期刊文献+
共找到1,152篇文章
< 1 2 58 >
每页显示 20 50 100
Shielding AZ91D-1%Ca from corrosion through ultrasound melt treatment:A study for stent design
1
作者 I.V.Gomes M.Pacheco +6 位作者 M.Nienaber S.C.Neves D.Mei A.Barros R.L.Reis J.L.Alves H.Puga 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第8期2901-2915,共15页
Magnesium-based materials show great potential for producing biodegradable stents,but their high corrosion rates are a roadblock.This study investigates whether ultrasound melt treatment can change the corrosion respo... Magnesium-based materials show great potential for producing biodegradable stents,but their high corrosion rates are a roadblock.This study investigates whether ultrasound melt treatment can change the corrosion response of an extruded AZ91D-1.0%Ca(wt.%)in Earle's Balanced Salt Solution by tailoring the intermetallics'morphology in the as-extruded state.The results showed that the wires from ultrasound-treated ingots corroded faster than non-treated ones in immersion for up to 6 hours.This trend shifted for longer periods,and ultrasound-treated material showed lower corrosion rates and uniform corrosion,while the non-treated material displayed localized corrosion signs.Tensile testing of the wires demonstrated that immersion in EBSS lowered the tensile strength and elongation at fracture due to material degradation,regardless of the processing route.Nonetheless,this decline was sharper in the non-treated material.These findings suggest that ultrasound melt processing can be a promising method for improving the corrosion resistance of magnesium-based materials,paving the way for their use in manufacturing biodegradable stents. 展开更多
关键词 MAGNESIUM ultrasound treatment STENT CORROSION Mechanical properties
下载PDF
Enhancement of intranasalmucosal immunization of mucosal vaccines by ultrasonic treatment
2
作者 Haowei Xu Yang Liao +3 位作者 Mankovskaya Svetlana Deguang Yang Huaibin Wan Zonghua Liu 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第4期405-422,共18页
The pathogens of most infectious diseases invade the host through mucosal sites,and immunization with mucosal vaccines is the best means of combating these infectious diseases.Oral delivery and nasal delivery are the ... The pathogens of most infectious diseases invade the host through mucosal sites,and immunization with mucosal vaccines is the best means of combating these infectious diseases.Oral delivery and nasal delivery are the most common methods of mucosal vaccination.However,the delivery process is inefficient,and mucosal vaccination is ineffective because the vaccine formulation is easily and rapidly removed and has difficulty in crossing the mucosal surface.In this paper,we investigated whether the mucosal immune response could be enhanced by ultrasound facilitation of nasal mucosal delivery of vaccine preparations.For this purpose,we used manganese dioxide(MnO2)as the vaccine carrier/adjuvant,coated with chitosan oligosaccharide(COS)to enhance mucosal adsorption,and further physically adsorbed model antigen ovalbumin(OVA)to construct a nanoparticulate vaccine formulation MnO2@COS@OVA.Ultrasound treatment was found to promote antigen delivery and recruitment of dendritic cells(DCs)and macrophages as well as T-cell infiltration in nasal mucosal tissues through nasal mucosal immunization studies.With ultrasound assistance,MnO2@COS@OVA particles promoted the maturation of DCs in vitro and in vivo and promoted the production of effector memory T cells in vivo and cytokine secretion by splenocytes in vitro.In particular,ultrasound treatment significantly increased the levels of secretory IgA antibodies in the nasal mucosa and genital tract mucosa of experimental mice.In addition,the experimental data showed that the MnO2@COS@OVA particles had good biocompatibility and caused no significant damage to the nasal mucosal and vital organ tissue.These data suggest that ultrasound treatment can promote the induction of efficient immune responses to mucosal vaccines and provide new ideas for the opening and clinical translation of mucosal vaccines. 展开更多
关键词 Mucosal vaccine ultrasound treatment MNO2 Nasal delivery
下载PDF
Preparation of the Supported Heteropolyacids Catalyst by Ultrasound-plasma Treatment 被引量:3
3
作者 LI Yang CHU Wei +1 位作者 CHEN Muhua HU Jinyan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第2期234-238,共5页
Novel catalysts of phosphotungstic heteropolyacids(PW_(12))supported on neutral alumina were prepared by assistance of ultrasound and plasma treatment.The prepared catalysts were characterized by FT-IR pyridine adsorp... Novel catalysts of phosphotungstic heteropolyacids(PW_(12))supported on neutral alumina were prepared by assistance of ultrasound and plasma treatment.The prepared catalysts were characterized by FT-IR pyridine adsorption(Py-IR),temperature programmed desorption of Pyridine(Py-TPD),BET and X-ray diffraction(XRD),and their catalytic performances were evaluated by the cationic polymerization of tetrahydrofuran.The results indicate that plasma treatment remarkably increases the surface acidity of the prepared catalyst while ultrasonic treatment induces PW_(12)to uniformly disperse on the support surface and expose more active sites for the acid catalytic reaction.A higher catalytic activity(69.7%)is obtained on the novel catalyst,which significantly outstripped that on the conventional sample(57.5%). 展开更多
关键词 杂多酸催化剂 超声波-等离子体治疗 胃酸过多 制备方法
下载PDF
Comparison of ultrasound-guided thrombin injection and compression repair in treatment of iatrogenic femoral arterial pseudoaneurysms 被引量:3
4
作者 覃军 黄岚 +7 位作者 李爱民 宋耀明 晋军 于学军 周小波 林春梅 高云华 卓忠雄 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第4期261-267,共7页
Objective:To retrospectively compare the efficacy and safety of ultrasound-guided thrombin injection (UGTI) with ultrasound-guided compression repair (UGCR) in patients with postcatheter-izational femoral arterial pse... Objective:To retrospectively compare the efficacy and safety of ultrasound-guided thrombin injection (UGTI) with ultrasound-guided compression repair (UGCR) in patients with postcatheter-izational femoral arterial pseudoaneurysms (PSA). Methods: Thirty patients of this iatrogenic PSA [8 males, 22 females, average age (66. 5±5. 2) years] in our institution from 1997 to 2004 were retrospectively analyzed. Among them, 11 patients were treated with UGCR, 2 under continuous ultrasonographic (US) guidance and 9 under the guidance of femoral arterial bruit auscultation and dorsalis pedis artery palpation. Because UGCR was failed in 5 patients, consecutively 24 patients were treated with UGTI. Swine thrombin solution at a concentration of 200 U/ml was injected percutaneously using 22-25 gauge needles under color Doppler US. Demographics, clinical variables, pseudoaneurysm characteristics, and results of the 2 groups were compared by using Fisher's exact test and Student's t test. Results: The initial success rate of UGCR was 36. 4% (4/11) and the overall success rate was 45. 5% (5/11). Ten of 11 patients suffered from local pain during the compression, but there was no any complication in UGTI group. The average dose of injected thrombin was (180 + 82) U for PSA of a single loculus and (315±150) U for multiloculated PSA. The initial success rate of UGTI was 89.5% (17/19) and the overall success rate was 100% (24/24). Conclusion;UGTI offers a safe, quick and effective means of definitively treating femoral pseudoaneurysms and seems superior to UGCR. The amount of thrombin applied on our people seems smaller compared with others' work. 展开更多
关键词 超声检查 凝血酶 股骨动脉瘤 医源性疾病
下载PDF
Usefulness of contrast enhanced ultrasound in monitoring therapeutic response after hepatocellular carcinoma treatment 被引量:3
5
作者 Davide Roccarina Matteo Garcovich +4 位作者 Maria Elena Ainora Laura Riccardi Maurizio Pompili Antonio Gasbarrini Maria Assunta Zocco 《World Journal of Hepatology》 CAS 2015年第14期1866-1874,共9页
In the last years, the development in the oncology field has been huge and rapid. In particular, the evaluation of response to anti-tumour treatments has been being object of intense research, producing significant ch... In the last years, the development in the oncology field has been huge and rapid. In particular, the evaluation of response to anti-tumour treatments has been being object of intense research, producing significant changes. Response assessment after therapy in solid neoplasias has always used radiological imaging techniques, with tumour size reduction representing a presumed therapeutic efficacy. However, with the introduction of anti-angiogenetic drugs the evaluation of tumour size has become unsuitable because some tumours, under treatment, show only tumour perfusion changes rather than lesion shrinkage. Between different imaging techniques with contrast-enhancement, contrastenhanced ultrasound(CEUS) and, in particular, dynamic CEUS have arisen as a promising and non-invasive device for monitoring cancer treatments. Moreover, the introduction of perfusion software has even more refined the technique since it is able to provide quantitative parameters related to blood flow and blood volume that can be associated with tumour response and clinical outcome such as the progression free survival and the overall survival. Here, we give an overview of the current status of CEUS in monitoring hepatocellular carcinoma response to different kind of treatments. 展开更多
关键词 Dynamic CONTRAST-ENHANCED ultrasound HEPATOCELLULAR carcinoma ABLATIVE treatment Antiangiogeneticdrugs Time-intensitive CURVE
下载PDF
The Value of Transvaginal Ultrasound in Clinical Surgical Treatment of Cesarean Scar Pregnancy 被引量:2
6
作者 曾祯 丁淑萍 +7 位作者 曾雪 曹穗 魏伶羽 刘燕燕 杨福艳 龚静吉 陈汉平 徐晓燕 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第4期536-540,共5页
The clinical value of transvaginal ultrasound in clinical surgical treatment of cesarean scar pregnancy(CSP) was evaluated. The clinical data of 104 patients with CSP admitted at Tongji Hospital from 2013 to 2016 were... The clinical value of transvaginal ultrasound in clinical surgical treatment of cesarean scar pregnancy(CSP) was evaluated. The clinical data of 104 patients with CSP admitted at Tongji Hospital from 2013 to 2016 were collected and analyzed retrospectively, including the patients' age, gestational age, the size of gestational sac or uneven mass, the uterine scar thickness, β human chorionic gonadotropin(h CG) levels and so on. Of these 104 cases, 30 cases were subjected to laparotomy, 29 cases to laparoscopy, 27 cases to hysteroscopy, 16 cases to ultrasound-guided uterine curettage, and 2 cases to conservative treatment. The transvaginal ultrasound showed that uterine scar thickness and gestational sac or uneven mass size had significant difference(P<0.05) among different surgical methods by comparatively analyzing the patients' data. It was suggested that transvaginal ultrasound may provide the valuable reference for choosing clinical surgical procedures for CSP. 展开更多
关键词 临床应用 剖宫产 超声 阴道 价值 瘢痕 妊娠 人绒毛膜促性腺激素
下载PDF
High Intensity Focused Ultrasound Optimal Device Design for Targeted Prostate Cancer Treatment: A Numerical Study 被引量:2
7
作者 Laura Curiel Dexter Hobson +1 位作者 Jean-Yves Chapelon Samuel Pichardo 《Journal of Modern Physics》 2013年第2期240-245,共6页
A parametric study was performed to design a device capable of treating small targeted regions within the prostate using high intensity focused ultrasound, while sparing the surrounding organs and minimizing the numbe... A parametric study was performed to design a device capable of treating small targeted regions within the prostate using high intensity focused ultrasound, while sparing the surrounding organs and minimizing the number of elements. The optimal focal length (L), operating frequency (f), element size (a) and central opening radius for lodging an imaging probe (r) of a device that would safely treat tissue within the prostate were obtained. Images from the Visible Human Project were used to determine simulated organ sizes and treatment locations. Elliptical tumors were placed throughout the simulated prostate and their lateral and axial limits were selected as test locations. Using graphics processors, the acoustic field and Bio-Heat Transfer Equation were solved to calculate the heating produced during a simulated treatment. L, f, a and r were varied from 45 to 75 mm, 2.25 to 3 MHz, 1.5 to 8 times the wavelength and 9 to 12.5 mm, respectively. The resulting optimal device was a 761-element concentric-ring transducer with L = 68 mm, f = 2.75 MHz, a = 2.05λ and r = 9 mm. Simulated thermal lesions showed that it was possible to treat target tumors consistent with reported locations and sizes for prostate cancer. 展开更多
关键词 FOCUSED ultrasound PROSTATE Cancer Thermal Ablation NON-INVASIVE treatment BHTE HIFU
下载PDF
Evaluation of the Therapeutic Effect of Contrast-Enhanced Ultrasound on Different Types of Knee Osteoarthritis in the Elderly
8
作者 Na Wen Yingcong Xiao 《Journal of Biosciences and Medicines》 CAS 2023年第5期1-8,共8页
Objective: To evaluate the curative effect of the Traditional Chinese Medicine (TCM) external therapy on knee osteoarthritis patients with different TCM constitutions using musculoskeletal ultrasonography and contrast... Objective: To evaluate the curative effect of the Traditional Chinese Medicine (TCM) external therapy on knee osteoarthritis patients with different TCM constitutions using musculoskeletal ultrasonography and contrast-enhanced ultrasonography, and to explore the application value of contrast-enhanced ultrasonography in knee joint diseases. Methods: A total of 57 patients diagnosed with knee osteoarthritis in Shaanxi University of Traditional Chinese Medicine from December 2019 to May 2021 were collected, and they were divided into qi stagnation and blood stasis type group (23 cases) and cold-dampness obstruction type group (34 cases) according to the traditional Chinese medicine method. All patients were given acupuncture combined with TCM fumigation and washing. All patients underwent musculoskeletal ultrasonography and contrast-enhanced ultrasonography before and after treatment, observed and recorded relevant data, and compared the treatment effects between the two groups. Results: 85.96% (49/57) of knee osteoarthritis (KOA) patients had suprapatellar bursa effusion, 42.1% (24/57) had iliotibial band bursae effusion, some of which had poor sound transmission, and thickened synovium was seen in most effusions, 33.33% (19/57) had osteophyte formation. Compared with before treatment, the depth of suprapatellar sac effusion in the Qi stagnation and blood stasis type group decreased after treatment (P Conclusion: Musculoskeletal contrast-enhanced ultrasonography was used to quantitatively evaluate the efficacy of TCM external therapy on KOA for different TCM constitutions. Dynamic observation of synovial lesions of knee osteoarthritis provides a valuable imaging method for evaluating the efficacy of traditional Chinese medicine. 展开更多
关键词 Contrast-Enhanced ultrasound External treatment of Traditional Chinese Medicine Knee Osteoarthritis Qi Stagnation and Blood Stasis Type Cold-Dampness Obstruction Type
下载PDF
Lax Facial Skin Treated with High-Intensity Focused Ultrasound Devices: Efficacy and Safety Evaluations
9
作者 Meng Wu Huan Chen 《Journal of Cosmetics, Dermatological Sciences and Applications》 2023年第3期1455-1472,共9页
Background: High-intensity focused ultrasound (HIFU) has been introduced to improve skin laxity in recent years. However, very few studies have evaluated the safety and effectiveness of HIFU in Chinese populations. Me... Background: High-intensity focused ultrasound (HIFU) has been introduced to improve skin laxity in recent years. However, very few studies have evaluated the safety and effectiveness of HIFU in Chinese populations. Methods: In the study, 30 Chinese participants underwent HIFU (Bolida, Inc., Changsha, China) rejuvenation between February 1, 2022, and September 30, 2022. There were three different focal depths used depending on the area where shots were captured (4.5 mm, 4 MHz;3 mm, 7 MHz;1.5 mm, 7 MHz). After 3 months and 6 months of treatment, efficacy and safety were assessed by quantitative analysis. Results: Patients were satisfied with the clinical effects of HIFU rejuvenation after one session. In terms of effectiveness, HIFU was most successful in areas around the jawline, cheek, and perioral. In four cases, erythema was observed, in two cases, swollen gums were seen, but all of these effects were transient and mild. Conclusion: Bolida system can be safe and effective for facial tightening, additionally, they are most effective for jawline, cheek, and perioral improvements. In clinical practice, the Bolida system can be recommended as a reliable treatment option. . 展开更多
关键词 High-Intensity Focused ultrasound Bolida System treatment EFFICACY SAFETY
下载PDF
超声处理对杜仲籽仁蛋白结构及理化特性的影响
10
作者 王艳珍 张圆圆 纵伟 《中国油脂》 CAS CSCD 北大核心 2024年第5期66-70,共5页
旨在为杜仲籽仁蛋白的开发与应用提供参考,以杜仲籽仁粕为原料,采用碱溶酸沉法提取蛋白,采用500 W、35 kHz超声波对杜仲籽仁蛋白处理不同的时间(0、10、20、30 min和40 min),探究超声处理对杜仲籽仁蛋白微观结构、理化特性(粒径、Zeta-... 旨在为杜仲籽仁蛋白的开发与应用提供参考,以杜仲籽仁粕为原料,采用碱溶酸沉法提取蛋白,采用500 W、35 kHz超声波对杜仲籽仁蛋白处理不同的时间(0、10、20、30 min和40 min),探究超声处理对杜仲籽仁蛋白微观结构、理化特性(粒径、Zeta-电位、内源荧光光谱、溶解性、持水性、持油性、起泡性、起泡稳定性、乳化性、乳化稳定性)的影响。结果表明:超声处理可改变杜仲籽仁蛋白的微观结构、粒径、Zeta-电位和荧光强度;超声处理20 min时,杜仲籽仁蛋白溶解度达到75.35%;超声处理10 min时,杜仲籽仁蛋白乳化性最大,达到72.12 m^(2)/g;超声处理40 min时,杜仲籽仁蛋白持水性、持油性、起泡性和起泡稳定性最大,分别达到4.32 g/g、3.46 g/g、23.12%和21.12%。综上,超声处理可改善杜仲籽仁蛋白的持水性、持油性、起泡性、乳化性等功能特性。 展开更多
关键词 杜仲籽仁蛋白 超声处理 微观结构 理化特性
下载PDF
超声辅助浸渍处理对冻干柠檬片品质的影响
11
作者 胡云峰 马畅 +2 位作者 白亚辉 陈君然 路敏 《粮食与油脂》 北大核心 2024年第4期74-79,共6页
采用超声辅助浸渍处理对柠檬片进行预处理,探究不同质量分数护色剂及超声辅助浸渍处理对冻干柠檬片色泽、营养物质与风味品质的影响。结果表明:最佳护色剂配方为普鲁兰多糖质量分数0.9%、乙二胺四乙酸二钠质量分数0.2%、CaCl_(2)质量分... 采用超声辅助浸渍处理对柠檬片进行预处理,探究不同质量分数护色剂及超声辅助浸渍处理对冻干柠檬片色泽、营养物质与风味品质的影响。结果表明:最佳护色剂配方为普鲁兰多糖质量分数0.9%、乙二胺四乙酸二钠质量分数0.2%、CaCl_(2)质量分数0.1%、柠檬酸质量分数1.0%,最佳超声处理时间为10 min。与未超声处理组相比,超声处理10 min的冻干柠檬片亮度、复水比、维生素C含量、抗氧化成分及抗氧化能力总体提高。 展开更多
关键词 冻干柠檬片 超声辅助处理 品质
下载PDF
以肺部超声为应用的多学科诊疗体系在高原性肺水肿诊疗中的价值
12
作者 袁灵 钟静怡 +4 位作者 江兵 熊明 虞莲会 康厚乐 钟武 《成都医学院学报》 CAS 2024年第1期94-97,104,共5页
目的探索以肺部超声为应用的多学科诊疗体系在高原性肺水肿诊疗中的价值。方法选取2018—2022年在甘孜州稻城县人民医院急诊科收治的200例疑似高原性肺水肿患者为研究对象,将其中确诊的115例患者按照平衡序贯法随机分为试验组(采用以肺... 目的探索以肺部超声为应用的多学科诊疗体系在高原性肺水肿诊疗中的价值。方法选取2018—2022年在甘孜州稻城县人民医院急诊科收治的200例疑似高原性肺水肿患者为研究对象,将其中确诊的115例患者按照平衡序贯法随机分为试验组(采用以肺部超声为应用的多学科诊疗体系,n=56)和对照组(采用常规诊疗方式,n=59),比较两组的诊疗效果。结果在早期诊断高原性肺水肿中,肺部超声的灵敏度、正确指数及阴性预测值均高于X线检查结果(P<0.05),而与CT检查结果比较差异无统计学意义(P>0.05)。试验组的诊疗时效性、抗生素使用率、心衰发生率、无创呼吸机上机率、康复期恢复等方面优于对照组(P<0.05)。结论以肺部超声为应用的多学科诊疗体系在高原性肺水肿早期诊断中具有较高的灵敏度、正确指数及阴性预测值,可促进患者愈后及康复。 展开更多
关键词 高原性肺水肿 肺部超声 诊疗体系
下载PDF
肌骨超声定位引导下冲击波治疗继发性手部肌腱粘连效果观察
13
作者 张启富 周开斌 +2 位作者 龙耀斌 陈在娟 陈耀智 《广东医学》 CAS 2024年第3期318-323,共6页
目的研究肌骨超声定位引导下冲击波治疗手掌腕部和前臂外伤术后继发手部肌腱粘连的效果。方法手掌腕部和前臂外伤术后继发手部肌腱粘连患者80例,按随机数字表法分为治疗组和对照组,每组40例,两组患者均给予手掌腕部和前臂肌腱康复治疗,... 目的研究肌骨超声定位引导下冲击波治疗手掌腕部和前臂外伤术后继发手部肌腱粘连的效果。方法手掌腕部和前臂外伤术后继发手部肌腱粘连患者80例,按随机数字表法分为治疗组和对照组,每组40例,两组患者均给予手掌腕部和前臂肌腱康复治疗,如蜡疗、关节松动术、作业治疗。对照组患者,根据关节活动度受限情况,徒手检查确定手掌腕部和前臂肌腱粘连部位,给予冲击波治疗;治疗组患者,先对手掌腕部和前臂肌骨超声检查,确定肌腱粘连部位,进行标记定位,再根据定位进行冲击波治疗。两组患者均康复治疗4周,治疗前后对两组患者进行肌骨超声评估手部肌腱粘连程度,肌腱总主动活动度(TAM)测定,VAS疼痛视觉模拟评分评定,上肢及手功能DASH问卷评分测定。结果两组患者在治疗前手部肌腱粘连程度、肌腱TAM、疼痛VAS评分、上肢及手功能DASH评分比较差异无统计学意义(P>0.05),具有可比性。治疗4周后两组患者手部肌腱粘连程度明显改善,肌腱TAM增加,疼痛VAS评分降低,上肢及手功能DASH评分升高,但是治疗组患者手部肌腱粘连程度改善更明显,肌腱TAM增加更多,疼痛VAS评分降低更明显,上肢及手功能DASH评分升高更多,两组比较,差异有统计学意义(P<0.01)。结论肌骨超声定位引导下冲击波治疗结合常规康复治疗可以明显改善继发性手部肌腱粘连,恢复手部分功能。 展开更多
关键词 超声引导 冲击波 康复治疗 手肌腱粘连
下载PDF
肺部超声检查在血液透析合并新型冠状病毒感染中的临床研究
14
作者 王开振 许生甜 +1 位作者 唐能源 李琦晖 《检验医学与临床》 CAS 2024年第8期1162-1165,共4页
目的探讨肺部超声检查在血液透析合并新型冠状病毒感染中的诊断及治疗策略,以期为临床同行提供参考依据。方法分析1例成功治愈的维持性血液透析合并重型新型冠状病毒感染患者的诊断、治疗等基本临床资料,采用“新型冠状病毒感染”“血... 目的探讨肺部超声检查在血液透析合并新型冠状病毒感染中的诊断及治疗策略,以期为临床同行提供参考依据。方法分析1例成功治愈的维持性血液透析合并重型新型冠状病毒感染患者的诊断、治疗等基本临床资料,采用“新型冠状病毒感染”“血液透析”“肺部超声检查”作为关键词对中国知网、PubMed数据库2020-2023年发表的文献进行检索。结果维持性血液透析合并新型冠状病毒感染患者经氧气治疗、抗病毒、抗炎、血液净化(利用肺部超声评估肺部B线变化)、抗感染、抗凝等治疗后痊愈出院,白细胞介素-6、淋巴细胞计数、C反应蛋白、降钙素原、红细胞沉降率、D-二聚体水平均正常,咽拭子新型冠状病毒核酸抗原检测阴性,床旁肺部超声检查提示双肺未见明显B线,肺部CT检查提示肺部渗出明显吸收。文献检索结果:共检索到文献35篇,排除16篇,最终保留可用文献19篇。结合病例分析及文献复习,对肺部超声检查在维持性血液透析合并新型冠状病毒感染中的临床诊断及治疗方法进行分析总结。结论床旁肺部超声检查在识别和分层维持性血液透析合并重型新型冠状病毒感染患者方面非常有效,可即时、准确评估患者的容量状态,保证患者透析的充分性。 展开更多
关键词 重型新型冠状病毒感染 维持性血液透析 肺部超声检查 诊断 治疗策略
下载PDF
无痛诊疗技术在超声PICC置管患儿中的应用效果研究
15
作者 黄亚利 王香红 +4 位作者 李洪辛 易琼 丛丹 方原 李若星 《中国现代医生》 2024年第5期87-90,共4页
目的探讨无痛诊疗技术在超声引导下儿童经外周静脉穿刺中心静脉置管术(peripherally inserted central catheter,PICC)中的应用效果。方法选取笔者医院2021年1月至2023年1月拟行PICC的患儿82例,用随机数字表法将其分为对照组、观察组,每... 目的探讨无痛诊疗技术在超声引导下儿童经外周静脉穿刺中心静脉置管术(peripherally inserted central catheter,PICC)中的应用效果。方法选取笔者医院2021年1月至2023年1月拟行PICC的患儿82例,用随机数字表法将其分为对照组、观察组,每组41例;对照组行常规超声引导下PICC置管术,观察组行无痛诊疗技术超声引导下PICC置管术;对比两组置管成功率、置管完成时间,患儿疼痛程度[儿童疼痛行为量表(children’s pain behavior scale,FLACC)],耐受度[Houpt行为量表(Houpt behavior scale,HBS)],依从性[Frankl量表(Frankl scale,FCS)]及家属满意度。结果观察组置管成功率较对照组高,置管时间较对照组短,差异有统计学意义(P<0.05);观察组FLACC评分较对照组低,HBS评分、FCS评分较对照组高,差异有统计学意义(P<0.05);观察组家属总满意度较对照组高,差异有统计学意义(P<0.05)。结论无痛诊疗技术用于超声引导下儿童PICC置管术可提高置管成功率,缩短置管时间,减轻患儿疼痛程度,增强耐受性、依从性,提升家属满意度。 展开更多
关键词 经外周静脉穿刺中心静脉置管术 超声 无痛诊疗技术
下载PDF
超声处理时间对莲藕淀粉理化和结构特性的影响 被引量:1
16
作者 廖雪勤 汪楠 +3 位作者 胡荣 薛冰洁 张甫生 郑炯 《食品科学》 EI CAS CSCD 北大核心 2024年第6期183-191,共9页
以莲藕淀粉(lotus root starch,LS)为对象,探究不同超声时间(0、10、20、30、40、50 min)对LS糊化特性、流变特性以及片层结构、结晶结构、短程有序结构、微观结构等的影响。结果表明,不同超声时间处理后LS分子链溶胀和缠结增加,糊化黏... 以莲藕淀粉(lotus root starch,LS)为对象,探究不同超声时间(0、10、20、30、40、50 min)对LS糊化特性、流变特性以及片层结构、结晶结构、短程有序结构、微观结构等的影响。结果表明,不同超声时间处理后LS分子链溶胀和缠结增加,糊化黏度最大增至(6059±31)mPa·s;淀粉颗粒表面出现裂缝、塌陷及坑洞,利于水分子进入,黏弹性增加。在超声作用下LS的α-1,6-糖苷键被破坏,部分支链断裂,形成淀粉短链,重新排列成有序的结构,短程有序结构增多,R_(1047/1022)值升高了3.20%;较短时间的超声处理(30 min)增强了淀粉分子间的相互作用,双螺旋结构变得有序和紧密,使T_p和ΔH值分别增大了11.09%和89.21%。长时间超声处理(40~50 min)不利于这种有序结构的形成。本研究结果可为超声技术在淀粉理化特性及多尺度结构调控中的应用提供理论参考。 展开更多
关键词 莲藕淀粉 超声处理 黏弹性 糊化特性 短程有序结构
下载PDF
小切口非超声乳化白内障手术治疗硬核白内障的效果分析
17
作者 王强 赵延军 《中外医疗》 2024年第2期58-61,共4页
目的研究硬核白内障患者进行小切口非超声乳化白内障手术的治疗效果以及应用价值。方法随机选择2021年1月—2023年1月临沂市人民医院收治的80例硬核白内障患者为研究对象。采用随机数表法分为研究组与参照组,每组40例。参照组给予常规... 目的研究硬核白内障患者进行小切口非超声乳化白内障手术的治疗效果以及应用价值。方法随机选择2021年1月—2023年1月临沂市人民医院收治的80例硬核白内障患者为研究对象。采用随机数表法分为研究组与参照组,每组40例。参照组给予常规超声乳化白内障手术,研究组给予小切口非超声乳化白内障手术治疗,比较两组硬核白内障患者的眼部指标、临床疗效与并发症发生率。结果研究组眼部指标视力水平(0.46±0.11)优于对照组(0.32±0.10),差异有统计学意义(t=5.956,P<0.05)。研究组硬核白内障患者临床疗效(100.00%)明显高于参照组(70.00%),差异有统计学意义(χ^(2)=14.117,P<0.05)。研究组硬核白内障患者并发症发生率(2.50%)明显低于参照组(15.00%),差异有统计学意义(χ^(2)=3.914,P<0.05)。结论硬核白内障患者采用小切口非超声乳化白内障手术治疗干预能够明显提高硬核白内障患者的临床疗效,恢复眼部指标,降低并发症发生率。 展开更多
关键词 小切口非超声乳化白内障手术治疗 硬核白内障患者 临床疗效
下载PDF
CBL教学法联合MDT翻转课堂在乳腺癌超声教学中的应用
18
作者 王慧 俞飞虹 +1 位作者 黄华兴 马佩 《中国继续医学教育》 2024年第2期64-67,共4页
基于案例教学法(case-based learning,CBL)联合多学科联合会诊(multi-disciplinary treatment,MDT)翻转课堂是“以学生为中心”的全新教学模式,改变了过去“以教师为中心”的传统教学模式。乳腺超声是一门实践性强的学科,这种全新的教... 基于案例教学法(case-based learning,CBL)联合多学科联合会诊(multi-disciplinary treatment,MDT)翻转课堂是“以学生为中心”的全新教学模式,改变了过去“以教师为中心”的传统教学模式。乳腺超声是一门实践性强的学科,这种全新的教学理念和教学模式,让学生进一步了解乳腺癌的诊疗模式,有助于拓展学生思维,提高自主学习能力;加强学生之间的交流合作,培养团队协作能力;培养学生学习兴趣,提高综合分析病例的能力。在今后的教学中,基于CBL教学法联合MDT翻转课堂在乳腺癌的超声教学中将被不断推广应用,进一步推动不同学科之间的融合式教学,为传统课堂教学变革带来新的曙光。 展开更多
关键词 案例教学法 多学科联合会诊 翻转课堂 乳腺癌 超声 教学 传统课堂
下载PDF
超声处理对大黄素-酪蛋白复合物结构及理化性质的影响
19
作者 刘成力 苏小红 +2 位作者 杨敏 季伟 魏玉梅 《食品工业科技》 CAS 北大核心 2024年第6期76-83,共8页
大黄素是一种天然疏水性物质,常通过一定的基质负载以提高其水溶性和生物利用度。本文以酪蛋白胶束为载体,通过超声技术(频率20 kHz,振幅30%)制备了大黄素-酪蛋白复合物微胶囊,采用荧光光谱、红外光谱、扫描电镜技术表征了复合物的结构... 大黄素是一种天然疏水性物质,常通过一定的基质负载以提高其水溶性和生物利用度。本文以酪蛋白胶束为载体,通过超声技术(频率20 kHz,振幅30%)制备了大黄素-酪蛋白复合物微胶囊,采用荧光光谱、红外光谱、扫描电镜技术表征了复合物的结构;分析了复合物的热分解特性和抗氧化特性,并评估了模拟胃肠消化过程中复合物中大黄素的释放特性。结果表明,当大黄素添加量为8~10μg/mg时,1~3 min超声处理对复合物荧光值影响不大。另外,超声处理对复合物的红外光谱及表面形貌影响不大。然而,同一大黄素添加量下,超声1 min时大黄素-酪蛋白复合物的DPPH自由基清除活性最低,但其ABTS+自由基清除活性最高。而且,1 min超声处理改善了复合物中大黄素的释放速率,5 min超声处理后复合物中大黄素的释放率最低。研究结果可为超声处理技术在大黄素-酪蛋白复合物结构及性能调控中的应用提供参考依据。 展开更多
关键词 大黄素 酪蛋白胶束 超声处理 表面形貌 消化性
下载PDF
超声协同蒸汽处理对壳鸡蛋表面大肠杆菌的杀菌机理及动力学分析
20
作者 张雅琪 迟玉杰 迟媛 《食品科学》 EI CAS CSCD 北大核心 2024年第4期26-34,共9页
为了探究超声蒸汽协同处理对蛋壳表面大肠杆菌的预测杀菌效果以及细菌损伤和死亡的机制,本研究以大肠杆菌为研究对象,构建了超声蒸汽协同处理对蛋壳表面大肠杆菌的杀菌动力学模型。通过控制蛋壳表面细菌液的浓度,讨论超声、蒸汽和超声... 为了探究超声蒸汽协同处理对蛋壳表面大肠杆菌的预测杀菌效果以及细菌损伤和死亡的机制,本研究以大肠杆菌为研究对象,构建了超声蒸汽协同处理对蛋壳表面大肠杆菌的杀菌动力学模型。通过控制蛋壳表面细菌液的浓度,讨论超声、蒸汽和超声与蒸汽协同作用对大肠杆菌的灭活作用,并与商业化杀菌中常用的次氯酸钠浸泡法进行比较。采用线性模型、Weibull模型、Log-Logistic模型和Modified Gompertz模型拟合了超声辅助蒸汽处理大肠杆菌的灭活曲线,对灭菌前后细胞形态的破坏程度和细胞内容物的泄漏情况进行分析。结果表明,经过180 s的150 W超声预处理和3 s的蒸汽处理后,大肠杆菌总数的对数值从6.26下降到2.04,死亡率达到67%。超声辅助蒸汽处理的灭菌过程更符合非线性动力学模型,且随着超声强度的增加和蒸汽处理时间的延长,Weibull模型更适合描述灭菌的动态过程。此外,协同处理会破坏大肠杆菌的超微结构以及菌体细胞的外部结构,使菌体细胞质溢出,从而改变膜的通透性。因此,超声协同蒸汽处理会加剧细菌的变形和损伤,导致细菌死亡。实验结果可为蛋壳表面大肠杆菌的灭活提供理论依据,综合贮藏期鸡蛋品质分析结果,该方法在禽蛋洁蛋生产中具有一定的应用前景。 展开更多
关键词 鸡蛋 超声协助蒸汽处理 杀菌 微生物
下载PDF
上一页 1 2 58 下一页 到第
使用帮助 返回顶部