The ultrasonic nebulization extraction(UNE) was developed and applied to the extraction of volatile components from traditional Chinese patent medicine Xiaoyao Pills. Several parameters of ultrasonic nebulization ex...The ultrasonic nebulization extraction(UNE) was developed and applied to the extraction of volatile components from traditional Chinese patent medicine Xiaoyao Pills. Several parameters of ultrasonic nebulization extraction including the sample particle size, solvent volume, extraction time and ultrasonic power were studied and selected. As a result, 2.4 g of sample with particle size of 80 mesh was extracted with 15 mL of n-hexane for 20 min at an ultrasonic power of 35 W. The volatile components were analyzed by gas chromatography-mass spectrometry (GC-MS) under the optimal conditions and 57 compounds were identified. The precision, repeatability and stability of the proposed method were also studied. Compared with ultrasonic-assisted extraction(UAE) and hydrodistillation(HD) extraction, the proposed method is more efficient, faster and easier to be operated at room temperature with smaller sample and energy consumption. It is suggested that the ultrasonic nebulization extraction can be used as a novel alternative method for the extraction of volatile components from traditional Chinese patent medicine.展开更多
In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in det...In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.展开更多
A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into...A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into a dense cloud of droplets using an ultrasonic nebulizer. The resulting droplets are then subjected to analysis by laser induced breakdown spectroscopy (LIBS). A purpose-built ultrasonic nebulizer assisted LIBS (UN-LIBS) system has been applied to the analysis of aqueous samples at trace levels of concentration. Experimental investigations of solution samples were carried out with various dissolved trace metal elements (Mn, Zn, Cu, Pb, Fe, Mg and Na) using this approach. The characteristics of UN-LIBS signal of the elements were investigated regarding the lifetime and S/B ratio and the calibration curves for trace metal elements analyses. The obtained LODs are comparable or much better than the LODS of the reported signal enhancement approaches when the laser pulse energy was as low as 30 mJ. The good linearity of calibration curves and the low LODs shows the potential ability of this method for metal elements analysis application. The density of the electrons was calculated by measuring the Stark width of the line of Ha. The possible mechanism of the LIBS signal enhancement of this approach was briefly discussed.展开更多
A new automatic sample solution introduction system for miniature simultaneous microwave plasma torch(MPT) atomic emission spectrometer was developed. The operating parameters were optimized. The detection limits of...A new automatic sample solution introduction system for miniature simultaneous microwave plasma torch(MPT) atomic emission spectrometer was developed. The operating parameters were optimized. The detection limits of the spectrometer with an ultrasonic nebulizer for Ag, Al, Ba, Ca, Cr, Cu, Fe, Mg, Mn, Sr, and V are 5-10 times lower than those obtained with a pneumatic nebulizer and are also lower than those obtained by a Model JX-lOlO MPT spectrometer. Two practical samples were analyzed to test the reliability and sensitivity of the system.展开更多
In this study, an ultrasonic nebulizer unit was established to improve the quantitative analysis ability of laser-induced breakdown spectroscopy (LIBS) for liquid samples detection, using solutions of the heavy meta...In this study, an ultrasonic nebulizer unit was established to improve the quantitative analysis ability of laser-induced breakdown spectroscopy (LIBS) for liquid samples detection, using solutions of the heavy metal element Pb as an example. An analytical procedure was designed to guarantee the stability and repeatability of the LIBS signal. A series of experiments were carried out strictly according to the procedure. The experimental parameters were optimized based on studies of the pulse energy influence and temporal evolution of the emission features. The plasma temperature and electron density were calculated to confirm the LTE state of the plasma. Normalizing the intensities by background was demonstrated to be an appropriate method in this work. The linear range of this system for Pb analysis was confirmed over a concentration range of 0-4,150ppm by measuring 12 samples with different concentrations. The correlation coefficient of the fitted calibration curve was as high as 99.94% in the linear range, and the LOD of Pb was confirmed as 2.93ppm. Concentration prediction experiments were performed on a further six samples. The excellent quantitative ability of the system was demonstrated by comparison of the real and predicted concentrations of the samples. The lowest relative error was 0.043% and the highest was no more than 7.1%.展开更多
基金Supported by the Basic Research Foundation from Jilin University China(No.200903131)
文摘The ultrasonic nebulization extraction(UNE) was developed and applied to the extraction of volatile components from traditional Chinese patent medicine Xiaoyao Pills. Several parameters of ultrasonic nebulization extraction including the sample particle size, solvent volume, extraction time and ultrasonic power were studied and selected. As a result, 2.4 g of sample with particle size of 80 mesh was extracted with 15 mL of n-hexane for 20 min at an ultrasonic power of 35 W. The volatile components were analyzed by gas chromatography-mass spectrometry (GC-MS) under the optimal conditions and 57 compounds were identified. The precision, repeatability and stability of the proposed method were also studied. Compared with ultrasonic-assisted extraction(UAE) and hydrodistillation(HD) extraction, the proposed method is more efficient, faster and easier to be operated at room temperature with smaller sample and energy consumption. It is suggested that the ultrasonic nebulization extraction can be used as a novel alternative method for the extraction of volatile components from traditional Chinese patent medicine.
文摘In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.
基金supported by National Natural Science Foundation of China(No.11104153)
文摘A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into a dense cloud of droplets using an ultrasonic nebulizer. The resulting droplets are then subjected to analysis by laser induced breakdown spectroscopy (LIBS). A purpose-built ultrasonic nebulizer assisted LIBS (UN-LIBS) system has been applied to the analysis of aqueous samples at trace levels of concentration. Experimental investigations of solution samples were carried out with various dissolved trace metal elements (Mn, Zn, Cu, Pb, Fe, Mg and Na) using this approach. The characteristics of UN-LIBS signal of the elements were investigated regarding the lifetime and S/B ratio and the calibration curves for trace metal elements analyses. The obtained LODs are comparable or much better than the LODS of the reported signal enhancement approaches when the laser pulse energy was as low as 30 mJ. The good linearity of calibration curves and the low LODs shows the potential ability of this method for metal elements analysis application. The density of the electrons was calculated by measuring the Stark width of the line of Ha. The possible mechanism of the LIBS signal enhancement of this approach was briefly discussed.
文摘A new automatic sample solution introduction system for miniature simultaneous microwave plasma torch(MPT) atomic emission spectrometer was developed. The operating parameters were optimized. The detection limits of the spectrometer with an ultrasonic nebulizer for Ag, Al, Ba, Ca, Cr, Cu, Fe, Mg, Mn, Sr, and V are 5-10 times lower than those obtained with a pneumatic nebulizer and are also lower than those obtained by a Model JX-lOlO MPT spectrometer. Two practical samples were analyzed to test the reliability and sensitivity of the system.
基金Financial support from the National Natural Science Foundation of China (Grant No. 11104153) is highly acknowledged.
文摘In this study, an ultrasonic nebulizer unit was established to improve the quantitative analysis ability of laser-induced breakdown spectroscopy (LIBS) for liquid samples detection, using solutions of the heavy metal element Pb as an example. An analytical procedure was designed to guarantee the stability and repeatability of the LIBS signal. A series of experiments were carried out strictly according to the procedure. The experimental parameters were optimized based on studies of the pulse energy influence and temporal evolution of the emission features. The plasma temperature and electron density were calculated to confirm the LTE state of the plasma. Normalizing the intensities by background was demonstrated to be an appropriate method in this work. The linear range of this system for Pb analysis was confirmed over a concentration range of 0-4,150ppm by measuring 12 samples with different concentrations. The correlation coefficient of the fitted calibration curve was as high as 99.94% in the linear range, and the LOD of Pb was confirmed as 2.93ppm. Concentration prediction experiments were performed on a further six samples. The excellent quantitative ability of the system was demonstrated by comparison of the real and predicted concentrations of the samples. The lowest relative error was 0.043% and the highest was no more than 7.1%.