期刊文献+
共找到362篇文章
< 1 2 19 >
每页显示 20 50 100
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
1
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/ct) Random coincidences Scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
下载PDF
Evaluation of response to gemcitabine plus cisplatin-based chemotherapy using positron emission computed tomography for metastatic bladder cancer
2
作者 HakanÖztürk İnançKarapolat 《World Journal of Clinical Cases》 SCIE 2023年第36期8447-8457,共11页
BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-... BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-line gemcitabine plus cispla-tin-based chemotherapy in patients with metastatic bladder cancer.AIM To evaluate the response to Gemcitabine plus Cisplatin-based chemotherapy using 18FDG-PET/CT imaging in patients with metastatic bladder cancer.METHODS Between July 2007 and April 2019,79 patients underwent 18FDG-PET/CT imaging with the diagnosis of Metastatic Bladder Carcinoma(M-BCa).A total of 42 pa-tients(38 male,4 female)were included in the study,and all had been admi-nistered Gemcitabine plus Cisplatin-based chemotherapy.After completion of the therapy,the patients underwent a repeat 18FDG-PET/CT scan and the results were compared with the PET/CT findings before chemotherapy according to European Organisation for the Research and treatment of cancer criteria.Mean age was 66.1 years and standard deviation was 10.7 years(range:41–84 years).RESULTS Of the patients,seven(16.6%)were in complete remission,17(40.5%)were in partial remission,six(14.3%)had a stable disease,and 12(28.6%)had a pro-gressive disease.The overall response rate was 57.1 percent.CONCLUSION 18FDG-PET/CT can be considered as a successful imaging tool in evaluating response to first-line chemotherapy for metastatic bladder cancer.Anatomical and functional data obtained from PET/CT scans may be useful in the planning of secondline and thirdline chemotherapy. 展开更多
关键词 Metastatic bladder cancer Response to chemotheraphy Positron emission tomography computed tomography 18FDG-PET/ct
下载PDF
Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography 被引量:2
3
作者 Yong Huang Yangjia Lu +5 位作者 Ganlong Li Xinsheng Lai Hong Zhang Chunzhi Tang JunjunYang Gustav Wik 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第6期428-434,共7页
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th... The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint. 展开更多
关键词 acupoint specificity Waiguan (SJ 5) NEEDLING sham needling sham point single-photon emission computed tomography
下载PDF
Indocyanine green plasma clearance rate and 99mTc-galactosyl human serum albumin single-photon emission computed tomography evaluated preoperative remnant liver
4
作者 Kentaro Iwaki Satoshi Kaihara +3 位作者 Ryosuke Kita Koji Kitamura Hiroki Hashida Kenji Uryuhara 《World Journal of Clinical Cases》 SCIE 2022年第25期8844-8853,共10页
BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the prim... BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATEctOMY Indocyanine green Indocyanine green plasma clearance rate Liver function evaluation Remnant liver reserve
下载PDF
Rest Thallium-201/Stress Technetium-99m Sestamibi Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography in Detecting of Chronic Coronary Artery Disease
5
作者 Phuong Kim Huynh Lap Vu Cong +1 位作者 Xuan Quang Truong Canh Nguyen Xuan 《Journal of Pharmacy and Pharmacology》 2016年第5期183-191,共9页
To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspecte... To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspected CAD were enrolled in the prospective study. All patients underwent myocardial perfusion scintigraphy in SPECT with dual isotopes of T1-201 and dipyridamole stress Tc-99m sestamibi. Rest and stress imaging protocol were performed in 2 hours by dose of 3 mCi TI-201 and 25 mCi Tc-99m sestamibi. The acquisition parameters includes LEHR collimator, energy peak of 72 and 167 keV for T1-201 and 140 keV for Tc-99m, 180-degree rotation from RAO to LPO, matrix size 64x64, and 25second/frame/64 frames. The 20-segment model of left ventricle was used in automatic quantitation software. Coronary angiography was used as gold standard. CAD was defined as 50% of lumen stenosis on coronary angiography. Rest TI-201/stress tc-99m sestamibi dual-isotope SPECT demonstrated a sensitivity of 94.59% and specificity of 70%, positive predictive value of 79.54% and negative predictive value of 91.3% in detection of coronary artery disease. Sensitivity and specificity for detecting multi-vessel coronary artery disease were 82.75% and 81.57% for the left anterior descending, 77.77% and 91.83% for left circumflex and 94.11% and 82% for right coronary artery. 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT has high sensitivity, specificity, positive predictive value and negative predictive value in detecting chronic coronary artery disease with greater than 50% stenosis assessed by coronary angiography Moreover, this imaging protocol gives high imaging quality, time-saving and convenience. 展开更多
关键词 MPS (myocardial perfusion scintigarphy) spect (single proton emission computed tomography CAD (coronary arterydisease) CA (coronary angiography).
下载PDF
Hepatic clearance measured with ^(99m)Tc-GSA single-photon emission computed tomography to estimate liver fibrosis 被引量:12
6
作者 Masahiko Taniguchi Atsutaka Okizaki +6 位作者 Kenji Watanabe Koji Imai Koichiro Uchida Takahiro Einama Noriyuki Shuke Naoyuki Miyokawa Hiroyuki Furukawa 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16714-16720,共7页
AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPEC... AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy. 展开更多
关键词 FIBROSIS Technetium-99m-diethylenetri-aminepenta-acetic acid-galactosyl human serum albu-min single-photon emission computed tomography Hepatic clearance Liver resection
下载PDF
Significance of functional hepatic resection rate calculated using 3D CT/^(99m)Tc-galactosyl human serum albumin singlephoton emission computed tomography fusion imaging 被引量:6
7
作者 Yosuke Tsuruga Toshiya Kamiyama +6 位作者 Hirofumi Kamachi Shingo Shimada Kenji Wakayama Tatsuya Orimo Tatsuhiko Kakisaka Hideki Yokoo Akinobu Taketomi 《World Journal of Gastroenterology》 SCIE CAS 2016年第17期4373-4379,共7页
AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission com... AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 &#x000b1; 19.9 and 44.5 &#x000b1; 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P &#x0003c; 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of &#x0003e; 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 &#x000b1; 0.19 vs 0.82 &#x000b1; 0.18, P &#x0003c; 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade &#x02265; 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of &#x0003e; 1000 mL. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATEctOMY Functional hepatic resection rate Parenchymal hepatic resection rate
下载PDF
Qualitative visual trichotomous assessment improves the value of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in predicting the prognosis of diffuse large B-cell lymphoma 被引量:1
8
作者 Xu Zhang Wei Fan +6 位作者 Ying-Ying Hu Zhi-Ming Li Zhong-Jun Xia Xiao-Ping Lin Ya-Rui Zhang Pei-Yan Liang Yuan-Hua Li 《Chinese Journal of Cancer》 SCIE CAS CSCD 2015年第6期21-28,共8页
Introduction:Fluorine-18 fluorodeoxyglucose(18F-FDG)positron emission tomography/computed tomography(PET/CT)is a powerful tool for monitoring the response of diffuse large B-cell lymphoma(DLBCL)to therapy,but the crit... Introduction:Fluorine-18 fluorodeoxyglucose(18F-FDG)positron emission tomography/computed tomography(PET/CT)is a powerful tool for monitoring the response of diffuse large B-cell lymphoma(DLBCL)to therapy,but the criteria to interpret PET/CT results remain under debate.We investigated the value of post-treatment PET/CT in predicting the prognosis of DLBCL patients when interpreted according to qualitative visual trichotomous assessment(QVTA)criteria compared with the Deauvil e criteria.Methods:In this retrospective study,final PET/CT scans of DLBCL patients treated with rituximab-based regimens between October 2005 and November 2010 were interpreted using the Deauvil e and QVTA criteria.Survival curves were estimated using Kaplan-Meier analysis and compared using the log-rank test.Results:A total of 253 patients were enrol ed.The interpretation according to the Deauvil e criteria revealed that 181patients had negative PET/CT scan results and 72 had positive results.The 3 year overal survival(OS)rate was significantly higher in patients with negative scan results than in those with positive results(91.6%vs.57.5%,P<0.001).The72 patients with positive scan results according to the Deauville criteria were divided into two groups by the interpretation according to the QVTA criteria:29 had indeterminate results,and 43 had positive results.The 3 year OS rate was significantly higher in patients with indeterminate scan results than in those with positive results(91.2%vs.33.5%,P<0.001)but was similar between patients with negative and indeterminate scan results(91.6%vs.91.2%,P=0.921).Conclusions:Compared with the Deauvil e criteria,using the QVTA criteria for interpreting post-treatment PET/CT scans of DLBCL patients is likely to reduce the number of false positive results.The QVTA criteria are feasible for therapeutic outcome evaluation and can be used to guide risk-adapted therapy. 展开更多
关键词 正电子发射断层扫描 计算机断层扫描 B细胞淋巴瘤 脱氧葡萄糖 定性视觉 预后 预测 评估
下载PDF
ASSESSMENT OF MYOCARDIAL VIABILITY WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING AND COMPARISON WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
9
作者 Yi-ning Wang Zheng-yu Jin +6 位作者 Zhu-hua Zhang Ling-yan Kong Li-bo Chen Lu Zhou Hong-yi Sun Heng Zhang Qi Miao 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期239-244,共6页
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa... Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease. 展开更多
关键词 magnetic resonance imaging single-photon emission computed tomography myocardialviability
下载PDF
^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography in intrahepatic cholangiocarcinoma: could it be a new paradigm?
10
作者 Masakatsu Tsurusaki Ryohei Kozuki Atsushi Urase 《Hepatobiliary Surgery and Nutrition》 SCIE 2024年第2期379-381,共3页
Intrahepatic cholangiocarcinoma(iCCA)is the second most common type of liver cancer after hepatocellular carcinoma,accounting for 15%of all primary liver neoplasms.In particular,iCCA is the most lethal tumor of these ... Intrahepatic cholangiocarcinoma(iCCA)is the second most common type of liver cancer after hepatocellular carcinoma,accounting for 15%of all primary liver neoplasms.In particular,iCCA is the most lethal tumor of these types,with the greatest increase in incidence in Western countries over the last decade(1,2).Local resection is the only treatment that can achieve cure,but resection rates remain low and survival is still limited to less than 1 year in the presence of locally unresectable or distant metastases(3).Its incidence and mortality have increased in recent years,and the total number of new cases is expected to increase up to 10-fold over the next two to three decades.In recent years,new treatments for iCCA have been developed and overall survival has improved. 展开更多
关键词 Intrahepatic cholangiocarcinoma(iCCA) STAGING ^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography(^(18)F-FDG PET/ct)
原文传递
应用瑞加诺生负荷D-SPECT评价定量血流分数在经皮冠状动脉介入治疗中的作用 被引量:2
11
作者 李柳 李晓燕 +3 位作者 高志超 郑庆厚 赵甫刚 王硕 《西安交通大学学报(医学版)》 CAS CSCD 北大核心 2024年第3期443-448,共6页
目的应用瑞加诺生负荷动态单光子发射计算机断层扫描(dynamic single-photon emission computed tomography,D-SPECT)评价定量血流分数(quantitative flow ratio,QFR)在经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)... 目的应用瑞加诺生负荷动态单光子发射计算机断层扫描(dynamic single-photon emission computed tomography,D-SPECT)评价定量血流分数(quantitative flow ratio,QFR)在经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)中的作用。方法选择2021年6月31日至2023年6月31日在河北医科大学第一医院心内科住院行择期PCI术的200例不稳定型心绞痛患者,年龄(57.56±8.23)岁,按照随机数字表法分为常规组(n=100)和QFR组(n=100),试验采用双盲法进行。常规组根据医师经验行PCI术治疗,QFR组根据QFR测定结果行PCI治疗。所有入选患者术前及PCI术后7 d,应用瑞加诺生负荷D-SPECT,分别采集短轴、垂直长轴、水平长轴的图像,计算心肌17节段分布下心肌灌注总积分、心肌缺血总节段数情况。结果PCI术前两组患者心肌缺血节段数(7.59±3.14 vs.7.48±3.36,P=0.811)、心肌灌注总积分(15.87±7.61 vs.15.63±5.97,P=0.860)差异无统计学意义,QFR组PCI术后7 d的心肌缺血节段数(5.58±3.36 vs.6.51±2.14,P=0.020)和心肌灌注总积分(10.55±4.41 vs.12.96±6.50,P=0.002)显著优于常规组(P<0.05)。结论应用QFR指导PCI可以更好改善患者心肌缺血程度。 展开更多
关键词 瑞加诺生 动态单光子发射计算机断层扫描(D-spect) 经皮冠状动脉介入治疗(PCI) 定量血流分数(QFR)
下载PDF
疑诊原发性甲状旁腺功能亢进症的患者术前^(99m)Tc-MIBI SPECT/CT显像结果的影响因素分析
12
作者 郭月红 黄京伟 +1 位作者 张腾 杨敏福 《首都医科大学学报》 CAS 北大核心 2024年第1期31-35,共5页
目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomograp... 目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomography/computed tomography,SPECT/CT)(以下简称MIBI SPECT/CT)显像结果的影响因素。方法将2019年1月至2023年8月于首都医科大学附属北京朝阳医院疑诊PHPT并在术前完善甲状旁腺MIBI SPECT/CT显像的257例患者作为研究对象。比较MIBI SPECT/CT显像阳性组和阴性组的实验室检查、病理特征及影像特征。采用多因素Logistic回归分析MIBI SPECT/CT显像结果的影响因素。结果单因素分析显示,与阴性组相比,血清总钙、血清甲状旁腺激素(parathyroid hormone,PTH)、碱性磷酸酶(alkaline phosphatase,ALP)水平在阳性组显著升高(P<0.05);病灶的病理类型、最大径、体积及位置在两组间差异有统计学意义(P<0.05)。多因素Logistic回归分析显示,术前血清PTH水平、病灶病理类型、位置及最大径与MIBI SPECT/CT显像结果阳性显著相关(P<0.05)。结论疑诊PHPT患者术前MIBI SPECT/CT显像结果受多重因素影响,术前血清PTH水平、病灶病理类型、位置及最大径是MIBI SPECT/CT显像结果的独立影响因素。 展开更多
关键词 原发性甲状旁腺功能亢进症(PHPT) ^(99m)Tc-甲氧基异丁基异腈(MIBI) spect/ct
下载PDF
医院SPECT/CT机房工作人员甲状腺、眼晶状体和手部受照辐射水平及其防护研究
13
作者 邹作伟 苏雪松 耿建华 《中国医学装备》 2024年第11期25-29,共5页
目的:对单光子发射型电子计算机断层扫描与X射线计算机断层扫描(SPECT/CT)设备机房工作人员甲状腺、眼晶状体和手部的受照剂量及辐射水平进行研究,为评估SPECT/CT机房工作人员受到辐射危害及放射防护提供参考。方法:选取2019年2月至2020... 目的:对单光子发射型电子计算机断层扫描与X射线计算机断层扫描(SPECT/CT)设备机房工作人员甲状腺、眼晶状体和手部的受照剂量及辐射水平进行研究,为评估SPECT/CT机房工作人员受到辐射危害及放射防护提供参考。方法:选取2019年2月至2020年10月中国医学科学院肿瘤医院核医学科在SPECT/CT机房1和SPECT/CT机房2的工作人员各2名,采用光致发光(OSL)剂量计对4名SPECT/CT机房工作人员7个季度的受照剂量进行监测,4名工作人员摆位总量为20 682例患者。工作人员在工作中常规穿戴防护铅衣(0.5 mmPb)和铅围脖(0.5 mmPb)等防护用品,将OSL剂量计分别佩戴在每名机房摆位人员的甲状腺、眼睛附近位置和手部。4名工作人员每人佩戴1套(甲状腺、眼睛附近和手部位置共3枚)OSL剂量计。佩戴OSL剂量计时长为21个月,对甲状腺部位的10 mm深度个人剂量当量[Hp(10)]、眼晶状体部位的3 mm深度个人剂量当量[Hp(3)]和手部的0.07 mm深度个人剂量当量[Hp(0.07)]进行季度监测,评估SPECT/CT机房4名工作人员甲状腺、眼晶状体和手部的受照剂量。4名工作人员均接受常规外照射个人剂量监测。结果:4名工作人员每人年平均摆位例数约2 955例患者,其中仅1名工作人员甲状腺、眼晶状体和手部年平均所受的剂量最高,分别为0.129、0.071和0.151 mSv/a,但远低于放射工作人员剂量约束值5、5和125 mSv/a。结论:SPECT/CT机房4名工作人员为患者摆位时直接接触注射过放射性药物的患者,但其甲状腺、眼睛和手部受照剂量均远低于放射工作人员剂量约束值。按要求合理使用个人防护用品能够有效防护摆位工作中的辐射。 展开更多
关键词 甲状腺 眼晶状体 手部 外照射 当量剂量 单光子发射型电子计算机断层扫描与X射线计算机断层扫描(spect/ct) 机房
下载PDF
富于巨细胞型骨肉瘤SPECT/CT影像学表现
14
作者 赵颖 李培岭 刘玉珂 《罕少疾病杂志》 2024年第3期87-89,共3页
目的探讨分析富于巨细胞型骨肉瘤(GCRO)的影像学特征,以提高对该病的诊断水平。方法回顾性分析我院经过病理证实的2例GCRO患者资料并进行文献总结,总结该病的临床、病理及影像特征,并随访最终结局。结果男性患者1例,38岁,股骨旁GCRO,女... 目的探讨分析富于巨细胞型骨肉瘤(GCRO)的影像学特征,以提高对该病的诊断水平。方法回顾性分析我院经过病理证实的2例GCRO患者资料并进行文献总结,总结该病的临床、病理及影像特征,并随访最终结局。结果男性患者1例,38岁,股骨旁GCRO,女性患者1例,76岁,股骨近端髓腔型GCRO。(1)骨旁GCRO的影像表现:病变位于骨旁,DR表现为骨旁软组织内钙化影,形态不规则;CT表现为骨旁密度不均匀的肿块,内见位于肿块基底部的不规则团状钙化或骨化影,肿块约包绕股骨干的90%;全身骨显像及SPECT/CT融合图像表现为肿块内放射性核素异常浓聚。(2)髓腔型GCRO的影像表现:病变位于股骨近端,CT表现为膨胀性偏心性溶骨性骨质破坏,边缘不连,未见明显骨膜反应;全身骨显像及SPECT/CT图像表现为病变区边缘及中心区的不规则状放射性核素异常浓聚;结论GCRO罕见,影像学易误诊,常规影像学检查具有一定的特征性影像学表现,SPECT/CT结合常规影像学检查有助于诊断,确诊需结合多种影像学资料和组织病理学检查。 展开更多
关键词 巨细胞 骨肉瘤 体层摄影术 X线计算机 spect/ct
下载PDF
数字化X射线摄影与SPECT核素骨显像联合诊断股骨粗隆间骨折的价值
15
作者 郝学伟 武富明 +1 位作者 苏敬阳 于海泉 《中国医学装备》 2024年第1期51-54,共4页
目的:探讨数字化X射线摄影与单光子发射计算机体层扫描(SPECT)核素骨显像对股骨粗隆间骨折的应用价值。方法:选择2017年1月至2020年12月在石家庄市人民医院就诊并诊断为股骨粗隆间骨折的70例患者,按照随机数表法将其分为观察组和对照组... 目的:探讨数字化X射线摄影与单光子发射计算机体层扫描(SPECT)核素骨显像对股骨粗隆间骨折的应用价值。方法:选择2017年1月至2020年12月在石家庄市人民医院就诊并诊断为股骨粗隆间骨折的70例患者,按照随机数表法将其分为观察组和对照组,每组35例,观察组采用数字化X射线摄影联合SPECT核素骨显像进行诊断,对照组采用数字化X射线摄影进行诊断,对比两组诊断结果的准确性。结果:经影像学检测,观察组35例患者中确诊31例(占88.6%),对照组35例患者中确诊24例(占68.6%),观察组诊断准确率高于对照组,差异有统计学意义(x^(2)=4.158,P<0.05)。术前经影像诊断,观察组诊断的骨折块数为(3.57±0.50)块,对照组诊断的骨折块数为(2.67±0.40)块,观察组骨折诊断块数高于对照组,差异有统计学意义(t=8.315,P<0.05);观察组中骨质连续性5例,非连续性30例,对照组中骨质稳定性13例,非稳定性22例,观察组更接近术中骨质连续性和稳定性,两组连续性和稳定性比较差异有统计学意义(x^(2)=12.857、4.644,P<0.05)。结论:数字化X射线摄影联合SPECT核素骨显像对股骨粗隆间骨折具有较高的诊断价值,可为临床诊断提供重要的参考依据。 展开更多
关键词 股骨粗隆间骨折 数字化X射线摄影 spect核素骨显像 诊断价值
下载PDF
碲锌镉心脏专用SPECT的特性及其临床应用进展 被引量:2
16
作者 陈瑶 刘小吉 +1 位作者 蔡敏 李思进 《中国医疗设备》 2023年第12期144-149,共6页
随着半导体探测器碲锌镉(Cadmium-Zinc-Telluride,CZT)心脏专用单光子发射计算机断层成像(Singlephoton EmissionComputed Tomography,SPECT),即CZT-SPECT的出现,核医学在仪器设备上的发展有了新的突破,以性质稳定的CZT半导体材料直接... 随着半导体探测器碲锌镉(Cadmium-Zinc-Telluride,CZT)心脏专用单光子发射计算机断层成像(Singlephoton EmissionComputed Tomography,SPECT),即CZT-SPECT的出现,核医学在仪器设备上的发展有了新的突破,以性质稳定的CZT半导体材料直接取代传统的NaI晶体和光电倍增管。CZT半导体组织密度大、原子序数高,因此对SPECT能量探测范围内的光子具有极高的捕获能力,且具有优异的光电性能,是目前γ射线探测器最为理想的半导体材料。技术上的优势有望为CZT-SPECT的临床应用带来更大的研究意义和更高的诊断效能,现对CZT-SPECT在心脏相关疾病方面的应用情况进行综述,以期为其临床应用提供一定的参考价值。 展开更多
关键词 碲锌镉探测器 碲锌镉-spect NaI晶体 单光子发射计算机断层成像 心血管疾病
下载PDF
基于定量CT身体组分、^(18)F-FDG PET/CT显像预测手术联合新辅助化疗治疗早期乳腺癌预后的价值
17
作者 白丽 苏雪娟 陈体 《海南医学》 CAS 2024年第5期713-718,共6页
目的 分析定量CT (QCT)身体组分、^(18)F-氟脱氧葡萄糖正电子发射型计算机断层显像(^(18)F-FDG PET-CT)对手术联合新辅助化疗(NAC)治疗早期乳腺癌患者预后的预测效能,为临床治疗提供参考。方法 选取2020年3月至2022年10月于南阳市第二... 目的 分析定量CT (QCT)身体组分、^(18)F-氟脱氧葡萄糖正电子发射型计算机断层显像(^(18)F-FDG PET-CT)对手术联合新辅助化疗(NAC)治疗早期乳腺癌患者预后的预测效能,为临床治疗提供参考。方法 选取2020年3月至2022年10月于南阳市第二人民医院接受手术联合NAC治疗的82例早期乳腺癌患者纳入研究,在NAC前和化疗1、3个周期后检测记录QCT参数[L_(1)、L_(2)水平的皮下脂肪面积(SFA)、内脏脂肪面积(VFA)、骨密度(BMD)、L_(3)水平的椎旁肌肉面积(TMA)]、^(18)F-FDG PET/CT显像的最大标准摄取值(SUV_(max))、肿瘤代谢体积(MTV)。NAC结束后进行手术,随访12个月(失访2例),依据有无复发转移分为预后良好组43例和预后不良组37例,比较不同预后患者的QCT参数、^(18)F-FDG PET/CT显像指标,采用受试者工作特征(ROC)曲线获取曲线下面积(AUC)分析其对早期乳腺癌患者预后的预测效能。结果化疗1个周期后,预后良好组患者的SFA、BMD、VFA、MA水平分别为(45.23±4.07) cm^(2)、(128.97±26.53) mg/m^(2)、(78.07±6.69) cm^(2)、(37.36±5.74) cm^(2),明显高于预后不良组的(42.52±3.32) cm^(2)、(112.54±25.82) mg/m^(2)、(73.73±7.25) cm^(2)、(32.94±5.31) cm^(2),差异均有统计学意义(P<0.05);化疗3个周期后,预后良好组患者的SFA、BMD、VFA、MA水平分别为(40.95±3.92) cm^(2)、(113.55±15.87) mg/m^(2)、(73.59±6.17) cm^(2)、(32.67±4.98) cm^(2),明显高于预后不良组的(37.51±3.56) cm^(2)、(95.18±17.45) mg/m^(2)、(70.30±5.14) cm^(2)、(28.52±4.42) cm^(2),差异均有统计学意义(P<0.05);化疗1个周期后,预后良好组患者的SUV_(max)、MTV分别为5.43±1.25、(3.86±0.87)×10^(4)mm,明显低于预后不良组的6.04±1.07、(4.27±0.85)×10^(4)mm,差异均有统计学意义(P<0.05);化疗3个周期后,预后良好组患者的SUV_(max)、MTV分别为3.94±1.06、(2.61±0.70)×10^(4)mm,明显低于预后不良组的4.73±1.21、(3.05±0.93)×10^(4)mm,差异均有统计学意义(P<0.05);经ROC曲线分析结果显示,SFA、BMD、VFA、MA、SUV_(max)、MTV联合预测手术联合NAC治疗早期乳腺癌患者预后的AUC分别为0.898 (95%CI:0.809~0.954)、0.919 (95%CI:0.836~0.968)。结论 NAC过程中检测QCT参数、^(18)F-FDG PET/CT显像指标可预测手术联合NAC治疗早期乳腺癌患者的预后,联合预测的价值较高。 展开更多
关键词 乳腺癌 ^(18)F-氟脱氧葡萄糖正电子发射型计算机断层显像 定量ct 新辅助化疗 骨密度 肿瘤代谢体积
下载PDF
Perioperative Evaluation of Cerebral Blood Flow Using ^123I-labeled N-isopropyl-p-iodoamphetamine Single-Photon Emission Computed Tomography without Blood Sampling in Patients Who Underwent Carotid Artery Stenting
18
作者 Naoki Matsumoto Rei Enatsu +5 位作者 Yasuzumi Matsui Hiroyuki Ikeda Norikazu Yamana Masashi Oda Masaaki Saiki Osamu Narumi 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第13期1616-1618,共3页
The evaluation of regional cerebral vascular reserve (rCVR) with single-photon emission computed tomography (SPECT) is useful for predicting cerebral hyperperfusion following carotid artery stenting (CAS) and ca... The evaluation of regional cerebral vascular reserve (rCVR) with single-photon emission computed tomography (SPECT) is useful for predicting cerebral hyperperfusion following carotid artery stenting (CAS) and carotidendarterectomy (CEA). 展开更多
关键词 Carotid Artery Stenosis Carotid Artery Stenting N-isopropyl-p-iodoamphetamine-Rest and True Acetazolamide Images Estimated Method Using Dynamic Acquisition single-photon emission computed tomography
原文传递
Correlations of single photon emission computed tomography joints scan and bone metabolic markers in active rheumatoid arthritis
19
作者 高海燕 《China Medical Abstracts(Internal Medicine)》 2017年第1期14-15,共2页
Objective To explore the correlation between quantitative value of joint bone scan by single photon emission computed tomography(SPECT)and serum bone metabolic markers in patients with active rheumatoid arthritis(RA).... Objective To explore the correlation between quantitative value of joint bone scan by single photon emission computed tomography(SPECT)and serum bone metabolic markers in patients with active rheumatoid arthritis(RA).Methods Clinical data of 60 newly diagnosed RA patients were retrospectively collected in Department 展开更多
关键词 BONE Correlations of single photon emission computed tomography joints scan and bone metabolic markers in active rheumatoid arthritis spect PINP
原文传递
SPECT/CT融合骨显像评价四肢骨折患者的愈合情况及与氧化应激水平的关系研究 被引量:1
20
作者 吴继云 邓亚开 +1 位作者 陈伟南 刘卫峰 《中国医学装备》 2023年第11期64-67,共4页
目的:探讨单光子发射计算机断层扫描(SPECT)/CT融合骨显像评价四肢骨折患者的愈合情况及与氧化应激水平的关系。方法:选取在医院接受治疗的40例四肢骨折患者,所有患者术后采用SPECT/CT图像融合显像判断骨愈合情况,并进行超氧化物岐化酶(... 目的:探讨单光子发射计算机断层扫描(SPECT)/CT融合骨显像评价四肢骨折患者的愈合情况及与氧化应激水平的关系。方法:选取在医院接受治疗的40例四肢骨折患者,所有患者术后采用SPECT/CT图像融合显像判断骨愈合情况,并进行超氧化物岐化酶(SOD)、硫代巴比妥酸法检测丙二醛(MDA)检测;对所有患者进行随访,最终骨折愈合结果均经手术或随访证实。根据骨折愈合情况将40例四肢骨折患者分为12周愈合组(10例)、16周愈合组(25例)和延迟愈合组(5例)。比较3组SOD、MDA水平,采用Pearson相关性分析SOD、MDA与骨折愈合进度的相关性。结果:40例四肢骨折患者经SPECT/CT融合图像显示,其中30例放射性浓聚连续性通过骨折线并跨越骨折两端,SPECT/CT融合图像判断12周愈合组和16周愈合组患者骨折愈合的准确率为85.71%(30/35);12周愈合组、16周愈合组和延迟愈合组SOD及MDA水平比较,差异有统计学意义(F=6.103,F=53.344;P<0.05);12周愈合组SOD水平明显高于16周愈合组,16周愈合组明显高于延迟愈合组,12周愈合组MDA水平明显低于16周愈合组,16周愈合组明显低于延迟愈合组;Pearson相关性分析结果显示,四肢骨折患者的愈合情况及与SOD、MDA均存在相关性(r=-0.324,r=0.612;P<0.05)。结论:SPECT/CT融合骨显像能为评价四肢骨折愈合提供客观、准确的参考依据,具有重要的临床应用价值。骨折愈合程度与氧化应激指标存在相关性,可结合氧化应激指标综合进行四肢骨折愈合情况的判断,以提高诊断的准确性。 展开更多
关键词 单光子发射计算机断层扫描(spect)/ct融合骨显像 四肢骨折 愈合情况 氧化应激水平
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部