The anisotropic mechanical behavior of rocks under high-stress and high-temperature coupled conditions is crucial for analyzing the stability of surrounding rocks in deep underground engineering.This paper is devoted ...The anisotropic mechanical behavior of rocks under high-stress and high-temperature coupled conditions is crucial for analyzing the stability of surrounding rocks in deep underground engineering.This paper is devoted to studying the anisotropic strength,deformation and failure behavior of gneiss granite from the deep boreholes of a railway tunnel that suffers from high tectonic stress and ground temperature in the eastern tectonic knot in the Tibet Plateau.High-temperature true triaxial compression tests are performed on the samples using a self-developed testing device with five different loading directions and three temperature values that are representative of the geological conditions of the deep underground tunnels in the region.Effect of temperature and loading direction on the strength,elastic modulus,Poisson’s ratio,and failure mode are analyzed.The method for quantitative identification of anisotropic failure is also proposed.The anisotropic mechanical behaviors of the gneiss granite are very sensitive to the changes in loading direction and temperature under true triaxial compression,and the high temperature seems to weaken the inherent anisotropy and stress-induced deformation anisotropy.The strength and deformation show obvious thermal degradation at 200℃due to the weakening of friction between failure surfaces and the transition of the failure pattern in rock grains.In the range of 25℃ 200℃,the failure is mainly governed by the loading direction due to the inherent anisotropy.This study is helpful to the in-depth understanding of the thermal-mechanical behavior of anisotropic rocks in deep underground projects.展开更多
Experimental results of 29 axially loaded fiber-reinforced polymer sheet (FS) confined concrete columns and two reference plain concrete columns are introduced. Twenty four column specimens were confined with carbon f...Experimental results of 29 axially loaded fiber-reinforced polymer sheet (FS) confined concrete columns and two reference plain concrete columns are introduced. Twenty four column specimens were confined with carbon fiber sheet (CFS) and five column specimens were hybrid confined with both CFS and glass fiber sheet (GFS). The influence of aspect ratio, FS material, initial axial force ratio, and FS confine-ment degree on the strength and deformation of columns were studied. Based on the experimental results, the equations of complete stress-strain curve of CFS confined concrete are proposed. These equations are suitable for the nonlinear analysis of square and rectangular section columns. Suggestions of applying FS to confine concrete columns are presented.展开更多
In order to study the strength failure and crack coalescence characteristics of cracked rocks, uniaxial compression experiments were conducted on cylindrical sandstone specimens, sampled from Longyou Grottoes of Zheji...In order to study the strength failure and crack coalescence characteristics of cracked rocks, uniaxial compression experiments were conducted on cylindrical sandstone specimens, sampled from Longyou Grottoes of Zhejiang Province, China, with a single pre-cut crack soaking in different chemical solutions. Based on the results of uniaxial compressive test under different chemical solutions and velocities of flow, the effect of strength and deformation characteristics and main modes of crack coalescence for cracked rocks under chemical corrosion were analyzed. The results show that the pH value and velocity of the chemical solutions both have great influence on the sandstone sample's uniaxial compressive strength and deformation characteristics. Cracked sandstone samples are tension-destructed under uniaxial compression, and the crack propagation directions are consistent with the loading direction. The phenomena of crack initiation, propagation and coalescence of sandstone are well observed. Four different crack types are identified based on the crack propagation mechanism by analyzing the ultimate failure modes of sandstone containing a single pre-cut fissure. The failure process of specimen in air is similar with the specimen under chemical solutions, however, the initial time of crack occuring in specimen under chemical solutions is generally earlier than that in the natural specimen, and the crack propagation and coalescence process of specimen under chemical solutions are longer than those of the natural specimen due to softening of structure of rock caused by hydro-chemical action. Immersion velocity of flow and chemical solutions does not have influence on the ultimate modes of crack coalescence.展开更多
To accurately predict coal burst hazards and estimate the failure of coal pillars in underground coal mining systems,it is of great significance to understand the mechanical behavior of coal-rock bimaterial composite ...To accurately predict coal burst hazards and estimate the failure of coal pillars in underground coal mining systems,it is of great significance to understand the mechanical behavior of coal-rock bimaterial composite structures.This paper presents experimental and numerical investigations on the response of rock-coal,coal-rock,and rock-coal-rock bimaterial composite structures under triaxial compression.The triaxial compression experiments are conducted under confining pressures in the range of 0-20 MPa.The resulting inside fracture networks are detected using X-ray-based computed tomography(CT).The experimentally observed data indicate that the mechanical parameters of the rock-coalrock composites are superior to those of the rock-coal and coal-rock combinations.After compression failure,the coal-rock combination specimens are analyzed via X-ray CT.The results display that the failure of the coal-rock composite bodies primarily takes place within the coal.Further,the bursting proneness is reduced by increasing confining pressure.Subsequently,the corresponding numerical simulations of the experiments are carried out by using the particle flow code.The numerical results reveal that coal is vulnerable with regard to energy storage and accumulation.展开更多
Complete bearing spiral case has not been applied to large power stations in China so far. The proposal of applying complete bearing spiral case necessitates an analysis of the reliability of the spiral case structure...Complete bearing spiral case has not been applied to large power stations in China so far. The proposal of applying complete bearing spiral case necessitates an analysis of the reliability of the spiral case structure and the security of units under various working conditions. In combination with practice of a project, this paper presents a three-dimensional nonlinear finite element static analysis of the concrete using a concrete smeared crack model by means of the well-known finite element method (FEM) software ABAQUS. The stress distribution of the spiral case and reinforcing bars, the range of damages in surrounding concrete, and the displacement of structure are quantified. The computational results indicate that the embedment method ensures the structure's safety in strength. At the same time, the result shows that this embedment is a kind of preponderant method for embedment in aspects of economy and technique of construction, and the application of this embedment method to the hydropower station is feasible provided that some proper engineering measures are taken to constrain the width of the concrete in accord with the code's requirements. The paper proves the security and reliability of the structural design of spiral case in hydropower station accordingly.展开更多
基金This work was supported by Natural Science Foundation of China(Grant No.52278333)the Fundamental Research Funds for the Central Universities(Grant No.N2101021)The work is under the framework of the 111 Project(Grant No.B17009)and Sino-Franco Joint Research Laboratory on Multiphysics and Multiscale Rock Mechanics.
文摘The anisotropic mechanical behavior of rocks under high-stress and high-temperature coupled conditions is crucial for analyzing the stability of surrounding rocks in deep underground engineering.This paper is devoted to studying the anisotropic strength,deformation and failure behavior of gneiss granite from the deep boreholes of a railway tunnel that suffers from high tectonic stress and ground temperature in the eastern tectonic knot in the Tibet Plateau.High-temperature true triaxial compression tests are performed on the samples using a self-developed testing device with five different loading directions and three temperature values that are representative of the geological conditions of the deep underground tunnels in the region.Effect of temperature and loading direction on the strength,elastic modulus,Poisson’s ratio,and failure mode are analyzed.The method for quantitative identification of anisotropic failure is also proposed.The anisotropic mechanical behaviors of the gneiss granite are very sensitive to the changes in loading direction and temperature under true triaxial compression,and the high temperature seems to weaken the inherent anisotropy and stress-induced deformation anisotropy.The strength and deformation show obvious thermal degradation at 200℃due to the weakening of friction between failure surfaces and the transition of the failure pattern in rock grains.In the range of 25℃ 200℃,the failure is mainly governed by the loading direction due to the inherent anisotropy.This study is helpful to the in-depth understanding of the thermal-mechanical behavior of anisotropic rocks in deep underground projects.
基金Supported by the National Natural Science Foundation of China (No. 50238030)
文摘Experimental results of 29 axially loaded fiber-reinforced polymer sheet (FS) confined concrete columns and two reference plain concrete columns are introduced. Twenty four column specimens were confined with carbon fiber sheet (CFS) and five column specimens were hybrid confined with both CFS and glass fiber sheet (GFS). The influence of aspect ratio, FS material, initial axial force ratio, and FS confine-ment degree on the strength and deformation of columns were studied. Based on the experimental results, the equations of complete stress-strain curve of CFS confined concrete are proposed. These equations are suitable for the nonlinear analysis of square and rectangular section columns. Suggestions of applying FS to confine concrete columns are presented.
基金Projects(10472130,41202225) supported by the National Natural Science Foundation of China
文摘In order to study the strength failure and crack coalescence characteristics of cracked rocks, uniaxial compression experiments were conducted on cylindrical sandstone specimens, sampled from Longyou Grottoes of Zhejiang Province, China, with a single pre-cut crack soaking in different chemical solutions. Based on the results of uniaxial compressive test under different chemical solutions and velocities of flow, the effect of strength and deformation characteristics and main modes of crack coalescence for cracked rocks under chemical corrosion were analyzed. The results show that the pH value and velocity of the chemical solutions both have great influence on the sandstone sample's uniaxial compressive strength and deformation characteristics. Cracked sandstone samples are tension-destructed under uniaxial compression, and the crack propagation directions are consistent with the loading direction. The phenomena of crack initiation, propagation and coalescence of sandstone are well observed. Four different crack types are identified based on the crack propagation mechanism by analyzing the ultimate failure modes of sandstone containing a single pre-cut fissure. The failure process of specimen in air is similar with the specimen under chemical solutions, however, the initial time of crack occuring in specimen under chemical solutions is generally earlier than that in the natural specimen, and the crack propagation and coalescence process of specimen under chemical solutions are longer than those of the natural specimen due to softening of structure of rock caused by hydro-chemical action. Immersion velocity of flow and chemical solutions does not have influence on the ultimate modes of crack coalescence.
基金This study was financially supported by Beijing Outstanding Young Scientist Program(BJJWZYJH01201911413037)National Natural Science Foundation of China(41877257+3 种基金5162240452009131)Shaanxi Coal Group Key Project(2018SMHKJ-A-J-03)Yueqi outstanding scholar Award Program by CUMTB。
文摘To accurately predict coal burst hazards and estimate the failure of coal pillars in underground coal mining systems,it is of great significance to understand the mechanical behavior of coal-rock bimaterial composite structures.This paper presents experimental and numerical investigations on the response of rock-coal,coal-rock,and rock-coal-rock bimaterial composite structures under triaxial compression.The triaxial compression experiments are conducted under confining pressures in the range of 0-20 MPa.The resulting inside fracture networks are detected using X-ray-based computed tomography(CT).The experimentally observed data indicate that the mechanical parameters of the rock-coalrock composites are superior to those of the rock-coal and coal-rock combinations.After compression failure,the coal-rock combination specimens are analyzed via X-ray CT.The results display that the failure of the coal-rock composite bodies primarily takes place within the coal.Further,the bursting proneness is reduced by increasing confining pressure.Subsequently,the corresponding numerical simulations of the experiments are carried out by using the particle flow code.The numerical results reveal that coal is vulnerable with regard to energy storage and accumulation.
基金Supported by the Sustentation Plan Projects for Out-standing Young Teachers of the Ministry of Education (20011879)
文摘Complete bearing spiral case has not been applied to large power stations in China so far. The proposal of applying complete bearing spiral case necessitates an analysis of the reliability of the spiral case structure and the security of units under various working conditions. In combination with practice of a project, this paper presents a three-dimensional nonlinear finite element static analysis of the concrete using a concrete smeared crack model by means of the well-known finite element method (FEM) software ABAQUS. The stress distribution of the spiral case and reinforcing bars, the range of damages in surrounding concrete, and the displacement of structure are quantified. The computational results indicate that the embedment method ensures the structure's safety in strength. At the same time, the result shows that this embedment is a kind of preponderant method for embedment in aspects of economy and technique of construction, and the application of this embedment method to the hydropower station is feasible provided that some proper engineering measures are taken to constrain the width of the concrete in accord with the code's requirements. The paper proves the security and reliability of the structural design of spiral case in hydropower station accordingly.