期刊文献+
共找到824篇文章
< 1 2 42 >
每页显示 20 50 100
Transcatheter aortic valve replacement in low-risk young population:A double edge sword?
1
作者 Sukhdeep Bhogal Akash Batta 《World Journal of Cardiology》 2024年第4期177-180,共4页
Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediat... Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediate to highsurgical risk patients.In 2019,the United States Food and Drug Administration approved TAVR in low-risk patients based on two randomized trials.However,these breakthrough trials excluded patients with certain unfavorable anatomies and odd profiles.While currently there is no randomized study of TAVR in young patients,it may be preferred by the young population given the benefits of early discharge,shorter hospital stay,and expedite recovery.Nonetheless,it is important to ruminate various factors including lifetime expectancy,risk of pacemaker implantation,and the need for future valve or coronary interventions in young cohorts before considering TAVR in these patients.Furthermore,the data on long-term durability(>10 years)of TAVR is still unknown given most of the procedures were initially performed in the high or prohibitive surgical risk population.Thus,this editorial aims to highlight the importance of considering an individualized approach in young patients with consideration of various factors including lifetime expectancy while choosing TAVR against surgical aortic valve replacement. 展开更多
关键词 Transcatheter aortic valve replacement Surgical aortic valve replacement Pacemaker implantation Coronary re-access Structural deterioration
下载PDF
Electric-controlled pressure relief valve for enhanced safety in liquid-cooled lithium-ion battery packs
2
作者 Yuhang Song Jidong Hou +6 位作者 Nawei Lyu Xinyuan Luo Jingxuan Ma Shuwen Chen Peihao Wu Xin Jiang Yang Jin 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第3期98-109,I0004,共13页
The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above... The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above IP65,which can trap flammable and explosive gases from battery thermal runaway and cause explosions.This poses serious safety risks and challenges for LCBESS.In this study,we tested overcharged battery inside a commercial LCBP and found that the conventionally mechanical pressure relief valve(PRV) on the LCBP had a delayed response and low-pressure relief efficiency.A realistic 20-foot model of an energy storage cabin was constructed using the Flacs finite element simulation software.Comparative studies were conducted to evaluate the pressure relief efficiency and the influence on neighboring battery packs in case of internal explosions,considering different sizes and installation positions of the PRV.Here,a newly developed electric-controlled PRV integrated with battery fault detection is introduced,capable of starting within 50 ms of the battery safety valve opening.Furthermore,the PRV was integrated with the battery management system and changed the battery charging and discharging strategy after the PRV was opened.Experimental tests confirmed the efficacy of this method in preventing explosions.This paper addresses the safety concerns associated with LCBPs and proposes an effective solution for explosion relief. 展开更多
关键词 Pressure relief valve Liquid-cooled battery pack Explosion Flacs
下载PDF
Effect of safety valve types on the gas venting behavior and thermal runaway hazard severity of large-format prismatic lithium iron phosphate batteries
3
作者 Zhuangzhuang Jia Yuanyuan Min +5 位作者 Peng Qin Wenxin Mei Xiangdong Meng Kaiqiang Jin Jinhua Sun Qingsong Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第2期195-207,I0006,共14页
The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the ... The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design. 展开更多
关键词 Lithium iron phosphate battery Safety valve Thermal runaway Gas venting behavior Thermal runaway hazard severity Gray-fuzzy analytic hierarchy process
下载PDF
Isogeometric Analysis of Hyperelastic Material Characteristics for Calcified Aortic Valve
4
作者 Long Chen Ting Li +3 位作者 Liang Liu Wenshuo Wang Xiaoxiao Du Wei Wang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第6期2773-2806,共34页
This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcathete... This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcatheter heart valve replacement(TAVR)procedures.In order to facilitate this exploration,it derives pertinent formulas for 3D multi-material isogeometric hyperelastic analysis based on Hounsfield unit(HU)values,thereby unlocking foundational capabilities for isogeometric analysis in calcified aortic valves.A series of uniaxial and biaxial tensile tests is executed to obtain an accurate constitutive model for calcified active valves.To mitigate discretization errors,methodologies for reconstructing volumetric parametric models,integrating both geometric and material attributes,are introduced.Applying these analytical formulas,constitutive models,and precise analytical models to isogeometric analyses of calcified valves,the research ascertains their close alignment with experimental results through the close fit in displacement-stress curves,compellingly validating the accuracy and reliability of the method.This study presents a step-by-step approach to analyzing themechanical characteristics of patient-specific valves obtained fromCT images,holding significant clinical implications and assisting in the selection of treatment strategies and surgical intervention approaches in TAVR procedures. 展开更多
关键词 Calcified aortic valves tensile test constitutive relations CT reconstruction isogeometric hyperelastic analysis
下载PDF
Risk of permanent pacemaker implantation following transcatheter aortic valve replacement:Which factors are most relevant?
5
作者 Akash Batta Juniali Hatwal 《World Journal of Cardiology》 2024年第2期49-53,共5页
Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized ... Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized controlled trials has resulted in an exponential rise in the use of TAVR even in the low-risk patients.However,this is not without challenges.Need for permanent pacemaker(PPM)post-TAVR remains the most frequent and clinically relevant challenge.Naturally,identifying risk factors which predispose an individual to develop high grade conduction block post-TAVR is important.Various demographic factors,electrocardiographic features,anatomic factors and procedural characteristics have all been linked to the development of advanced conduction block and need for PPM following TAVR.Amongst these electrophysiological variables,most notably a prolonged QRS>120 ms regardless of the type of conduction block seems to be one of the strongest predictors on logistic regression models.The index study by Nwaedozie et al highlights that patients requiring PPM post-TAVR had higher odds of having a baseline QRS>120 ms and were more likely to be having diabetes mellitus that those who did not require PPM. 展开更多
关键词 Transcatheter aortic valve replacement Permanent pacemaker Diabetes mellitus QRS duration Electrophysiological variables
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
6
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Pacemaker post transcatheter aortic valve replacement:A multifactorial risk?
7
作者 Stephane Noble Karim Bendjelid 《World Journal of Cardiology》 2024年第4期168-172,共5页
Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have a... Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate.In this regard,long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance. 展开更多
关键词 Transcatheter aortic valve replacement Permanent pacemaker implantation Conduction abnormalities Right bundle branch block Left bundle branch block
下载PDF
Low-temperature characteristicsof rubbers and performance testsof type 120 emergencyvalve diaphragms
8
作者 Ming Gao Anhui Pan +5 位作者 Yi Huang Jiaqi Wang Yan Zhang Xiao Xie Huanre Han Yinghua Jia 《Railway Sciences》 2024年第1期47-58,共12页
Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resista... Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resistance and low-temperature resistance,respectively.In order to develop type 120 emergency valverubber diaphragms with long-life and high-performance,low-temperatureresistant CR and NR were processed.Design/methodology/approach–The physical properties of the low-temperature-resistant CR and NRwere tested by low-temperature stretching,dynamic mechanical analysis,differential scanning calorimetryand thermogravimetric analysis.Single-valve and single-vehicle tests of type 120 emergency valves werecarried out for emergency diaphragms consisting of NR and CR.Findings–The low-temperature-resistant CR and NR exhibited excellent physical properties.The elasticityand low-temperature resistance of NR were superior to those of CR,whereas the mechanical properties of thetwo rubbers were similar in the temperature range of 0℃–150℃.The NR and CR emergency diaphragms metthe requirements of the single-valve test.In the low-temperature single-vehicle test,only the low-temperaturesensitivity test of the NR emergency diaphragm met the requirements.Originality/value–The innovation of this study is that it provides valuable data and experience for futuredevelopment of type 120 valve rubber diaphragms. 展开更多
关键词 Natural rubber Chloroprene rubber Low-temperature characteristic 120 emergency valve DIAPHRAGM
下载PDF
Animal Model of Aortic Valve Calcification: Their Methodology Helps Us Understand Aortic Valve Calcification
9
作者 Yinze Wei Zhen Wang +1 位作者 Miao Chen Liang Ma 《Advances in Bioscience and Biotechnology》 CAS 2024年第4期235-268,共34页
Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying ... Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying mechanisms remains incomplete, and available treatment options are limited and risky. A more comprehensive understanding of the biology of CAVD is essential to identify new therapeutic strategies. Animal models have played a crucial role in advancing our knowledge of CAVD and exploring potential treatments. However, these models have inherent limitations as they cannot fully replicate the complex physiological mechanisms of human CAVD. In this review, we examine various CAVD models ranging from pigs to mice, highlighting the unique characteristics of each model to enhance our understanding of CAVD. While these models offer valuable insights, they also have limitations and shortcomings. We propose that the guide wire model shows promise for future CAVD research, and streamlining the methodology could enhance our understanding and expand the research scope in this field. 展开更多
关键词 Animal Model Aortic valve Stenosis CALCIFICATION CARDIOVASCULAR
下载PDF
Early Prosthetic Valve Endocarditis with Mycobacterium Tuberculosis after Mitral Valve Replacement: A Case Report
10
作者 Papa Amath Diagne Mory Camara +12 位作者 Papa Ousmane Ba Momar Sokhna Diop Moussa Samba Abdou Lahad Mbengue Jean Claude Ndiogou Dione Myriam Bizrane Marième Soda Mbaye Moussa Seck Diop Toudiani Malam Kaka Papa Salmane Ba Papa Adama Dieng Amadou Gabriel Ciss Assane Ndiaye 《World Journal of Cardiovascular Surgery》 2024年第3期33-40,共8页
Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mit... Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mitral valve replacement, with a favorable clinical course following anti-tuberculosis treatment. Case Presentation: We report a 24-year-old male patient, admitted to the cardiac surgery department of the Fann Hospital (Dakar, Senegal), for the management of severe mixed (rheumatic and endocarditic) mitral insufficiency with associated tricuspid insufficiency. He had a history of recurrent angina and polyarthralgia in childhood, was hospitalized several times for refractory global cardiac decompensation, and for a suspected infective endocarditis a month before his admission. On admission, the clinical examination revealed signs suggestive of mitral and tricuspid insufficiency. Transthoracic echocardiography revealed severe post-endocarditic mitral insufficiency with A3 amputation, highly mobile 15 mm vegetations on the free edge of the large valve, moderate tricuspid insufficiency, and severe pulmonary artery hypertension. Mechanical mitral valve replacement and tricuspid valve annuloplasty using autologous pericardial strip were performed via median sternotomy. After ten days, the patient presented with global cardiac decompensation associated with a clinico-biological infectious syndrome, and tans-oesophageal echography revealed an abscess at the sinotubular junction, communicating with the aorta. A thoraco-abdomino-pelvic CT scan was done, which revealed a bilateral alveolar-interstitial syndrome with mediastinal lymphadenopathy. Anti-tuberculosis treatment with RHZE was initiated for 06 months. The clinical course was favorable. Conclusion: Tuberculous endocarditis in prostheses is a serious complication of heart valve replacement surgery, which may evolve favorably under medical treatment. 展开更多
关键词 Tuberculous Endocarditis Prosthetic valve Endocarditis Mycobacterium Tuberculosis
下载PDF
The Impact of Temperature on the Electromagnet and Structural Optimization of a Solenoid Valve
11
作者 Zhixiong Tang Zhijun Feng 《Journal of Electronic Research and Application》 2024年第1期28-35,共8页
The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force... The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force is determined.Electrothermal coupling simulation using COMSOL is conducted,optimizing the outer diameter and length structure parameters of the coil.It is established that the heat dissipation of the coil is influenced by its outer diameter.Subsequently,based on optimized coil structure parameters,an orthogonal experimental design method combined with Ansys Maxwell is employed for simulation solution analysis to study the impact of structural parameters such as length,position,front and rear angles of the magnetic barrier ring in the iron core,armature length,and through-hole size on electromagnetic force.Optimal structural parameters are identified.Results indicate a decrease in steady-state electromagnet temperature by 3-4℃,an increase in the initial electromagnetic force by 32.63%,and a rise in the maximum electromagnetic force by 27.10%. 展开更多
关键词 Solenoid valve ELECTROMAGNET TEMPERATURE Electromagnetic force
下载PDF
In-Hospital Outcomes in Minimally Invasive Mitral Valve Surgery: First Results in a Brazilian Single Center
12
作者 Daniel de Magalhães Freitas João Alberto Pansani +4 位作者 Max Weyler Nery Stanlley de Oliveira Loyola Maurício Lopes Prudente Giulliano Gardenghi Artur Henrique de Souza 《Open Journal of Thoracic Surgery》 2024年第1期17-28,共12页
Introduction: Treatments for cardiovascular diseases have increasingly evolved with the tendency to offer minimally invasive or transcatheter procedures instead of conventional sternotomy surgery. In this context, we ... Introduction: Treatments for cardiovascular diseases have increasingly evolved with the tendency to offer minimally invasive or transcatheter procedures instead of conventional sternotomy surgery. In this context, we highlight minimally invasive mitral valve surgery (MIMVS), which has been shown to be an increasingly solid option with some superior results when compared to the conventional technique: better pain control, shorter hospital stays, shorter recovery time, shorter readmission rate in the first postoperative year, better aesthetic results, and lower overall cost. Aim: This study aims to evaluate the stages of MIMVS, by primary mitral valve consultation, in our service and compare these results with data from the literature. Methods: All electronic medical records of patients who underwent MIMVS for primary mitral valve injury in the Encore Hospital from January 2020 to February 2023 were analyzed. Tabulation and statistical analysis were performed using the Microsoft Excel<sup>®</sup> program. Quantitative variables were presented as means, standard deviations. Results: 46 patients were enrolled in our study (Age: 59.1 ± 12.4 years old;60.8% Female, BMI: 26 ± 4.4 Kg/m<sup>2</sup>, Low risk STS score: 82.6%). The observed 30-day mortality was 2.1%, plastic rate of 23.9%, blood transfusion rate of 41.3%, length of stay in an intensive care bed (ICB) of 3.3 ± 3.3 days and hospital stay of 6.4 ± 5.1 days. Conclusions: We noticed that the MIMVS results carried out in our service agree with data from national and international literature with approximately 1.3 days more hospitalization in ICB. 展开更多
关键词 Minimally Invasive Surgical Procedures Mitral valve Outcome Assessment Health Care
下载PDF
Novel predictors of permanent pacemaker implantation following transcatheter aortic valve replacement 被引量:2
13
作者 Somto Nwaedozie Haibin Zhang +7 位作者 Javad Najjar Mojarrab Param Sharma Paul Yeung Peter Umukoro Deepa Soodi Rachel Gabor Kelley Anderson Romel Garcia-Montilla 《World Journal of Cardiology》 2023年第11期582-598,共17页
BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Pote... BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Potential novel predictors of post-TAVR PPM,like QRS duration,QTc prolongation,and supraventricular arrhythmias,have been poorly studied.AIM To evaluate the effects of baseline nonspecific interventricular conduction delay and supraventricular arrhythmia on post-TAVR PPM requirement and determine the impact of PPM implantation on clinical outcomes.METHODS RESULTS Out of the 357 patients that met inclusion criteria,the mean age was 80 years,188(52.7%)were male,and 57(16%)had a PPM implantation.Baseline demographics,valve type,and cardiovascular risk factors were similar except for type II diabetes mellitus(DM),which was more prevalent in the PPM cohort(59.6%vs 40.7%;P=0.009).The PPM cohort had a significantly higher rate of pre-procedure right bundle branch block,prolonged QRS>120 ms,prolonged QTc>470 ms,and supraventricular arrhythmias.There was a consistently significant increase in the odds ratio(OR)of PPM implantation for every 20 ms increase in the QRS duration above 100 ms:QRS 101-120[OR:2.44;confidence intervals(CI):1.14-5.25;P=0.022],QRS 121-140(OR:3.25;CI:1.32-7.98;P=0.010),QRS 141-160(OR:6.98;CI:3.10-15.61;P<0.001).After model adjustment for baseline risk factors,the OR remained significant for type II DM(aOR:2.16;CI:1.18-3.94;P=0.012),QRS>120(aOR:2.18;CI:1.02-4.66;P=0.045)and marginally significant for supraventricular arrhythmias(aOR:1.82;CI:0.97-3.42;P=0.062).The PPM cohort had a higher adjusted OR of heart failure(HF)hospitalization(aOR:2.2;CI:1.1-4.3;P=0.022)and nonfatal myocardial infarction(MI)(aOR:3.9;CI:1.1-14;P=0.031)without any difference in mortality(aOR:1.1;CI:0.5-2.7;P=0.796)at one year.CONCLUSION Pre-TAVR type II DM and QRS duration>120,regardless of the presence of bundle branch blocks,are predictors of post-TAVR PPM.At 1-year post-TAVR,patients with PPM have higher odds of HF hospitalization and MI. 展开更多
关键词 Transcatheter aortic valve replacement Balloon-expandable valve Self-expandable valve Myocardial infarction Left bundle-branch block Nonspecific inter-ventricular defect Coronary artery bypass graft Coronary artery disease
下载PDF
Unicuspid Aortic Valve, an Extremely Rare Congenital Anomaly in Adults: A Systemic Review
14
作者 Dilesha Dilangi Kumanayaka Alex Otto +4 位作者 Mit Chauhan Vadim Belinschi Noreen Mirza Mohammad Nabil Rayad Addi Suleiman 《World Journal of Cardiovascular Diseases》 2023年第6期283-288,共6页
The most common congenital heart defect is the bicuspid aortic valve (BAV) occurring with fusion of one of the three-valve commissures. A rarer valvular phenomenon is the unicuspid aortic valve (UAV) which has an esti... The most common congenital heart defect is the bicuspid aortic valve (BAV) occurring with fusion of one of the three-valve commissures. A rarer valvular phenomenon is the unicuspid aortic valve (UAV) which has an estimated prevalence of 0.02% in the adult population. Two morphologic subtypes of UAV exist: the earlier presenting, acommissural UAV and the later appearing unicommissural. To better characterize and manage patients with UAVs, a systematic review of this rare phenomenon was performed. The objective of our study was to conduct a systematic review of adequate case studies involving UAV patients to describe patient characteristics, clinical presentation, management, and common sequela featured there within. The mean age of presentation in this review was 35.6 years. When diagnosing UAV, TEE was the most utilized diagnostic modality (65%) followed by intraoperative diagnosis (17%) discovered with valve repair or incidentally during another procedure. TTE was utilized to diagnose only 7% of the cases reviewed likely owing to the difficulty and inaccuracies in identifying UAV with this method that were previously established by multiple series. Interventional options for UAV are balloon versus surgical valvotomy, aortic valve replacement, Ross procedure and aortic root replacement. They are performed on an individual basis and all cases ultimately require aortic valve replacement (AVR) or Ross procedure (to avoid anticoagulation). Aortic root replacement is additionally required if aortic root/ascending aorta diameter exceeds 4.5 cm. In this review, Aortic aneurysm (16%) cases resulted in surgical interventions. There may be a need to implant permanent pacemaker (in 3% - 8%) during AVR when calcified UAV has calcification extending into interventricular septum. 展开更多
关键词 Unicuspid Aortic valve Bicuspid Aortic valve Heart Defects Unicommisural valve
下载PDF
An Analysis of the Static and Dynamic Behavior of the Hydraulic Compensation System of a Multichannel Valve
15
作者 Jikang Xu Ruichuan Li +5 位作者 Yi Cheng Yanchao Li Junru Yang Chenyu Feng Xinkai Ding Huazhong Zhang 《Fluid Dynamics & Materials Processing》 EI 2023年第7期1817-1836,共20页
Electro-hydraulic proportional valve is the core control valve in many hydraulic systems used in agricultural and engineering machinery.To address the problem related to the large throttling losses and poor stability ... Electro-hydraulic proportional valve is the core control valve in many hydraulic systems used in agricultural and engineering machinery.To address the problem related to the large throttling losses and poor stability typically associated with these valves,here,the beneficial effects of a triangular groove structure on the related hydraulic response are studied.A mathematical model of the pressure compensation system based on the power-bond graph method is introduced,and the AMESim software is used to simulate its response.The results show that the triangular groove structure increases the jet angle and effectively compensates for the hydrodynamic force.The steady-state differential pressure at the valve port of the new pressure compensation structure was 0.65 MPa.Furthermore,experimental results show that the pressure difference at the main valve port is 0.73 MPa,and that the response time is less than 0.2 s.It is concluded that the new compensation structure has good pressure compensation response characteristics. 展开更多
关键词 Electrohydraulic proportional valve spool shape pressure compensation valve port differential pressure response time
下载PDF
Outcomes of Self-Expanding Transcatheter Pulmonary Valves:Extended Follow-Up of a Prospective Trial
16
作者 Jingnan Zhang Junyi Wan +6 位作者 Yihang Li Yu Han Jiahua Pan Fang Fang Shiliang Jiang Xiangbin Pan Gejun Zhang 《Congenital Heart Disease》 SCIE 2023年第2期219-234,共16页
Background:The Venus-P valve was the first self-expanding valve used world-wide for transcatheter pulmonary valve replacement(TPVR)in patients with severe pulmonary regurgitation(PR).We intended to report the extended... Background:The Venus-P valve was the first self-expanding valve used world-wide for transcatheter pulmonary valve replacement(TPVR)in patients with severe pulmonary regurgitation(PR).We intended to report the extended follow-up results from the prospective trial(No.NCT02590679).Methods:A total of 38 patients with severe PR(mean age 24.2±13.2)were included.Follow-up data were obtained after implanted at 1,6,and 12 months and yearly after.The frame geometry was assessed on post-implant computer tomography(CT)scanning by calculating the non-circularity[circularity ratio(minimum diameter/maximum diameter)<0.9]and under-expansion[expansion ratio(derived external valve area/nominal external valve area)<0.9).Adverse events(all-cause mortality,reintervention,valve dysfunction,stent fracture and endocarditis)were recorded.Results:All valves were implanted successfully with normal function at discharge.Geometric CT analysis showed underexpanded valve was detected in 22 patients(63%)and non-circular valve was seen in 16 patients(46%).During a median follow-up of 4.8 years(range 0.3-8.1),there were 1 death and 1 surgical explant,both resulting from endocarditis.Five-year freedom from valve dysfunction and stent fracture were 84.8%(95%CI 74.8-94.7)and 83.5%(95%CI 73.8-93.2).Endocarditis occurred in 3 patients at a median time of 7 months.Stent fracture was more common in patients with non-circularity stents.Conclusion:TPVR using Venus-P valve is associated with favorable outcomes at 5 years.Non-circular shapes in the valve level may have a higher risk of stent fracture. 展开更多
关键词 Congenital heart disease pulmonary regurgitation transcatheter pulmonary valve replacement Venus-P valve
下载PDF
Isolated Tricuspid Valve Repair and Right Atrial Plication Performed Using a Beating-Heart Technique for Atrial Functional Tricuspid Valve Regurgitation
17
作者 Kayo Sugiyama Hirotaka Watanuki +2 位作者 Masato Tochii Daisuke Koiwa Katsuhiko Matsuyama 《Open Journal of Thoracic Surgery》 2023年第2期7-16,共10页
Background: Isolated tricuspid valve disease remains a controversial indication for surgical intervention. Many patients referred for surgery already have a poor clinical condition and an advanced New York Heart Assoc... Background: Isolated tricuspid valve disease remains a controversial indication for surgical intervention. Many patients referred for surgery already have a poor clinical condition and an advanced New York Heart Association functional class. There is no consensus on the optimal surgical technique for this condition, including on whether to perform the procedure on a beating or an arrested heart and whether to perform valve repair or replacement. Methods: We analyzed four case series between 2015 and 2022 in which patients with secondary tricuspid regurgitation (TR) underwent valve repair on a beating heart and right atrial plication for a dilated right atrium. The TRI-SCORE was calculated for each patient. Results: All patients experienced a favorable postoperative course with significant improvements in heart failure symptoms. TR was markedly reduced;however, in one patient with concomitant mitral regurgitation (MR) and a high TRI-SCORE, MR worsened postoperatively. This patient later died from unknown causes due to multiple comorbidities in the late phase. Conclusions: Tricuspid valve repair on a beating heart was effective for improving the cardiac function, and the TRI-SCORE proved useful as a preoperative risk assessment tool. The underlying mechanism by which TR exacerbates MR requires further investigation. 展开更多
关键词 Isolated Tricuspid valve Surgery Beating-Heart Surgery Right Atrial Plication Atrial Functional Tricuspid valve Regurgitation TRI-SCORE
下载PDF
Research of vibrations effect on hydraulic valves in military vehicles 被引量:1
18
作者 MichałStosiak Mykola Karpenko +2 位作者 Olegas Prentkovskis Adam Deptuła Paulius Skackauskas 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2023年第12期111-125,共15页
The paper discusses minimizing the effect of external mechanical vibration on hydraulic valves in different military hydraulic drive systems.The current research work presents an analysis of the potential to reduce vi... The paper discusses minimizing the effect of external mechanical vibration on hydraulic valves in different military hydraulic drive systems.The current research work presents an analysis of the potential to reduce vibration on the valve casing by installing a valve flexibly on a vibrating surface,i.e.,by introducing a material with known stiffness and damping characteristics between the valve casing and the vibrating surface-a steel spring package or special cushions made of elastomer material or of oilresistant rubber.The article also demonstrates that elastomer cushions placed inside the valve casingbetween the casing and the centering springs-can be used as a supplementary or alternative solution in the analyzed method for mitigating the transfer of vibrations.By using materials with appropriately selected elastic and dissipative properties,the effectiveness of vibro-isolation can be increased.The presented theoretical analyzes by linear and non-linear mathematical models have been verified experimentally. 展开更多
关键词 Military application Hydraulic valve VIBRATION Passive vibro-isolation Spring package
下载PDF
Trilayer anisotropic structure versus randomly oriented structure in heart valve leaflet tissue engineering 被引量:1
19
作者 Yuriy Snyder Soumen Jana 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第4期423-438,共16页
It has been hypothesized that leaflet substrates with a trilayer structure and anisotropicmechanical properties could be useful for the production of functional and long-lasting tissue-engineered leaflets.To investiga... It has been hypothesized that leaflet substrates with a trilayer structure and anisotropicmechanical properties could be useful for the production of functional and long-lasting tissue-engineered leaflets.To investigate the influence of the anisotropic structural and mechanical characteristics of a substrate on cells,in this study,we electrospun trilayer anisotropic fibrous substrates and randomly oriented isotropic fibrous substrates(used as controls)from polycaprolactone polymers.Consequently,the random substrates had higher radial and lower circumferential tensile properties than the trilayer substrates;however,they had similar flexural properties.Porcine valvular interstitial cells cultured on both substrates produced random and trilayer cell-cultured constructs,respectively.The trilayer cell-cultured constructs had more anisotropic mechanical properties,17%higher cellular proliferation,14%more extracellular matrix(i.e.,collagen and glycosaminoglycan)production,and superior gene and protein expression,suggesting that more cells were in a growth state in the trilayer constructs than in the random constructs.Furthermore,the random and radial layers of the trilayer constructs had more vimentin,collagen,transforming growth factor-beta 1(TGF-ß1),transforming growth factor-beta 3(TGF-ß3)gene expression than in the circumferential layer of the constructs.This study verifies that the differences in structural,tensile,and anisotropic properties of the trilayer and random substrates influence the characteristics of the cells and ECM in the constructs. 展开更多
关键词 Heart valve leaflet TRILAYER Tissue engineering Fiber ELECTROSPINNING
下载PDF
Influence of quick release valve on braking performance and coupler force of heavy haul train 被引量:1
20
作者 Wei Wei Yuan Zhang +1 位作者 Jun Zhang Xubao Zhao 《Railway Engineering Science》 2023年第2期153-161,共9页
We establish a simulation model based on the theory of air flow to analyze the accelerated release effect of the quick release valve inside the air brake control valve.In addition, the combined simulation system of tr... We establish a simulation model based on the theory of air flow to analyze the accelerated release effect of the quick release valve inside the air brake control valve.In addition, the combined simulation system of train air brake system and longitudinal train dynamics is used to analyze how the parameters of the quick release valve in the 120/120–1 brake control valve affect the propagation characteristics of the train brake pipe pressure wave, the release action range of the accelerated brake, and the longitudinal coupler force for a 20,000-ton heavy haul train on the section of the Datong–Qinhuangdao Railway. The results show that the quick release valve can effectively accelerate the rising speed of the train brake pipe pressure during the initial release, as the accelerated release effect is evident before the train brake pipe pressure reaches582 k Pa. The quick release valve can effectively accelerate the release of the rear cars, reducing the longitudinal coupler force impact due to time delay of the release process. The quick release valve can effectively reduce the tensile coupler force in the train by as much as 20% in certain cases. 展开更多
关键词 Brake system Release characteristics Quick release valve Coupler force Heavy haul train
下载PDF
上一页 1 2 42 下一页 到第
使用帮助 返回顶部