期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Determination of fluorinated quinolone antibacterials by ion chromatography with fluorescence detection 被引量:4
1
作者 ZHANG Yan-zhen ZHANG Zheng-yi +2 位作者 ZHOU Yan-chun LIU Li ZHU Yan 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第5期302-306,共5页
For preparing fluorinated quinolone antibiotic medicine locally used in stomatology, simultaneous determination of norfloxacin, ciprofloxacin, and enoxacin was carried out by multiphase ion chromatography with fluores... For preparing fluorinated quinolone antibiotic medicine locally used in stomatology, simultaneous determination of norfloxacin, ciprofloxacin, and enoxacin was carried out by multiphase ion chromatography with fluorescence detection. Quinolone antibiotics were separated by Dionex OmniPac PAX-500 column with an eluent of 15 mmol/L H2SO4 and 35% methanol (v/v) at a flow-rate of 1.0 ml/min and detected with fluorescence with excitation and emission wave lengths of 347 nm and 420 nm respectively. The detection limits (S/N=3) of norfloxacin, ciprofloxacin and enoxacin were 50, 105 and 80 ng/ml respectively. The relative standard deviations of retention time, peak area and peak height were less than 1.1% and good linear relationship resulted. The developed method was applied to pharmaceutical formulations and biological fluids. 展开更多
关键词 氟化喹诺酮 抗菌药 离子色谱法 荧光检测 测定
下载PDF
Stabilization of an abutment under a rigidly fixed bridge by holographical-speckle interferometry 被引量:2
2
作者 ZHANG Yan-zhen ZHOU Yan-chun +2 位作者 LIU Li LU Yang HIROFUMI Yatani 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第6期416-421,共6页
Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This wo... Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data. Methods: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle. Results: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar. Conclusion: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively. 展开更多
关键词 刚性固定桥 桥基 激光全息散斑干涉测量 牙缺损 修复
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部