期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
1
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
原文传递
Early outcomes of vision and objective visual quality analysis after cataract surgery with trifocal intraocular lens implantation 被引量:3
2
作者 Mei-Fang Chu Na Hui +4 位作者 Cong-Yi Wang Lei Yu Bo Ma Yan Li Cheng Pei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第10期1575-1581,共7页
AIM: To investigate the early outcomes of vision, objective visual quality and their correlation after cataract surgery with trifocal intraocular lens implantation.METHODS: The visual examination and objective visual ... AIM: To investigate the early outcomes of vision, objective visual quality and their correlation after cataract surgery with trifocal intraocular lens implantation.METHODS: The visual examination and objective visual quality analysis using Optical Quality Analysis System(OQAS) at 1 mo and 3 mo, and defocus curve examination at 3 mo were performed in 20 patients(27 eyes) after phacoemulsification combined with trifocal intraocular lens implantation surgery.RESULTS: The uncorrected distant(UD), intermediate and near visual acuity(VA) were significantly improved after surgery(P<0.001). UDVA at 1 mo after the surgery was slightly better than that after 3 mo(P=0.026). The defocus curve after 3 mo indicated that the peak of distant vision was close to 0 logMAR, and UDVA was lower than 0.3 logMAR in the range of-1.5 D to-3.0 D. The modulation transfer function(MTF) cutoff frequency, strehl ratio(SR), Optical Quality Analysis System values(OVs), includes OV100, OV20 and OV9 after the surgery were significantly better than before surgery(P<0.001), but the objective scattering index(OSI) was significantly decreased(P<0.001). UDVA at 3 mo after the surgery had correlations with MTF cutoff, OSI, OV100 and OV20(r=-0.400, 0.431,-0.437,-0.411, P=0.039, 0.025, 0.023, 0.033). The uncorrected intermediate VA after 3 mo of the surgery had correlations with OSI and OV100(r=0.478,-0.411, P=0.012, 0.033). CONCLUSION: Trifocal intraocular lens implantation can provide good distant, intermediate and near VA, and the vision shows a well correlation with objective visual quality during early surgery. 展开更多
关键词 visual quality trifocal INTRAOCULAR LENS VISION correlation
原文传递
Residual Astigmatism Threshold and Patient Satisfaction with Bifocal, Trifocal and Extended Range of Vision Intraocular Lenses (IOLs) 被引量:7
3
作者 Francesco Carones 《Open Journal of Ophthalmology》 2017年第1期1-7,共7页
Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of pat... Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of patients with implantation of four different MIOLs: AcrySof ReSTOR +2.5 D (20 eyes), AcrySof ReSTOR +3.0 D (20 eyes), AcrySof Panoptix (20 eyes) (Alcon Laboratories, Inc., Fort Worth, TX, USA), and Tecnis Symfony ZRX00 (Abbott Medical Optics, Santa Ana, USA) (20 eyes). Patients were followed up for 3 months after surgery. Major parameters were uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective refraction and patient satisfaction. Results: Differences between IOLs with regard to the impact of the cylinder sign and axis on visual acuity and patient satisfaction were not significant. With mild added negative cylinder, AcrySof ReSTOR +2.5 D and Tecnis Symfony IOLs maintained the baseline visual acuity, while it was mildly reduced with AcrySof ReSTOR +3.0 D and Panoptix IOLs. With moderate induced cylinder, the Tecnis Symfony IOL maintained good visual acuity and patient associated satisfaction. Panoptix IOL was the IOL most affected by the induced astigmatism with regard to dissatisfaction and visual acuity. The highest tolerance to the astigmatic distortion and blurriness induced with a -1.50 D cylinder was obtained with the Tecnis Symfony IOL. Tecnis Symfony IOL showed less dissatisfaction and less reduction of visual acuity than the other MIOLs. Conclusion: Simulated residual cylinders after the implantation of the Tecnis Symfony IOL up to 1.0 D have a very mild and not clinically relevant impact on visual acuity or patient satisfaction. The ERV IOL showed a better tolerance to unexpected postoperative residual errors than diffractive bifocal and trifocal IOLs. 展开更多
关键词 MULTIFOCAL IOL ASTIGMATISM Tolerance Bifocal trifocal Extended Range of VISION TECNIS Symfony Panoptix ACRYSOF RESTOR
下载PDF
Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up 被引量:3
4
作者 Peter Mojzis Lucia Kukuckova +2 位作者 Katarina Majerova Peter Ziak David P.Pi?ero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1528-1533,共6页
AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL) during a 12-month follow-up.METHODS:Prospective comparative study including 75 eyes of 38 patients(44-70 ... AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL) during a 12-month follow-up.METHODS:Prospective comparative study including 75 eyes of 38 patients(44-70 y) undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes) or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12 mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm) was significantly better in the trifocal group during all follow-up(P≤0.004) as well as 6-month uncorrected near(P=0.008) and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P<0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision. 展开更多
关键词 trifocal intraocular lens bifocal intraocular lens defocus curve contrast sensitivity cataract surgery
原文传递
Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism 被引量:2
5
作者 Merve Bozkurt Gencer Hikmet Basmak +1 位作者 Erdogan Yasar Ozkan Onal 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第12期1876-1881,共6页
AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A t... AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group. 展开更多
关键词 CATARACT trifocal toric intraocular lens bifocal toric intraocular lens STEREOPSIS SATISFACTION
原文传递
Trifocal distraction osteogenesis for reconstruction of skull defect 被引量:1
6
作者 Ke Ke Hai-Song Xu Zhi-Hong Fan 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第8期644-648,共5页
Objective: To apply trifocal distraction osteogenesis in canine model of skull segmental defects and to provide reference for clinical treatment. Methods: Six labrador dogs were selected in this study and divided into... Objective: To apply trifocal distraction osteogenesis in canine model of skull segmental defects and to provide reference for clinical treatment. Methods: Six labrador dogs were selected in this study and divided into observation group and control group randomly. Each group contained 3 dogs. Skull segmental defects models were established by surgery, and dogs in bservation group received trifocal distraction osteogenesis treatment. Bone density was observed and compared between two groups during treatment. Results: There were no significant difference in bone density between two groups on th 1st day ( P>0.05). The bone density of observation group on the 30th day, and 60th day were higher than that of control group ( P<0.01). Conclusions: Trifocal distraction osteogenesis has significant clinical effect, and it would be widely used in clinical treatment. 展开更多
关键词 trifocal DISTRACTION OSTEOGENESIS SKULL SEGMENTAL DEFECTS DOG
下载PDF
Visual quality after implantation of trifocal intraocular lenses in highly myopic eyes with different axial lengths 被引量:1
7
作者 Hui Liu Fang-Fang Li +1 位作者 Hai-Jun Xia Jin Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第3期371-377,共7页
AIM:To analyze postoperative clinical results after implantation of trifocal intraocular lenses(IOLs)in highly myopic eyes with different axial lengths(ALs).METHODS:This retrospective study describes 61 eyes of 44 pat... AIM:To analyze postoperative clinical results after implantation of trifocal intraocular lenses(IOLs)in highly myopic eyes with different axial lengths(ALs).METHODS:This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs(AT LISA tri 839 MP).Twenty-one eyes(15 patients)were included in the AL<26 mm group,19 eyes(13 patients)in the AL≥26 mm and<28 mm group,and 21 eyes(16 patients)in the AL≥28 mm group.Postoperative outcomes,including corrected and uncorrected distance visual acuity(UDVA),intermediate and near visual acuity at 167 cd/m2 luminance,depth of focus at 85 cd/m2 luminance,and objective optical quality parameters assessed using the Optical Quality Analysis System(OQAS),were compared among the groups at 3 mo.RESULTS:There were no significant differences in the mean UDVA,uncorrected intermediate visual acuity,uncorrected near visual acuity,corrected distance visual acuity,distance-corrected intermediate visual acuity,and distance-corrected near visual acuity(DCNVA)among the three groups(P>0.05).Better near and intermediate visual acuity(from-1.5 D to-3.0 D)were noted on the defocus curve of the AL<26 mm group(P<0.01 vs AL≥28 mm group).Significantly higher objective scatter index(OSI)values and lower modulation transfer function(MTF)cut-off values,Strehl ratio(SR),and OQAS values(OVs)were observed in the AL≥28 mm group(P<0.01 vs AL<26 mm group).All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of-2.5 D(P<0.05 to P<0.01).CONCLUSION:Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs.However,the near vision decreases in the extremely myopic eyes at lower luminance,which is associated with the lower objective optical quality in these eyes. 展开更多
关键词 CATARACT trifocal IOL OQAS high myopia
原文传递
Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens 被引量:1
8
作者 Na Hui Mei-Fang Chu +3 位作者 Yan Li Cong-Yi Wang Lei Yu Bo Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第9期1460-1467,共8页
·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative stu... ·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency. 展开更多
关键词 trifocal intraocular lens rotationally asymmetric multifocal intraocular lens visual quality contrast sensitivity
原文传递
Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation 被引量:1
9
作者 Shu-Yang Chen Chen Xie +1 位作者 Yang Wang Ye Shen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1239-1242,共4页
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien... Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extra- 展开更多
关键词 ICL IOL Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation
原文传递
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism
10
作者 Paz Orts-Vila Salvador Aguilar-Corcoles +3 位作者 Cristina Tello-Elordi María Ramos-Alzamora Robert Montés-Mico Pedro Taná-Rivero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第10期1567-1573,共7页
AIM:To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens(IOL)in eyes with low degrees of corneal astigmatism.METHODS:Twenty-six eyes of 22 pat... AIM:To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens(IOL)in eyes with low degrees of corneal astigmatism.METHODS:Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL(FineVision PODFT,PhysIOL s.a.,Liege,Belgium)were enrolled.Phacoemulsification with femtosecond laser,capsular tension ring insertion and intraoperative aberrometry were performed in all cases.All IOLs used showed a cylinder power of 1.00 D.Main outcome measures were refractive error and corrected-distance visual acuity(CDVA)and uncorrected-distance visual acuity(UDVA)values.Eyes were evaluated at 4 mo post-surgery.RESULTS:Totally 50%of eyes showed a spherical equivalent(SE)within±0.13 D and all of them within±0.50 D.The mean SE and refractive cylinder were-0.02±0.23 and-0.16±0.22 D,respectively.Vector analysis revealed that 100%of eyes were within±0.50 D for the SE and cylindrical components(J0 and J45).Refractive changes were not correlated with keratometric changes(P>0.05)showing that the reduction in astigmatism comes from the trifocal toric IOL.Of 81%and 96%of eyes showed UDVA and CDVA of 20/20,respectively.The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.97±0.05 and 0.99±0.02(about 20/20),respectively.CONCLUSION:Our study suggests that the use of this trifocal toric IOL in patients with low amount of astigmatism provides accurate refractive outcomes and enables them to achieve excellent visual acuity. 展开更多
关键词 TORIC trifocal intraocular lens PHACOEMULSIFICATION CATARACT ASTIGMATISM
原文传递
Trifocal Tensor Based Feature Matching Algorithm
11
作者 Mingwei Shao Pan Wang 《Journal of Beijing Institute of Technology》 EI CAS 2020年第4期484-488,共5页
Feature matching is of significance in the field of computer vision.In this paper,a trifocal tensor based feature matching algorithm is proposed for three views,including a trinocular vision system.Initial matching po... Feature matching is of significance in the field of computer vision.In this paper,a trifocal tensor based feature matching algorithm is proposed for three views,including a trinocular vision system.Initial matching point-pairs can be determined according to generic matching algorithms,on which an initial trifocal tensor of three views can be confirmed.Then the initial matching point-pairs should be re-selected.Meanwhile,the trifocal tensor will be recomputed.Iteratively,the optimized trifocal tensor can be obtained.Compatible fundamental matrix of every two views can be determined.Furthermore,in the trinocular vision sensor,the trifocal tensor can be calculated based on the intrinsic parameter matrix of each camera.With the strict constraint provided by the trifocal tensor,feature matching results will be optimized.Experiments show that our proposed algorithm has the characteristics of feasibility and precision. 展开更多
关键词 OPTICS trifocal tensor feature matching
下载PDF
Visual and refractive outcomes following implantation of a new trifocal intraocular lens 被引量:1
12
作者 Michael Lawless Chris Hodge +5 位作者 Joe Reich Lewis Levitz Uday K.Bhatt Colm McAlinden Kate Roberts Timothy V.Roberts 《Eye and Vision》 SCIE 2017年第1期42-47,共6页
Background:Independence from all optical aids,and freedom from unwanted symptoms,following cataract and lens surgery remains the ultimate goal of both patient and surgeon.The development of trifocal IOL technology pro... Background:Independence from all optical aids,and freedom from unwanted symptoms,following cataract and lens surgery remains the ultimate goal of both patient and surgeon.The development of trifocal IOL technology provides an ever-increasing range of options.The purpose of our study is to understand the predictability,safety and efficacy of a new trifocal intraocular lens(IOL)following cataract or refractive lens exchange(RLE)surgery.Methods:This was a retrospective consecutive case series of patients undergoing cataract extraction or RLE followed by implantation of the Alcon IQ Panoptix IOL.Pre and postoperative refractive and visual parameters were recorded and evaluated.As the cohort followed a normal distribution,standard parametric tests were used.Paired t-test was used to compare the difference between target and postoperative refractive errors.The incidence of intraoperative and postoperative complications was also reported.Results:The IOL was implanted in 66 eyes of 33 patients.Mean postoperative spherical equivalent(SE)refraction was-0.08±0.25 dioptres(D).This was not significantly different from the target refraction(p=0.841).Sixty-five percent of patients were within±0.25 D of the target SE refraction with 100%within±0.50 D of intended correction.Mean postoperative uncorrected distance visual acuity(UDVA)was 0.01±0.10 LogMAR.All patients achieved an unaided distance acuity of 20/40 or better postoperatively.Binocularly,100%saw 0.20 LogMAR or better at near without correction and 88.9%achieved this level for uncorrected intermediate visual acuity.No intraoperative complications were noted.Five patients complained of moderate haloes in the early postoperative period.Conclusion:The AcrySof IQ Panoptix IOL provides functional uncorrected visual acuity at distance,intermediate and near positions.Our results remain equivalent with existing trifocal IOL outcomes and provide surgeons with a further IOL alternative for the patient motivated to obtain true spectacle independence.Surgeons should consider individual reading and working requirements when counselling patients preoperatively to optimise postoperative patient satisfaction. 展开更多
关键词 trifocal trifocal IOL CATARACT Refractive lens exchange
原文传递
A More Natural Way of Seeing: Visual Performance of Three Presbyopia Correcting Intraocular Lenses 被引量:2
13
作者 Amir Hamid Arif Sokwala 《Open Journal of Ophthalmology》 2016年第3期176-183,共9页
Purpose: To compare the visual and refractive outcomes, patient satisfaction and spectacle independence between three novel designs of diffractive IOLs. Method: Prospective study including 150 patients with implantati... Purpose: To compare the visual and refractive outcomes, patient satisfaction and spectacle independence between three novel designs of diffractive IOLs. Method: Prospective study including 150 patients with implantation of three IOLs: trifocal diffractive IOL AT LISA tri 839 MP (ATLISA, n = 50), trifocal diffractive IOL PhysIOL FineVision (FineVision, n = 50) and the extended range of vision IOL Tecnis Symfony ZRX00 (Symfony, n = 50). Patients were followed up for 6 months after surgery. Major parameters were monocular and binocular uncorrected (UDVA) and corrected (CDVA) distance, uncorrected (UIVA) and distance corrected (DCIVA) intermediate (80 cm), and uncorrected (UNVA) and distance corrected (DCNVA) near (40 cm) visual acuities (UNVA), contrast sensitivity (CS), defocus curve as well as patient satisfaction and spectacle use. Results: Mean postoperative decimal UDVA was 1.01 for Symfony, 0.96 for ATLISA and 0.95 for the FineVision IOL. Postoperative UIVA was 0.95 with Symfony, 0.72 with ATLISA and 0.85 with the FineVision IOL. Postoperative UNVA was 0.96 with the FineVision, 0.72 with the ATLISA and 0.63 with the Symfony IOL. The Symfony defocus curve showed the smoothest profile. Mean mesopic CS was 0.84 log units with the Symfony, 0.83 with the ATLISA (0.83) and 0.65 with the FineVision IOL. Mean photopic CS with the Symfony, ATLISA and FineVision was 1.05, 0.85 and 0.69 log units, respectively. Twenty percent of the patients with the ATLISA and FineVision IOLs and 5.6% of the Symfony patients reported halos and glare as troublesome or disabling. Reading glasses were frequently used by 5.6% of the Symfony patients. All patients with the trifocal IOLs reported to be spectacle-free for any distance. Conclusion: All 3 IOLs produce excellent results with high levels of spectacle independence. The Symfony produces better levels of distance and intermediate visual acuity, whereas the trifocal IOLs produced better near vision. Higher frequency of dysphotopsia was seen with the trifocal IOLs. 展开更多
关键词 Extended Range of Vision Tecnis Symfony trifocal Defocus Curve Visual Outcome
下载PDF
Multifocal and extended depth of focus intraocular lenses
14
作者 Georgios Kondylis Olga Klavdianou Sotiria Palioura 《Annals of Eye Science》 2019年第1期13-18,共6页
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number... Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL. 展开更多
关键词 Cataract surgery quality of vision intraocular lens implantation trifocal intraocular lens bifocal intraocular lens
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部