期刊文献+
共找到127篇文章
< 1 2 7 >
每页显示 20 50 100
Substation clustering based on improved KFCM algorithm with adaptive optimal clustering number selection
1
作者 Yanhui Xu Yihao Gao +4 位作者 Yundan Cheng Yuhang Sun Xuesong Li Xianxian Pan Hao Yu 《Global Energy Interconnection》 EI CSCD 2023年第4期505-516,共12页
The premise and basis of load modeling are substation load composition inquiries and cluster analyses.However,the traditional kernel fuzzy C-means(KFCM)algorithm is limited by artificial clustering number selection an... The premise and basis of load modeling are substation load composition inquiries and cluster analyses.However,the traditional kernel fuzzy C-means(KFCM)algorithm is limited by artificial clustering number selection and its convergence to local optimal solutions.To overcome these limitations,an improved KFCM algorithm with adaptive optimal clustering number selection is proposed in this paper.This algorithm optimizes the KFCM algorithm by combining the powerful global search ability of genetic algorithm and the robust local search ability of simulated annealing algorithm.The improved KFCM algorithm adaptively determines the ideal number of clusters using the clustering evaluation index ratio.Compared with the traditional KFCM algorithm,the enhanced KFCM algorithm has robust clustering and comprehensive abilities,enabling the efficient convergence to the global optimal solution. 展开更多
关键词 Load substation clustering Simulated annealing genetic algorithm Kernel fuzzy C-means algorithm Clustering evaluation
下载PDF
Experimental investigation and analytically modeling of hysteretic behavior of rigid bus-flexible connectors of 220 kV electrical substations
2
作者 Tang Tingxuan He Jun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第3期841-852,共12页
This paper describes the quasi-static testing and analytical modelling of the hysteretic behavior of aluminum alloy rigid bus-flexible connectors of 220 kV electrical substations.The main objective of the study is to ... This paper describes the quasi-static testing and analytical modelling of the hysteretic behavior of aluminum alloy rigid bus-flexible connectors of 220 kV electrical substations.The main objective of the study is to experimentally investigate the hysteretic behavior of six different types of rigid bus-flexible connectors 220 kV electrical substations when subjected to cyclic loading.Another objective is to theoretically study the flexibility and effectiveness of a previously proposed analytical model in fitting the experimental hysteresis loops of the tested rigid bus-flexible connectors.The experimental investigation indicates that the tested rigid bus-flexible connectors exhibit highly asymmetric hysteresis behavior along with tension stiffening effect.The theoretical study demonstrates that the generalized Bouc-Wen model has high flexibility and is effective in fitting the experimental hysteresis resisting force-displacement curves of the six tested rigid bus-flexible connectors. 展开更多
关键词 rigid bus-flexible connectors 220 kV electrical substations hysteretic behavior experimental curves analytical model
下载PDF
Modeling and Simulation of a Transmission Line Response to a 400 kV/400V Capacitor Coupled Substation
3
作者 Sinqobile Wiseman Nene Bolanle Tolulope Abe Agha Francis Nnachi 《Journal of Power and Energy Engineering》 2023年第12期1-14,共14页
The access to electricity in rural areas is extremely limited, but it is crucial for all citizens. The population in rural areas of sub-Saharan African (SSA) countries is generally low, making it economically unfeasib... The access to electricity in rural areas is extremely limited, but it is crucial for all citizens. The population in rural areas of sub-Saharan African (SSA) countries is generally low, making it economically unfeasible to implement traditional rural electrification (CRE) projects due to the high cost of establishing the necessary distribution infrastructure. To address this cost issue, one alternative technology for rural electrification (URE) that can be explored is the Capacitor Coupled Substation (CCS) technology. CCS is a cost-effective solution for supplying electricity to rural areas. The research is necessitated by the need to offer a cost-effective technology for supplying electricity to sparsely populated communities. This paper examines the impact on the transmission network when a 400 kV/400V CCS is connected to it. The system response when a CCS is connected to the network was modeled using MATLAB/Si-mulink. The results, based on the fixed load of 80 kW, showed negligible interference on the transmission line voltage. However, there was minor impact on the parameters downstream of the tapping point. These findings were further supported by introducing a fault condition to the CCS, which showed that interferences with the CCS could affect the overall stability of the transmission network downstream of the tapping node, similar to the behavior of an unstable load. 展开更多
关键词 Capacitor Coupled substation Conventional Rural Electrification Unconventional Rural Electrification Transmission Line Behavior Power System Simulation
下载PDF
Intelligent Detection Method of Substation Environmental Targets Based on MD-Yolov7
4
作者 Tao Zhou Qian Huang +1 位作者 Xiaolong Zhang Yong Zhang 《Journal of Intelligent Learning Systems and Applications》 2023年第3期76-88,共13页
The complex operating environment in substations, with different safety distances for live equipment, is a typical high-risk working area, and it is crucial to accurately identify the type of live equipment during aut... The complex operating environment in substations, with different safety distances for live equipment, is a typical high-risk working area, and it is crucial to accurately identify the type of live equipment during automated operations. This paper investigates the detection of live equipment under complex backgrounds and noise disturbances, designs a method for expanding lightweight disturbance data by fitting Gaussian stretched positional information with recurrent neural networks and iterative optimization, and proposes an intelligent detection method for MD-Yolov7 substation environmental targets based on fused multilayer feature fusion (MLFF) and detection transformer (DETR). Subsequently, to verify the performance of the proposed method, an experimental test platform was built to carry out performance validation experiments. The results show that the proposed method has significantly improved the performance of the detection accuracy of live devices compared to the pairwise comparison algorithm, with an average mean accuracy (mAP) of 99.2%, which verifies the feasibility and accuracy of the proposed method and has a high application value. 展开更多
关键词 substation Target Detection Deep Learning Multi-Layer Feature Fusion Unmanned Vehicles
下载PDF
Design Of MV/LV Substation Transformer 被引量:1
5
作者 Sabir MESSALTI Fares Zitouni Issam Griche 《Engineering(科研)》 2013年第1期20-25,共6页
A substation is a part of an electrical generation, transmission, and distribution system. Substations generally have switching, protection and control equipment, and transformers. The low voltage distribution network... A substation is a part of an electrical generation, transmission, and distribution system. Substations generally have switching, protection and control equipment, and transformers. The low voltage distribution networks are supplied from MV/LV substation transformer that represent the last step of bringing transformation to the? low voltage and ensuring the? protection and monitoring of the network. There are three types of MV/LV substation: pole-mounted transformer substation, the substation in an envelope and substation in masonry. This paper presents a general description for different MV/LV substation and a methodology to design the various elements making up the public distribution substation (choice of the emplacement, engineering, power transformer, choice of MV cells, circuit breakers, fuses, disconnect? switch, conductors,...etc). 展开更多
关键词 substation TRANSFORMER MV cells substation in MASONRY pole-mounted TRANSFORMER substation.
下载PDF
Research on Communication Network Configuration and Simulation of Smart Substation Based on Ethernet 被引量:2
6
作者 Jingxia Liu Xuerang Zhang Fuquan Zhang 《Energy and Power Engineering》 2020年第4期14-24,共11页
The characters of the intelligent substation communication network structure are analyzed in the paper. Combining existing integrated automation substation hardware circuit and VLAN (Virtual Local Area Network) resear... The characters of the intelligent substation communication network structure are analyzed in the paper. Combining existing integrated automation substation hardware circuit and VLAN (Virtual Local Area Network) research foundation to optimize the network configuration. In accordance with IEC61850 standard, the network is partitioned into several VLANs based on the Tag VLAN division method of ID address. Real-time communication packets between GOOSE networks, SV (sampling information) networks, and switches use 802.1Q protocol headers to distinguish these packets. Finally, OPNET simulation software was used to simulate and verify the simplified dual-star topology. The results demonstrate that the delay and traffic bandwidth meet the requirements of actual substation operation standards. Compared with ordinary single-star networks, the reliability is greatly improved and the effectiveness is improved. 展开更多
关键词 Intelligent substation Network Configuration VLAN DIVISION GOOSE and SV OPNET
下载PDF
Maximum Inner Product Method for Extracting the Path-Loss Parameters in Primary Transformer Substations 被引量:1
7
作者 Qiang Li Hongxin Zhang +2 位作者 Tianyi Zheng Xueli Wang Yinghua Lv 《China Communications》 SCIE CSCD 2019年第4期120-129,共10页
In order to deploy short-range wireless communication devices in the primary transformer substation, a Maximum Inner Product(MIP) Method is proposed to extract the path-loss parameters in 110 kV and 220 kV primary tra... In order to deploy short-range wireless communication devices in the primary transformer substation, a Maximum Inner Product(MIP) Method is proposed to extract the path-loss parameters in 110 kV and 220 kV primary transformer substations. The maximum inner product of the testing data is calculated to find out the loss index n and the standard deviation σ, and then the pathloss models can be set up. By comparing the MIP with Minimum Mean Square estimation(MMSE) and Cumulative Sum(CUSUM), MIP can match the measured values best. In order to apply the MIP path-loss model, under the initial signal to noise ratio(SNR) at 5 dB and 10 dB, a ZigBee simulation system is constructed to validate the situation that bit error rate(BER) varies with distance. And the ZigBee devices with 5 units are tested in a 220 kV primary transformer substation. The result of the test proves that the path-loss model is accurate. 展开更多
关键词 PRIMARY transformer substation path-loss ZigBee
下载PDF
Effect Evaluation and Intelligent Prediction of Power Substation Project Considering New Energy 被引量:1
8
作者 Huiying Wu Meihua Zou +3 位作者 Ye Ke Wenqi Ou Yonghong Li Minquan Ye 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第9期739-761,共23页
The evaluation of the implementation effect of the power substation project can find out the problems of the project more comprehensively,which has important practical significance for the further development of the p... The evaluation of the implementation effect of the power substation project can find out the problems of the project more comprehensively,which has important practical significance for the further development of the power substation project.To ensure accuracy and real-time evaluation,this paper proposes a novel hybrid intelligent evaluation and prediction model based on improved TOPSIS and Long Short-Term Memory(LSTM)optimized by a Sperm Whale Algorithm(SWA).Firstly,under the background of considering the development of new energy,the influencing factors of power substation project implementation effect are analyzed from three aspects of technology,economy and society.Moreover,an evaluation model based on improved TOPSIS is constructed.Then,an intelligent prediction model based on SWA optimized LSTM is designed.Finally,the scientificity and accuracy of the proposed model are verified by empirical analysis,and the important factors affecting the implementation effect of power substation projects are pointed out. 展开更多
关键词 New energy substation implementation effect evaluation and intelligent prediction improved topsis LSTM SWA
下载PDF
Research on Distribution of Electromagnetic Environment around Substations and Optimization Layout of On-line Monitoring 被引量:1
9
作者 Li Peiming Xiao Jun Wang Wenjin 《Meteorological and Environmental Research》 CAS 2019年第6期60-63,共4页
The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating... The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating monitoring points suitable for an on-line monitoring system of electromagnetic environment was proposed. 展开更多
关键词 ON-LINE monitoring ELECTROMAGNETIC ENVIRONMENT substation Optimization layout
下载PDF
An Algorithm for Optimal Firewall Placement in IEC61850 Substations 被引量:2
10
作者 Hermes Eslava Luis Alejandro Rojas Danny Pineda 《Journal of Power and Energy Engineering》 2015年第4期16-22,共7页
Recently, most electric power substations have adopted production control systems, such as SCADA systems, which communicate with field devices and remotely control processes from a computer screen. However, these syst... Recently, most electric power substations have adopted production control systems, such as SCADA systems, which communicate with field devices and remotely control processes from a computer screen. However, these systems together with protection measures and additional control actions (using protocol IEC61850) seem not to be enough to free substations of security attacks (e.g. virus, intruders, forgery or unauthorized data manipulation). This paper analyzes the main features of an electric power substation together with the aspects that might be significantly affected by cyber-attacks. The paper also presents the implementation of a specific security system (i.e. firewall-wise system) intended to protect a target distribution network. 展开更多
关键词 FIREWALL SECURITY substationS ELECTRIC Power IEC61850
下载PDF
An Investigation into Substation Grounding and Its Implementation on Gaza Substation 被引量:1
11
作者 Ahmed Hammuda Hassan Nouri Mohammed Saleh Al-Ayoubi 《Energy and Power Engineering》 2011年第5期593-599,共7页
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiven... An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study. Through modelling and simulating the power station in Gaza while considering some field data, an optimal substation grounding grid has been designed and has shown complete conformance to safety. It is thus considered that such a design will protect personnel in any area of the substation in addition to the installed machinery if the largest possible fault current was to traverse the earth. 展开更多
关键词 GAZA GROUNDING Grid Ground Resistance substation STEP VOLTAGE TOUCH VOLTAGE
下载PDF
Comparative Study on Substation Shielding Due to Direct Lightning Strokes 被引量:1
12
作者 Ab Halim Abu Bakar Chia Kwang Tan +3 位作者 Alyaa Zainal Abidin Pang Jack Khai Hazlie Mokhlis Hazlee Azil Illias 《Journal of Power and Energy Engineering》 2014年第4期600-611,共12页
Malaysia is one of the many countries that experience high lightning related activities. In fact, according to Malaysian Meteorological Department the Ground Flash Density (GFD) in Malaysia, it is rated at the fifth p... Malaysia is one of the many countries that experience high lightning related activities. In fact, according to Malaysian Meteorological Department the Ground Flash Density (GFD) in Malaysia, it is rated at the fifth place in the ten most lightning cities of the world, with a high keraunic level, which is 240 thunderstorm days per year, and in other words, a Ground Flash Density (GFD) of 48.3 flashes per square kilometer per year. In the power systems, high keraunic level would contribute to high possibility of power interruptions such as disruption, degradation, damage and downtime. These outages would ultimately lead to revenue losses and reduction of network reliability. These lightning related interruptions may be in terms of direct lightning strikes to the lines or to the equipments in the substation. By the use of Mat Lab GUI (Graphic Users Interface), this study presents a simple computer program which uses the electro-geometric model (EGM) for the designing of substation shielding systems. The EGM uses the concept where the protection zone of a lightning system lies within the radius where the upward channel initiates and propagates through the air terminal to meet the downward leader. This interception point is called “the point of discrimination” and is where the downward leader decides its final jump. The distance at which the last jump occurs is known as the striking distance. With the use of the striking distance and the mathematical equations developed by Young, Brown-Whitehead, IEEE-1992 (IEEE T&D Committee Equations) and IEEE-1995 (IEEE Substations Committee Equations). This project aimed to investigate, understand and analyse the substation protection by means of masts and shield wires. The analysis is extended to account for lightning protection provided by single mast to two masts as well as from single shield wire to double shielding wires. The outcomes of these four equations will be compared. 展开更多
关键词 LIGHTNING Electro-Geometric Model Striking DISTANCE substation PROTECTION LIGHTNING PROTECTION MATLAB
下载PDF
Research on Reliability of Relaying Protection in Smart Substation 被引量:1
13
作者 Kai Wang Wanqing Li 《World Journal of Engineering and Technology》 2019年第2期333-338,共6页
Research on reliability of relaying protection in smart substation not only has a positive effect on the rational configuration scheme of relaying protection in smart substation, but also can promote the stability and... Research on reliability of relaying protection in smart substation not only has a positive effect on the rational configuration scheme of relaying protection in smart substation, but also can promote the stability and safety of the overall operation of power system. There are many reliability strategies for relaying protection in smart substation. In practice, the key points of relaying protection should be clarified. Based on the reality, the protection configuration should be strengthened;the voltage limited delay should be used for protection, and the protection configuration scheme of actual lines should be paid attention to, so as to improve the reliability of relaying protection in smart substation and promote the realization of stable and sustainable development of power system and smart substation. 展开更多
关键词 SMART substation RELAYING PROTECTION RELIABILITY
下载PDF
Development of IEC61850 Based Substation Engineering Tools with IEC61850 Schema Library 被引量:1
14
作者 Yong Hak Kim Jeon Yeol Han +2 位作者 You Jin Lee Yong Ho An In Jun Song 《Smart Grid and Renewable Energy》 2011年第3期271-277,共7页
IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are... IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are required combined with new skills across the substation engineering. In order to construct the IEC 61850 based substation automation system, the IED engineering tools as an engineering means are necessary to cope with the substation automation by full digital devices in the real power systems. Compared the configuration tools provided IEDs vendors which are able to support the operation and communication analysis between IEDs, the XML based IED integration engineering tools as substation engineering tools which are developed can build, edit and save the ICD, SCL and CID files. Particularly, the substation engineering tools are possible to apply the IEC 61850 based IEDs for the engineering process of systems and also provide the reliability and efficiency of system for the utilities and manufacturers. The developed tools are applied to test and create the SCL files for domestic-made IEDs, and then compared with the conventional tools. The reliability including accuracy of results was proved. 展开更多
关键词 IEC 61850 substation ENGINEERING TOOLS IEC 61850 SCHEMA LIBRARY substation Automation System
下载PDF
Research on the Process Layer and Substation Layer Relay Protection in Smart Substation Relay Protection 被引量:1
15
作者 Kong Haibo Xie Xiaodong +2 位作者 Wang Lingfei Sun Peng Xu Bing 《Journal of Electronic Research and Application》 2018年第1期35-42,共8页
The intelligent substation relay protection facility is a fundamental element in construction of modern power system,based on the principles of flexibility,security and accuracy,and it can be divided into process laye... The intelligent substation relay protection facility is a fundamental element in construction of modern power system,based on the principles of flexibility,security and accuracy,and it can be divided into process layer and substation layer according to specific equipment.The former is suitable for individual sampling of disposable equipment,can be separated from the base station synchronization sampling,with the help of synchronous digital system and ping-pong algorithm to achieve synchronization of the overall sampling,that is to take the distribution protection components,through the separate transmission medium to realize the information transmission;the latter is for variable power plant components centralized backup protection,taking online real-time tuning technique. 展开更多
关键词 lectric POWER system INTELLIGENT substation RELAY PROTECTION
下载PDF
The Configuration and Communication of Integrated Substation Automation Systems 被引量:1
16
作者 Huang Jian Zhu Daxin (Nanjing Automation Research Institute) 《Electricity》 1998年第4期45-49,共5页
Based on a discussion of the feature of a substation, the paper presents the concept that a substation is composed of basic units (BC). The hardware structure of the IED of a BC is described. Next, the paper discusses... Based on a discussion of the feature of a substation, the paper presents the concept that a substation is composed of basic units (BC). The hardware structure of the IED of a BC is described. Next, the paper discusses the communication mode of the current Integrated Substation Automation Systems(ISA) and describes the hardware structre and the functions of the ISA with fieldbus. At last the paper presents trends in the development of ISA. 展开更多
关键词 substation AUTOMATION COMMUNICATION FIELDBUS
下载PDF
A Maintenance Optimzation Policy for an Electric Power Distribution System: Case of the HV/MV Substations 被引量:1
17
作者 Morad Mahmoudi Abdellah El Barkany Ahmed El Khalfi 《Engineering(科研)》 2014年第5期236-253,共18页
Today, in the modern era, and under the pressure of rapid development around the kingdom regions, electric utilities are confronted with a myriad of challenges that include aging infrastructure, enhanced expectation o... Today, in the modern era, and under the pressure of rapid development around the kingdom regions, electric utilities are confronted with a myriad of challenges that include aging infrastructure, enhanced expectation of reliability, reduced cost, and coping effectively with uncertainties and changing regulation requirements. Indeed, for distribution systems, HV/MV substations represent a complex and critical physical asset that requires a careful evaluation of their maintenance practices aiming at more cost-effective tasks. The first concern of the electric power distribution company in Morocco is the optimization of the distribution network maintenance scheduling, to minimize system operating costs and ensure that the system is running most economically. There is significant pressure on power providers for greater system reliability and improvement of customer satisfaction, while similar emphasis is placed on cost reduction. These cost reductions focus on reducing operating and maintenance expenses, and minimizing investments in new plants and equipment. However, the present of the electricity distribution, influenced by a number of technical restrictions and strict regulatory requirements to meet, leads distribution utilities to search new ways of optimizing the maintenance management, make an effort to maximize profit by reducing their electricity supply and operation costs while maintaining their reliability, developing more effective activities, with lower costs. Furthermore, maximal HV/MV substation asset value and minimal maintenance cost are typical economic objectives of the electric utilities. The optimization of maintenance is one possible technique to reduce maintenance costs while improving reliability and utilities need to implement new strategies for more effective maintenance techniques and Asset Management (AM) methods programs to manage inspections and maintenance activities in order to control HV/MV substation equipment conditions. However, development of strategies to make sound decisions in order to effectively improve equipment and system reliability while meeting constraints such as a maintenance budget is a challenge. Finally, this paper describes the application of a new approach based Reliability Centered Maintenance (RCM) methodology to optimize maintenance resources and to the development of maintenance plan for HV/MV distribution substations. For this purpose, a case study was performed on the equipment of power distribution systems for the benefit of a holding company (ONEE Electricity Distribution) in Morocco. The present study was conducted in Oujda Exploitation Maintenance Service (OEXMS), in charge of operation and maintenance of distribution networks. 展开更多
关键词 HV/MV Distribution substationS Maintenance Strategy RCM Optimization ASSET Management
下载PDF
China’s Three Gorges Reservoir Area of Intelligent Substation Project Supervision Work Method Is Discussed in This Paper 被引量:1
18
作者 Haoran Xiong 《Journal of Power and Energy Engineering》 2016年第2期27-36,共10页
The ecological environment promotes the construction of smart grids, while the smart substation is the key to the construction of smart grids. Based on the supervision of the Zigui 220 KV smart substation project in t... The ecological environment promotes the construction of smart grids, while the smart substation is the key to the construction of smart grids. Based on the supervision of the Zigui 220 KV smart substation project in the Three Gorges Reservoir Region of China, this paper studies how to well create the supervision for the smart substation project construction. With the research focus of “four-control, two-management and one-coordination” in the supervision and according to the problems and experience in the project construction, some reasonable suggestions are put forward, and then the accumulated methods and experience by supervisors when they are engaged in the supervision for the smart substation project construction are summarized. 展开更多
关键词 Ecological Environment Smart Grids Smart substation Project Supervision
下载PDF
Fair hierarchical clustering of substations based on Gini coefficient
19
作者 Dajun Si Wenyue Hu +1 位作者 Zilin Deng Yanhui Xu 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期576-586,共11页
For the load modeling of a large power grid,the large number of substations covered by it must be segregated into several categories and,thereafter,a load model built for each type.To address the problem of skewed clu... For the load modeling of a large power grid,the large number of substations covered by it must be segregated into several categories and,thereafter,a load model built for each type.To address the problem of skewed clustering tree in the classical hierarchical clustering method used for categorizing substations,a fair hierarchical clustering method is proposed in this paper.First,the fairness index is defined based on the Gini coefficient.Thereafter,a hierarchical clustering method is proposed based on the fairness index.Finally,the clustering results are evaluated using the contour coefficient and the t-SNE two-dimensional plane map.The substations clustering example of a real large power grid considered in this paper illustrates that the proposed fair hierarchical clustering method can effectively address the problem of the skewed clustering tree with high accuracy. 展开更多
关键词 Load modeling substation clustering Gini coefficient Hierarchical clustering Contour coefficient
下载PDF
Automatic infrared image recognition method for substation equipment based on a deep self-attention network and multi-factor similarity calculation
20
作者 Yaocheng Li Yongpeng Xu +4 位作者 Mingkai Xu Siyuan Wang Zhicheng Xie Zhe Li Xiuchen Jiang 《Global Energy Interconnection》 EI CAS CSCD 2022年第4期397-408,共12页
Infrared image recognition plays an important role in the inspection of power equipment.Existing technologies dedicated to this purpose often require manually selected features,which are not transferable and interpret... Infrared image recognition plays an important role in the inspection of power equipment.Existing technologies dedicated to this purpose often require manually selected features,which are not transferable and interpretable,and have limited training data.To address these limitations,this paper proposes an automatic infrared image recognition framework,which includes an object recognition module based on a deep self-attention network and a temperature distribution identification module based on a multi-factor similarity calculation.First,the features of an input image are extracted and embedded using a multi-head attention encoding-decoding mechanism.Thereafter,the embedded features are used to predict the equipment component category and location.In the located area,preliminary segmentation is performed.Finally,similar areas are gradually merged,and the temperature distribution of the equipment is obtained to identify a fault.Our experiments indicate that the proposed method demonstrates significantly improved accuracy compared with other related methods and,hence,provides a good reference for the automation of power equipment inspection. 展开更多
关键词 substation equipment Infrared image intelligent recognition Deep self-attention network Multi-factor similarity calculation
下载PDF
上一页 1 2 7 下一页 到第