Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of va...Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of various spectroscopic techniques, mainly including atomic absorption spectrometry (AAS) inductively coupled plasma emission spectrometry (ICP-AES) X-ray fluorescence spectroscopy (XRF) atomic fluorescence spectroscopy (AFS) direct reading spectroscopy (OES) glow discharge emission spectroscopy (GD-OSE) laser-induced breakdown spectroscopy (LIBS), in the formulation of non-ferrous metal standards in China. The AAS method was the most widely used single-element microanalysis method among the non-ferrous metal standards. The ICP-AES method was good at significant advantages in the simultaneous detection of multiple elements. The XRF method was increasingly used in the determination of primary and secondary trace elements due to its simple sample preparation and high efficiency. The AFS was mostly detected by single-element trace analysis. OES GD-OES and LIBS were playing an increasingly important role in the new demand area for non-ferrous metals. This paper discussed matrix elimination, sample digestion, sample preparation, instrument categories and other aspects of some standards, and summarized the advantages of spectral analysis and traditional chemical analysis methods. The new methods of future spectroscopic technology had been illustrated in the process of developing non-ferrous metal standards.展开更多
Long tree-ring chronologies can be developed by overlapping data from living trees with data from fossil trees through cross-dating.However,low-frequency climate signals are lost when standardizing tree-ring series du...Long tree-ring chronologies can be developed by overlapping data from living trees with data from fossil trees through cross-dating.However,low-frequency climate signals are lost when standardizing tree-ring series due to the"segment length curse".To alleviate the segment length curse and thus improve the standardization method for developing long tree-ring chronologies,here we first calculated a mean value for all the tree ring series by overlapping all of the tree ring series.The growth trend of the mean tree ring width(i.e.,cumulated average growth trend of all the series)was determined using ensemble empirical mode decomposition.Then the chronology was developed by dividing the mean value by the growth trend of the mean value.Our improved method alleviated the problem of trend distortion.Long-term signals were better preserved using the improved method than in previous detrending methods.The chronologies developed using the improved method were better correlated with climate than those developed using conservative methods.The improved standardization method alleviates trend distortion and retains more of the low-frequency climate signals.展开更多
The implementation of artificial intelligence(AI)in a smart society,in which the analysis of human habits is mandatory,requires automated data scheduling and analysis using smart applications,a smart infrastructure,sm...The implementation of artificial intelligence(AI)in a smart society,in which the analysis of human habits is mandatory,requires automated data scheduling and analysis using smart applications,a smart infrastructure,smart systems,and a smart network.In this context,which is characterized by a large gap between training and operative processes,a dedicated method is required to manage and extract the massive amount of data and the related information mining.The method presented in this work aims to reduce this gap with near-zero-failure advanced diagnostics(AD)for smart management,which is exploitable in any context of Society 5.0,thus reducing the risk factors at all management levels and ensuring quality and sustainability.We have also developed innovative applications for a humancentered management system to support scheduling in the maintenance of operative processes,for reducing training costs,for improving production yield,and for creating a human–machine cyberspace for smart infrastructure design.The results obtained in 12 international companies demonstrate a possible global standardization of operative processes,leading to the design of a near-zero-failure intelligent system that is able to learn and upgrade itself.Our new method provides guidance for selecting the new generation of intelligent manufacturing and smart systems in order to optimize human–machine interactions,with the related smart maintenance and education.展开更多
[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solven...[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple.展开更多
The supervision and administration of cosmetics and its two supporting documents related to efficacy,cosmetics classification rules and classification catalogue and evaluation standard of cosmetic efficacy claims,have...The supervision and administration of cosmetics and its two supporting documents related to efficacy,cosmetics classification rules and classification catalogue and evaluation standard of cosmetic efficacy claims,have been successively introduced and implemented,making China’s cosmetics industry officially enter the era of efficacy evaluation.In the time window when the new era is coming,the definitions of cosmetics in China and other countries are compared.The latest status and progress of regulations on cosmetic efficacy claims in China and other countries are summarized,and the standard methods or guidance of cosmetic efficacy evaluation at home and abroad are introduced.The enlightenment from the supervision systems of cosmetic efficacy in other cosmetic consumer markets around the world are discussed.In addition,the opportunities and challenges for cosmetic enterprises under the background of cosmetic law reform in China are also prospected.展开更多
Sulfur speciation and concentration in geothermal water are of great significance for the research and utilization of the water resources.In most situations,it is necessary to determine the total sulfur in geothermal ...Sulfur speciation and concentration in geothermal water are of great significance for the research and utilization of the water resources.In most situations,it is necessary to determine the total sulfur in geothermal water.In this study,the method was established for the determination of determining total sulfur content-the inductively coupled plasma-atomic emission spectrometry(ICP-AES),with the wavelength of 182.034 nm selected in spectral line of sulfur.It was identified that the optimal working conditions of the ICP-AES instrument were 1200 W for high frequency generator power 9 mm for vertical observation height,0.30 MPa atomizer pressure,and 50 r/min analytical pump speed.The matrix interference of the method was eliminated by the matrix matching method.Using this method,sulfur detection limit and minimum quantitative detection limit were 0.028 mg/L and 0.110 mg/L,respectively,whilst the linear range was 0.0-100.0 mg/L.The recovery rate of sample was between 90.67%and 108.7%,and the relative standard deviation(RSD)was between 0.36%and 2.14%.The method was used to analyze the actual samples and the results were basically consistent with the industry standard method.With high analysis efficiency,the method has low detection limit and minimum quantitative detection limit,wide linear range,good precision and accuracy,and provides an important detection method for the determination of total sulfur in geothermal water.展开更多
Dispersion parameter is an important parameter for the establishment of groundwater solute transport model.The dispersion test uses sodium chloride as a tracer,which was conducted in a site in Jilin City.The standard ...Dispersion parameter is an important parameter for the establishment of groundwater solute transport model.The dispersion test uses sodium chloride as a tracer,which was conducted in a site in Jilin City.The standard curve comparison method was used to solve the dispersion parameters of the aquifer under the natural flow field.The test results show that under the natural flow field,the longitudinal dispersion of unconfined aquifer in Jilin City is 0.400m,and the transverse dispersion is 1.933×10-5~6.557×10-3m;while the longitudinal dispersion coefficient is 0.246m2/d,the transverse dispersion coefficient is 1.191×10-5~4.039×10-3m2/d.The above results can provide an important parameter basis for the establishment of groundwater solute transport model,the accurate prediction of temporal and spatial variation of pollutant concentration in groundwater and the formulation of groundwater pollution prevention and control scheme.展开更多
Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix(PMR) using single reference standard.Methods: The f...Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix(PMR) using single reference standard.Methods: The four components including emodin-8-O-β-D-(EMG), physcion-8-O-β-D-glucoside, emodin and physcion were separated on an ODS C18 column within 13 min and detected at 280 nm. Emodin was selected as the reference standard, and the response factor for each analyte with respect to emodin were calculated. Robustness were also tested including different columns, equipments, temperatures, detection wavelengths, and other chromatographic conditions which might influence stability of response factors.Results: The method was validated in terms of linearity(r^2> 0.9995), LOQs(0.820–3.05 ng/m L), LODs(0.180–0.920 ng/m L), precision,accuracy(95.8–103.6%, RSD < 2.80%) and stability. A total of 40 batches of PMR were analyzed and the results were found to have no statistically significant differences compared with those obtained using the external standard method.Conclusion: This work provided a single standard to determine multi-components method for quantitation of four anthraquinones in PMR,which could be applied in the quality control of this herbal drug.展开更多
Headspace sampling-gas chromatography(HS-GC)coupled with an internal standard method(ISM)was developed to analyze the volatile flavor compounds in top fermented wheat beer in the laboratory.Eight compounds,i.e.acetald...Headspace sampling-gas chromatography(HS-GC)coupled with an internal standard method(ISM)was developed to analyze the volatile flavor compounds in top fermented wheat beer in the laboratory.Eight compounds,i.e.acetaldehyde,N-propanol,ethyl acetate,isobutyl alcohol,isoamyl alcohol,isoamyl acetate,ethyl hexanoate and ethyl octanoate were separated and quantified.This method was validated to ensure the quality of the results:the precision was satisfactory with relative standard deviation(RSD)in the range of 1.51%-4.22%,recoveries for all the analytes ranged from 95.15%to 99.85%,and the limits of detection were in the range of 0.0002-0.024 mg/L.Results of real wheat beer samples analyzed using this method showed that the volatile compound concentrations were in the range of 0.08-99.91 mg/L.Results suggested that this method exhibited good reproducibility,selectivity and high precision,and it can be useful for the analysis of routine beer samples.展开更多
文摘Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of various spectroscopic techniques, mainly including atomic absorption spectrometry (AAS) inductively coupled plasma emission spectrometry (ICP-AES) X-ray fluorescence spectroscopy (XRF) atomic fluorescence spectroscopy (AFS) direct reading spectroscopy (OES) glow discharge emission spectroscopy (GD-OSE) laser-induced breakdown spectroscopy (LIBS), in the formulation of non-ferrous metal standards in China. The AAS method was the most widely used single-element microanalysis method among the non-ferrous metal standards. The ICP-AES method was good at significant advantages in the simultaneous detection of multiple elements. The XRF method was increasingly used in the determination of primary and secondary trace elements due to its simple sample preparation and high efficiency. The AFS was mostly detected by single-element trace analysis. OES GD-OES and LIBS were playing an increasingly important role in the new demand area for non-ferrous metals. This paper discussed matrix elimination, sample digestion, sample preparation, instrument categories and other aspects of some standards, and summarized the advantages of spectral analysis and traditional chemical analysis methods. The new methods of future spectroscopic technology had been illustrated in the process of developing non-ferrous metal standards.
文摘Long tree-ring chronologies can be developed by overlapping data from living trees with data from fossil trees through cross-dating.However,low-frequency climate signals are lost when standardizing tree-ring series due to the"segment length curse".To alleviate the segment length curse and thus improve the standardization method for developing long tree-ring chronologies,here we first calculated a mean value for all the tree ring series by overlapping all of the tree ring series.The growth trend of the mean tree ring width(i.e.,cumulated average growth trend of all the series)was determined using ensemble empirical mode decomposition.Then the chronology was developed by dividing the mean value by the growth trend of the mean value.Our improved method alleviated the problem of trend distortion.Long-term signals were better preserved using the improved method than in previous detrending methods.The chronologies developed using the improved method were better correlated with climate than those developed using conservative methods.The improved standardization method alleviates trend distortion and retains more of the low-frequency climate signals.
文摘The implementation of artificial intelligence(AI)in a smart society,in which the analysis of human habits is mandatory,requires automated data scheduling and analysis using smart applications,a smart infrastructure,smart systems,and a smart network.In this context,which is characterized by a large gap between training and operative processes,a dedicated method is required to manage and extract the massive amount of data and the related information mining.The method presented in this work aims to reduce this gap with near-zero-failure advanced diagnostics(AD)for smart management,which is exploitable in any context of Society 5.0,thus reducing the risk factors at all management levels and ensuring quality and sustainability.We have also developed innovative applications for a humancentered management system to support scheduling in the maintenance of operative processes,for reducing training costs,for improving production yield,and for creating a human–machine cyberspace for smart infrastructure design.The results obtained in 12 international companies demonstrate a possible global standardization of operative processes,leading to the design of a near-zero-failure intelligent system that is able to learn and upgrade itself.Our new method provides guidance for selecting the new generation of intelligent manufacturing and smart systems in order to optimize human–machine interactions,with the related smart maintenance and education.
文摘[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple.
文摘The supervision and administration of cosmetics and its two supporting documents related to efficacy,cosmetics classification rules and classification catalogue and evaluation standard of cosmetic efficacy claims,have been successively introduced and implemented,making China’s cosmetics industry officially enter the era of efficacy evaluation.In the time window when the new era is coming,the definitions of cosmetics in China and other countries are compared.The latest status and progress of regulations on cosmetic efficacy claims in China and other countries are summarized,and the standard methods or guidance of cosmetic efficacy evaluation at home and abroad are introduced.The enlightenment from the supervision systems of cosmetic efficacy in other cosmetic consumer markets around the world are discussed.In addition,the opportunities and challenges for cosmetic enterprises under the background of cosmetic law reform in China are also prospected.
基金supported by the Fundamental Research Fund Project(SK201908)of the Institute of Hydrogeology and Environmental Geology,Chinese Academy of Geological Sciences.
文摘Sulfur speciation and concentration in geothermal water are of great significance for the research and utilization of the water resources.In most situations,it is necessary to determine the total sulfur in geothermal water.In this study,the method was established for the determination of determining total sulfur content-the inductively coupled plasma-atomic emission spectrometry(ICP-AES),with the wavelength of 182.034 nm selected in spectral line of sulfur.It was identified that the optimal working conditions of the ICP-AES instrument were 1200 W for high frequency generator power 9 mm for vertical observation height,0.30 MPa atomizer pressure,and 50 r/min analytical pump speed.The matrix interference of the method was eliminated by the matrix matching method.Using this method,sulfur detection limit and minimum quantitative detection limit were 0.028 mg/L and 0.110 mg/L,respectively,whilst the linear range was 0.0-100.0 mg/L.The recovery rate of sample was between 90.67%and 108.7%,and the relative standard deviation(RSD)was between 0.36%and 2.14%.The method was used to analyze the actual samples and the results were basically consistent with the industry standard method.With high analysis efficiency,the method has low detection limit and minimum quantitative detection limit,wide linear range,good precision and accuracy,and provides an important detection method for the determination of total sulfur in geothermal water.
基金National Joint Foundation for Natural Science Focus(Project No.:U 19A20107).
文摘Dispersion parameter is an important parameter for the establishment of groundwater solute transport model.The dispersion test uses sodium chloride as a tracer,which was conducted in a site in Jilin City.The standard curve comparison method was used to solve the dispersion parameters of the aquifer under the natural flow field.The test results show that under the natural flow field,the longitudinal dispersion of unconfined aquifer in Jilin City is 0.400m,and the transverse dispersion is 1.933×10-5~6.557×10-3m;while the longitudinal dispersion coefficient is 0.246m2/d,the transverse dispersion coefficient is 1.191×10-5~4.039×10-3m2/d.The above results can provide an important parameter basis for the establishment of groundwater solute transport model,the accurate prediction of temporal and spatial variation of pollutant concentration in groundwater and the formulation of groundwater pollution prevention and control scheme.
基金supported by the traditional Chinese Medicine Industry Special Scientific Research (No.201307002)the National New Drug Innovation Major Project of China (No.2012ZX09304005002)A Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)
文摘Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix(PMR) using single reference standard.Methods: The four components including emodin-8-O-β-D-(EMG), physcion-8-O-β-D-glucoside, emodin and physcion were separated on an ODS C18 column within 13 min and detected at 280 nm. Emodin was selected as the reference standard, and the response factor for each analyte with respect to emodin were calculated. Robustness were also tested including different columns, equipments, temperatures, detection wavelengths, and other chromatographic conditions which might influence stability of response factors.Results: The method was validated in terms of linearity(r^2> 0.9995), LOQs(0.820–3.05 ng/m L), LODs(0.180–0.920 ng/m L), precision,accuracy(95.8–103.6%, RSD < 2.80%) and stability. A total of 40 batches of PMR were analyzed and the results were found to have no statistically significant differences compared with those obtained using the external standard method.Conclusion: This work provided a single standard to determine multi-components method for quantitation of four anthraquinones in PMR,which could be applied in the quality control of this herbal drug.
文摘Headspace sampling-gas chromatography(HS-GC)coupled with an internal standard method(ISM)was developed to analyze the volatile flavor compounds in top fermented wheat beer in the laboratory.Eight compounds,i.e.acetaldehyde,N-propanol,ethyl acetate,isobutyl alcohol,isoamyl alcohol,isoamyl acetate,ethyl hexanoate and ethyl octanoate were separated and quantified.This method was validated to ensure the quality of the results:the precision was satisfactory with relative standard deviation(RSD)in the range of 1.51%-4.22%,recoveries for all the analytes ranged from 95.15%to 99.85%,and the limits of detection were in the range of 0.0002-0.024 mg/L.Results of real wheat beer samples analyzed using this method showed that the volatile compound concentrations were in the range of 0.08-99.91 mg/L.Results suggested that this method exhibited good reproducibility,selectivity and high precision,and it can be useful for the analysis of routine beer samples.