期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Lipid layer thickness and tear meniscus height measurements for the differential diagnosis of evaporative dry eye subtypes 被引量:9
1
作者 Xuan Sang Yan Li +8 位作者 Liu Yang Jia-Hui Liu Xiao-Ran Wang Chao-Yang Li Ying Liu Chen-Jie Wang Xiong-Jun He Shou-Bi Wang Zhi-Chong Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第9期1496-1502,共7页
AIM: To explore a new diagnostic index for differentiating the evaporative dry eye(EDE) subtypes by analysis of their respective clinical characteristics. METHODS: A cross-sectional study of 139 patients(139 eyes... AIM: To explore a new diagnostic index for differentiating the evaporative dry eye(EDE) subtypes by analysis of their respective clinical characteristics. METHODS: A cross-sectional study of 139 patients(139 eyes) with EDE who were enrolled and classified as obstructive meibomian gland dysfunction(MGD)(n=81) and non-obstructive MGD(n=58) EDE. All patients completed a Standard Patient Evaluation of Eye Dryness(SPEED) questionnaire and were evaluated for average lipid layer thickness(LLT), tear meniscus height measurements(TMH), tear break-up time(TBUT), ocular surface staining score, Schirmer I test(SIT), lid margin abnormalities, and meibomian gland function and morphology. RESULTS: Age, average LLT, TMH, scores of lid margin abnormalities, meibum quality, meibomian gland loss(MGL)(all P≤0.001), and TBUT(P=0.03) were all significantly different between obstructive MGD EDE patients and nonobstructive MGD EDE patients. Average LLT in obstructive MGD EDE was correlated with meibomian expressibility(r=-0.541, P≤0.001), lid margin abnormalities were marginally not significant(r=0.197, P=0.077), and TMH was correlated with MGL(total MGL: r=0.552, P≤0.001; upper MGL: r=0.438, P≤0.001; lower MGL: r=0.407, P≤0.001). Average LLT in non-obstructive MGD EDE, was correlated with meibomian expressibility and Oxford staining(r=-0.396, P=0.002; r=-0.461, P≤0.001). The efficiency of combining average LLT and TMH was optimal, with a sensitivity of 80.2% and a specificity of 74.1%. Obstructive MGD EDE patients had an average LLT≥69 nm and TMH≥0.25 mm, while non-obstructive MGD EDE patients had an average LLT〈69 nm and TMH〈0.25 mm.CONCLUSION: Obstructive MGD EDE and nonobstructive MGD EDE have significantly different clinical characteristics. Combining average LLT and TMH measurements enhanced their reliability for differentiating these two subtypes and provided guidance for offering more precise treatments for EDE subtypes. 展开更多
关键词 evaporative dry eye lipid layer thickness tear meniscus height
原文传递
Assessments of tear meniscus height, tear film thickness, and corneal epithelial thickness after deep anterior lamellar keratoplasty 被引量:2
2
作者 Wen-jia XIE Ye-sheng XU +1 位作者 Xia ZHANG Yu-feng YAO 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2018年第3期218-226,共9页
Objective: To assess the lower tear meniscus height(LTMH), central tear film thickness(CTFT), and central corneal epithelial thickness(CCET) after deep anterior lamellar keratoplasty(DALK). Methods: This was... Objective: To assess the lower tear meniscus height(LTMH), central tear film thickness(CTFT), and central corneal epithelial thickness(CCET) after deep anterior lamellar keratoplasty(DALK). Methods: This was a retrospective cross-sectional study of 20 patients who had DALK in one eye over a three-month period. LTMH, CTFT, and CCET of the operated eyes and the unoperated fellow eyes were measured using high-definition optical coherence tomography(HD-OCT). Correlations between three OCT assessments and age, time following surgery, graft size, bed size, and the number of residual sutures were analyzed. Results: Compared to patients with keratoconus, patients with other corneal conditions had significantly higher CCET in the fellow eye(P=0.024). For all patients, CCET in the operated eye was significantly negatively correlated with the number of residual sutures(R=-0.579, P=0.008), and was significantly positively correlated with time following surgery(R=0.636, P=0.003). In the fellow eye, a significant positive correlation was found between age and CCET(R=0.551, P=0.012), and a significant negative correlation between age and CTFT(R=-0.491, P=0.028). LTMH was found to be significantly correlated between operated and fellow eyes(R=0.554, P=0.011). There was no significant correlation between LTMH and age, bed/graft size, time following surgery, or residual sutures(all possible correlations, P0.05). Conclusions: Patients with keratoconus tend to have a thinner central corneal epithelium. Corneal epithelium keeps regenerating over time after DALK. DALK did not induce a significant change in tear volume compared with the fellow eye. Postoperative tear function might depend on an individual's general condition, rather than on age, gender, bed/graft size, time following surgery, or residual sutures. 展开更多
关键词 tear meniscus height Corneal epithelial thickness tear film Deep anterior lamellar keratoplasty (DALK) High-definition optical coherence tomography (HD-OCT) KERATOCONUS
原文传递
Assessment of tear film parameters post-treatment with commercial eyelid cleaning wipes:a pilot study
3
作者 Amal Aldarwesh Ali Almustanyir +7 位作者 Raied Fagehi Khalaf Alruways Abdulaziz Bin Turki Mansour Alghamdi Muteb Khalaf Alanazi Balsam Alabdulkader Wafa Alotaibi Mosaad Alhassan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期659-664,共6页
AIM:To investigate the short-term effects of commercially available eyelid-cleaning wipes on film parameters.METHODS:This study enrolled 48 healthy participants aged 20-35y(both males and females).Clinical assessment ... AIM:To investigate the short-term effects of commercially available eyelid-cleaning wipes on film parameters.METHODS:This study enrolled 48 healthy participants aged 20-35y(both males and females).Clinical assessment included the Ocular Surface Disease Index(OSDI)questionnaire,non-invasive tear break-up time(NITBUT),tear meniscus height(TMH),and lipid layer pattern(LLP).Based on these initial results,participants were categorized as either non-dry eye or dry eye.Participants in each group were randomly allocated to either Blephaclean■or Systane■treatments.Changes in NITBUT,TMH,and LLP levels before and after lid wipe treatment were assessed.RESULTS:The dry eye group exhibited significantly higher OSDI scores and lower NITBUT and TMH levels than in the non-dry eye group(P<0.001).Following the application of eyelid wipes(Systane■wipes),dry eye subjects experienced a significant improvement in NITBUT levels(P=0.0014)compared to the non-dry eye individuals.Although the remaining participants showed a marginal increase in TMH and NITBUT levels,these changes did not achieve statistical significance(P>0.05).Similarly,the LLP levels were significantly improved with Systane■(P<0.001)post-treatment compared to individuals in the non-dry eye group.However,the dry eye subjects showed higher posttreatment LLP levels than the untreated group(P<0.02).CONCLUSION:The short-term effects of Systane®eyelid wipes on tear film parameters suggest their effectiveness in dry eye disease.Nonetheless,further exploration of their long-term impact is essential to justify their cost effectiveness and efficacy in treating both aqueous deficiency and evaporative dryness. 展开更多
关键词 dry eye lid wipes tear break-up time tear meniscus height
原文传递
Intra-and interobserver reliability of ocular surface analyzer LacryDiag
4
作者 Eva Kos Valentina Cigić +3 位作者 Mladen Bušić Mirjana Bjeloš Daliborka Miletić Biljana KuzmanovićElabjer 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1418-1422,共5页
AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutiv... AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutive measurements and subsequent analysis of interferometry,TMH,and MBG were recorded by two examiners using the LacryDiag.To assess intra-and interobserver reliability,we used Cohen’s kappa for categorical variables(interferometry),or intraclass correlation coefficient for continuous variables(TMH,MBG).RESULTS:Thirty eyes of 30 examinees were included.For both observers,there was excellent intraobserver reliability for MBG(0.955 and 0.970 for observer 1 and 2,respectively).Intraobserver reliability for observer 1 was substantial for interferometry(0.799),and excellent for TMH(0.863).Reliability for observer 2 was moderate for interferometry(0.535)and fair to good for TMH(0.431).Interobserver reliability was poor for interferometry(0.074)and fair to good for TMH(0.680)and MBG(0.414).CONCLUSION:LacryDiag ocular surface analyzer in our study proves to be a reliable noninvasive tool for the evaluation of TMH and MBG.As for interferometry,poor interobserver reliability,fair to good intraobserver reliability for observer 1,and moderate for observer 2,leave room for improvement. 展开更多
关键词 dry eye ocular surface analyzer INTERFEROMETRY tear meniscus height meibography
原文传递
Comparison of Hasner valvulotomy outcomes in pediatric and adult patients: does age matter? 被引量:2
5
作者 Hua Sun Jing-Wen Ding +1 位作者 Dong-Mei Li Ning-Li Wang 《Chinese Medical Journal》 SCIE CAS CSCD 2020年第20期2422-2428,共7页
Background:Hasner valve incision has been recently introduced as a new treatment for ophthalmic patients with epiphora symptoms. The aim of this study was to examine whether surgical outcomes of Hasner valve incision ... Background:Hasner valve incision has been recently introduced as a new treatment for ophthalmic patients with epiphora symptoms. The aim of this study was to examine whether surgical outcomes of Hasner valve incision for inferior nasolacrimal duct obstruction were different between pediatric and adult patients.Methods:A total of 53 eyes of 52 patients who underwent Hasner valve incision in the Beijing Tongren Hospital from October 2016 to November 2019 were retrospectively observed. Patients were divided into two groups, including pediatric group (23 eyes of 22 patients, <18 years old) and adult group (30 eyes of 30 patients, ≥18 years old). Success rate of surgery was determined by both subjective measure (complete resolution of epiphora) and objective measure (lacrimal passage irrigation and tear meniscus height). Fisher exact test was conducted.Results:By conducting Fisher exact test and comparing complete resolution of epiphora ( P = 0.627), lacrimal passage irrigation ( P = 0.663), measurement of Tear Meniscus Height ( P = 0.561), and appearance of complication ( P = 0.339), there was no statistically significant difference of surgical outcomes between pediatric and adult patients ( P > 0.05). Conclusion:Hasner valve incision was effective for both adult and children with inferior nasolacrimal duct obstruction, with no difference in surgical outcomes between the two groups. 展开更多
关键词 Hasner valve incision Nasolacrimal duct obstruction Lacrimal passage irrigation tear meniscus height
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部