期刊文献+
共找到45,150篇文章
< 1 2 250 >
每页显示 20 50 100
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
1
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Brain protective effect of dexmedetomidine vs propofol for sedation during prolonged mechanical ventilation in non-brain injured patients
2
作者 Hong-Xun Yuan Li-Na Zhang +1 位作者 Gang Li Li Qiao 《World Journal of Psychiatry》 SCIE 2024年第3期370-379,共10页
BACKGROUND Dexmedetomidine and propofol are two sedatives used for long-term sedation.It remains unclear whether dexmedetomidine provides superior cerebral protection for patients undergoing long-term mechanical venti... BACKGROUND Dexmedetomidine and propofol are two sedatives used for long-term sedation.It remains unclear whether dexmedetomidine provides superior cerebral protection for patients undergoing long-term mechanical ventilation.AIM To compare the neuroprotective effects of dexmedetomidine and propofol for sedation during prolonged mechanical ventilation in patients without brain injury.METHODS Patients who underwent mechanical ventilation for>72 h were randomly assigned to receive sedation with dexmedetomidine or propofol.The Richmond Agitation and Sedation Scale(RASS)was used to evaluate sedation effects,with a target range of-3 to 0.The primary outcomes were serum levels of S100-βand neuron-specific enolase(NSE)every 24 h.The secondary outcomes were remifentanil dosage,the proportion of patients requiring rescue sedation,and the time and frequency of RASS scores within the target range.RESULTS A total of 52 and 63 patients were allocated to the dexmedetomidine group and propofol group,respectively.Baseline data were comparable between groups.No significant differences were identified between groups within the median duration of study drug infusion[52.0(IQR:36.0-73.5)h vs 53.0(IQR:37.0-72.0)h,P=0.958],the median dose of remifentanil[4.5(IQR:4.0-5.0)μg/kg/h vs 4.6(IQR:4.0-5.0)μg/kg/h,P=0.395],the median percentage of time in the target RASS range without rescue sedation[85.6%(IQR:65.8%-96.6%)vs 86.7%(IQR:72.3%-95.3),P=0.592],and the median frequency within the target RASS range without rescue sedation[72.2%(60.8%-91.7%)vs 73.3%(60.0%-100.0%),P=0.880].The proportion of patients in the dexmedetomidine group who required rescue sedation was higher than in the propofol group with statistical significance(69.2%vs 50.8%,P=0.045).Serum S100-βand NSE levels in the propofol group were higher than in the dexmedetomidine group with statistical significance during the first six and five days of mechanical ventilation,respectively(all P<0.05).CONCLUSION Dexmedetomidine demonstrated stronger protective effects on the brain compared to propofol for long-term mechanical ventilation in patients without brain injury. 展开更多
关键词 DEXMEDETOMIDINE PROPOFOL SEDATION Prolonged mechanical ventilation Brain protective
下载PDF
Driving pressure in mechanical ventilation:A review
3
作者 Syeda Farheen Zaidi Asim Shaikh +2 位作者 Daniyal Aziz Khan Salim Surani Iqbal Ratnani 《World Journal of Critical Care Medicine》 2024年第1期15-27,共13页
Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP lev... Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP levels have also been shown to closely impact hard endpoints such as mortality.Considering this,conducting an in-depth review ofΔP as a unique,outcome-impacting therapeutic modality is extremely important.There is a need to understand the subtleties involved in making sureΔP levels are optimized to enhance outcomes and minimize harm.We performed this narrative review to further explore the various uses ofΔP,the different parameters that can affect its use,and how outcomes vary in different patient populations at different pressure levels.To better utilizeΔP in MV-requiring patients,additional large-scale clinical studies are needed. 展开更多
关键词 Driving pressure Acute respiratory distress syndrome MORTALITY Positive end-expiratory pressure Ventilator induced lung injury Mechanical ventilation
下载PDF
Clinical evaluation of ventilation mode on acute exacerbation of chronic obstructive pulmonary disease with respiratory failure
4
作者 Jun-Jun Wang Zhong Zhou Li-Ying Zhang 《World Journal of Clinical Cases》 SCIE 2023年第26期6040-6050,共11页
BACKGROUND At present,understanding of the most effective ventilation methods for treating chronic obstructive pulmonary disease(COPD)patients experiencing acute worsening symptoms and respiratory failure remains rela... BACKGROUND At present,understanding of the most effective ventilation methods for treating chronic obstructive pulmonary disease(COPD)patients experiencing acute worsening symptoms and respiratory failure remains relatively limited.This report analyzed the efficiency and side effects of various ventilation techniques used for individuals experiencing an acute COPD exacerbation.AIM To determine whether pressure-controlled ventilation(PCV)can lower peak airway pressures(PAPs)and reduce the incidence of barotrauma compared to volume-controlled ventilation(VCV),without compromising clinical outcomes and oxygenation parameters.METHODS We have evaluated 600 patients who were hospitalized due to a severe COPD exacerbation,with 400 receiving mechanical ventilation for the respiratory failure.The participants were divided into two different groups,who were administered either VCV or PCV,along with appropriate management.We thereafter observed patients'attributes,clinical factors,and laboratory,radiographic,and arterial blood gas evaluations at the start and during their stay in the intensive care unit(ICU).We have also employed appropriate statistical methods for the data analysis.RESULTS Both the VCV and PCV groups experienced significant enhancements in the respiratory rate,tidal volume,and arterial blood gas values during their time in the ICU.However,no significant distinctions were detected between the groups in terms of oxygenation indices(partial pressures of oxygen/raction of inspired oxygen ratio)and partial pressures of carbon dioxide improvements.There was no considerable disparity observed between the VCV and PCV groups in the hospital mortality(32%vs 28%,P=0.53),the number of days of ICU stay[median interquartile range(IQR):9(6-14)d vs 8(5-13)d,P=0.41],or the duration of the mechanical ventilation[median(IQR):6(4-10)d vs 5(3-9)d,P=0.47].The PCV group displayed lower PAPs compared to the VCV group(P<0.05)from the beginning of mechanical ventilation until extubation or ICU departure.The occurrence of barotrauma was considerably lower in the PCV group in comparison to the VCV group(6%vs 16%,P=0.03).CONCLUSION Both VCV and PCV were found to be effective in treating patients with acute COPD exacerbation.However,PCV was associated with lower PAPs and a significant decrease in barotrauma,thus indicating that it might be a safer ventilation method for this group of patients.However,further large-scale study is necessary to confirm these findings and to identify the best ventilation approach for patients experiencing an acute COPD exacerbation. 展开更多
关键词 Chronic obstructive pulmonary disease Mechanical ventilation Volume-controlled ventilation Pressurecontrolled ventilation BAROTRAUMA Respiratory failure
下载PDF
Invasive versus non-invasive ventilation in patients with COVID-19 pneumonia:A retrospective study
5
作者 Abhijit Nair Jacob Paul +1 位作者 Ajay Yadav Khalid Al Sawafi 《Journal of Acute Disease》 2023年第2期61-66,共6页
Objective:To compare the survival and length of stay of invasive ventilation(IV)with those of non-invasive ventilation(NIV)in patients with COVID-19 acute respiratory distress syndrome in a single hospital from May 20... Objective:To compare the survival and length of stay of invasive ventilation(IV)with those of non-invasive ventilation(NIV)in patients with COVID-19 acute respiratory distress syndrome in a single hospital from May 2020 to March 2021.Methods:After obtaining approval from the Hospital Director,the data of COVID-19 patients including demographics,type of respiratory support(non-invasive ventilation or invasive ventilation),duration of ventilation,length of stay,discharge,and death were collected and analyzed.Results:Out of the 152 patients identified,134 patients were analyzed.The median intubation days were 10.0(Q1:3.5,Q3:13.5)in the IV group and 0.0(Q1:0.0,Q3:0.0)days in the NIV-only group.Out of the 101 patients who received NIV,43 patients were subsequently intubated due to failure of NIV.Of the 63 patients(47.01%)who died,22(66.66%)were from the IV group and 40(92.02%)were from the NIV-followed-by-intubation group,and 1(1.72%)were from the NIV-only group.Multivariate analysis showed that the presence of a respiratory comorbidity(OR=16.56,95%CI=1.56-175.48,P=0.02)was an independent predictor of survival.Conclusions:Respiratory co-morbidity is a significant adverse predictor of survival outcome.The decision on the type of respiratory support should be made on a patient-to-patient basis. 展开更多
关键词 Acute respiratory distress syndrome COVID-19 Intensive care unit Invasive ventilation MORBIDITY MORTALITY Non-invasive ventilation
下载PDF
Mechanical ventilation and outcomes in COVID-19 patients admitted to intensive care unit in a low-resources setting: A retrospective study
6
作者 Sarakawabalo Assenouwe Tabana Essohanam Mouzou +7 位作者 Ernest Ahounou Lidaw Déassoua Bawe Awèréou Kotosso Koffi Atsu Aziagbe Eyram Makafui Yoan Amekoudi Mamoudou Omourou Chimene Etonga Anoudem Komi Séraphin Adjoh 《Journal of Acute Disease》 2023年第5期186-191,共6页
Objective:To describe the strategies and outcomes of mechanical ventilation in a poorly equipped facility.Methods:This retrospective descriptive study included patients with COVID-19 who were admitted to the intensive... Objective:To describe the strategies and outcomes of mechanical ventilation in a poorly equipped facility.Methods:This retrospective descriptive study included patients with COVID-19 who were admitted to the intensive care unit(ICU)and mechanically ventilated between September 1,2020,and May 31,2021.Data were collected from medical records and databases.Results:54 Patients aged(62.9±13.3)years were included.Among these cases,79.6%had at least one comorbidity.On admission,all patients had hypoxia.The median peripheral oxygen saturation in room air was 76%(61%,83%).Non-invasive ventilation(NIV)was performed in 75.9%of the patients,and invasive mechanical ventilation(IMV)in 68.5%.IMV was performed on patients due to severe coma(8.1%),failure of standard oxygen therapy(27.0%),and failure of NIV(64.9%).An arterial blood gas test was performed in 14.8%of the patients.NIV failed in 90.2%of cases and succeeded in 9.8%.IMV was successful in 5.4%of cases,vs.94.6%of mortality.The overall mortality rate of patients on ventilation in the ICU was 88.9%.The causes of death included severe respiratory distress syndrome(85.2%),multiple organ failure(14.8%),and pulmonary embolism(13.0%).Conclusions:The ventilation management of COVID-19 patients in the ICU with NIV and IMV in a scarce resource setting is associated with a high mortality rate.Shortcomings are identified in ventilation strategies,protocols,and monitoring.Required improvements were also proposed. 展开更多
关键词 Coronavirus disease 2019 Intensive care unit Hy-poxia Invasive ventilation Non-invasive ventilation Arterial blood gas
下载PDF
Causes of Odor in Kitchens,Bathrooms,and Toilets of Multi-story Residential Apartments with Natural Ventilation
7
作者 Alex A.Volinsky 《Journal of Civil Engineering and Architecture》 2023年第3期135-138,共4页
The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in othe... The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities. 展开更多
关键词 ventilation ventilation fan sewage gas check air valve health safety public health
下载PDF
Use of inflammatory markers as predictor for mechanical ventilation in COVID-19 patients with stagesⅢb-Ⅴchronic kidney disease?
8
作者 Harinivaas Shanmugavel Geetha Sushmita Prabhu +5 位作者 Abinesh Sekar Maya Gogtay Yuvaraj Singh Ajay K Mishra George M Abraham Suzanne Martin 《World Journal of Virology》 2023年第5期286-295,共10页
BACKGROUND Studies have shown elevated C-reactive protein(CRP)to predict mechanical ventilation(MV)in patients with coronavirus disease 2019(COVID-19).Its utility is unknown in patients with chronic kidney disease(CKD... BACKGROUND Studies have shown elevated C-reactive protein(CRP)to predict mechanical ventilation(MV)in patients with coronavirus disease 2019(COVID-19).Its utility is unknown in patients with chronic kidney disease(CKD),who have elevated baseline CRP levels due to chronic inflammation and reduced renal clearance.AIM To assess whether an association exists between elevated inflammatory markers and MV rate in patients with stagesⅢb-ⅤCKD and COVID-19.METHODS We conducted a retrospective cohort study on patients with COVID-19 and stagesⅢb-ⅤCKD.The primary outcome was the rate of invasive MV,the rate of noninvasive MV,and the rate of no MV.Statistical analyses used unpaired t-test for continuous variables and chi-square analysis for categorical variables.Cutoffs for variables were CRP:100 mg/L,ferritin:530 ng/mL,D-dimer:0.5 mg/L,and lactate dehydrogenase(LDH):590 U/L.RESULTS 290 were screened,and 118 met the inclusion criteria.CRP,D-dimer,and ferritin were significantly different among the three groups.On univariate analysis for invasive MV(IMV),CRP had an odds ratio(OR)-5.44;ferritin,OR-2.8;LDH,OR-7.7;D-dimer,OR-3.9,(P<0.05).The admission CRP level had an area under curve-receiver operator characteristic(AUROC):0.747 for the IMV group(sensitivity-80.8%,specificity-50%)and 0.663 for the non-IMV(NIMV)group(area under the curve,sensitivity-69.2%,specificity-53%).CONCLUSION Our results demonstrate a positive correlation between CRP,ferritin,and D-dimer levels and MV and NIMV rates in CKD patients.The AUROC demonstrates a good sensitivity for CRP levels in detecting the need for MV in patients with stagesⅢb-ⅤCKD.This may be because of the greater magnitude of increased inflammation due to COVID-19 itself compared with increased inflammation and reduced clearance due to CKD alone. 展开更多
关键词 Coronavirus disease 2019 Chronic kidney disease Inflammatory markers C-reactive protein Invasive mechanical ventilation Non-invasive mechanical ventilation
下载PDF
Effect of different ventilation methods combined with pulmonary surfactant on neonatal acute respiratory distress syndrome 被引量:1
9
作者 Qing Qing Ping Zha +1 位作者 Li-Ying Dai Yang Wang 《World Journal of Clinical Cases》 SCIE 2023年第25期5878-5886,共9页
BACKGROUND Acute respiratory distress syndrome precipitates is widespread pulmonary injury in impacted individuals,the neonatal respiratory distress syndrome(NRDS),primarily observed in preterm infants,represents a pr... BACKGROUND Acute respiratory distress syndrome precipitates is widespread pulmonary injury in impacted individuals,the neonatal respiratory distress syndrome(NRDS),primarily observed in preterm infants,represents a prevalent critical condition in neonatal clinical settings.AIM To investigate the clinical efficacy of various ventilation strategies combined with pulmonary surfactant(PS)therapy in the treatment of NRDS.METHODS A total of 20 neonates diagnosed with respiratory distress syndrome,admitted between May 2021 and June 2022,were randomly assigned to either a research group or a control group.Neonates in the research group received treatment involving high-frequency oscillatory ventilation(HFOV)in conjunction with PS.In contrast,neonates in the control group were administered either controlled mechanical ventilation or synchronous intermittent mandatory ventilation,combined with PS.Arterial blood samples from the neonates in both groups were collected before treatment,as well as 6 h,12 h,24 h,and 48 h post-treatment.These samples underwent blood gas analysis,with measurements taken for pH value,partial pressures of oxygen(O_(2))and carbon dioxide.Concurrently,data was collected on the duration of ventilator use,length of hospitalization time,O_(2) treatment time,treatment outcomes,and complications of the ventilator.RESULTS From 6-48 h post-treatment,both groups demonstrated significant improvements in arterial blood pH and oxygen partial pressure,along with a significant decrease in carbon dioxide partial pressure compared to pre-treatment values(P<0.05).Although these changes progressed over time,there were no significant differences between the two groups(P>0.05).However,the research group had significantly lower X-ray scores,shorter hospitalization time,and less time on O_(2) therapy compared to the control group(P<0.05).Mortality rates were similar between the two groups(P>0.05),but the research group had a significantly lower incidence of complications(P<0.05).CONCLUSION The integration of HFOV combine with PS has proven to effectively expedite the treatment duration,decrease the occurrence of complications,and secure the therapeutic efficacy in managing NRDS. 展开更多
关键词 Neonatal respiratory distress syndrome Pulmonary surfactant Mechanical ventilation Respiratory distress syndrome Acute respiratory distress syndrome
下载PDF
Ultra-broadband acoustic ventilation barrier based on multi-cavity resonators
10
作者 许雨薇 管义钧 +4 位作者 吴成昊 葛勇 司乔瑞 袁寿其 孙宏祥 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第12期397-403,共7页
The numerical simulations and experimental results of an ultra-broadband acoustic ventilation barrier composed of periodic unit cells are reported in this paper.Based on multiple mechanisms,including sound absorption ... The numerical simulations and experimental results of an ultra-broadband acoustic ventilation barrier composed of periodic unit cells are reported in this paper.Based on multiple mechanisms,including sound absorption by eigenmodes of the unit cell and sound reflection by a plate structure on upper surface of the unit cell,a single-layer ventilation barrier with broadband sound reduction is designed,and its working bandwidth can reach about 1560 Hz.The experimental results accord well with the simulation results.Furthermore,two types of three-layer ventilation barriers are designed and demonstrated by using the unit cells with different values of a(the length of the hollow square region)and w(the width of the channel between the adjacent cavities),and the bandwidths of both ventilation barriers can increase to 3160 Hz and 3230 Hz,respectively.The designed barrier structures have the advantages of ultra-broadband sound reduction and ventilation,which paves the way to designing high-performance ventilation barriers for the applications in environmental protection and architectural acoustics. 展开更多
关键词 acoustic metamaterials ultra-broadband sound reduction acoustic barrier ventilation
原文传递
Optimization of a Solar Chimney with a Horizontal Absorber for Building Ventilation:A Case Study
11
作者 El Hadji I Cisse Baye Alioune Ndiogou +2 位作者 Soumaïla Tigampo Ababacar Thiam DorothéAzilinon 《Fluid Dynamics & Materials Processing》 EI 2023年第4期901-910,共10页
A study is conducted to optimize the geometry of a solar chimney equipped with a horizontal absorber in order to improve its performances in relation to the provision of ventilation.The problem is tackled through nume... A study is conducted to optimize the geometry of a solar chimney equipped with a horizontal absorber in order to improve its performances in relation to the provision of ventilation.The problem is tackled through numerical solution of the governing equations for mass,momentum and energy in their complete three-dimensional and unsteady formulation.The numerical framework also includes a turbulence model(k-ε)and a radiant heat transfer(DO)model.Moreover,a Multi-Objective Genetic Algorithm(MOGA)is employed to derive the optimal configuration of the considered solar chimney.It is shown that an air velocity of 0.2 m/s can be obtained.This value is the minimum allowed air velocity according to the ASHRAE’s(American Society of Heating,Refrigerating and Air-Conditioning Engineers)adaptive comfort approach. 展开更多
关键词 Natural ventilation adaptative comfort solar chimney FLUENT MOGA
下载PDF
Wind-Thermal Environmental Characteristic of Multi-Variable Passive Enhanced Natural Ventilation System for High and Large Space Building
12
作者 Lin Liu Haoran Huang +2 位作者 Chenghe Wu Liru Liu Jing Tian 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第5期34-51,共18页
Natural ventilation effects in high and large space buildings of tropical areas greatlya ffect the air conditioning energy consumption.Aiming at nearly zero energy building design,thisp aper mainly contributes to prov... Natural ventilation effects in high and large space buildings of tropical areas greatlya ffect the air conditioning energy consumption.Aiming at nearly zero energy building design,thisp aper mainly contributes to provide theoretical basis and reference for thermal comfortable air conditioning system design of high and large space buildings.Taking a theatre in Hainan as study object,a newly composite enhanced natural ventilation system is proposed by integrating theu nderground tunnel-based earth to air heat exchange system and the solar chimney.Ventilationq uantity,air velocity and air temperature field,human vertical temperature gradient differenceu nder24simulation working conditions are considered and analyzed by using ANSYS Fluent.Fort he underground tunnel,results show that Group Two with double underground tunnels and side airs upply location shows its advantages in cooling effects and air supply uniformity.Then for the solar chimney,results show that the solar radiation intensity contributes to larger difference int ransmission power and leads to different cooling effects.On the whole,the system under workingc ondition No.7with120m long,side air supply,double underground tunnel and20m high,1mw ide,0.6°absorber plate angle solar chimney shows its priority in better comprehensive performance. 展开更多
关键词 natural ventilation solar chimney earth to air heat exchange system energyc onservation thermal environment
下载PDF
Effects of ultrasound monitoring of gastric residual volume on feeding complications,caloric intake and prognosis of patients with severe mechanical ventilation
13
作者 Xiao-Yan Xu Hui-Ping Xue +2 位作者 Ming-Jun Yuan You-Rong Jin Chun-Xia Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第8期1719-1727,共9页
BACKGROUND Monitoring of gastric residual is an important approach for assessing gastric emptying in patients with mechanical ventilation.By monitoring gastric contents,the enteral nutrition scheme can be adjusted in ... BACKGROUND Monitoring of gastric residual is an important approach for assessing gastric emptying in patients with mechanical ventilation.By monitoring gastric contents,the enteral nutrition scheme can be adjusted in time to ensure feeding safety.AIM To investigate the effects of ultrasound monitoring on the incidence of feeding complications,daily caloric intake and prognosis of patients with severe mechanical ventilation.To analyze the clinical significance of ultrasound monitoring of gastric residual volume(GRV)up to 250 mL to provide a theoretical basis for clinical practice.METHODS Patients admitted to the department of emergency medicine of the Affiliated Hospital of Nantong University from January 2018 to June 2022 who received invasive mechanical ventilation and continuous enteral nutrition support within 24-48 h after admission were enrolled in this study.Medical records for patients within 7 d of hospitalization were retrospectively analyzed to compare the incidence of feeding complications,daily caloric intake and clinical prognosis between patients with gastric residual≥250 mL and<250 mL,as monitored by ultrasound on the third day.RESULTS A total of 513 patients were enrolled in this study.Incidences of abdominal distension,diarrhea,and vomiting in the<250 mL and≥250 mL groups were:18.4%vs 21.0%,23.9%vs 32.3%and 4.0%vs 6.5%,respectively;mortality rates were 20.8%vs 22.65%;mechanical ventilation durations were 18.30 d vs 17.56 d while lengths of stay in the intensive care units(ICU)were 19.87 d vs 19.19±5.19 d.Differences in the above factors between groups were not significant.Gastric residual≥250 mL was not an independent risk factor for death and prolonged ICU stay.However,target feeding time of patients in the≥250 mL group was longer than that of patients in the≥250 mL group,and caloric intake(22.0,23.6,24.8,25.3 kcal/kg/d)for patients in the≥250 mL group from the 4^(th) day to the 7^(th) day of hospitalization was lower than that of patients in the≥250 mL group(23.2,24.8,25.7,25.8 kcal/kg/d).On the 4^(th) day(Z=4.324,P=0.013),on the 5^(th) day(Z=3.376,P=0.033),while on the 6^(th) day(Z=3.098,P=0.04),the differences were statistically significant.CONCLUSION The use of ultrasound to monitor GRV and undertaking clinical interventions when the monitoring value is≥250 mL has no significant effects on incidences of feeding complications and clinical prognostic outcomes,however,it significantly prolongs the time to reach target feeding,reduces the daily intake of calories during ICU hospitalization,and increases the risk of insufficient nutrition of patients.The accuracy and necessity of monitoring gastric remnants and monitoring frequencies should be investigated further. 展开更多
关键词 Gastric residual monitoring Mechanical ventilation VOMIT Caloric intake PROGNOSIS
下载PDF
A Comparison of Arterial Oxygenation between 60% O2 CPAP and 100% O2 CPAP during One-Lung Ventilation: A Prospective Randomized Controlled Study
14
作者 Yuko Yamada Kumiko Tanabe +1 位作者 Kiyoshi Nagase Hiroki Iida 《Open Journal of Anesthesiology》 2023年第1期1-14,共14页
Background: One-lung ventilation (OLV) is generally adopted for thoracic surgery. The systemic application of a high fraction of inspiratory oxygen (F<sub>1</sub>O<sub>2</sub>) and continuous p... Background: One-lung ventilation (OLV) is generally adopted for thoracic surgery. The systemic application of a high fraction of inspiratory oxygen (F<sub>1</sub>O<sub>2</sub>) and continuous positive airway pressure (CPAP) to the non-ventilated lung is useful for preventing arterial oxygen desaturation. The adverse effects of elevated F<sub>1</sub>O<sub>2</sub> include oxidative lung injury, resorption atelectasis and coronary and peripheral vasoconstriction. It is preferable to avoid hyperoxemia in patients with complications such as chronic obstructive pulmonary disease, idiopathic pneumonia, and bleomycin-treated lungs. We aimed to determine whether the application of 60% O<sub>2</sub> CPAP to the non-ventilated lung is sufficient to provide adequate oxygenation with 60% O<sub>2</sub> to the ventilated lung. Methods: A total of 70 patients scheduled to receive elective thoracic surgery requiring OLV were recruited. Left double-lumen tubes were applicable in all surgeries. Patients were randomly allocated to one of two groups, to receive either 60% O<sub>2</sub> CPAP (60% CPAP group, n = 35), or 100% O<sub>2</sub> CPAP (100% CPAP group, n = 35) at a setting of 2 - 3 cmH<sub>2</sub>O, applied to the non-ventilated lung. Arterial blood gas analyses were obtained at the following stages: RA, spontaneous breathing under room air (RA);TLV, during total lung ventilation (TLV) prior to the initiation of OLV;T5, 5 min after the initiation of OLV;T15, 15 min after the initiation of OLV;T30, 30 min after the initiation of OLV. Results: The PaO<sub>2</sub> value in 60% CPAP group vs. 100% CPAP group at each measurement were as follows: RA (mean [standard deviation: SD], 89.7 [8.2] mmHg vs. 85.8 [11.9] mmHg);TLV (277.9 [52.9] mmHg vs. 269.2 [44.0] mmHg);T5 (191.4 [67.9] mmHg vs. 192.3 [66.0] mmHg);T15 (143.2 [67.3] mmHg vs. 154.7 [60.8] mmHg) and T30 (95.6 [32.0] mmHg vs. 112.5 [36.5] mmHg), respectively. Among the five measurement points, T30 was the only time point at which the 100% CPAP group showed a significantly greater PaO<sub>2</sub> value than the 60% CPAP group (p = 0.0495). The SaO<sub>2</sub> at T30 in the 100% CPAP group (97.4 [2.0]%) was also significantly greater than that in the 60% CPAP group (96.3 [2.2]%, p = 0.039). No differences were found between the groups regarding changes to the overall PaO<sub>2</sub> values (p = 0.44) and SaO<sub>2</sub> values (p = 0.23) during the study period. Conclusions: Oxygenation could be safely maintained in relatively healthy patients with 60% O<sub>2</sub> OLV and 60% O<sub>2</sub> CPAP. The application of 60% O<sub>2</sub> CPAP during OLV for patients who are not suited to exposure to high F<sub>1</sub>O<sub>2</sub> may be an alternative form of respiratory management. 展开更多
关键词 CPAP Double-Lumen Tube Hyperoxemia HYPOXEMIA One-Lung ventilation
下载PDF
Application of ventilation management programs for improved mine safety 被引量:6
15
作者 De Souza Euler 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2017年第4期647-650,共4页
The purpose of ventilation management systems is to ensure the health and safety of underground workers by creating and incorporating structured plans, procedures and processes on the day-to-day operations of the mine... The purpose of ventilation management systems is to ensure the health and safety of underground workers by creating and incorporating structured plans, procedures and processes on the day-to-day operations of the mine ventilation system. The application of ventilation management programs consists of audit, verification, and corrective action procedures to:(1) ensure adherence to regulatory standards,or to(2) return to compliance and safety standards when an upset condition arises. This paper describes how a ventilation management program can be developed and implemented to ensure regulation compliance, to increase safety, to improve operational efficiency and to reduce the operating costs of an operating mine. Two case applications are presented in this paper. The first case is presented to demonstrate use of a ventilation management program in response to a site inspection and audit, with follow-up application of corrective actions. The second case application describes how air quality conditions has been substantially improved with the development and implementation of a ventilation management program for an operating underground hard rock mine. 展开更多
关键词 Mine ventilation ventilation management Air quality ventilation efficiency
下载PDF
Treatment of a large area perioral viral herpes infection following noninvasive ventilation:A case report
16
作者 A-Mao Tang Jia-Ying Xu +1 位作者 Rong Wang Yi-Min Li 《World Journal of Clinical Cases》 SCIE 2023年第8期1857-1861,共5页
BACKGROUND Alphaherpesvirus belongs to the Herpesviridae family and has large,monopartite double-stranded linear DNA.It mainly infects the skin,mucosa,and nerves,and can affect various hosts,including humans and other... BACKGROUND Alphaherpesvirus belongs to the Herpesviridae family and has large,monopartite double-stranded linear DNA.It mainly infects the skin,mucosa,and nerves,and can affect various hosts,including humans and other animals.Here,we present a case of a patient seen by the gastroenterology department at our hospital who experienced an oral and perioral herpes infection following treatment with a ven-tilator.The patient was treated with oral and topical antiviral drugs,furacilin,oral and topical antibiotics,local epinephrine injection,topical thrombin powder,and nutritional and supportive care.A wet wound healing approach was also implemented with good response.CASE SUMMARY A 73-year-old woman presented to the hospital with a chief complaint of"abdominal pain for 3 d with dizziness for 2 d."She was admitted to the intensive care unit for septic shock and spontaneous peritonitis secondary to cirrhosis and was given antiinflammatory and symptomatic supportive treatment.A ventilator was used to assist breathing for acute respiratory distress syndrome,which developed during her admission.A large area of herpes infection appeared in the perioral region 2 d following noninvasive ventilation.The patient was transferred to the gastroenterology department,at which time she had a body temperature of 37.8 C and a respiratory rate of 18/min.The patient's con-sciousness was intact,and she no longer had abdominal pain or distension,chest tightness,or asthma.At this point,the infected perioral region changed in appearance and was now accompanied by local bleeding with crusting of blood at the wounds.The surface area of the wounds measured approximately 10 cm×10 cm.A cluster blisters appeared on the patient’s right neck,and ulcers developed in her mouth.On a subjective numerical pain scale,the patient reported a pain level of 2.Overall,her diagnoses other than the oral and perioral herpes infection included:(1)Septic shock;(2)spontaneous peritonitis;(3)abdominal infection;(4)decompensated cirrhosis;and(5)hypoproteinemia.Dermatology was consulted regarding the treatment of the patient’s wounds;they suggested treatment with oral antiviral drugs,an intramuscular injection of nutritious nerve drugs,and the application of topical penciclovir and mupirocin around the lips.Stomatology was also consulted and suggested the use of nitrocilin in a local wet application around the lips.CONCLUSION Through multidisciplinary consultation,the patient’s oral and perioral herpes infection was successfully treated with the following combined approach:(1)Application of topical antviral and antibiotic treatments;(2)keeping the wound moist with a wet wound healing strategy;(3)systemic use of oral antiviral drugs;and(4)symptomatic and nutritional supportive care.The patient was discharged from the hospital after successful wound healing. 展开更多
关键词 VENTILATOR Viral herpes Nursing care Case report
下载PDF
Application of fiberoptic bronchscopy in patients with acute exacerbations of chronic obstructive pulmonary disease during sequential weaning of invasive-noninvasive mechanical ventilation 被引量:17
17
作者 Rong-rong Song Yan-ping Qiu +1 位作者 Yong-ju Chen Yong Ji 《World Journal of Emergency Medicine》 CAS 2012年第1期29-34,共6页
BACKGROUND:Early withdrawal of invasive mechanical ventilation(IMV) followed by noninvasive MV(NIMV) is a new strategy for changing modes of treatment in patients with acute exacerbations of chronic obstructive pulmon... BACKGROUND:Early withdrawal of invasive mechanical ventilation(IMV) followed by noninvasive MV(NIMV) is a new strategy for changing modes of treatment in patients with acute exacerbations of chronic obstructive pulmonary disease(AECOPD) with acute respiratory failure(ARF).Using pulmonary infection control window(PIC window) as the switch point for transferring from invasive to noninvasive MV,the time for early extubation can be more accurately judged,and therapy efficacy can be improved.This study aimed to prospectively investigate the clinical effectiveness of fiberoptic bronchscopy(FOB) in patients with AECOPD during sequential weaning of invasive-noninvasive MV.METHODS:Since July 2006 to January 2011,106 AECOPD patients with ARF were treated with comprehensive medication and IMV after hospitalization.Patients were randomly divided into two groups according to whether fiberoptic bronchoscope is used(group A,n=54) or not(group B,n=52) during sequential weaning from invasive to noninvasive MV.In group A,for sputum suction and bronchoalveolar lavage(BAL),a fiberoptic bronchoscope was put into the airway from the outside of an endotracheal tube,which was accompanied with uninterrupted use of a ventilator.After achieving PIC window,patients of both groups changed to NIMV mode,and weaned from ventilation.The following listed indices were used to compare between the groups after treatment:1) the occurrence time of PIC,the duration of MV,the length of ICU stay,the success rate of weaning from MV for the first time,the rate of reventilatJon and the occurrence rate of ventilator-associated pneumonia(VAP);2) the convenience and safety of FOB manipulation.The results were compared using Student's f test and the Chi-square test.RESULTS:The occurrence time of PIC was(5.01 ±1.49) d,(5.87±1.87) d in groups A and B,respectively(P<0.05);the duration of MV was(6.98±1.84) d,(8.69±2.41) d in groups A and B,respectively(P<0.01);the length of ICU stay was(9.25±1.84) d,(11.10±2.63) d in groups A and B,respectively(P<0.01);the success rate of weaning for the first time was 96.30%,76.92%in groups A and B,respectively(P<0.01);the rate of reventilation was 5.56%,19.23%in groups A and B,respectively(P<0.05);and the occurrence rate of VAP was 3.70%,23.07%in groups A and B,respectively(P<0.01).Moreover,it was easy and safe to manipulate FOB,and no side effect was observed.CONCLUSIONS:The application of FOB in patients with AECOPD during sequential weaning of invasive-noninvasive MV is effective in ICU.It can decrease the duration of MV and the length of ICU stay,increase the success rate from weaning MV for the first time,reduce the rate of reventilation and the occurrence rate of VAP.In addition,such a method is convenient and safe in patients of this kind. 展开更多
关键词 Acute exacerbations of chronic obstructive pulmonary disease Acute respiratory failure Mechanical ventilation Sequential weaning of invasive-noninvasive ventilation Fiberoptic bronchscopy Bronchoalveolar lavage Pulmonary infection control window Side effect Success rate
下载PDF
Optimized model-based control of main mine ventilation air flows with minimized energy consumption 被引量:4
18
作者 S.Sjostrom E.Klintenas +1 位作者 P.Johansson J.Nyqvist 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2020年第4期533-539,共7页
In early 2018,the Boliden Garpenberg operation implemented an optimized control strategy as an addition to the existing ventilation on demand system.The purpose of the strategy is to further minimize energy use for ma... In early 2018,the Boliden Garpenberg operation implemented an optimized control strategy as an addition to the existing ventilation on demand system.The purpose of the strategy is to further minimize energy use for main and booster fans,whilst also fulfilling airflow setpoints without violating constraints such as min/max differential pressure over fans and interaction of air between areas in mines.Using air flow measurements and a dynamical model of the ventilation system,a mine-wide coordination control of fans can be carried out.The numerical model is data driven and derived from historical operational data or step changes experiments.This makes both initial deployment and lifetime model maintenance,as the mine evolves,a comparably easy operation.The control has been proven to operate in a stable manner over long periods without having to re-calibrate the model.Results prove a 40%decrease in energy use for the fans involved and a greater controllability of air flow.Moreover,a 15%decrease of the total air flow into the mine will give additional proportional heating savings during winter periods.All in all,the multivariable controller shows a correlation between production in the mine and the ventilation system performance superior to all of its predecessors. 展开更多
关键词 Mine ventilation ventilation on demand Optimized model-based control Minimized energy consumption Advanced process control
下载PDF
Adaptive Wall-Based Attachment Ventilation:A Comparative Study on Its Effectiveness in Airborne Infection Isolation Rooms with Negative Pressure 被引量:2
19
作者 Ying Zhang Ou Han +4 位作者 Angui Li Li’an Hou Thomas Olofsson Linhua Zhang Wenjun Lei 《Engineering》 SCIE EI 2022年第1期130-137,共8页
The transmission of coronavirus disease 2019(COVID-19)has presented challenges for the control of the indoor environment of isolation wards.Scientific air distribution design and operation management are crucial to en... The transmission of coronavirus disease 2019(COVID-19)has presented challenges for the control of the indoor environment of isolation wards.Scientific air distribution design and operation management are crucial to ensure the environmental safety of medical staff.This paper proposes the application of adaptive wall-based attachment ventilation and evaluates this air supply mode based on contaminants dispersion,removal efficiency,thermal comfort,and operating expense.Adaptive wall-based attachment ventilation provides a direct supply of fresh air to the occupied zone.In comparison with a ceiling air supply or upper sidewall air supply,adaptive wall-based attachment ventilation results in a 15%–47%lower average concentration of contaminants,for a continual release of contaminants at the same air changes per hour(ACH;10 h^(-1)).The contaminant removal efficiency of complete mixing ventilation cannot exceed 1.For adaptive wall-based attachment ventilation,the contaminant removal efficiency is an exponential function of the ACH.Compared with the ceiling air supply mode or upper sidewall air supply mode,adaptive wall-based attachment ventilation achieves a similar thermal comfort level(predicted mean vote(PMV)of0.1–0.4;draught rate of 2.5%–6.7%)and a similar performance in removing contaminants,but has a lower ACH and uses less energy. 展开更多
关键词 ventilation efficiency Air change rate COVID-19 Attachment ventilation Air distribution Isolation ward
下载PDF
Clinical outcomes of moderate to severe COVID-19 patients receiving invasive vs. non-invasive ventilation 被引量:1
20
作者 Zubia Jamil Samreen Khalid +2 位作者 Shahid Mumtaz Abbasi Yasir Waheed Jamal Ahmed 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2021年第4期176-182,共7页
Objective:To evaluate the in-hospital outcome of moderate to severe COVID-19 patients admitted in High Dependency Unit(HDU)in relation to invasive vs.non-invasive mode of ventilation.Methods:In this study,the patients... Objective:To evaluate the in-hospital outcome of moderate to severe COVID-19 patients admitted in High Dependency Unit(HDU)in relation to invasive vs.non-invasive mode of ventilation.Methods:In this study,the patients required either non-invasive[oxygen≤10 L/min or>10 L/min through mask or nasal prongs,rebreather masks and bilevel positive airway pressure(BiPAP)]or invasive ventilation.For analysis of 30-day in hospital mortality in relation to use of different modes of oxygen,Kaplan Meier and log rank analyses were used.In the end,independent predictors of survival were determined by Cox regression analysis.Results:Invasive ventilation was required by 15.1%patients while 84.9%patients needed non-invasive ventilation.Patients with evidence of thromboembolism,high inflammatory markers and hypoxemia mainly required invasive ventilation.The 30-day in hospital mortality was 72.7%for the invasive group and 12.9%for the non-invasive group(1.8%oxygen<10 L/min,0.9%oxygen>10 L/min,3.6%rebreather mask and 4.5%BiPAP).The median time from hospital admission to outcome was 7 days for the invasive group and 18 days for the non-invasive group(P<0.05).Age,presence of co-morbidities,number of days requiring oxygen,rebreather,BiPAP and invasive ventilation were independent predictors of outcome.Conclusions:Invasive mechanical ventilation is associated with adverse outcomes possibly due to ventilator associated lung injury.Thus,protective non-invasive ventilation remains the necessary and safe treatment for severely hypoxic COVID-19 patients. 展开更多
关键词 COVID-19 SARS-CoV-2 Non-invasive ventilation Respiratory insufficiency HYPOXIA Mechanical ventilation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部