Based on the Dikken analytical calculation method of wellbore pressure loss under single-phase fluid and turbulent flow conditions, the correlation model between horizontal well output and horizontal section length an...Based on the Dikken analytical calculation method of wellbore pressure loss under single-phase fluid and turbulent flow conditions, the correlation model between horizontal well output and horizontal section length and horizontal section distributed pressure difference is constructed. The influence degree of wellbore pressure loss on daily oil production of horizontal well, horizontal section pressure and production effect of horizontal well under different horizontal well lengths is analyzed, which provides certain reference for the design of horizontal well length and well layout.展开更多
Heat transfer from electrical and electronics component is essential for better performance of that electrical system,The maximum heat transfer from that system results long period durability.In most of the system bas...Heat transfer from electrical and electronics component is essential for better performance of that electrical system,The maximum heat transfer from that system results long period durability.In most of the system base provided for equipments are very small and placed in a very complicated position.so heat transfer by forced convection is not easy for that purpose.The heat transfer by natural convection is the familiar technique used in electronics cooling;there is huge group of apparatus that lends itself to natural convection.This category consist of stand-alone correspondence such as modems and small computers having an array of printed circuit boards(PCB)accumulate within an area.Natural convection heat transfer in heated horizontal duct drive away heat from the interior surface is offered.The duct is open-ended and round in cross section.The test section is heated by provision of heating coils,where constant wall heat flux mentioned.Heat transfer experiment is carried out for channel of 50 mm.internal diameter and 4 mm thickness with length 600 mm.Ratios of length to diameter of the channel are taken as L/D=12.Wall heat fluxes maintained at q//=300 W/m2 to 3150 W/m2.A methodical investigational record for the local steady state natural convection heat transfer activities is obtained.The wall heating condition on local steady-state heat transfer phenomena are studied.The present experimental data is compared with the existing theoretical and experimental results for the cases of vertical smooth tubes.展开更多
文摘Based on the Dikken analytical calculation method of wellbore pressure loss under single-phase fluid and turbulent flow conditions, the correlation model between horizontal well output and horizontal section length and horizontal section distributed pressure difference is constructed. The influence degree of wellbore pressure loss on daily oil production of horizontal well, horizontal section pressure and production effect of horizontal well under different horizontal well lengths is analyzed, which provides certain reference for the design of horizontal well length and well layout.
文摘Heat transfer from electrical and electronics component is essential for better performance of that electrical system,The maximum heat transfer from that system results long period durability.In most of the system base provided for equipments are very small and placed in a very complicated position.so heat transfer by forced convection is not easy for that purpose.The heat transfer by natural convection is the familiar technique used in electronics cooling;there is huge group of apparatus that lends itself to natural convection.This category consist of stand-alone correspondence such as modems and small computers having an array of printed circuit boards(PCB)accumulate within an area.Natural convection heat transfer in heated horizontal duct drive away heat from the interior surface is offered.The duct is open-ended and round in cross section.The test section is heated by provision of heating coils,where constant wall heat flux mentioned.Heat transfer experiment is carried out for channel of 50 mm.internal diameter and 4 mm thickness with length 600 mm.Ratios of length to diameter of the channel are taken as L/D=12.Wall heat fluxes maintained at q//=300 W/m2 to 3150 W/m2.A methodical investigational record for the local steady state natural convection heat transfer activities is obtained.The wall heating condition on local steady-state heat transfer phenomena are studied.The present experimental data is compared with the existing theoretical and experimental results for the cases of vertical smooth tubes.