sensing,biomedicine,precision measurement,and the pump source of the mid-infrared fiber lasers. 展开更多
关键词 Bi/Er/La co-doped silica fiber high signal-to-noise ratio laser narrow linewidth
原文传递
Slab Yb:YAG pulse amplifier with high amplification gain and signal-to-noise ratio
19
作者 Jun LIU Jianguo XIN +1 位作者 Ye LANG Jiabin CHEN 《Frontiers of Optoelectronics》 EI CSCD 2017年第1期51-56,共6页
This study experimentally investigated a Yb: YAG pulse laser amplifier with a high amplification gain and a high signal-to-noise ratio (SNR). The highest amplification gain of 172 and highest pulse energy of 131 mJ... This study experimentally investigated a Yb: YAG pulse laser amplifier with a high amplification gain and a high signal-to-noise ratio (SNR). The highest amplification gain of 172 and highest pulse energy of 131 mJ were obtained with the highest SNR of 24.9 dB from a volume gain of 10 mm × 10 mm × 1 mm. The output beam quality values ofM2 = 1.91 in the slow axis and M2 = 1.58 in the fast axis were also achieved. 展开更多
关键词 laser amplifiers ytterbium lasers diode-pumped lasers signal-to-noise ratio (SNR)
原文传递
Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
20
作者 Yilei Shao Aizhu Tao +6 位作者 Hong Jiang Meixiao Shen Dexi Zhu Fan Lu Carol LKarp Yufeng Ye Jianhua Wang 《Eye and Vision》 SCIE 2018年第1期151-162,共12页
Background:Spectral domain optical coherence tomography(SD-OCT)was a useful tool to study accommodation in human eye,but the maximum image depth is limited due to the decreased signal-to-noise ratio(SNR).In this study... Background:Spectral domain optical coherence tomography(SD-OCT)was a useful tool to study accommodation in human eye,but the maximum image depth is limited due to the decreased signal-to-noise ratio(SNR).In this study,improving optical resolutions,speeds and the SNR were achieved by custom built SD-OCT,and the evaluation of the impact of the improvement during accommodation was investigated.Methods:Three systems with different spectrometer designs,including two Charge Coupled Device(CCD)cameras and one Complementary Metal-Oxide-Semiconductor Transistor(CMOS)camera,were tested.We measured the point spread functions of a mirror at different positions to obtain the axial resolution and the SNR of three OCT systems powered with a light source with a 50 nm bandwidth,centered at a wavelength of 840 nm.Two normal subjects,aged 26 and 47,respectively,and one 75-year-old patient with an intraocular lens implanted were imaged.Results:The results indicated that spectrometers using cameras with 4096 camera pixels optimized the axial resolutions,due to the use of the full spectrum provided by the light source.The CCD camera system with 4096 pixels had the highest SNR and the best image quality.The system with the CMOS camera with 4096 pixels had the highest speed but had a compromised SNR compared to the CCD camera with 4096 pixels.Conclusions:Using these three OCT systems,we imaged the anterior segment of the human eye before and after accommodation,which showed similar results among the different systems.The system using the CMOS camera with an ultra-long scan depth,high resolution and high scan speed exhibited the best overall performance and therefore was recommended for imaging real-time accommodation. 展开更多
关键词 Optical coherence tomography Axial resolution signal-to-noise ratio ACCOMMODATION Anterior segment
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部