This paper presents a modeling method by stochastic Petri net for reliability analysis of phased mission system( PMS) with phase backup. The model consisting of petri nets,depicts the system behaviors of unit level,sy...This paper presents a modeling method by stochastic Petri net for reliability analysis of phased mission system( PMS) with phase backup. The model consisting of petri nets,depicts the system behaviors of unit level,system logic level and phase level. Guard functions of petri nets are used to avoid modeling complexity and make the model flexible to different reliability logical structures. It was shown that the time redundancy within phase and from phase backup for PMS can both be described by use of the proposed model.展开更多
By using wireless communication technology, when wired network of grassroots station is failure, wireless backup system of meteorological data transmission can automatically switch, and transmit the data at the statio...By using wireless communication technology, when wired network of grassroots station is failure, wireless backup system of meteorological data transmission can automatically switch, and transmit the data at the station with line fault to the destination by short message way. The system has simple operation and low operation cost, and transmission fault of real-time meteorological data due to line problem at the station can be effectively decreased. At present, the system has been tested successfully and put into business operation.展开更多
As the computer system has developed much in this highly information-oriented society, database security has become a very important problem and its backup strategies need to be made more efficiently and safety. The i...As the computer system has developed much in this highly information-oriented society, database security has become a very important problem and its backup strategies need to be made more efficiently and safety. The image copy method has been used as the most simple and dependable recovery mechanism for media failure. However, this method spends high overhead costs for massive data transmission and much processing time in the normal operation of the database. To cover such weak points, incremental and full backup methods are adopted before updated trucks reach a predetermined level. Moreover, when the number of full backup files exceeded a predetermined level, we stop incremental and full backups and switch it to the image copy. This paper applies cumulative damage model to backup of files in a database system, by putting damage shock by update, failure shock by database failure and damage by dumped files, and considers the tradeoff among overhead costs of image copy and incremental, full backup methods, and discusses analytically an optimal policy for the image copy backup interval. Finally, numerical examples are given in the case of Poisson process and exponential distributions.展开更多
In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated qui...In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated quickly and defined exactly. In our study, global information will be introduced into the backup protection system. By analyzing and computing real-time PMU measurements, basing on cluster analysis theory, we are using mainly hierarchical cluster analysis to search after the statistical laws of electrical quantities' marked changes. Then we carry out fast and exact detection of fault components and fault sections, and finally accomplish fault isolation. The facts show that the fault detection of fault component (fault section) can be performed successfully by hierarchical cluster analysis and calculation. The results of hierarchical cluster analysis are accurate and reliable, and the dendrograms of hierarchical cluster analysis are in intuition.展开更多
基金Nationd Natural Science Foundation of China(No.71671185)
文摘This paper presents a modeling method by stochastic Petri net for reliability analysis of phased mission system( PMS) with phase backup. The model consisting of petri nets,depicts the system behaviors of unit level,system logic level and phase level. Guard functions of petri nets are used to avoid modeling complexity and make the model flexible to different reliability logical structures. It was shown that the time redundancy within phase and from phase backup for PMS can both be described by use of the proposed model.
文摘By using wireless communication technology, when wired network of grassroots station is failure, wireless backup system of meteorological data transmission can automatically switch, and transmit the data at the station with line fault to the destination by short message way. The system has simple operation and low operation cost, and transmission fault of real-time meteorological data due to line problem at the station can be effectively decreased. At present, the system has been tested successfully and put into business operation.
文摘As the computer system has developed much in this highly information-oriented society, database security has become a very important problem and its backup strategies need to be made more efficiently and safety. The image copy method has been used as the most simple and dependable recovery mechanism for media failure. However, this method spends high overhead costs for massive data transmission and much processing time in the normal operation of the database. To cover such weak points, incremental and full backup methods are adopted before updated trucks reach a predetermined level. Moreover, when the number of full backup files exceeded a predetermined level, we stop incremental and full backups and switch it to the image copy. This paper applies cumulative damage model to backup of files in a database system, by putting damage shock by update, failure shock by database failure and damage by dumped files, and considers the tradeoff among overhead costs of image copy and incremental, full backup methods, and discusses analytically an optimal policy for the image copy backup interval. Finally, numerical examples are given in the case of Poisson process and exponential distributions.
文摘In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated quickly and defined exactly. In our study, global information will be introduced into the backup protection system. By analyzing and computing real-time PMU measurements, basing on cluster analysis theory, we are using mainly hierarchical cluster analysis to search after the statistical laws of electrical quantities' marked changes. Then we carry out fast and exact detection of fault components and fault sections, and finally accomplish fault isolation. The facts show that the fault detection of fault component (fault section) can be performed successfully by hierarchical cluster analysis and calculation. The results of hierarchical cluster analysis are accurate and reliable, and the dendrograms of hierarchical cluster analysis are in intuition.