[Objective]The paper was to establish a fluorescence quantitative RT-PCR method for detection of equine arteritis virus(EAV).[Method]Primers and probes were developed for the EAV ORF7 gene sequence,and the reaction sy...[Objective]The paper was to establish a fluorescence quantitative RT-PCR method for detection of equine arteritis virus(EAV).[Method]Primers and probes were developed for the EAV ORF7 gene sequence,and the reaction system was optimized.Standard curves were established,leading to the initial development of the EAV fluorescence quantitative RT-PCR assay.The accuracy,specificity,and sensitivity of this method were subsequently evaluated.[Result]The EAV fluorescence quantitative RT-PCR assay demonstrated optimal performance at an annealing temperature of 61 C,with a final concentration of primer and probe set at 0.6μmol/L.The plasmid standard demonstrated a strong linear correlation with Ct values within the range of 1.6×10^(7)-1.6×10^(2)copies/μL.The equation of the standard curve was determined to be y=-2.68x+32.88,with an R^(2) value of 0.9927.Consequently,the EAV fluorescence quantitative RT-PCR assay was successfully established.The methodology employed was effective in detecting EAV,Theileria equi,equine herpesvirus-1(EHV-1),equine herpesvirus-4(EHV-4),and equine influenza virus(EIV).The findings indicated that the method was specifically capable of detecting EAV,while the other pathogens tested yielded negative results.The method demonstrated a high degree of specificity.It was employed to detect the standard plasmid cRNA synthesized through in vitro transcription following a 10-fold dilution.The results indicated that the minimum detection limit of the method was 1.6×10^(2) copies/μL,and it exhibited high sensitivity.The coefficient of variation,both within and between groups,was maintained at 1.8%,indicating good reproducibility.In this study,the fluorescence quantitative RT-PCR assay developed was utilized alongside the EAV fluorescence quantitative RT-PCR assay established by previous researchers to analyze a total of 234 clinical samples.Both methods yielded a positive detection rate of 14.1%,and the coincidence rate between the two techniques was found to be 100%.[Conclusion]The fluorescence quantitative RT-PCR assay developed in this study offers a novel approach and concept for the prevention and control of equine viral arteritis(EVA).展开更多
BACKGROUND Quantitative fluorescent polymerase chain reaction(QF-PCR)is a rapid prenatal diagnostic method for abnormalities on chromosomes 21,18,and 13 and sex chromosomal aneuploidy.However,the value of QF-PCR in di...BACKGROUND Quantitative fluorescent polymerase chain reaction(QF-PCR)is a rapid prenatal diagnostic method for abnormalities on chromosomes 21,18,and 13 and sex chromosomal aneuploidy.However,the value of QF-PCR in diagnosing chromosomal structural abnormalities is limited.In this article,we report a confusing QF-PCR finding in a pregnant woman who underwent amniocentesis.CASE SUMMARY The short tandem repeat marker AMXY(Xp22.2/Yp11.2)located on the sex chromosome exhibited a trisomic biallelic pattern,indicating that the karyotype of the fetus might be 47,XYY.Chromosome analysis performed on cultured amniocytes showed a normal male karyotype of the fetus.Copy number variation sequencing confirmed a 500 kb duplication at Yp11.2-Yp11.2(chrY:6610001_7110000)and a 250 kb duplication at Yp11.2-Yp11.2(chrY:7110001_7360000).CONCLUSION In conclusion,the comprehensive application of different methods could achieve a higher detection rate and accuracy for the prenatal diagnosis of chromosomal disorders through chromosomal testing.展开更多
An accurate and reasonable technique combining direct absorption spectroscopy and laser-induced fluorescence(LIF)methods is developed to quantitatively measure the concentrations of hydroxyl in CH;/air flat laminar ...An accurate and reasonable technique combining direct absorption spectroscopy and laser-induced fluorescence(LIF)methods is developed to quantitatively measure the concentrations of hydroxyl in CH;/air flat laminar flame. In our approach, particular attention is paid to the linear laser-induced fluorescence and absorption processes, and experimental details as well. Through measuring the temperature, LIF signal distribution and integrated absorption, spatially absolute OH concentrations profiles are successfully resolved. These experimental results are then compared with the numerical simulation. It is proved that the good quality of the results implies that this method is suitable for calibrating the OH-PLIF measurement in a practical combustor.展开更多
The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF(laserinduced fluorescence) in flame.The detailed physical models of spectral absorption lineshape broadening,c...The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF(laserinduced fluorescence) in flame.The detailed physical models of spectral absorption lineshape broadening,collisional transition and quenching at elevated pressure are built.The fine energy level structure of the OH molecule is illustrated to understand the process with laser-induced fluorescence emission and others in the case without radiation,which include collisional quenching,rotational energy transfer(RET),and vibrational energy transfer(VET).Based on these,some numerical results are achieved by simulations in order to evaluate the fluorescence yield at elevated pressure.These results are useful for understanding the real physical processes in OH-LIF technique and finding a way to calibrate the signal for quantitative measurement of OH concentration in a practical combustor.展开更多
In the preparation of this precursor tetraethlortho silicate (TEOS), sodium tungstate, ethyl alcohol, HCl and RECl3(RE=Eu,Tb) were mixed and then heated at 800 ℃ for 2 h, leading to a luminescent compound. The struct...In the preparation of this precursor tetraethlortho silicate (TEOS), sodium tungstate, ethyl alcohol, HCl and RECl3(RE=Eu,Tb) were mixed and then heated at 800 ℃ for 2 h, leading to a luminescent compound. The structure of the materials was characterized by TG-DTA and IR analysis, and the results indicate that the materials were in SiO2 network structure. Three-dimensional fluorescence spectra was used to characterize the luminescent properties of the materials. The luminescence property of doped and un-doped Eu3+or Tb3+ and Na2WO4 in silica materials were prepared and measured. The results show that good energy transfer from WO2-4 to Eu3+ ion, sensitized the luminescence intensity of Eu3+ remarkably. Tb3+ ion incorporated silica materials expressed the inverse energy transition from Tb3+ to WO2-4, however, we got the materials with homogeneous green blue fluorescent light. Finally, the energy transfer of WO2-4 and Eu3+, WO2-4 and Tb3+ were explained by energy levels diagram.展开更多
This study was to develop the real-time fluorescence quantitative PCR technique for detecting the ratoon stunting disease (RSD) in virus-free seedcane seedlings. Healthy tissue culture seedlings were obtained from s...This study was to develop the real-time fluorescence quantitative PCR technique for detecting the ratoon stunting disease (RSD) in virus-free seedcane seedlings. Healthy tissue culture seedlings were obtained from six plants of sugarcane ROC22, which had been confirmed RSD-positive by detecting the sugarcane juice, by employing the sugarcane seedlings production protocol. Real-time fluorescence quantitative PCR was used to detect RSD pathogens in tissue culture sam- pies. The results showed that target fragment of RSD pathogens was not found in all 10 samples in real-time fluorescence quantitative PCR, with the Ct values of 37 - 39. The healthy tissue culture sugarcane seedlings do not carry RSD pathogens, indicating that adopting healthy seedcane seedlings production technique could thoroughly get rid of RSD pathogens.展开更多
Objective: Multidrug resistance(MDR) is one of the most important reasons for treatment failure and recurrence of acute leukemia. Its manifestations are different in children with acute lymphoblastic leukemia(ALL...Objective: Multidrug resistance(MDR) is one of the most important reasons for treatment failure and recurrence of acute leukemia. Its manifestations are different in children with acute lymphoblastic leukemia(ALL) which may be due to different detection methods. This study was to detect the expression of MDR1 mRNA in bone marrow cells of children with ALL by real-time fluorescence- quantitative reverse transcription polymerase-chain reaction(FQ-RT-PCR), and combine minimal residual desease(MRD) detection by flow cytometry(FCM) and to study their relationship with treatment response and prognosis of ALL. Methods:The MDR1 mRNA levels in bone marrow cells from 67 children with ALL[28 had newly diagnosed disease, 27 had achieved complete remission(CR), 12 recurrent] and 22 children without leukemia were detected by FQ-RT-PCR. MRD was detected by FCM. The patients were observed for 9-101 months, with a median of 64 months. Results:Standard curves of human MDR1 and GAPDH genes were constructed successfully. MDR1 mRNA was detected in all children with a positive rate of 100%. The mRNA level of MDR1 was similar among the newly diagnosed ALL group, CR group, and control group(P 〉 0.05), but significantly higher in the recurrence group than that in newly diagnosed disease group and control group(0.50 ± 0.55 vs. 0.09 ± 0.26 and 0.12 ± 0.23, P〈 0.05). 54 ALL patients were followed up, and it was found that MDR1 mRNA level was significantly higher in ALL patients within 3 years duration than that of ALL patients with 3-6 years and over 6 years duration(0.63 ± 0.56 vs. 0.11 ± 0.12 and 0.04 ± 0.06, P〈 0.01). For the 28 children with newly diagnosed disease, the MDR1 mRNA level was similar between WBC 〉 50 ~ 109 group and WBC〈50 × 10^9 group(P〉 0.05). In the 33 CR patients, the MDR1 mRNA level was significantly higher in MRD〉10a group than that in MRD〈10a group(0.39 ± 0.47 vs. 0.03 ± 0.03, P 〈 0.05). Conclusion:The sensitivity and specificity of FQ-RT-PCR in detecting MDR1 mRNA in bone marrowy cells of children with ALL patients are high. MDR1 mRNA is expressed in children with and without leukemia. MDR1 mRNA is highly expressed in the CR ALL patients with high MRD, recurrence and short duration(within 3 years). Monitoring MRD and the MDR1 mRNA level might be helpful for individual treatment.展开更多
[ Objective] This study aimed to establish a simultaneous detection method of shrimp viruses by real-time fluorescence quantitative RT-PCR, to improve the efficiency of inspection and quarantine. [ Method] A novel rea...[ Objective] This study aimed to establish a simultaneous detection method of shrimp viruses by real-time fluorescence quantitative RT-PCR, to improve the efficiency of inspection and quarantine. [ Method] A novel real-time fluorescence quantitative RT-PCR assay was established and optimized for simultaneously detecting DNA/RNA of four shrimp viruses (WSSV, IHHNV, TSV and YHV ). [ Result] The optimized real-time fluorescence quantitative RT-PCR system gener- ated typical amplification curves with high amplification efficiencies (E = 1.06, 1.07, 0.92 and 0.92, respectively), good hnear relationship ( r = 1 ), uniform repeatability ( standard deviation = 0.05 - 0.46 ; variation coefficient = 0.26% - 1.62% ) and high sensitivity, exhibiting no significant differences compared with re- al-time fluorescence quantitative PCR (average error of Ct value = 0.04 -0.40; T = 0.53 -2.50; P 〉 0.05 ). The total detection time was about 1 h. [ Conclusion] The optimized real-time fluorescence quantitative RT-PCR system can be used for rapid detection of WSSV, IHHNV, TSV and YHV.展开更多
Objective: To establish the method of real time fluorescence quantitative RT-PCR for detecting the expression of Survivin mRNA in nasopharyngeat carcinoma (NPC) tissues. Methods: The total RNA was extracted from N...Objective: To establish the method of real time fluorescence quantitative RT-PCR for detecting the expression of Survivin mRNA in nasopharyngeat carcinoma (NPC) tissues. Methods: The total RNA was extracted from NPC cell line CNE-2 and tissues with Trizol and then been transcribed reversely to cDNA, a method of real time fluorescence quantitative RT-PCR for detecting the expression of Survivin mRNA in NPC tissues had been established, in which chronic nasopharyn-gitis patients' nasopharynx tissues treated as control group. Results: The expression of Survivin mRNA all could be detected either in CNE-2 cells, NPC tissues or in chronic nasopharyngitis patients' nasopharynx tissues, and there was higher the expression level of Survivin mRNA in NPC tissues than which in chronic nasopharyngitis patients' nasopharynx tissues, the difference was significant (P 〈 0.01). The expression of Survivin mRNA could be detected both in stage Ⅰ + Ⅱ and stage Ⅲ + Ⅳ NPC, and there was no significant difference in relative quantifications of gene expression between these two groups (P 〉 0.05). There was no relationship between Survivin mRNA expression and age and sex of NPC patients (P 〉 0.05). Conclusion: Real time fluorescence quantitative RT-PCR is a rapid, effective and high sensitive method for detecting the expression of Survivin mRNA in NPC tissues. The overexpression of Survivin mRNA may play some roles in pathogenesis of NPC.展开更多
Single-particle microbeam as a powerful tool can open a research field to find answers to many enigmas in radiobiology. A single-particle microbeam facility has been constructed at the Key Laboratory of Ion Beam Bioen...Single-particle microbeam as a powerful tool can open a research field to find answers to many enigmas in radiobiology. A single-particle microbeam facility has been constructed at the Key Laboratory of Ion Beam Bioengineering (LIBB), Chinese Academy of Sciences (CAS), China. However there has been less research activities in this field concerning the original process of the interaction between low-energy ions and complicated organisms. To address this challenge, an in situ multi-dimensional quantitative fluorescence microscopy system combined with the CAS-LIBB single-particle microbeam II endstation is proposed. In this article, the rationale, logistics and development of many aspects of the proposed system are discussed.展开更多
[Objective] This paper was to develop a fluorescence quantitative PCR method for detection of M. refringens in shellfish. [Method] A pair of primers and a TaqMan probe were designed and synthesized according to the co...[Objective] This paper was to develop a fluorescence quantitative PCR method for detection of M. refringens in shellfish. [Method] A pair of primers and a TaqMan probe were designed and synthesized according to the conserved gene sequences of M. refringens in GenBank, so as to develop a fluorescence quantitative PCR method for detection of M. refringens. The developed fluorescence quantitative PCR method was compared with conventional PCR detection. [Result] The fluorescence quantitative PCR could detect 40 template copies of plasmid DNA, and its sensitivity was 100 times higher than the conventional PCR. The detection results of Perkinsus sp, Haplosporidium sp, Aeromonas hydrophila, Pseudomonas fluorescens, Vibrio parahaemolyticu, Vibrio alginolyticu, Vibrio rluvialis and Vibrio mimicus were negtive. [Conclusion] The fluorescence quantitative PCR method for M. refringens established in this paper is specific, sensitive, rapid and quantitative with good repeatability, which can be used for clinical detection of M. refringens infection.展开更多
The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical ...The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.展开更多
According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by P...According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by PCR amplification. The products were ligated with pMD18- T vector and then transformed into bacteria DH5α for recombinant plasmid extraction. After PCR identification and sequencing, recombinant plasmid was used as a standard template to establish the standard curve of SYBR Green I fluorescence quantitative PCR. Sensitivity test, specificity test and repeatability test were also determined. The results indicated that there was a good linear relationship between threshold cycle of the standard curve and template concentration, R2 =0.997 6. Tm ranged from 82.3 to 82.9 ℃, while the sensitivity was 72.1 copies/μl with good specificity and repeatability. The developed SYBR Green I real-time quantitative PCR method to detect PPV VP2 gene laid the basis for further studies on patho- oenesis, early clinical diaonosis of this virus and quantitative analysis of PPV infection.展开更多
Although scientific and policy bodies have stated that nanomaterials are not intrinsically toxic, there is interest in evaluating if and how many engineered nanomaterials may do harm to the health of mankind and the e...Although scientific and policy bodies have stated that nanomaterials are not intrinsically toxic, there is interest in evaluating if and how many engineered nanomaterials may do harm to the health of mankind and the ecological environment. The interaction between nano-TiO2 and bovine serum albumin (BSA) was studied by using TDFS and UV methods in this research.展开更多
[ Objective ] This study aimed to establish a rapid and effective quarantine method of Koi herpes virus. [ Method] Primers and corresponding TaqMan probe were designed based on the conserved sequence of Koi herpes vir...[ Objective ] This study aimed to establish a rapid and effective quarantine method of Koi herpes virus. [ Method] Primers and corresponding TaqMan probe were designed based on the conserved sequence of Koi herpes virus (KHV) pol-ymerase gene (Sph) to establish a rapid and effective fluorescence quantitative PCR method for Koi herpes virus detection. The cell cultures were detected by using the established fluorescence quantitative PCR assay, and the results were com- pared with that of conventional PCR. [ Result] The sensitivity of fluorescence quantitative PCR was higher than that of conventional PCR. The minimum copy num- ber that could be detected was 1.6 - 102 copies/p.1. The established method was adopted for sample detection, and a reliable diagnostic result could be obtained within 4 h. [Conclusion] The established method is rapid, sensitive, specific and repeatable, which is conducive to the rapid detection of Koi herpes virus. Key words Koi herpes virus; Fluorescence quantitative PCR; Detection展开更多
The introduction of multi-methods of Geo-logging at wellsite has become the major measurement of oil & gas exploration. From the early stage of manually geo-logging to the modern mudlogging with new techonlogies o...The introduction of multi-methods of Geo-logging at wellsite has become the major measurement of oil & gas exploration. From the early stage of manually geo-logging to the modern mudlogging with new techonlogies of MWD, LWD and QFT etc. The new technologies have played very important roles in the exploring of oil & gas. Being one of the newest technology of mudlogging, QFT has been widely used in oilfield for about 3 years. When it is put in operation in some oilfields of China in 1997, its advantages in oil & gas detection at wellsite have been continuously recognized,especially in the detection of shows of light oil and condensed oil. A set of powerful classification standard of resource rock oil bearing grades and the interpretation standards have been summarized by the application of the quantitative fluorescencelogging techniques (QFT) in Basins of China, together with gas-logging data, and other information got from the Geo-logging procedures at wellsite.展开更多
A novel three-dimensional holographic vector of atomic interaction field(3D-HoVAIF) was used to describe the chemical structures of 23 benzoxazinone derivatives as antithrombotic drugs.Here a quantitative structure ...A novel three-dimensional holographic vector of atomic interaction field(3D-HoVAIF) was used to describe the chemical structures of 23 benzoxazinone derivatives as antithrombotic drugs.Here a quantitative structure activity relationship(QSAR) model was built by partial least-squares(PLS) regression.The estimation stability and prediction ability of the model were strictly analyzed by both internal and external validations.The correlation coefficients of established PLS model,leave-one-out(LOO) cross-validation,and predicted values versus experimental ones of external samples were R2=0.899,RCV2=0.854 and Qext2=0.868,respectively.These values indicated that the built PLS model had both favorable estimation stability and good prediction capabilities.Furthermore,the satisfactory results showed that 3D-HoVAIF could preferably express the information related to the biological activity of benzoxazinone derivatives.展开更多
Objective: In the prenatal screening, several different methods were used to detect the presence of group B streptococcus (GBS) infection, in this assay, the diagnostic value and clinical significance of the applicati...Objective: In the prenatal screening, several different methods were used to detect the presence of group B streptococcus (GBS) infection, in this assay, the diagnostic value and clinical significance of the application of realtime fluorescent PCR were explored. Methods: A total of 86 women with 35-37 weeks pregnancy were enrolled, vaginal secretion samples were collected. Fluorescence PCR, bacterial culture and gene sequencing were used to detect whether there was GBS infection, and the results obtained were compared and analyzed. Results: 10 subjects were detected to be positive for GBS by fluorescence PCR (the positive rate was 11.6%), however, only 4 cases were positive for GBS by bacterial culture method (the positive rate was 4.7%). There was a statistically significant difference in the positive rate between the two methods (P<0.01). Compared with the results of gene sequencing, the detection of GBS infection by fluorescence PCR has an accuracy of 95.2%, and the sensitivity was 90.9% with 100% specificity. Conclusion: The application of realtime fluorescence quantitative PCR for the detection of GBS infection is significantly better than the use of bacterial culture method. Compared with the gold standard method (gene sequencing method), its detection efficiency, accuracy, sensitivity and specificity are relatively high. In summary, PCR for prenatal screening of GBS is worthy of promotion in clinical practice.展开更多
Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitativ...Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitative fluorescence signal collection process was set in the extension stage.Results:Three-step amplification has the advantages of wide application range;improved accuracy;and reduced primer design requirements.Conclusion:The interference of non-specific amplification signals was effectively avoided,the melting curve plotting process was omitted,the reaction time was shortened,and the detection accuracy was improved.展开更多
基金Supported by Research Project of General Administration of Customs(2022HK126)Youth Science Foundation(2022D01B08).
文摘[Objective]The paper was to establish a fluorescence quantitative RT-PCR method for detection of equine arteritis virus(EAV).[Method]Primers and probes were developed for the EAV ORF7 gene sequence,and the reaction system was optimized.Standard curves were established,leading to the initial development of the EAV fluorescence quantitative RT-PCR assay.The accuracy,specificity,and sensitivity of this method were subsequently evaluated.[Result]The EAV fluorescence quantitative RT-PCR assay demonstrated optimal performance at an annealing temperature of 61 C,with a final concentration of primer and probe set at 0.6μmol/L.The plasmid standard demonstrated a strong linear correlation with Ct values within the range of 1.6×10^(7)-1.6×10^(2)copies/μL.The equation of the standard curve was determined to be y=-2.68x+32.88,with an R^(2) value of 0.9927.Consequently,the EAV fluorescence quantitative RT-PCR assay was successfully established.The methodology employed was effective in detecting EAV,Theileria equi,equine herpesvirus-1(EHV-1),equine herpesvirus-4(EHV-4),and equine influenza virus(EIV).The findings indicated that the method was specifically capable of detecting EAV,while the other pathogens tested yielded negative results.The method demonstrated a high degree of specificity.It was employed to detect the standard plasmid cRNA synthesized through in vitro transcription following a 10-fold dilution.The results indicated that the minimum detection limit of the method was 1.6×10^(2) copies/μL,and it exhibited high sensitivity.The coefficient of variation,both within and between groups,was maintained at 1.8%,indicating good reproducibility.In this study,the fluorescence quantitative RT-PCR assay developed was utilized alongside the EAV fluorescence quantitative RT-PCR assay established by previous researchers to analyze a total of 234 clinical samples.Both methods yielded a positive detection rate of 14.1%,and the coincidence rate between the two techniques was found to be 100%.[Conclusion]The fluorescence quantitative RT-PCR assay developed in this study offers a novel approach and concept for the prevention and control of equine viral arteritis(EVA).
文摘BACKGROUND Quantitative fluorescent polymerase chain reaction(QF-PCR)is a rapid prenatal diagnostic method for abnormalities on chromosomes 21,18,and 13 and sex chromosomal aneuploidy.However,the value of QF-PCR in diagnosing chromosomal structural abnormalities is limited.In this article,we report a confusing QF-PCR finding in a pregnant woman who underwent amniocentesis.CASE SUMMARY The short tandem repeat marker AMXY(Xp22.2/Yp11.2)located on the sex chromosome exhibited a trisomic biallelic pattern,indicating that the karyotype of the fetus might be 47,XYY.Chromosome analysis performed on cultured amniocytes showed a normal male karyotype of the fetus.Copy number variation sequencing confirmed a 500 kb duplication at Yp11.2-Yp11.2(chrY:6610001_7110000)and a 250 kb duplication at Yp11.2-Yp11.2(chrY:7110001_7360000).CONCLUSION In conclusion,the comprehensive application of different methods could achieve a higher detection rate and accuracy for the prenatal diagnosis of chromosomal disorders through chromosomal testing.
基金supported by the National Natural Science Foundation of China(Grant No.11272338)the Science and Technology on Scramjet Key Laboratory Funding,China(Grant No.STSKFKT 2013004)the China Scholarship Council
文摘An accurate and reasonable technique combining direct absorption spectroscopy and laser-induced fluorescence(LIF)methods is developed to quantitatively measure the concentrations of hydroxyl in CH;/air flat laminar flame. In our approach, particular attention is paid to the linear laser-induced fluorescence and absorption processes, and experimental details as well. Through measuring the temperature, LIF signal distribution and integrated absorption, spatially absolute OH concentrations profiles are successfully resolved. These experimental results are then compared with the numerical simulation. It is proved that the good quality of the results implies that this method is suitable for calibrating the OH-PLIF measurement in a practical combustor.
基金Project supported by the National Natural Science Foundation of China(Grant No.11272338)the Fund from the Science and Technology on Scramjet Key Laboratory,China(Grant No.STSKFKT2013004)
文摘The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF(laserinduced fluorescence) in flame.The detailed physical models of spectral absorption lineshape broadening,collisional transition and quenching at elevated pressure are built.The fine energy level structure of the OH molecule is illustrated to understand the process with laser-induced fluorescence emission and others in the case without radiation,which include collisional quenching,rotational energy transfer(RET),and vibrational energy transfer(VET).Based on these,some numerical results are achieved by simulations in order to evaluate the fluorescence yield at elevated pressure.These results are useful for understanding the real physical processes in OH-LIF technique and finding a way to calibrate the signal for quantitative measurement of OH concentration in a practical combustor.
基金Project supported by State Natural Science Foundation (20161001)Natural Science Foundation of Inner Mongolia Autonomous Region Science Commission (200508010206)
文摘In the preparation of this precursor tetraethlortho silicate (TEOS), sodium tungstate, ethyl alcohol, HCl and RECl3(RE=Eu,Tb) were mixed and then heated at 800 ℃ for 2 h, leading to a luminescent compound. The structure of the materials was characterized by TG-DTA and IR analysis, and the results indicate that the materials were in SiO2 network structure. Three-dimensional fluorescence spectra was used to characterize the luminescent properties of the materials. The luminescence property of doped and un-doped Eu3+or Tb3+ and Na2WO4 in silica materials were prepared and measured. The results show that good energy transfer from WO2-4 to Eu3+ ion, sensitized the luminescence intensity of Eu3+ remarkably. Tb3+ ion incorporated silica materials expressed the inverse energy transition from Tb3+ to WO2-4, however, we got the materials with homogeneous green blue fluorescent light. Finally, the energy transfer of WO2-4 and Eu3+, WO2-4 and Tb3+ were explained by energy levels diagram.
基金Supported by Special Funds for Basic Scientific Research of Guangxi Sugarcane Research Institute(G2009006,G2010006,G2009015)Sci-tech Research and Development Program of Guangxi Academy of Agricultural Sciences(200805)
文摘This study was to develop the real-time fluorescence quantitative PCR technique for detecting the ratoon stunting disease (RSD) in virus-free seedcane seedlings. Healthy tissue culture seedlings were obtained from six plants of sugarcane ROC22, which had been confirmed RSD-positive by detecting the sugarcane juice, by employing the sugarcane seedlings production protocol. Real-time fluorescence quantitative PCR was used to detect RSD pathogens in tissue culture sam- pies. The results showed that target fragment of RSD pathogens was not found in all 10 samples in real-time fluorescence quantitative PCR, with the Ct values of 37 - 39. The healthy tissue culture sugarcane seedlings do not carry RSD pathogens, indicating that adopting healthy seedcane seedlings production technique could thoroughly get rid of RSD pathogens.
基金This work was supported by Science Project from Science and Tech- nology Department of HuBei province(2006AA301B56-3)
文摘Objective: Multidrug resistance(MDR) is one of the most important reasons for treatment failure and recurrence of acute leukemia. Its manifestations are different in children with acute lymphoblastic leukemia(ALL) which may be due to different detection methods. This study was to detect the expression of MDR1 mRNA in bone marrow cells of children with ALL by real-time fluorescence- quantitative reverse transcription polymerase-chain reaction(FQ-RT-PCR), and combine minimal residual desease(MRD) detection by flow cytometry(FCM) and to study their relationship with treatment response and prognosis of ALL. Methods:The MDR1 mRNA levels in bone marrow cells from 67 children with ALL[28 had newly diagnosed disease, 27 had achieved complete remission(CR), 12 recurrent] and 22 children without leukemia were detected by FQ-RT-PCR. MRD was detected by FCM. The patients were observed for 9-101 months, with a median of 64 months. Results:Standard curves of human MDR1 and GAPDH genes were constructed successfully. MDR1 mRNA was detected in all children with a positive rate of 100%. The mRNA level of MDR1 was similar among the newly diagnosed ALL group, CR group, and control group(P 〉 0.05), but significantly higher in the recurrence group than that in newly diagnosed disease group and control group(0.50 ± 0.55 vs. 0.09 ± 0.26 and 0.12 ± 0.23, P〈 0.05). 54 ALL patients were followed up, and it was found that MDR1 mRNA level was significantly higher in ALL patients within 3 years duration than that of ALL patients with 3-6 years and over 6 years duration(0.63 ± 0.56 vs. 0.11 ± 0.12 and 0.04 ± 0.06, P〈 0.01). For the 28 children with newly diagnosed disease, the MDR1 mRNA level was similar between WBC 〉 50 ~ 109 group and WBC〈50 × 10^9 group(P〉 0.05). In the 33 CR patients, the MDR1 mRNA level was significantly higher in MRD〉10a group than that in MRD〈10a group(0.39 ± 0.47 vs. 0.03 ± 0.03, P 〈 0.05). Conclusion:The sensitivity and specificity of FQ-RT-PCR in detecting MDR1 mRNA in bone marrowy cells of children with ALL patients are high. MDR1 mRNA is expressed in children with and without leukemia. MDR1 mRNA is highly expressed in the CR ALL patients with high MRD, recurrence and short duration(within 3 years). Monitoring MRD and the MDR1 mRNA level might be helpful for individual treatment.
文摘[ Objective] This study aimed to establish a simultaneous detection method of shrimp viruses by real-time fluorescence quantitative RT-PCR, to improve the efficiency of inspection and quarantine. [ Method] A novel real-time fluorescence quantitative RT-PCR assay was established and optimized for simultaneously detecting DNA/RNA of four shrimp viruses (WSSV, IHHNV, TSV and YHV ). [ Result] The optimized real-time fluorescence quantitative RT-PCR system gener- ated typical amplification curves with high amplification efficiencies (E = 1.06, 1.07, 0.92 and 0.92, respectively), good hnear relationship ( r = 1 ), uniform repeatability ( standard deviation = 0.05 - 0.46 ; variation coefficient = 0.26% - 1.62% ) and high sensitivity, exhibiting no significant differences compared with re- al-time fluorescence quantitative PCR (average error of Ct value = 0.04 -0.40; T = 0.53 -2.50; P 〉 0.05 ). The total detection time was about 1 h. [ Conclusion] The optimized real-time fluorescence quantitative RT-PCR system can be used for rapid detection of WSSV, IHHNV, TSV and YHV.
基金the National Natural Science Foundation of China (No. 30460145).
文摘Objective: To establish the method of real time fluorescence quantitative RT-PCR for detecting the expression of Survivin mRNA in nasopharyngeat carcinoma (NPC) tissues. Methods: The total RNA was extracted from NPC cell line CNE-2 and tissues with Trizol and then been transcribed reversely to cDNA, a method of real time fluorescence quantitative RT-PCR for detecting the expression of Survivin mRNA in NPC tissues had been established, in which chronic nasopharyn-gitis patients' nasopharynx tissues treated as control group. Results: The expression of Survivin mRNA all could be detected either in CNE-2 cells, NPC tissues or in chronic nasopharyngitis patients' nasopharynx tissues, and there was higher the expression level of Survivin mRNA in NPC tissues than which in chronic nasopharyngitis patients' nasopharynx tissues, the difference was significant (P 〈 0.01). The expression of Survivin mRNA could be detected both in stage Ⅰ + Ⅱ and stage Ⅲ + Ⅳ NPC, and there was no significant difference in relative quantifications of gene expression between these two groups (P 〉 0.05). There was no relationship between Survivin mRNA expression and age and sex of NPC patients (P 〉 0.05). Conclusion: Real time fluorescence quantitative RT-PCR is a rapid, effective and high sensitive method for detecting the expression of Survivin mRNA in NPC tissues. The overexpression of Survivin mRNA may play some roles in pathogenesis of NPC.
文摘Single-particle microbeam as a powerful tool can open a research field to find answers to many enigmas in radiobiology. A single-particle microbeam facility has been constructed at the Key Laboratory of Ion Beam Bioengineering (LIBB), Chinese Academy of Sciences (CAS), China. However there has been less research activities in this field concerning the original process of the interaction between low-energy ions and complicated organisms. To address this challenge, an in situ multi-dimensional quantitative fluorescence microscopy system combined with the CAS-LIBB single-particle microbeam II endstation is proposed. In this article, the rationale, logistics and development of many aspects of the proposed system are discussed.
文摘[Objective] This paper was to develop a fluorescence quantitative PCR method for detection of M. refringens in shellfish. [Method] A pair of primers and a TaqMan probe were designed and synthesized according to the conserved gene sequences of M. refringens in GenBank, so as to develop a fluorescence quantitative PCR method for detection of M. refringens. The developed fluorescence quantitative PCR method was compared with conventional PCR detection. [Result] The fluorescence quantitative PCR could detect 40 template copies of plasmid DNA, and its sensitivity was 100 times higher than the conventional PCR. The detection results of Perkinsus sp, Haplosporidium sp, Aeromonas hydrophila, Pseudomonas fluorescens, Vibrio parahaemolyticu, Vibrio alginolyticu, Vibrio rluvialis and Vibrio mimicus were negtive. [Conclusion] The fluorescence quantitative PCR method for M. refringens established in this paper is specific, sensitive, rapid and quantitative with good repeatability, which can be used for clinical detection of M. refringens infection.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11675019 and 11875087).
文摘The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.
文摘According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by PCR amplification. The products were ligated with pMD18- T vector and then transformed into bacteria DH5α for recombinant plasmid extraction. After PCR identification and sequencing, recombinant plasmid was used as a standard template to establish the standard curve of SYBR Green I fluorescence quantitative PCR. Sensitivity test, specificity test and repeatability test were also determined. The results indicated that there was a good linear relationship between threshold cycle of the standard curve and template concentration, R2 =0.997 6. Tm ranged from 82.3 to 82.9 ℃, while the sensitivity was 72.1 copies/μl with good specificity and repeatability. The developed SYBR Green I real-time quantitative PCR method to detect PPV VP2 gene laid the basis for further studies on patho- oenesis, early clinical diaonosis of this virus and quantitative analysis of PPV infection.
基金Suppoted by National Nature Science Foundation of China (Grant Nos. 41130746, 41272371)the Doctor Foundation of SWUST of China (Grant No. 11zx7139)
文摘Although scientific and policy bodies have stated that nanomaterials are not intrinsically toxic, there is interest in evaluating if and how many engineered nanomaterials may do harm to the health of mankind and the ecological environment. The interaction between nano-TiO2 and bovine serum albumin (BSA) was studied by using TDFS and UV methods in this research.
基金Supported by Project of Jilin Province Science and Technology Commission(20080218)
文摘[ Objective ] This study aimed to establish a rapid and effective quarantine method of Koi herpes virus. [ Method] Primers and corresponding TaqMan probe were designed based on the conserved sequence of Koi herpes virus (KHV) pol-ymerase gene (Sph) to establish a rapid and effective fluorescence quantitative PCR method for Koi herpes virus detection. The cell cultures were detected by using the established fluorescence quantitative PCR assay, and the results were com- pared with that of conventional PCR. [ Result] The sensitivity of fluorescence quantitative PCR was higher than that of conventional PCR. The minimum copy num- ber that could be detected was 1.6 - 102 copies/p.1. The established method was adopted for sample detection, and a reliable diagnostic result could be obtained within 4 h. [Conclusion] The established method is rapid, sensitive, specific and repeatable, which is conducive to the rapid detection of Koi herpes virus. Key words Koi herpes virus; Fluorescence quantitative PCR; Detection
文摘The introduction of multi-methods of Geo-logging at wellsite has become the major measurement of oil & gas exploration. From the early stage of manually geo-logging to the modern mudlogging with new techonlogies of MWD, LWD and QFT etc. The new technologies have played very important roles in the exploring of oil & gas. Being one of the newest technology of mudlogging, QFT has been widely used in oilfield for about 3 years. When it is put in operation in some oilfields of China in 1997, its advantages in oil & gas detection at wellsite have been continuously recognized,especially in the detection of shows of light oil and condensed oil. A set of powerful classification standard of resource rock oil bearing grades and the interpretation standards have been summarized by the application of the quantitative fluorescencelogging techniques (QFT) in Basins of China, together with gas-logging data, and other information got from the Geo-logging procedures at wellsite.
基金supported by the Natural Science Foundation of Shaanxi Province (2009JQ2005)Foundation of Educational Commission of Shaanxi Province (09JK358) Graduate Innovation Fund of Shaanxi University of Science and Technology
文摘A novel three-dimensional holographic vector of atomic interaction field(3D-HoVAIF) was used to describe the chemical structures of 23 benzoxazinone derivatives as antithrombotic drugs.Here a quantitative structure activity relationship(QSAR) model was built by partial least-squares(PLS) regression.The estimation stability and prediction ability of the model were strictly analyzed by both internal and external validations.The correlation coefficients of established PLS model,leave-one-out(LOO) cross-validation,and predicted values versus experimental ones of external samples were R2=0.899,RCV2=0.854 and Qext2=0.868,respectively.These values indicated that the built PLS model had both favorable estimation stability and good prediction capabilities.Furthermore,the satisfactory results showed that 3D-HoVAIF could preferably express the information related to the biological activity of benzoxazinone derivatives.
文摘Objective: In the prenatal screening, several different methods were used to detect the presence of group B streptococcus (GBS) infection, in this assay, the diagnostic value and clinical significance of the application of realtime fluorescent PCR were explored. Methods: A total of 86 women with 35-37 weeks pregnancy were enrolled, vaginal secretion samples were collected. Fluorescence PCR, bacterial culture and gene sequencing were used to detect whether there was GBS infection, and the results obtained were compared and analyzed. Results: 10 subjects were detected to be positive for GBS by fluorescence PCR (the positive rate was 11.6%), however, only 4 cases were positive for GBS by bacterial culture method (the positive rate was 4.7%). There was a statistically significant difference in the positive rate between the two methods (P<0.01). Compared with the results of gene sequencing, the detection of GBS infection by fluorescence PCR has an accuracy of 95.2%, and the sensitivity was 90.9% with 100% specificity. Conclusion: The application of realtime fluorescence quantitative PCR for the detection of GBS infection is significantly better than the use of bacterial culture method. Compared with the gold standard method (gene sequencing method), its detection efficiency, accuracy, sensitivity and specificity are relatively high. In summary, PCR for prenatal screening of GBS is worthy of promotion in clinical practice.
文摘Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitative fluorescence signal collection process was set in the extension stage.Results:Three-step amplification has the advantages of wide application range;improved accuracy;and reduced primer design requirements.Conclusion:The interference of non-specific amplification signals was effectively avoided,the melting curve plotting process was omitted,the reaction time was shortened,and the detection accuracy was improved.