Program for Solar Water Heating Systems Based on the F-Chart Method
1
作者 Felix do Rego Barros Adriano Gatto Lemos +1 位作者 Sildenir Alves Ribeiro Manoel Antonio da Fonseca Costa Filho 《Journal of Mechanics Engineering and Automation》 2014年第9期752-762,共11页
This paper aims at presenting an application developed in Java for optimizing the design of centralized solar water heating systems with forced circulation, based on the f-chart method. The program uses data from the ... This paper aims at presenting an application developed in Java for optimizing the design of centralized solar water heating systems with forced circulation, based on the f-chart method. The program uses data from the Brazilian Solar Atlas, performance data of flat plate collectors and thermal reservoirs from the standardized tests run within the Brazilian Labeling Program, and values of water consumption of appliances defined by the ABNT. The program finds the inclination of the collector that maximizes the annual solar fraction, or for the winter, and enables the use of arrays in series and parallel collectors. From the investment costs and O & M (operations and maintenance) of solar heating systems, the program carries out economical analysis using classical parameters as net present value, discounted payback and internal rate of return. The program was validated through examples from the book of Duffle & Beckman and also by comparison with the results from a project developed at UFRGS, having obtained good agreement. 展开更多
关键词 Solar water heating f-chart method solar collectors.
下载PDF
Simulating the Performance of Solar Water Heating Systems
2
作者 Pablo A. Lisboa Manoei A. Fonseca-Costa 《Journal of Energy and Power Engineering》 2014年第4期636-645,共10页
This paper presents a software for simulating the thermal performance of solar water heating systems. The implemented model computes the energy balance in the hot water storage tank in each time step along a simulatio... This paper presents a software for simulating the thermal performance of solar water heating systems. The implemented model computes the energy balance in the hot water storage tank in each time step along a simulation interval. Its input data are values from a typical meteorological year of a chosen location and the hot water load. The system components are the hot water storage tank and the solar collector. Firstly, the validation of the model is presented and then four solar water heating systems are simulated in four different cities along one year. The storage tank water hourly temperatures were obtained for a typical meteorological year and those values were compared with the values obtained by the widespread TRNSYS simulation software. The results obtained from this comparison were satisfactory. 展开更多
关键词 SOFTWARE solar energy thermal simulation water heating.
下载PDF
Numerical Analysis of Phase Change and Container Materials for Thermal Energy Storage in the Storage Tank of Solar Water Heating System 被引量:1
3
作者 SINGH Shailendra ANAND Abhishek +1 位作者 SHUKLA Amritanshu SHARMA Atul 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第2期408-421,共14页
This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Ca... This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Canbazoglu et al.The model is explained by five fundamental equations for the calculation of various parameters like the effectiveness of PCMs,the mass of hot water,total heat content,and duration of charging.This study simulated eleven PCMs to analyze their effectiveness like Sodium hydrogen phosphate dodecahydrate(SHPD),OM 37,N-Eicosane(NE),Lauric acid(LA),Paraffin wax(PW),OM 48,Paraffin wax C_(20-33)(PW-C20-33),Sodium acetate trihydrate(SAT),Palmitic acid(PA),Myristic acid(MA),and Stearic acid(SA).Among all PCMs,the SHPD has found the highest value of effectiveness factor of 3.27.So,it is the most recommended PCM for the storage tank of the SWH system.The study also includes the melt fraction analysis of all enumerated PCMs corresponding to container materials of stainless steel,glass,aluminum mixed,tin,aluminum,and copper.This melt fraction analysis is performed by making a coding program in the FORTRAN programming language.Through the analysis,copper container material is found to have high melting rate for all PCMs so it is superior to other container materials. 展开更多
关键词 theoretical model solar water heating system phase change material effectiveness factor melt fraction
原文传递
Potential application of a novel building-integrated solar facade water heating system in a subtropical climate:A case study for school canteen
4
作者 Wenjie Liu Xinwen Liu +3 位作者 Chongchao Pan Chunying Li Woonming Lau Yuanli Lyu 《Building Simulation》 SCIE EI CSCD 2023年第10期1987-2004,共18页
The design and potential application analysis of the novel solar-absorbing integrated facade module and its corresponding building-integrated solar facade water heating system are presented in this study.Compared with... The design and potential application analysis of the novel solar-absorbing integrated facade module and its corresponding building-integrated solar facade water heating system are presented in this study.Compared with the conventional building envelope,the main novities of the proposed facade module lie in its contributions towards the supplied water preheating to loads and the internal heat gain reduction.Besides,the proposed building-integrated solar facade water heating system broadens the combination modes of the solar thermal system and the building envelope.A dynamic model is introduced first for system design and performance prediction.To evaluate the energy-saving potential and feasibility of the implementation of the proposed facade module,this paper carried out a suitable case study by replacing the conventional facade module in the ongoing retrofitting project of a kitchen,part of the canteen of a graduate school.The detailed thermal performances of three system design options are compared in the typical winter and summer weeks and throughout the year,and then,with the preferred system design,the economic,energy,and environmental effects of the proposed system are evaluated.It was found that the system with a high flow rate of the circulating water is suggested.The annual electricity saved reaches 4175.3 kWh with yearly average thermal efficiency at 46.9%,and its corresponding cost payback time,energy payback time,and greenhouse gas payback time are 3.8,1.7,1.7 years,respectively.This study confirms the feasibility and long-term benefits of the proposed building-integrated solar facade water heating system in buildings. 展开更多
关键词 solar thermal utilization building-integrated solar water heating system novel prefabricated facade module life cycle assessment building retrofitting
原文传递
Practice and analysis of recycling non-drinking water from air-condition and reverse-osmosis system into rainwater collection system 被引量:2
5
作者 王小红 邵煜然 王靖华 《Journal of Southeast University(English Edition)》 EI CAS 2014年第2期169-174,共6页
This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilizat... This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period. 展开更多
关键词 rainwater collection heating ventilation and air conditioning condensation water precipitation analysis reverse-osmosis concentrated water
下载PDF
Life cycle cost analysis of new FRP based solar parabolic trough collector hot water generation system 被引量:1
6
作者 A. VALAN ARASU T. SORNAKUMAR 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第3期416-422,共7页
Parabolic trough collectors (PTCs) are employed for a variety of applications including steam generation and hot water generation. This paper deals with the experimental results and an economic analysis of a new fib... Parabolic trough collectors (PTCs) are employed for a variety of applications including steam generation and hot water generation. This paper deals with the experimental results and an economic analysis of a new fibre reinforced plastic (FRP) based solar PTC with an embedded electronic controlled tracking system designed and developed for hot water generation in a restaurant in Madurai, India. The new collector performance has been tested according to ASHRAE Standard 93 (1986). The performance of a new PTC hot water generation system with a well mixed hot water storage tank is investigated by a series of extensive tests over ten months period. The average maximum storage tank water temperature observed was 74.91℃, when no energy is withdrawn from the tank to the load during the collection period. The total cost of the new economic FRP based solar PTC for hot water generation with an embedded electronic controlled tracking system is Rs. 25000 (US$ 573) only. In the present work, life cycle savings (LCS) method is employed for a detailed economic analysis of the PTC system. A computer program is used as a tool for the economic analysis. The present worth of life cycle solar savings is evaluated for the new solar PTC hot water generation system that replaces an existing electric water heating system in the restaurant and attains a value of Rs. 23171.66 after 15 years, which is a significant saving. The LCS method and the MATLAB computer simulation program presented in this paper can be used to estimate the LCS of other renewable energy systems. 展开更多
关键词 Economic analysis Life cycle savings Life cycle cost (LCS) Parabolic trough collector (PTC) Solar water heating system (SWHS)
下载PDF
Energy Efficient Air Conditioning System Using Geothermal Cooling-Solar Heating in Gujarat, India 被引量:1
7
作者 Sneha Shahare T. Harinarayana 《Journal of Power and Energy Engineering》 2016年第1期57-71,共15页
It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, t... It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger. 展开更多
关键词 Energy Efficiency Geothermal Cooling Air Conditioning CFD Thermal Comfort Earth water Heat Exchanger
下载PDF
Heating of Nanosized Liquid Water in High-Intensity Terahertz Pulses
8
作者 黄自谦 杨荣瑶 +1 位作者 蒋维洲 章其林 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第1期36-39,共4页
Non-equilibrium molecular dynamics simulations of liquid water in picosecond high-power terahertz pulses are performed by using a non-polarizable potential model. Numerical results show that the energy absorption of w... Non-equilibrium molecular dynamics simulations of liquid water in picosecond high-power terahertz pulses are performed by using a non-polarizable potential model. Numerical results show that the energy absorption of water molecules exhibits a pronounced resonance with THz pulses in the frequency range of 14-17 THz. With the THz pulse at resonant frequencies, the maximum temperature is about 562 K by heating the water at room temperature. Further investigation indicates that the results are independent of the size of the nanoscale water box. The efficiency of energy transfer by resonant absorption is more than seven times of microwave heating. These studies show promising applications of ultrashort THz pulses. 展开更多
关键词 of on heating of Nanosized Liquid water in High-Intensity Terahertz Pulses THz in is that
原文传递
Overview of China's National Standards for Solar Water Heating
9
作者 JIA Tieying 《China Standardization》 2007年第5期6-11,共6页
Energy supply is one of the major challenges facing China. The rate at which demand is outstripping supply led the Standing Committee of the National People's Congress to pass the Renewable Energy Law of the PRC a... Energy supply is one of the major challenges facing China. The rate at which demand is outstripping supply led the Standing Committee of the National People's Congress to pass the Renewable Energy Law of the PRC at its fourteenth session in February, 2005. The document points out that 'The law is legislated to promote exploitation and utilization of renewable energy, increase the supply of energy sources, improve the structure of energy sources, ensure the security of energy sources, protect the environment, and achieve the sustainable development of economy and society.' 'Renewable energy under the law is non-fossil energy, including wind, solar, water, biomass, geothermal, and ocean energies, etc.' 'The nation determines that the exploitation and utilization of renewable energy takes precedence in the development of energy sources, and propels the establishment and development of the renewable energy market.' 'The Standardization Administrative Department of the State Council should constitute and promulgate the national grid-connection standards for renew- able electricity, and other national technical standards that are related to renewable energy technology and products.' 展开更多
关键词 Overview of China’s National Standards for Solar water heating
下载PDF
Experimental Investigation on Solution Regeneration Performance and Coefficients in Full-Open System for Heat and Water Recovery of Flue Gas
10
作者 WEI Hongyang HUANG Shifang +3 位作者 MA Yuxin CHEN Bo SUN Li ZHANG Xiaosong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第3期1094-1108,共15页
The recovery of heat and water from low-grade flue gas is of considerable importance for energy conservation and environmental preservation.While the full-open absorption heat pump shows promise as a means of achievin... The recovery of heat and water from low-grade flue gas is of considerable importance for energy conservation and environmental preservation.While the full-open absorption heat pump shows promise as a means of achieving heat and water recovery,the lack of research on heat and mass transfer performance of open-type solution evaporation regeneration represents a significant impediment to its design and operation.This paper experimentally investigates the regeneration performance of an open-type spaying tower equipped with ceramic structured packings.Two different regeneration modes are proposed,namely ambient air receiver mode and flue gas receiver mode,to utilize air or low-grade flue gas as a driving source.The impact of different input parameters on the regeneration characteristics,including heat transfer capacity,water removal rate,thermal efficiency,and humidity effectiveness,are demonstrated.The findings indicate that the enhancement of regeneration can be achieved through the increase of solution flow rate,solution temperature,and flue gas flow rate in both regeneration modes.However,high solution concentration and flue gas humidity ratio can weaken water removal rates and reduce thermal efficiency.For the regeneration of CaCl_(2)-H_(2)O with a concentration of55%,flue gas around 200℃with a humidity ratio below 44 g/kg can successfully drive the solution regeneration process.When the solution concentration or flue gas humidity ratio continues to rise,additional energy is necessary for regeneration.Furthermore,the coupled heat and mass transfer coefficients are fitted,which can contribute to the design and optimization of the open-type regenerator. 展开更多
关键词 heat and water recovery solution regeneration flue gas regeneration performance coefficient
原文传递
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
11
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
12
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
下载PDF
Rapid and Continuous Production of LiFePO4/C Nanoparticles in Super Heated Water 被引量:11
13
作者 于文利 赵亚平 饶群力 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2009年第1期171-174,共4页
A rapid and continuous method for production of LiFePO4/C nanoparticles in super heated water is described, wherein soluble starch was used as carbon precursor. The effects of pH, flow rate, temperature, and pressure ... A rapid and continuous method for production of LiFePO4/C nanoparticles in super heated water is described, wherein soluble starch was used as carbon precursor. The effects of pH, flow rate, temperature, and pressure on the formation of LiFePO4/C particles were investigated. Results showed that the pH value was the key factot on the formation of phase pure LiFePO4, which only formed at pH = 7; the LiFePO4/C-occurred as particles with about 70-200 nm size and LiFePO4 was covered by a thin carbon layer; higher flow rate, higher pressure, and lower temperature led to smaller particles of LiFePO4/C. 展开更多
关键词 LiFePO/4C NANOPARTICLE super heated water
下载PDF
Water and heat transport in hilly red soil of southern China:I. Experiment and analysis 被引量:4
14
作者 吕军 黄志珍 韩晓非 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE EI CAS CSCD 2005年第5期331-337,共7页
Studies on coupled transfer of soil moisture and heat have been widely carried out for decades. However, little work has been done on red soils, widespread in southern China. The simultaneous transfer of soil moisture... Studies on coupled transfer of soil moisture and heat have been widely carried out for decades. However, little work has been done on red soils, widespread in southern China. The simultaneous transfer of soil moisture and heat depends on soil physical properties and the climate conditions. Red soil is heavy clay and high content of free iron and aluminum oxide. The climate conditions are characterized by the clear four seasons and the serious seasonal drought. The great annual and diurnal air temperature differences result in significant fluctuation in soil temperature in top layer. The closed and evaporating columns experiments with red soil were conducted to simulate the coupled transfer of soil water and heat under the overlaying and opening fields’ conditions, and to analyze the effects of soil temperature gradient on the water transfer and the effects of initial soil water contents on the transfer of soil water and heat. The closed and evaporating columns were designed similarly with about 18 °C temperatures differences between the top and bottom boundary, except of the upper end closed or exposed to the air, respectively. Results showed that in the closed column, water moved towards the cold end driven by temperature gradient, while the transported water decreased with the increasing initial soil water content until the initial soil water content reached to field capacity equivalent, when almost no changes for the soil moisture profile. In the evaporating column, the net transport of soil water was simultaneously driven by evaporation and temperature gradients, and the drier soil was more influenced by temperature gradient than by evapo- ration. In drier soil, it took a longer time for the temperature to reach equilibrium, because of more net amount of transported water. 展开更多
关键词 Red soil Coupled transfer of water and heat EVAPORATION Initial soil moisture
下载PDF
Coupled Transfer of Water and Heat in Red Soil: Experiment and Numerical Modelling 被引量:4
15
作者 HANXIAOFEI LUJUN 《Pedosphere》 SCIE CAS CSCD 2001年第2期123-130,共8页
Coupled transfer of soil water and heat in closed columns of homogeneous red soil was studied under laboratory conditions. A coupled model was constructed using soil physical theory, empirical equations and experiment... Coupled transfer of soil water and heat in closed columns of homogeneous red soil was studied under laboratory conditions. A coupled model was constructed using soil physical theory, empirical equations and experimental data to predict the coupled transfer. The results show that transport of soil water was affected by temperature gradient, and the largest net water transport was found in the soil column with initial water content of 0.148 m3 m-3. At the same time, temperature changes with the transport of soil water was in a nonlinear shape as heat parameters were function of water content, and the changes of temperature were positively correlated with the net amount of water transported. Numerical modelling results show that the predicted values of temperature distribution were close to the observed values, while the predicted values of water content exhibited limited deviation at both ends of the soil column due to the slight temperature changes at both ends. It was indicated that the model proposed here was applicable. 展开更多
关键词 coupled transfer of water and heat numerical modelling red soil
下载PDF
Effects of biodegradable mulch on soil water and heat conditions,yield and quality of processing tomatoes by drip irrigation 被引量:3
16
作者 JIA Hao WANG Zhenhua +4 位作者 ZHANG Jinzhu LI Wenhao REN Zuoli JIA Zhecheng WANG Qin 《Journal of Arid Land》 SCIE CSCD 2020年第5期819-836,共18页
To combat the problem of residual film pollution and ensure the sustainable development of agriculture in oasis areas,a field experiment was carried out in 2019 at the Wuyi Farm Corps Irrigation Center Test Station in... To combat the problem of residual film pollution and ensure the sustainable development of agriculture in oasis areas,a field experiment was carried out in 2019 at the Wuyi Farm Corps Irrigation Center Test Station in Urumqi,Northwest China.Four types of biodegradable mulches,traditional plastic mulchs and a control group(bare land;referred to as CK)were compared,including a total of six different treatments.Effects of mulching on soil water and heat conditions as well as the yield and quality of processing tomatoes under drip irrigation were examined.In addition,a comparative analysis of economic benefits of biodegradable mulches was performed.Principal component analysis and gray correlation analysis were used to evaluate suitable mulching varieties for planting processing tomatoes under drip irrigation.Our results show that,compared with CK,biodegradable mulches and traditional plastic mulch have a similar effect on retaining soil moisture at the seedling stage but significantly increase soil moisture by 0.5%-1.5%and 1.5%-3.0%in the middle and late growth periods(P<0.050),respectively.The difference in the thermal insulation effect between biodegradable mulch and plastic mulch gradually reduces as the crop grows.Compared with plastic mulch,the average soil temperature at 5-20 cm depth under biodegradable mulches is significantly lowered by 2.04°C-3.52°C and 0.52°C-0.88°C(P<0.050)at the seedling stage and the full growth period,respectively,and the water use efficiency,average fruit yield,and production-investment ratio under biodegradable mulches were reduced by 0.89%-6.63%,3.39%-8.69%,and 0.51%-6.33%(P<0.050),respectively.The comprehensive evaluation analysis suggests that the black oxidized biological double-degradation ecological mulch made from eco-benign plastic is the optimal film type under the study condition.Therefore,from the perspective of sustainable development,biodegradable mulch is a competitive alternative to plastic mulch for large-scale tomato production under drip irrigation in the oasis. 展开更多
关键词 biodegradable plastic mulch processing tomato water use efficiency soil water and heat comprehensive evaluation regional agricultural sustainability XINJIANG
下载PDF
Water and heat transport in hilly red soil of southern China:II. Modeling and simulation 被引量:2
17
作者 吕军 黄志珍 韩晓非 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE EI CAS CSCD 2005年第5期338-345,共8页
Simulation models of heat and water transport have not been rigorously tested for the red soils of southern China. Based on the theory of nonisothermal water-heat coupled transfer, a simulation model, programmed in Vi... Simulation models of heat and water transport have not been rigorously tested for the red soils of southern China. Based on the theory of nonisothermal water-heat coupled transfer, a simulation model, programmed in Visual Basic 6.0, was developed to predict the coupled transfer of water and heat in hilly red soil. A series of soil column experiments for soil water and heat transfer, including soil columns with closed and evaporating top ends, were used to test the simulation model. Results showed that in the closed columns, the temporal and spatial distribution of moisture and heat could be very well predicted by the model, while in the evaporating columns, the simulated soil water contents were somewhat different from the observed ones. In the heat flow equation by Taylor and Lary (1964), the effect of soil water evaporation on the heat flow is not involved, which may be the main reason for the differences between simulated and observed results. The predicted temperatures were not in agreement with the observed one with thermal conductivities calculated by de Vries and Wierenga equations, so that it is suggested that Kh, soil heat conductivity, be multiplied by 8.0 for the first 6.5 h and by 1.2 later on. Sensitivity analysis of soil water and heat coefficients showed that the saturated hydraulic conductivity, KS, and the water diffusivity, D(θ), had great effects on soil water transport; the variation of soil porosity led to the difference of soil thermal properties, and accordingly changed temperature redistribution, which would affect water redistribution. 展开更多
关键词 Red soil Coupled transfer of soil water and heat Simulation model VALIDATION Sensitivity analysis
下载PDF
Different discretization method used in coupled water and heat transport mode for soil under freezing conditions 被引量:2
18
作者 WeiNan Mao JianKun Liu 《Research in Cold and Arid Regions》 CSCD 2013年第4期413-417,共5页
A coupled water and heat transport mode is established based on the Richards equation to study water flow and heat transport in soil during freezing process. Both the finite difference and finite element method are us... A coupled water and heat transport mode is established based on the Richards equation to study water flow and heat transport in soil during freezing process. Both the finite difference and finite element method are used in the discretization, respectively. Two different computer programs are written and used to simulate an indoor unidirectional frozen test. The freezing depth, freezing rate and temperature variation are compared among lab tests, finite difference calculation simulation and finite element calculation simulation. Result shows that: the finite difference method has a better performance in freezing depth simulation while the finite element method has a better performance in numerical stability in one-dimensional freezing simulation. 展开更多
关键词 freezing soil coupled water and heat finite difference finite element freezing test simulation
下载PDF
Modelling plant canopy effects on water-heat exchange in the freezingthawing processes of active layer on the Qinghai-Tibet Plateau 被引量:2
19
作者 GUO Lin-mao CHANG Juan +1 位作者 XU Hong-liang SUN Wen-jun 《Journal of Mountain Science》 SCIE CSCD 2021年第6期1564-1579,共16页
The effect of vegetation on the water-heat exchange in the freezing-thawing processes of active layer is one of the key issues in the study of land surface processes and in predicting the response of alpine ecosystems... The effect of vegetation on the water-heat exchange in the freezing-thawing processes of active layer is one of the key issues in the study of land surface processes and in predicting the response of alpine ecosystems to climate change in permafrost regions. In this study, we used the simultaneous heat and water model to investigate the effects of plant canopy on surface and subsurface hydrothermal dynamics in the Fenghuoshan area of the QinghaiTibet Plateau by changing the leaf area index(LAI) and keeping other variables constant. Results showed that the sensible heat, latent heat and net radiation are increased with an increase in the LAI. However, the ground heat flux decreased with an increasing LAI. The annual total evapotranspiration and vegetation transpiration ranged from-16% to 9% and-100% to 15%, respectively, in response to extremes of doubled and zero LAI, respectively. There was a negative feedback between vegetation and the volumetric unfrozen water content at 0.2 m through changing evapotranspiration. The simulation results of soil temperature and moisture suggest that better vegetation conditions are conducive to maintaining the thermal stability of the underlying permafrost, and the advanced initial thawing time and increasing thawing rate of soil ice with the increase in the LAI may have a great influence on the timing and magnitude of supra-permafrost groundwater. This study quantifies the impact of vegetation change on surface and subsurface hydrothermal processes and provides a basic understanding for evaluating the impact of vegetation degradation on the water-heat exchange in permafrost regions under climate change. 展开更多
关键词 PERMAFROST Simultaneous heat and water model Leaf area index water-Heat exchange Thermal-moisture dynamics
原文传递
Modeling water and carbon fluxes above summer maize field in North China Plain with back-propagation neural networks 被引量:1
20
作者 秦钟 苏高利 +2 位作者 于强 胡秉民 李俊 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE EI CAS CSCD 2005年第5期418-426,共9页
In this work, datasets of water and carbon fluxes measured with eddy covariance technique above a summer maize field in the North China Plain were simulated with artificial neural networks (ANNs) to explore the fluxes... In this work, datasets of water and carbon fluxes measured with eddy covariance technique above a summer maize field in the North China Plain were simulated with artificial neural networks (ANNs) to explore the fluxes responses to local environmental variables. The results showed that photosynthetically active radiation (PAR), vapor pressure deficit (VPD), air temperature (T) and leaf area index (LAI) were primary factors regulating both water vapor and carbon dioxide fluxes. Three-layer back-propagation neural networks (BP) could be applied to model fluxes exchange between cropland surface and atmosphere without using detailed physiological information or specific parameters of the plant. 展开更多
关键词 Carbon dioxide water vapor and heat fluxes Three-layer back-propagation neural networks
下载PDF