As a widely used flood energy dissipator, the stepped spillway can significantly dissipate the kinetic or hydraulic energy due to the air-entrainment in skimming flow over the steps. The free-surface aeration involves...As a widely used flood energy dissipator, the stepped spillway can significantly dissipate the kinetic or hydraulic energy due to the air-entrainment in skimming flow over the steps. The free-surface aeration involves the sharp deformation of the free surface and the complex turbulent shear flows. In this study, the volume of fluid (VOF), mixture, and Eulerian methods are utilized to simulate the air-entrainment by coupling with the Reynolds-averaged Navier-Stokes/large eddy simulation (RANS/LES) turbulence models. The free surface deformation, air volume fraction, pressure, and velocity are compared for the three different numerical methods. Only the Eulerian+RANS method fails to capture the free-surface aeration. The air volume fraction predicted by the VOF+LES method best matches the experimental measurement, while the mixture+LES method predicts the inception point of the air entrainment more accurately.展开更多
Numerical simulation of stepped channel flow was conducted using turbulence models based on the VOF technique. Stepped channel flow is a complicated air-water two-phase flow with free surface, which can be divided int...Numerical simulation of stepped channel flow was conducted using turbulence models based on the VOF technique. Stepped channel flow is a complicated air-water two-phase flow with free surface, which can be divided into three flow regimes: skimming flow, nappe flow and transition flow. The characteristics of skimming flow over mild stepped channel was investigated, including friction factors, air concentration profiles velocity field, clear-water and bulked depths, static pressure, etc. Smooth channel flow was also simulated to compare the hydraulic characteristics of the stepped channel flow with the smooth one. Comparisons between the computed and the measured were made. Furthermore, comparison of the computed air concentration with Straub and Anderson's data was also performed. The Fluent 6.1 software was employed to conduct this numerical simulation work.展开更多
基金supported by the Guangdong Special Research Fund of Public Welfare and Capacity Building(2015A020216008)the Special Program for Applied Research on Super Computation of the NSFC-Guangdong Joint Fund(the second phase)
文摘As a widely used flood energy dissipator, the stepped spillway can significantly dissipate the kinetic or hydraulic energy due to the air-entrainment in skimming flow over the steps. The free-surface aeration involves the sharp deformation of the free surface and the complex turbulent shear flows. In this study, the volume of fluid (VOF), mixture, and Eulerian methods are utilized to simulate the air-entrainment by coupling with the Reynolds-averaged Navier-Stokes/large eddy simulation (RANS/LES) turbulence models. The free surface deformation, air volume fraction, pressure, and velocity are compared for the three different numerical methods. Only the Eulerian+RANS method fails to capture the free-surface aeration. The air volume fraction predicted by the VOF+LES method best matches the experimental measurement, while the mixture+LES method predicts the inception point of the air entrainment more accurately.
文摘Numerical simulation of stepped channel flow was conducted using turbulence models based on the VOF technique. Stepped channel flow is a complicated air-water two-phase flow with free surface, which can be divided into three flow regimes: skimming flow, nappe flow and transition flow. The characteristics of skimming flow over mild stepped channel was investigated, including friction factors, air concentration profiles velocity field, clear-water and bulked depths, static pressure, etc. Smooth channel flow was also simulated to compare the hydraulic characteristics of the stepped channel flow with the smooth one. Comparisons between the computed and the measured were made. Furthermore, comparison of the computed air concentration with Straub and Anderson's data was also performed. The Fluent 6.1 software was employed to conduct this numerical simulation work.