This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typ...This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.展开更多
This paper provides a summary of the objectives and principles which underpin the 2004 edition of the New Zealand earthquake design standard,AS/NZS 1170 Part 5.As with many modern earthquake design standards,the New Z...This paper provides a summary of the objectives and principles which underpin the 2004 edition of the New Zealand earthquake design standard,AS/NZS 1170 Part 5.As with many modern earthquake design standards,the New Zealand earthquake design standard recognizes that earthquake resistant design that only addresses life safety goals without addressing both operational continuity of essential facilities and damage control,falls short of public expectations.Such standards not longer meet societal expectations.The paper outlines how these issues have been addressed within New Zealand,and some of the issues addressed when preparing appendices to the standard to provide guidance for materials standard writers to ensure consistency with the proposed approach.Recognizing the significance of non-structural components and parts of buildings in both damage control and operational continuity has been an important step forward in attaining the performance levels required.展开更多
Building performance simulation (BPS) is a crucial tool towards the design of projects better adapted its climatic context. In this sense, the objective of this research is to evaluate a method of thermal comfort anal...Building performance simulation (BPS) is a crucial tool towards the design of projects better adapted its climatic context. In this sense, the objective of this research is to evaluate a method of thermal comfort analysis of schools in three Brazilian cities using BPS. The methodological procedures involved a literature review, in which the simulation tool and analysis method were chosen. Following simulations with the software DesignBuilder were performed using as study case a standard school typology designed by the General Coordination of Educational Infrastructure (CODIN/FNDE). This article evaluates its percentage occupied comfort hours in 3 reference cities: Cuiabá-MT, Brasília-DF, and Curitiba-PR. The results show respectively, for the cities of Curitiba, Brasília and Cuiabá, percentages of comfort hours of 76%, 70%, and 23%. The research states that the project must have different strategies for different climates. Finally, this article recommends this method should be applied to other cities and buildings.展开更多
One of the challenges in construction of nearly and net ZEBs is how to truly achieve the nearly and net energy goals after building occupancy.Traditional building design standards and practices are mostly based on des...One of the challenges in construction of nearly and net ZEBs is how to truly achieve the nearly and net energy goals after building occupancy.Traditional building design standards and practices are mostly based on design performance evaluation,but practices show that many designed nearly/net ZEBs failed to achieve the energy goals after building occupancy.To facilitate the practical achievement of nearly and net ZEBs,recently most of the newly-released ZEB design standards have turned to post-occupancy performance evaluation,posing great challenges to nearly and net ZEB design.However,the detailed challenges have not be comprehensively investigated,and effective optimal design methods which can facilitate the achievement of nearly and net ZEBs under these standards are still absent.In this study,new challenges of nearly and net ZEB design under the post-occupancy performance-based design standards are fully investigated,and a risk-benefit based optimal design method is proposed to facilitate the achievement of nearly and net ZEBs under these standards.The newly-released ZEB standard in China is taken as an example to investigate the challenges and test the proposed method.Results show that nearly and net ZEBs designed using conventional design method have high risk in achieving energy goals under these standards due to high risk in satisfying the requirement regarding non-renewable primary energy consumption after building occupancy.The proposed design method is effective to facilitate achieving energy goals under these standards based on the risk that decision-makers would like to take.展开更多
基金Sponsored by the National Project of Scientific and Technical Supporting Programs Funded by Ministry of Science & Technology of China (Grant No.2012BAJ06B04-02)
文摘This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.
文摘This paper provides a summary of the objectives and principles which underpin the 2004 edition of the New Zealand earthquake design standard,AS/NZS 1170 Part 5.As with many modern earthquake design standards,the New Zealand earthquake design standard recognizes that earthquake resistant design that only addresses life safety goals without addressing both operational continuity of essential facilities and damage control,falls short of public expectations.Such standards not longer meet societal expectations.The paper outlines how these issues have been addressed within New Zealand,and some of the issues addressed when preparing appendices to the standard to provide guidance for materials standard writers to ensure consistency with the proposed approach.Recognizing the significance of non-structural components and parts of buildings in both damage control and operational continuity has been an important step forward in attaining the performance levels required.
基金The first author wishes thanks to the Brazilian National Council for Scientific and Technological Development(CNPq)for supporting this research.
文摘Building performance simulation (BPS) is a crucial tool towards the design of projects better adapted its climatic context. In this sense, the objective of this research is to evaluate a method of thermal comfort analysis of schools in three Brazilian cities using BPS. The methodological procedures involved a literature review, in which the simulation tool and analysis method were chosen. Following simulations with the software DesignBuilder were performed using as study case a standard school typology designed by the General Coordination of Educational Infrastructure (CODIN/FNDE). This article evaluates its percentage occupied comfort hours in 3 reference cities: Cuiabá-MT, Brasília-DF, and Curitiba-PR. The results show respectively, for the cities of Curitiba, Brasília and Cuiabá, percentages of comfort hours of 76%, 70%, and 23%. The research states that the project must have different strategies for different climates. Finally, this article recommends this method should be applied to other cities and buildings.
基金supported by a grant(152079/18E)from the Research Grant Council(RGC)of the Hong Kong SAR,China.
文摘One of the challenges in construction of nearly and net ZEBs is how to truly achieve the nearly and net energy goals after building occupancy.Traditional building design standards and practices are mostly based on design performance evaluation,but practices show that many designed nearly/net ZEBs failed to achieve the energy goals after building occupancy.To facilitate the practical achievement of nearly and net ZEBs,recently most of the newly-released ZEB design standards have turned to post-occupancy performance evaluation,posing great challenges to nearly and net ZEB design.However,the detailed challenges have not be comprehensively investigated,and effective optimal design methods which can facilitate the achievement of nearly and net ZEBs under these standards are still absent.In this study,new challenges of nearly and net ZEB design under the post-occupancy performance-based design standards are fully investigated,and a risk-benefit based optimal design method is proposed to facilitate the achievement of nearly and net ZEBs under these standards.The newly-released ZEB standard in China is taken as an example to investigate the challenges and test the proposed method.Results show that nearly and net ZEBs designed using conventional design method have high risk in achieving energy goals under these standards due to high risk in satisfying the requirement regarding non-renewable primary energy consumption after building occupancy.The proposed design method is effective to facilitate achieving energy goals under these standards based on the risk that decision-makers would like to take.