期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Ultrasound elastography for evaluating stiffness of the human lens nucleus with aging:a feasibility study
1
作者 Hai-Yan Zhou Hong Yan +1 位作者 Wei-Jia Yan Xin-Chuan Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第2期240-244,共5页
AIM:To investigate the significance of ultrasound elastography for evaluating stiffness of the human lens nucleus in volunteers with different ages.METHODS:A total of 90 volunteers(lens transparency,uncorrected visual... AIM:To investigate the significance of ultrasound elastography for evaluating stiffness of the human lens nucleus in volunteers with different ages.METHODS:A total of 90 volunteers(lens transparency,uncorrected visual acuity≥0.5,intraocular pressure:14-19 mm Hg)were divided into 3 groups according to age:Group A(30 people,median age:82±3.5 y,mean axial lengths 23.7±0.5 mm);Group B(30 people,median age:46±2.1 y,mean axial lengths 23.9±0.4 mm);and Group C(30 people,median age:22±3.5 y,mean axial lengths 24.0±0.4 mm).Lens nuclear stiffness was measured by Free-hand qualitative elastography by independent operators.Strain gray scale and color-coded elastography maps were recorded.In each case,three consecutive detections were performed and strain ratio was used for statistical analysis.RESULTS:Elastography analysis showed excellent diagnostic performance for lens sclerosis.Lens strain ratio was lowest(0.03±0.01)%in Group A and highest(2.03±0.43)%in Group C.Lens strain ratio was moderate(0.64±0.10)%in Group B.There were significant differences between these three groups(P<0.05).The lens nucleus strain rate changes with age.With aging,the lens nucleus strain rate and resilience decrease,demonstrating harder texture.CONCLUSION:The relationship between human lens stiffness and age is demonstrated by ultrasound elastography.Older age is associated with lower strain ratio and less resilience of the lens. 展开更多
关键词 ultrasound elastography human lens nucleus STIFFNESS
原文传递
Experimental model standardizing polyvinyl alcohol hydrogel to simulate endoscopic ultrasound and endoscopic ultrasoundelastography
2
作者 Elymir S Galvis-García Sergio Sobrino-Cossío +4 位作者 Arturo Reding-Bernal Yesica Contreras-Marín Karina Solórzano-Acevedo Patricia González-Zavala Rosa M Quispe-Siccha 《World Journal of Gastroenterology》 SCIE CAS 2020年第34期5169-5180,共12页
BACKGROUND Endoscopic ultrasound(EUS)and endoscopic ultrasound elastography(EUS-E)simulation lessens the learning curve;however,models lack realism,diminishing competitiveness.AIM To standardize the mechanical propert... BACKGROUND Endoscopic ultrasound(EUS)and endoscopic ultrasound elastography(EUS-E)simulation lessens the learning curve;however,models lack realism,diminishing competitiveness.AIM To standardize the mechanical properties of polyvinyl alcohol(PVA)hydrogel for simulating organs and digestive lesions.METHODS PVA hydrogel(Sigma Aldrich,degree of hydrolysis 99%)for simulating EUS/EUS-E lesions was investigated in Unidad de Investigación y Desarrollo Tecnológico at Hospital General de México“Dr.Eduardo Liceaga”,Mexico City.We evaluated physical,contrast,elasticity and deformation coefficient characteristics in lesions,applying Kappa’s concordance and satisfaction questionnaire(Likert 4-points).RESULTS PVA hydrogel showed stable mechanical properties.Density depended on molecular weight(MW)and concentration(C).PVA bblocks with the greatest density showed lowest tensile strength(r=-0.8,P=0.01).Lesions were EUSgraphically visible.Homogeneous and heterogeneous examples were created from PVA blocks or PVA phantoms,exceeding(MW2=146000-186000,C9=15%and C10=20%)with a density under(MW1=85000-124000,C1=7%and C2=9%).We calculated elasticity and deformation parameters of solid(blue)areas,contrasting with the norm(Kappa=0.8;high degree of satisfaction).CONCLUSION PVA hydrogels were appropriate for simulating organs and digestive lesions using EUS/EUS-E,facilitating practice and reducing risk.Repetition amplified skills,while reducing the learning curve. 展开更多
关键词 Endoscopic ultrasound simulators in endoscopy Polyvinyl alcohol Endoscopic ultrasound Endoscopic ultrasound elastography STRAIN ELASTICITY
下载PDF
The value of ultrasound elastography in differential diagnosisof superficial lymph nodes
3
作者 Yanrong ZHANG Qing LV +7 位作者 Yehua YIN Mingxing XIE Feixiang XIANG Chengfa LU Tianwei YAN Wei LI Hui XU Yan HUANG 《Frontiers of Medicine》 SCIE CSCD 2009年第3期368-374,共7页
The study evaluated the value of ultrasound elastography in differentiating the benign and malignant superficial lymph nodes.A total of 112 subjects,including 82 patients with enlarged lymph nodes and 30 healthy volunt... The study evaluated the value of ultrasound elastography in differentiating the benign and malignant superficial lymph nodes.A total of 112 subjects,including 82 patients with enlarged lymph nodes and 30 healthy volunteers,were recruited.All the subjects were examined by B-mode ultrasonography,power Doppler ultrasonogra-phy and elastography.Most of the patients were histo-pathologically confirmed by needle aspiration cytology and some patients were diagnosed by clinical data combined with follow-upfindings.The sensitivity,speci-ficity and accuracy of B-mode ultrasonography were 59.8%,76.5%and 67.1%,those of the bloodflow classification by power Doppler ultrasonography 77.0%,82.3%and 79.4%and those of elastographic classification 74.7%,97.1%and 84.5%,respectively.The elasticity of the lymph nodes was quantitatively measured and defined as stiffness value.When the stiffness value of 2.395 was taken as the cutoff point,the sensitivity and specificity of elastography were 78.41%and 98.51%,and the Youden index reached the highest,with the value being 0.7692.The stiffness values of two indeterminate benign lymph nodes,the elastrographicfindings of which were rated as patterns 2 and 3,were below the cutoff point.The elastographicfindings of 10 malignant lymph nodes were also classified as pattern 2 or 3.Only one of them had the stiffness values below the cutoff point.It was concluded that ultrasound elastography is a novel,noninvasive and convenient tool for the differentiation of the nature of the superficial lymph nodes in clinical practice. 展开更多
关键词 ultrasound elastography lymph node power Doppler sonography
原文传递
Enhanced endoscopic ultrasound imaging for pancreatic lesions: The road to artificial intelligence 被引量:1
4
作者 Marco Spadaccini Glenn Koleth +10 位作者 James Emmanuel Kareem Khalaf Antonio Facciorusso Fabio Grizzi Cesare Hassan Matteo Colombo Benedetto Mangiavillano Alessandro Fugazza Andrea Anderloni Silvia Carrara Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2022年第29期3814-3824,共11页
Early detection of pancreatic cancer has long eluded clinicians because of its insidious nature and onset.Often metastatic or locally invasive when symptomatic,most patients are deemed inoperable.In those who are symp... Early detection of pancreatic cancer has long eluded clinicians because of its insidious nature and onset.Often metastatic or locally invasive when symptomatic,most patients are deemed inoperable.In those who are symptomatic,multi-modal imaging modalities evaluate and confirm pancreatic ductal adenocarcinoma.In asymptomatic patients,detected pancreatic lesions can be either solid or cystic.The clinical implications of identifying small asymptomatic solid pancreatic lesions(SPLs)of<2 cm are tantamount to a better outcome.The accurate detection of SPLs undoubtedly promotes higher life expectancy when resected early,driving the development of existing imaging tools while promoting more comprehensive screening programs.An imaging tool that has matured in its reiterations and received many image-enhancing adjuncts is endoscopic ultrasound(EUS).It carries significant importance when risk stratifying cystic lesions and has substantial diagnostic value when combined with fine needle aspiration/biopsy(FNA/FNB).Adjuncts to EUS imaging include contrast-enhanced harmonic EUS and EUS-elastography,both having improved the specificity of FNA and FNB.This review intends to compile all existing enhancement modalities and explore ongoing research around the most promising of all adjuncts in the field of EUS imaging,artificial intelligence. 展开更多
关键词 Pancreatic ductal adenocarcinoma Pancreatic cancer Endoscopic ultrasound Contrast-enhanced endoscopic ultrasound Endoscopic ultrasound contrast agents Endoscopic ultrasound elastography Artificial intelligence Fractal analysis ENDOSCOPY IMAGING
下载PDF
Assessment of diaphragmatic function by ultrasonography:Current approach and perspectives 被引量:4
5
作者 Alain Boussuges Sarah Rives +1 位作者 Julie Finance Fabienne Brégeon 《World Journal of Clinical Cases》 SCIE 2020年第12期2408-2424,共17页
This article reports the various methods used to assess diaphragmatic function by ultrasonography.The excursions of the two hemidiaphragms can be measured using two-dimensional or M-mode ultrasonography,during respira... This article reports the various methods used to assess diaphragmatic function by ultrasonography.The excursions of the two hemidiaphragms can be measured using two-dimensional or M-mode ultrasonography,during respiratory maneuvers such as quiet breathing,voluntary sniffing and deep inspiration.On the zone of apposition to the rib cage for both hemidiaphragms,it is possible to measure the thickness on expiration and during deep breathing to assess the percentage of thickening during inspiration.These two approaches make it possible to assess the quality of the diaphragmatic function and the diagnosis of diaphragmatic paralysis or dysfunction.These methods are particularly useful in circumstances where there is a high risk of phrenic nerve injury or in diseases affecting the contractility or the motion of the diaphragm such as neuro-muscular diseases.Recent methods such as speckle tracking imaging and ultrasound shear wave elastography should provide more detailed information for better assessment of diaphragmatic function. 展开更多
关键词 ultrasound Hemidiaphragm Motion Thickness PARALYSIS Dysfunction Two-dimensional mode M-MODE Speckle tracking imaging ultrasound shear wave elastography
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部