Self-oscillating systems abound in the natural world and offer substantial potential for applications in controllers,micro-motors,medical equipments,and so on.Currently,numerical methods have been widely utilized for ...Self-oscillating systems abound in the natural world and offer substantial potential for applications in controllers,micro-motors,medical equipments,and so on.Currently,numerical methods have been widely utilized for obtaining the characteristics of self-oscillation including amplitude and frequency.However,numerical methods are burdened by intricate computations and limited precision,hindering comprehensive investigations into self-oscillating systems.In this paper,the stability of a liquid crystal elastomer fiber self-oscillating system under a linear temperature field is studied,and analytical solutions for the amplitude and frequency are determined.Initially,we establish the governing equations of self-oscillation,elucidate two motion regimes,and reveal the underlying mechanism.Subsequently,we conduct a stability analysis and employ a multi-scale method to obtain the analytical solutions for the amplitude and frequency.The results show agreement between the multi-scale and numerical methods.This research contributes to the examination of diverse self-oscillating systems and advances the theoretical analysis of self-oscillating systems rooted in active materials.展开更多
Developing efficient energy storage for sodium-ion batteries(SIBs)by creating high-performance heterojunctions and understanding their interfacial interaction at the atomic/molecular level holds promise but is also ch...Developing efficient energy storage for sodium-ion batteries(SIBs)by creating high-performance heterojunctions and understanding their interfacial interaction at the atomic/molecular level holds promise but is also challenging.Besides,sluggish reaction kinetics at low temperatures restrict the operation of SIBs in cold climates.Herein,cross-linking nanoarchitectonics of WS_(2)/Ti_(3)C_(2)T_(x) heterojunction,featuring built-in electric field(BIEF),have been developed,employing as a model to reveal the positive effect of heterojunction design and BIEF for modifying the reaction kinetics and electrochemical activity.Particularly,the theoretical analysis manifests the discrepancy in work functions leads to the electronic flow from the electron-rich Ti_(3)C_(2)T_(x) to layered WS_(2),spontaneously forming the BIEF and“ion reservoir”at the heterogeneous interface.Besides,the generation of cross-linking pathways further promotes the transportation of electrons/ions,which guarantees rapid diffusion kinetics and excellent structure coupling.Consequently,superior sodium storage performance is obtained for the WS_(2)/Ti_(3)C_(2)T_(x) heterojunction,with only 0.2%decay per cycle at 5.0 A g^(-1)(25℃)up to 1000 cycles and a high capacity of 293.5 mA h g^(-1)(0.1A g^(-1)after 100 cycles)even at-20℃.Importantly,the spontaneously formed BIEF,accompanied by“ion reservoir”,in heterojunction provides deep understandings of the correlation between structure fabricated and performance obtained.展开更多
Grinding is a crucial process in machining workpieces because it plays a vital role in achieving the desired precision and surface quality.However,a significant technical challenge in grinding is the potential increas...Grinding is a crucial process in machining workpieces because it plays a vital role in achieving the desired precision and surface quality.However,a significant technical challenge in grinding is the potential increase in temperature due to high specific energy,which can lead to surface thermal damage.Therefore,ensuring control over the surface integrity of workpieces during grinding becomes a critical concern.This necessitates the development of temperature field models that consider various parameters,such as workpiece materials,grinding wheels,grinding parameters,cooling methods,and media,to guide industrial production.This study thoroughly analyzes and summarizes grinding temperature field models.First,the theory of the grinding temperature field is investigated,classifying it into traditional models based on a continuous belt heat source and those based on a discrete heat source,depending on whether the heat source is uniform and continuous.Through this examination,a more accurate grinding temperature model that closely aligns with practical grinding conditions is derived.Subsequently,various grinding thermal models are summarized,including models for the heat source distribution,energy distribution proportional coefficient,and convective heat transfer coefficient.Through comprehensive research,the most widely recognized,utilized,and accurate model for each category is identified.The application of these grinding thermal models is reviewed,shedding light on the governing laws that dictate the influence of the heat source distribution,heat distribution,and convective heat transfer in the grinding arc zone on the grinding temperature field.Finally,considering the current issues in the field of grinding temperature,potential future research directions are proposed.The aim of this study is to provide theoretical guidance and technical support for predicting workpiece temperature and improving surface integrity.展开更多
The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analy...The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analyzed.On this basis,a physical laser line scanning model is proposed.Afterwards,based on Fourier transform(FT)and segregation variablemethod(SVM),the heat conduction differential equation in laser line scanning thermography is derived in detail.The temperature field of the composite-based coatings model with defects is simulated numerically.The results show that the laser line scanning thermography can effectively detect the defects in the model.The correctness of the analytical calculation is verified by comparing the surface temperature distribution obtained by analytical calculation and numerical simulation.Additionally,an experiment is carried out and the changeable surface temperature obtained by analytical calculation is compared with the experimental results.It shows that the error of maximum temperature obtained by analytical calculation and by experiment is 8%with high accuracy,which proves the correctness of analytical calculation and enriches the theoretical foundation of laser line scanning thermography.展开更多
A two-layer implicit difference scheme is employed in the present study to determine the temperature distribution in an asphalt pavement.The calculation of each layer only needs four iterations to achieve convergence....A two-layer implicit difference scheme is employed in the present study to determine the temperature distribution in an asphalt pavement.The calculation of each layer only needs four iterations to achieve convergence.Furthermore,in order to improve the calculation accuracy a swarm intelligence optimization algorithm is also exploited to inversely analyze the laws by which the thermal physical parameters of the asphalt pavement materials change with temperature.Using the basic cuckoo and the gray wolf algorithms,an adaptive hybrid optimization algorithm is obtained and used to determine the relationship between the thermal diffusivity of two types of asphalt pavement materials and the temperature.As shown by the results,the prediction accuracy achievable with this approach is higher than that of the linear model.展开更多
Purpose-It is of great significance to study the influence of subgrade filling on permafrost temperature field in permafrost area for the smooth construction and safe operation of railway.Design/methodology/approach-T...Purpose-It is of great significance to study the influence of subgrade filling on permafrost temperature field in permafrost area for the smooth construction and safe operation of railway.Design/methodology/approach-The paper builds up the model for the hydrothermal coupling calculation of permafrost using finite element software COMSOL to study how permafrost temperature field changes in the short term after subgrade filling,on which basis it proposes the method of calculation for the concave distortion of freezing front in the subgrade-covered area.Findings-The results show that the freezing front below the subgrade center sinks due to the thermal effect of subgrade filling,which will trigger hydrothermal erosion in case of sufficient moisture inflows,leading to the thawing settlement or the cracking of the subgrade,etc.The heat output of soil will be hindered the most in case of July filling,in which case the sinking and the distortion of the freezing front is found to be the most severe,which the recovery of the permafrost temperature field,the slowest,constituting the most unfavorable working condition.The concave distortion of the freezing front in the subgrade area increases with the increase in temperature difference between the filler and ground surface,the subgrade height,the subgrade width and the volumetric thermal capacity of filler,while decreases with the increase of the thermal conductivity of filler.Therefore,the filler chose for engineering project shall be of small volumetric thermal capacity,low initial temperature and high thermal conductivity whenever possible.Originality/value-The concave distortion of the freezing front under different working conditions at different times after filling can be calculated using the method proposed.展开更多
The photovoltaic (PV) cell performances are connected to the base photogenerated carriers charge. Some studies showed that the quantity of the photogenerated carriers charge increases with the increase of the solar il...The photovoltaic (PV) cell performances are connected to the base photogenerated carriers charge. Some studies showed that the quantity of the photogenerated carriers charge increases with the increase of the solar illumination. This situation explains the choice of concentration PV cell (C = 50 suns) in this study. However, the strong photogeneration of the carriers charge causes a high heat production by thermalization, collision and carriers charge braking due to the electric field induced by concentration gradient. This heat brings the heating of the PV cell base. That imposes the taking into account of the temperature influence in the concentrator PV cell operation. Moreover, with the proliferation of the magnetic field sources in the life space, it is important to consider its effect on the PV cell performances. Thus, when magnetic field and base temperature increase simultaneously, we observe a deterioration of the photovoltage, the electric power, the space charge region capacity, the fill factor and the conversion efficiency. However the photocurrent increases when the base temperature increases and the magnetic field strength decreases. It appears an inversion phenomenon in the evolution of the electrical parameters as a function of magnetic field for the values of magnetic field B> 4×10<sup>-4 </sup>T.展开更多
Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and d...Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and divertor plasma transport in magnetically confined fusion research.On the J-TEXT tokamak,a multi-channel retarding field analyzer(RFA) probe has been developed to study average plasma parameters in the edge region under various poloidal divertor and island divertor configurations.The edge radial profile of the ion-to-electron temperature ratio,τ_(i/e),has been determined,which gradually decreases as the SOL ion self-collisionality,v_(SOL)*,increases.This is broadly consistent with what has been observed previously from various tokamak experiments.However,the comparison of experimental results under different configurations shows that in the poloidal divertor configuration,even under the same v_(SOL)*,τ_(i/e) in the SOL region becomes smaller as the distance from the X-point to the target plate increases.In the island divertor configuration,τ_(i/e) near the O-point is higher than that near the X-point at the same v_(SOL)*,and both are higher than those in the limiter configuration.These results suggest that the magnetic configuration plays a critical role in the energy distributions between electrons and ions at the plasma boundary.展开更多
Building energy consumption and building carbon emissions both account for more than 20%of their total national values in China.Building employing phase change material(PCM)for passive temperature control shows a prom...Building energy consumption and building carbon emissions both account for more than 20%of their total national values in China.Building employing phase change material(PCM)for passive temperature control shows a promising prospect in meeting the comfort demand and reducing energy consumption simultaneously.However,there is a lack of more detailed research on the interaction between the location and thickness of PCM and indoor natural convection,as well as indoor temperature distribution.In this study,the numerical model of a passive temperature-controlled building integrating the developed PCM module is established with the help of ANSYS.In which,the actual weather condition of Beijing city is set as the boundary conditions and the indoor natural convection is simulated with the consideration of radiation model.The effects of PCM’s thickness and location on the internal temperature field are analyzed and discussed.The results show that the room could maintain within the human comfort temperature range with the longest ratio of 94.10%and the shortest ratio of 51.04%as integrating PCM.In comparison,the value is only 26.70%without PCM.The room’s maximum temperature fluctuation can also be improved;it could be lowered by 64.4%compared to the normal condition.When the quantity of PCM is sufficient,further increasing the PCM amount results in a temperature fluctuation reduction of less than 0.1°C and does not increase the comfort time.Placing PCM on the wall induces an apparent variation in indoor temperature along the vertical direction.Conversely,placing PCM on the roof can lead to a heat transfer rate difference of up to seven times.The optimal placement of PCM depends on the difference between the environmental and phase change temperatures.If the difference is positive,placing PCM on the roof is more effective;conversely,the opposite holds.According to the results over the entire cycle,PCM application on vertical walls yields better performance.The significant difference in natural convection caused by the same thickness of PCM but different application positions,coupled with the influence of air movement on the melting and solidification of PCM,further impacts indoor temperature fluctuations and comfort.This study can provide guidance for the application location and thickness of PCM,especially for scenarios where temperature regulation is required at a specific time.展开更多
Complicated changns occur inside the steel parts during quenching process. The abruptly changed boundary conditions make the temperature field,micro - structure and stress field change dramatically in very short time,...Complicated changns occur inside the steel parts during quenching process. The abruptly changed boundary conditions make the temperature field,micro - structure and stress field change dramatically in very short time, and these variables take a contact interactions in the whole process. In this paper, a three dimensional non - linear mathematical model for queeching process has been founded and the numerical simulation on temperature field,microstructre and stress field has been realized.In the FEM analysis, the incremental iteration method is used to deal with such complicated nonlinear as boundary nonlinear, physical property nonlinear,transformation nonlinear etc.The effect of stress on transformation kinetics has been considered in the calculation of microstructure. In the stress field anal- ysis,a thermo- elasto - plastic model has been founded, which considers such factors as transforma- tion strain,transformation plastic strain, themal strain and the effect of temperature and transforma- tion on mechanical propertier etc. The transient temperature field, microstructure distribution and stress field of the roller on any time can be displayed vividly,and the cooling curve and the changes of stress on any position can also be given.展开更多
To improve the mechanical properties of the parts fabricated by Laser Direct Metal Shaping(LDMS),it is of great significance to understand the distribution regularities of transient temperature field during LDMS proce...To improve the mechanical properties of the parts fabricated by Laser Direct Metal Shaping(LDMS),it is of great significance to understand the distribution regularities of transient temperature field during LDMS process.Based on the“el- ement birth and death”technique of finite element method,a three-dimensional multi-track and multi-layer model for the transient temperature field analysis of LDMS is developed by ANSYS Parametric Design Language(APDL)for the first time.In the fab- ricated modal,X-direction parallel reciprocating scanning paths is introduced.Using the same process parameters,the simulation results show good agreement with the microstructure features of samples which fabricated by LDMS.展开更多
This paper has analyzed the influences of the heat input of welding arc, the latent heat of solidifica- tion,fluid flow of liquid metal on the heat conductivity pertaining to welding solidification crack of stainless ...This paper has analyzed the influences of the heat input of welding arc, the latent heat of solidifica- tion,fluid flow of liquid metal on the heat conductivity pertaining to welding solidification crack of stainless steels. As a result,two - dimensional heat conduction models with prescribed heat flux mov- ing along the the have been developed that can simulate welding arc, convection and radiation heat loss from top and bottom surfaces of the workpiece. Finally, the finite element model was used to ana- lyze and calculate the temperature field.展开更多
To study the distribution characteristics and variation regularity of the temperature field during the process of seepage freezing,a simulated-freezing test with seepage of Xuzhou sand was completed by using a model t...To study the distribution characteristics and variation regularity of the temperature field during the process of seepage freezing,a simulated-freezing test with seepage of Xuzhou sand was completed by using a model test developed in-house equipment.By means of three group freezing tests with different seepage velocities,we discovered the phenomenon of the asymmetry of the temperature field under the influence of seepage.The temperature upstream was obviously higher than that downstream.The temperature gradient upstream was also steeper than that downstream.With a higher seepage velocity,the asymmetry of the temperature field is more pronounced.The asymmetry for the interface temperature profile is more strongly manifest than for the main surface temperature profile.The cryogenic barrier section is somewhat"heartshaped".With the increasing velocity of the seepage flow,the cooling rate of the soil decreases.It takes much time to reach the equilibrium state of the soil mass.In our study,seepage flow velocities of 0 m/d,7.5 m/d,and 15 m/d showed the soilcooling rate of 4.35°C/h,4.96°C/h,and 1.72°C/h,respectively.展开更多
A three-dimensional transient heat transfer model for laser transformation hardening process has been developed in this paper. The finite size of the laser treated sample, the surface heat loss of the sample, the late...A three-dimensional transient heat transfer model for laser transformation hardening process has been developed in this paper. The finite size of the laser treated sample, the surface heat loss of the sample, the latent heat of phase transformation and the temperature dependence of thermal properties of materials were considered. The heat source was considered as a moving Gaussian heat flux with a constant velocity. Three-dimension unequally spatial grid explicit finite difference equations, alternating direction implicit finite difference equations and implicit finite difference equations were deduced respectively. Three programs to calculate the temperature field were developed using Fortran language. The transient temperature fields of C22, 42CrMo, C60 steel samples during laser transformation hardening process were calculated using these programs, and the widths and depths of laser transformation hardening zones were also predicted. C22, 42CrMo, C60 steel samples were treated by CO2 laser,the widths and depths of laser transformation hardening zones of these samples were also measured experimentally. The calculated widths and depths of laser transformation hardening zones are in good agreement with the experimental results.展开更多
It is essential to investigate the light field camera parameters for the accurate flame temperature measurement because the sampling characteristics of the flame radiation can be varied with them. In this study, novel...It is essential to investigate the light field camera parameters for the accurate flame temperature measurement because the sampling characteristics of the flame radiation can be varied with them. In this study, novel indices of the light field camera were proposed to investigate the directional and spatial sampling characteristics of the flame radiation. Effects of light field camera parameters such as focal length and magnification of the main lens, focal length and magnification of the microlens were investigated. It was observed that the sampling characteristics of the flame are varied with the different parameters of the light field camera. The optimized parameters of the light field camera were then proposed for the flame radiation sampling. The larger sampling angle(23 times larger) is achieved by the optimized parameters compared to the commercial light field camera parameters. A non-negative least square(NNLS) algorithm was used to reconstruct the flame temperature. The reconstruction accuracy was also evaluated by the optimized parameters. The results suggested that the optimized parameters can provide higher reconstruction accuracy for axisymmetric and non-symmetric flame conditions in comparison to the commercial light field camera.展开更多
The model established in this paper for calculating the unsteady temperature field, in which physical parameters varies with temperatures, is simplified as compared with the classical one by defining the heat conducti...The model established in this paper for calculating the unsteady temperature field, in which physical parameters varies with temperatures, is simplified as compared with the classical one by defining the heat conductivity as function of temperature and dealing with the latent heat of phase transformation and boundary conditions. The results show that the probability of absolute error less 2℃ between the calculated and measured values in temperature field calculation reaches above 80%.展开更多
This work presented the development and validation of an analytical method to predict the transient temperature field in the asphalt pavement.The governing equation for heat transfer was based on heat conduction radia...This work presented the development and validation of an analytical method to predict the transient temperature field in the asphalt pavement.The governing equation for heat transfer was based on heat conduction radiation and convection.An innovative time-dependent function was proposed to predict the pavement surface temperature with solar radiation and air temperature using dimensional analysis in order to simplify the complex heat exchange on the pavement surface.The parameters for the time-dependent pavement surface temperature function were obtained through the regression analysis of field measurement data.Assuming that the initial pavement temperature distribution was linear and the influence of the base course materials on the temperature of the upper asphalt layers was negligible,a close-form analytical solution of the temperature in asphalt layers was derived using Green's function.Finally,two numerical examples were presented to validate the model solutions with field temperature measurements.Analysis results show that the solution accuracy is in agreement with field data and the relative errors at a shallower depth are greater than those at a deeper one.Although the model is not sensitive to dramatic changes in climatic factors near the pavement surface,it is applicable for predicting pavement temperature field in cloudless days.展开更多
A Two-dimensional transient heat transfer model for laser transformation hardening process of cylindrical bodies has been developed. The surface heat loss of the sample, the latent heat of phase transformation, and th...A Two-dimensional transient heat transfer model for laser transformation hardening process of cylindrical bodies has been developed. The surface heat loss of the sample, the latent heat of phase transformation, and the temperature dependence of thermal properties of material were considered. The laser heat source was considered as a moving Gaussian heat flux with a constant velocity. Finite element method was used to calculate the transient temperature field. A program to calculate the temperature field was developed using FORTRAN language. The transient temperature field, the width and depth of laser transformation hardening zone of 42CrMo steel sample during laser transformation hardening process was calculated. The widths and depths of laser transformation hardening zones of 42CrMo steel samples were also measured experimentally. The calculated widths and depths of laser transformation hardening zones are in good agreement with the experimental results.展开更多
The PPG PITT-CHAR XP flame retardant system has been used by COOEC to preventing the thermal softening of steel in the high temperature,whose degradation temperature is 80 ℃.To prevent damage to PPG PITT-CHAR XP fire...The PPG PITT-CHAR XP flame retardant system has been used by COOEC to preventing the thermal softening of steel in the high temperature,whose degradation temperature is 80 ℃.To prevent damage to PPG PITT-CHAR XP fire retardant paint from excessive heat during welding,it is necessary to get accurately reserved area near the welding joints prior to welding. For the foregoing reasons,the 80 ℃ temperature field distribution of thick plate multi-pass welding was analyzed with SYSWELD.The influence of welding groove form and time interval on welding temperature field was also analyzed. Results showed that the range of 80 ℃ welding temperature field increased with the increasing of weld layers at first and then it inclined to stable value. Interpass time setting was crucial to control the range of 80 ℃ welding temperature field. It was also found that double V groove had better thermal diffusivity than double-bevel groove.And double-bevel groove was better than single V groove.展开更多
基金Project supported by the National Natural Science Foundation of China (No.12172001)the Anhui Provincial Natural Science Foundation of China (No.2208085Y01)+1 种基金the University Natural Science Research Project of Anhui Province of China (No.2022AH020029)the Housing and Urban-Rural Development Science and Technology Project of Anhui Province of China (No.2023-YF129)。
文摘Self-oscillating systems abound in the natural world and offer substantial potential for applications in controllers,micro-motors,medical equipments,and so on.Currently,numerical methods have been widely utilized for obtaining the characteristics of self-oscillation including amplitude and frequency.However,numerical methods are burdened by intricate computations and limited precision,hindering comprehensive investigations into self-oscillating systems.In this paper,the stability of a liquid crystal elastomer fiber self-oscillating system under a linear temperature field is studied,and analytical solutions for the amplitude and frequency are determined.Initially,we establish the governing equations of self-oscillation,elucidate two motion regimes,and reveal the underlying mechanism.Subsequently,we conduct a stability analysis and employ a multi-scale method to obtain the analytical solutions for the amplitude and frequency.The results show agreement between the multi-scale and numerical methods.This research contributes to the examination of diverse self-oscillating systems and advances the theoretical analysis of self-oscillating systems rooted in active materials.
基金supported by the faculty startup funds from the Yangzhou Universitythe Natural Science Foundation of Jiangsu Province(BK20210821)+1 种基金the National Natural Science Foundation of China(22102141)the Lvyangjinfeng Talent Program of Yangzhou。
文摘Developing efficient energy storage for sodium-ion batteries(SIBs)by creating high-performance heterojunctions and understanding their interfacial interaction at the atomic/molecular level holds promise but is also challenging.Besides,sluggish reaction kinetics at low temperatures restrict the operation of SIBs in cold climates.Herein,cross-linking nanoarchitectonics of WS_(2)/Ti_(3)C_(2)T_(x) heterojunction,featuring built-in electric field(BIEF),have been developed,employing as a model to reveal the positive effect of heterojunction design and BIEF for modifying the reaction kinetics and electrochemical activity.Particularly,the theoretical analysis manifests the discrepancy in work functions leads to the electronic flow from the electron-rich Ti_(3)C_(2)T_(x) to layered WS_(2),spontaneously forming the BIEF and“ion reservoir”at the heterogeneous interface.Besides,the generation of cross-linking pathways further promotes the transportation of electrons/ions,which guarantees rapid diffusion kinetics and excellent structure coupling.Consequently,superior sodium storage performance is obtained for the WS_(2)/Ti_(3)C_(2)T_(x) heterojunction,with only 0.2%decay per cycle at 5.0 A g^(-1)(25℃)up to 1000 cycles and a high capacity of 293.5 mA h g^(-1)(0.1A g^(-1)after 100 cycles)even at-20℃.Importantly,the spontaneously formed BIEF,accompanied by“ion reservoir”,in heterojunction provides deep understandings of the correlation between structure fabricated and performance obtained.
基金financially supported by the National Natural Science Foundation of China(Grant Nos.52205481,51975305 and 52105457)Shandong Natural Science Foundation(Grant Nos.ZR2020ME158,ZR2023QE057,ZR2022QE028,ZR2021QE116,ZR2020KE027,and ZR2022QE159)+1 种基金Qingdao Science and Technology Planning Park Cultivation Plan(23-1-5-yqpy-17-qy)China Postdoctral Science Foundation(2021M701810).
文摘Grinding is a crucial process in machining workpieces because it plays a vital role in achieving the desired precision and surface quality.However,a significant technical challenge in grinding is the potential increase in temperature due to high specific energy,which can lead to surface thermal damage.Therefore,ensuring control over the surface integrity of workpieces during grinding becomes a critical concern.This necessitates the development of temperature field models that consider various parameters,such as workpiece materials,grinding wheels,grinding parameters,cooling methods,and media,to guide industrial production.This study thoroughly analyzes and summarizes grinding temperature field models.First,the theory of the grinding temperature field is investigated,classifying it into traditional models based on a continuous belt heat source and those based on a discrete heat source,depending on whether the heat source is uniform and continuous.Through this examination,a more accurate grinding temperature model that closely aligns with practical grinding conditions is derived.Subsequently,various grinding thermal models are summarized,including models for the heat source distribution,energy distribution proportional coefficient,and convective heat transfer coefficient.Through comprehensive research,the most widely recognized,utilized,and accurate model for each category is identified.The application of these grinding thermal models is reviewed,shedding light on the governing laws that dictate the influence of the heat source distribution,heat distribution,and convective heat transfer in the grinding arc zone on the grinding temperature field.Finally,considering the current issues in the field of grinding temperature,potential future research directions are proposed.The aim of this study is to provide theoretical guidance and technical support for predicting workpiece temperature and improving surface integrity.
基金supported by the National Natural Science Foundation of China(Grant No.52005495).
文摘The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analyzed.On this basis,a physical laser line scanning model is proposed.Afterwards,based on Fourier transform(FT)and segregation variablemethod(SVM),the heat conduction differential equation in laser line scanning thermography is derived in detail.The temperature field of the composite-based coatings model with defects is simulated numerically.The results show that the laser line scanning thermography can effectively detect the defects in the model.The correctness of the analytical calculation is verified by comparing the surface temperature distribution obtained by analytical calculation and numerical simulation.Additionally,an experiment is carried out and the changeable surface temperature obtained by analytical calculation is compared with the experimental results.It shows that the error of maximum temperature obtained by analytical calculation and by experiment is 8%with high accuracy,which proves the correctness of analytical calculation and enriches the theoretical foundation of laser line scanning thermography.
文摘A two-layer implicit difference scheme is employed in the present study to determine the temperature distribution in an asphalt pavement.The calculation of each layer only needs four iterations to achieve convergence.Furthermore,in order to improve the calculation accuracy a swarm intelligence optimization algorithm is also exploited to inversely analyze the laws by which the thermal physical parameters of the asphalt pavement materials change with temperature.Using the basic cuckoo and the gray wolf algorithms,an adaptive hybrid optimization algorithm is obtained and used to determine the relationship between the thermal diffusivity of two types of asphalt pavement materials and the temperature.As shown by the results,the prediction accuracy achievable with this approach is higher than that of the linear model.
基金supported by the Fund of China Academy of Railway Sciences Corporation Limited (2019YJ041).
文摘Purpose-It is of great significance to study the influence of subgrade filling on permafrost temperature field in permafrost area for the smooth construction and safe operation of railway.Design/methodology/approach-The paper builds up the model for the hydrothermal coupling calculation of permafrost using finite element software COMSOL to study how permafrost temperature field changes in the short term after subgrade filling,on which basis it proposes the method of calculation for the concave distortion of freezing front in the subgrade-covered area.Findings-The results show that the freezing front below the subgrade center sinks due to the thermal effect of subgrade filling,which will trigger hydrothermal erosion in case of sufficient moisture inflows,leading to the thawing settlement or the cracking of the subgrade,etc.The heat output of soil will be hindered the most in case of July filling,in which case the sinking and the distortion of the freezing front is found to be the most severe,which the recovery of the permafrost temperature field,the slowest,constituting the most unfavorable working condition.The concave distortion of the freezing front in the subgrade area increases with the increase in temperature difference between the filler and ground surface,the subgrade height,the subgrade width and the volumetric thermal capacity of filler,while decreases with the increase of the thermal conductivity of filler.Therefore,the filler chose for engineering project shall be of small volumetric thermal capacity,low initial temperature and high thermal conductivity whenever possible.Originality/value-The concave distortion of the freezing front under different working conditions at different times after filling can be calculated using the method proposed.
文摘The photovoltaic (PV) cell performances are connected to the base photogenerated carriers charge. Some studies showed that the quantity of the photogenerated carriers charge increases with the increase of the solar illumination. This situation explains the choice of concentration PV cell (C = 50 suns) in this study. However, the strong photogeneration of the carriers charge causes a high heat production by thermalization, collision and carriers charge braking due to the electric field induced by concentration gradient. This heat brings the heating of the PV cell base. That imposes the taking into account of the temperature influence in the concentrator PV cell operation. Moreover, with the proliferation of the magnetic field sources in the life space, it is important to consider its effect on the PV cell performances. Thus, when magnetic field and base temperature increase simultaneously, we observe a deterioration of the photovoltage, the electric power, the space charge region capacity, the fill factor and the conversion efficiency. However the photocurrent increases when the base temperature increases and the magnetic field strength decreases. It appears an inversion phenomenon in the evolution of the electrical parameters as a function of magnetic field for the values of magnetic field B> 4×10<sup>-4 </sup>T.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China (No.2018YFE0309100)National Natural Science Foundation of China (No.51821005)。
文摘Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and divertor plasma transport in magnetically confined fusion research.On the J-TEXT tokamak,a multi-channel retarding field analyzer(RFA) probe has been developed to study average plasma parameters in the edge region under various poloidal divertor and island divertor configurations.The edge radial profile of the ion-to-electron temperature ratio,τ_(i/e),has been determined,which gradually decreases as the SOL ion self-collisionality,v_(SOL)*,increases.This is broadly consistent with what has been observed previously from various tokamak experiments.However,the comparison of experimental results under different configurations shows that in the poloidal divertor configuration,even under the same v_(SOL)*,τ_(i/e) in the SOL region becomes smaller as the distance from the X-point to the target plate increases.In the island divertor configuration,τ_(i/e) near the O-point is higher than that near the X-point at the same v_(SOL)*,and both are higher than those in the limiter configuration.These results suggest that the magnetic configuration plays a critical role in the energy distributions between electrons and ions at the plasma boundary.
基金supported by National Innovation Talent Promotion Program(G2022013028L).
文摘Building energy consumption and building carbon emissions both account for more than 20%of their total national values in China.Building employing phase change material(PCM)for passive temperature control shows a promising prospect in meeting the comfort demand and reducing energy consumption simultaneously.However,there is a lack of more detailed research on the interaction between the location and thickness of PCM and indoor natural convection,as well as indoor temperature distribution.In this study,the numerical model of a passive temperature-controlled building integrating the developed PCM module is established with the help of ANSYS.In which,the actual weather condition of Beijing city is set as the boundary conditions and the indoor natural convection is simulated with the consideration of radiation model.The effects of PCM’s thickness and location on the internal temperature field are analyzed and discussed.The results show that the room could maintain within the human comfort temperature range with the longest ratio of 94.10%and the shortest ratio of 51.04%as integrating PCM.In comparison,the value is only 26.70%without PCM.The room’s maximum temperature fluctuation can also be improved;it could be lowered by 64.4%compared to the normal condition.When the quantity of PCM is sufficient,further increasing the PCM amount results in a temperature fluctuation reduction of less than 0.1°C and does not increase the comfort time.Placing PCM on the wall induces an apparent variation in indoor temperature along the vertical direction.Conversely,placing PCM on the roof can lead to a heat transfer rate difference of up to seven times.The optimal placement of PCM depends on the difference between the environmental and phase change temperatures.If the difference is positive,placing PCM on the roof is more effective;conversely,the opposite holds.According to the results over the entire cycle,PCM application on vertical walls yields better performance.The significant difference in natural convection caused by the same thickness of PCM but different application positions,coupled with the influence of air movement on the melting and solidification of PCM,further impacts indoor temperature fluctuations and comfort.This study can provide guidance for the application location and thickness of PCM,especially for scenarios where temperature regulation is required at a specific time.
文摘Complicated changns occur inside the steel parts during quenching process. The abruptly changed boundary conditions make the temperature field,micro - structure and stress field change dramatically in very short time, and these variables take a contact interactions in the whole process. In this paper, a three dimensional non - linear mathematical model for queeching process has been founded and the numerical simulation on temperature field,microstructre and stress field has been realized.In the FEM analysis, the incremental iteration method is used to deal with such complicated nonlinear as boundary nonlinear, physical property nonlinear,transformation nonlinear etc.The effect of stress on transformation kinetics has been considered in the calculation of microstructure. In the stress field anal- ysis,a thermo- elasto - plastic model has been founded, which considers such factors as transforma- tion strain,transformation plastic strain, themal strain and the effect of temperature and transforma- tion on mechanical propertier etc. The transient temperature field, microstructure distribution and stress field of the roller on any time can be displayed vividly,and the cooling curve and the changes of stress on any position can also be given.
文摘To improve the mechanical properties of the parts fabricated by Laser Direct Metal Shaping(LDMS),it is of great significance to understand the distribution regularities of transient temperature field during LDMS process.Based on the“el- ement birth and death”technique of finite element method,a three-dimensional multi-track and multi-layer model for the transient temperature field analysis of LDMS is developed by ANSYS Parametric Design Language(APDL)for the first time.In the fab- ricated modal,X-direction parallel reciprocating scanning paths is introduced.Using the same process parameters,the simulation results show good agreement with the microstructure features of samples which fabricated by LDMS.
文摘This paper has analyzed the influences of the heat input of welding arc, the latent heat of solidifica- tion,fluid flow of liquid metal on the heat conductivity pertaining to welding solidification crack of stainless steels. As a result,two - dimensional heat conduction models with prescribed heat flux mov- ing along the the have been developed that can simulate welding arc, convection and radiation heat loss from top and bottom surfaces of the workpiece. Finally, the finite element model was used to ana- lyze and calculate the temperature field.
基金financially supported by the National Natural Science Foundation of China (No. 41201070)Project of Education Department of Jiangxi Province (GJJ14494)+1 种基金Development Fund Project of State Key Laboratory of Frozen Soil Engineering (SKLFSE 201508)Development Fund Project of State Key Laboratory for Geomechanics & Deep Underground Engineering (SKLGDUEK1505)
文摘To study the distribution characteristics and variation regularity of the temperature field during the process of seepage freezing,a simulated-freezing test with seepage of Xuzhou sand was completed by using a model test developed in-house equipment.By means of three group freezing tests with different seepage velocities,we discovered the phenomenon of the asymmetry of the temperature field under the influence of seepage.The temperature upstream was obviously higher than that downstream.The temperature gradient upstream was also steeper than that downstream.With a higher seepage velocity,the asymmetry of the temperature field is more pronounced.The asymmetry for the interface temperature profile is more strongly manifest than for the main surface temperature profile.The cryogenic barrier section is somewhat"heartshaped".With the increasing velocity of the seepage flow,the cooling rate of the soil decreases.It takes much time to reach the equilibrium state of the soil mass.In our study,seepage flow velocities of 0 m/d,7.5 m/d,and 15 m/d showed the soilcooling rate of 4.35°C/h,4.96°C/h,and 1.72°C/h,respectively.
文摘A three-dimensional transient heat transfer model for laser transformation hardening process has been developed in this paper. The finite size of the laser treated sample, the surface heat loss of the sample, the latent heat of phase transformation and the temperature dependence of thermal properties of materials were considered. The heat source was considered as a moving Gaussian heat flux with a constant velocity. Three-dimension unequally spatial grid explicit finite difference equations, alternating direction implicit finite difference equations and implicit finite difference equations were deduced respectively. Three programs to calculate the temperature field were developed using Fortran language. The transient temperature fields of C22, 42CrMo, C60 steel samples during laser transformation hardening process were calculated using these programs, and the widths and depths of laser transformation hardening zones were also predicted. C22, 42CrMo, C60 steel samples were treated by CO2 laser,the widths and depths of laser transformation hardening zones of these samples were also measured experimentally. The calculated widths and depths of laser transformation hardening zones are in good agreement with the experimental results.
基金supported by the National Natural Science Foundation of China(Grant Nos.51676044 and 51327803)the Social Development Project of Jiangsu Province,China(Grant No.BE20187053)+1 种基金the Postgraduate Research and Practice Innovation Program of Jiangsu Province,China(Grant No.KYCX170081)China Scholarship Council
文摘It is essential to investigate the light field camera parameters for the accurate flame temperature measurement because the sampling characteristics of the flame radiation can be varied with them. In this study, novel indices of the light field camera were proposed to investigate the directional and spatial sampling characteristics of the flame radiation. Effects of light field camera parameters such as focal length and magnification of the main lens, focal length and magnification of the microlens were investigated. It was observed that the sampling characteristics of the flame are varied with the different parameters of the light field camera. The optimized parameters of the light field camera were then proposed for the flame radiation sampling. The larger sampling angle(23 times larger) is achieved by the optimized parameters compared to the commercial light field camera parameters. A non-negative least square(NNLS) algorithm was used to reconstruct the flame temperature. The reconstruction accuracy was also evaluated by the optimized parameters. The results suggested that the optimized parameters can provide higher reconstruction accuracy for axisymmetric and non-symmetric flame conditions in comparison to the commercial light field camera.
文摘The model established in this paper for calculating the unsteady temperature field, in which physical parameters varies with temperatures, is simplified as compared with the classical one by defining the heat conductivity as function of temperature and dealing with the latent heat of phase transformation and boundary conditions. The results show that the probability of absolute error less 2℃ between the calculated and measured values in temperature field calculation reaches above 80%.
基金Project(2012zzts019)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(201306370121)supported by State Scholarship Fund of ChinaProject(51248006)supported by the National Natural Science Foundation,China
文摘This work presented the development and validation of an analytical method to predict the transient temperature field in the asphalt pavement.The governing equation for heat transfer was based on heat conduction radiation and convection.An innovative time-dependent function was proposed to predict the pavement surface temperature with solar radiation and air temperature using dimensional analysis in order to simplify the complex heat exchange on the pavement surface.The parameters for the time-dependent pavement surface temperature function were obtained through the regression analysis of field measurement data.Assuming that the initial pavement temperature distribution was linear and the influence of the base course materials on the temperature of the upper asphalt layers was negligible,a close-form analytical solution of the temperature in asphalt layers was derived using Green's function.Finally,two numerical examples were presented to validate the model solutions with field temperature measurements.Analysis results show that the solution accuracy is in agreement with field data and the relative errors at a shallower depth are greater than those at a deeper one.Although the model is not sensitive to dramatic changes in climatic factors near the pavement surface,it is applicable for predicting pavement temperature field in cloudless days.
文摘A Two-dimensional transient heat transfer model for laser transformation hardening process of cylindrical bodies has been developed. The surface heat loss of the sample, the latent heat of phase transformation, and the temperature dependence of thermal properties of material were considered. The laser heat source was considered as a moving Gaussian heat flux with a constant velocity. Finite element method was used to calculate the transient temperature field. A program to calculate the temperature field was developed using FORTRAN language. The transient temperature field, the width and depth of laser transformation hardening zone of 42CrMo steel sample during laser transformation hardening process was calculated. The widths and depths of laser transformation hardening zones of 42CrMo steel samples were also measured experimentally. The calculated widths and depths of laser transformation hardening zones are in good agreement with the experimental results.
基金Project(No.2016ZDJS05B03)supported by Shandong Key ResearchDevelopment Plan,Project(No.17CX06005&No.18CX06054A)supported by Department of Science&Technology of Shandong Province the Fundamental Research Funds for the Central Universities
文摘The PPG PITT-CHAR XP flame retardant system has been used by COOEC to preventing the thermal softening of steel in the high temperature,whose degradation temperature is 80 ℃.To prevent damage to PPG PITT-CHAR XP fire retardant paint from excessive heat during welding,it is necessary to get accurately reserved area near the welding joints prior to welding. For the foregoing reasons,the 80 ℃ temperature field distribution of thick plate multi-pass welding was analyzed with SYSWELD.The influence of welding groove form and time interval on welding temperature field was also analyzed. Results showed that the range of 80 ℃ welding temperature field increased with the increasing of weld layers at first and then it inclined to stable value. Interpass time setting was crucial to control the range of 80 ℃ welding temperature field. It was also found that double V groove had better thermal diffusivity than double-bevel groove.And double-bevel groove was better than single V groove.