The differential equations of continuum mechanics are the basis of an uncountable variety of phenomena and technological processes in fluid-dynamics and related fields.These equations contain derivatives of the first ...The differential equations of continuum mechanics are the basis of an uncountable variety of phenomena and technological processes in fluid-dynamics and related fields.These equations contain derivatives of the first order with respect to time.The derivation of the equations of continuum mechanics uses the limit transitions of the tendency of the volume increment and the time increment to zero.Derivatives are used to derive the wave equation.The differential wave equation is second order in time.Therefore,increments of volume and increments of time in continuum mechanics should be considered as small but finite quantities for problems of wave formation.This is important for calculating the generation of sound waves and water hammer waves.Therefore,the Euler continuity equation with finite time increments is of interest.The finiteness of the time increment makes it possible to take into account the quadratic and cubic invariants of the strain rate tensor.This is a new branch in hydrodynamics.Quadratic and cubic invariants will be used in differential wave equations of the second and third order in time.展开更多
This study investigates the use of waste fat biodiesel(WFB)from the leather industry as a substitute for diesel fuel.Specifically,it examines the diesel engine performance of WFB,a blend of WFB and diesel(B50),and dif...This study investigates the use of waste fat biodiesel(WFB)from the leather industry as a substitute for diesel fuel.Specifically,it examines the diesel engine performance of WFB,a blend of WFB and diesel(B50),and different blends of WFB and silicon dioxide(SiO_(2))nanoparticles(B50SiO_(2)40,B50SiO_(2)80,and B50SiO_(2)120μg/g).The results indicate that the B50SiO_(2)120 blend increases brake thermal efficiency by 10.03%compared to pure biodiesel but falls 1.93%short of neat diesel.Furthermore,the B50SiO_(2)120 mixture reduces smoke,hydrocarbon,and carbon monoxide emissions by 31.87%,34.14%,and 43.97%respectively,compared to diesel.However,the B50SiO_(2)120 blend shows a 4.91%increase in nitrogen oxide emissions compared to diesel.展开更多
Temperature fluctuations in a mixing T-junction have been simulated on the FLUENT platform using the large eddy simulation (LES) turbulent flow model and a sub-grid scale Smagorinsky-Lilly model. The normalized mean...Temperature fluctuations in a mixing T-junction have been simulated on the FLUENT platform using the large eddy simulation (LES) turbulent flow model and a sub-grid scale Smagorinsky-Lilly model. The normalized mean and root mean square temperatures for describing time-averaged temperature and temperature fluctuation intensity, and the velocity are obtained. The power spectrum densities of temperature fluctuations, which are key parameters for thermal fatigue analysis and lifetime evaluation, are analyzed. Simulation results are consistent with experimental data published in the literature, showing that the LES is reliable. Several mixing processes under different conditions are simulated in order to analyze the effects of varying Reynolds number and Richardson number on the mixing course and thermal fluctuations.展开更多
An analysis of the sectorial structure of energy consumption shows that residential and tertiary sector buildings are the third-highest consumers,responsible for 29.5%of a city’s final energy consumption.The Building...An analysis of the sectorial structure of energy consumption shows that residential and tertiary sector buildings are the third-highest consumers,responsible for 29.5%of a city’s final energy consumption.The Building Quality Control Laboratory of the Basque Government aims to promote quality,innovation,and sustainability in buildings.To accomplish this goal,it has constructed an experimental facility with different energy generation technologies and a very versatile control system for testing different energy systems and operation modes.In this study,we tested a facility for supplying domestic hot water and heating for a multi-family house by means of a condensing boiler and an aerothermal heat pump(together with the corresponding control).This installation could reproduce the thermal demands required to be satisfied by the generation equipment through a programmed operation of the installation based on real demands.Additionally,this installation was analyzed using thermoeconomics(TE)to solve problems unable to be solved using traditional energy analyses based on the First Law of Thermodynamics.These problems include:(1)Determining the costs of the products of the installation based on physical criteria,(2)detecting the places where losses actually occur,evaluating their costs,and proposing cost-effective improvements,and(3)diagnosing issues in the installation.As a result,this paper suggests a solution to the preventive maintenance problems confronting the technical maintenance personnel for thermal installations in buildings by applying TE knowledge and using real data collected from sensors.展开更多
In this study,the open-source software MFIX-DEM simulations of a bubbling fluidized bed(BFB)are applied to assess nine drag models according to experimental and direct numerical simulation(DNS)results.The influence of...In this study,the open-source software MFIX-DEM simulations of a bubbling fluidized bed(BFB)are applied to assess nine drag models according to experimental and direct numerical simulation(DNS)results.The influence of superficial gas velocity on gas–solid flow is also examined.The results show that according to the distribution of time-averaged particle axial velocity in y direction,except for Wen–Yu and Tenneti–Garg–Subramaniam(TGS),other drag models are consistent with the experimental and DNS results.For the TGS drag model,the layer-by-layer movement of particles is observed,which indicates the particle velocity is not correctly predicted.The time domain and frequency domain analysis results of pressure drop of each drag model are similar.It is recommended to use the drag model derived from DNS or fine grid computational fluid dynamics–discrete element method(CFD-DEM)data first for CFD-DEM simulations.For the investigated BFB,the superficial gas velocity less than 0.9 m·s^(-1) should be adopted to obtain normal hydrodynamics.展开更多
This study investigated the influence of precipitators and wet flue gas desulfurization equipment on characteristics of PM_(2.5)emission from coal-fired power stations.We measured size distribution and removal efficie...This study investigated the influence of precipitators and wet flue gas desulfurization equipment on characteristics of PM_(2.5)emission from coal-fired power stations.We measured size distribution and removal efficiencies,including hybrid electrostatic precipitator/bag filters(ESP/BAGs)which have rarely been studied.A bimodal distribution of particle concentrations was observed at the inlet of each precipitator.After the precipitators,particle concentrations were significantly reduced.Although a bimodal distribution was still observed,all peak positions shifted to the smaller end.The removal efficiencies of hybrid ESP/BAGs reached 99%for PM_(2.5),which is considerably higher than those for other types of precipitators.In particular,the influence of hybrid ESP/BAG operating conditions on the performance of dust removal was explored.The efficiency of hybrid ESP/BAGs decreased by 1.9%when the first electrostatic field was shut down.The concentrations and distributions of particulate matter were also measured in three coal-fired power plants before and after desulfurization devices.The results showed diverse removal efficiencies for different desulfurization towers.The reason for the difference requires further research.We estimated the influence of removal technology for particulate matter on total emissions in China.Substituting ESPs with hybrid ESP/BAGs could reduce the total emissions to 104.3 thousand tons,with 47.48 thousand tons of PM_(2.5).展开更多
Coal is the dominant primary energy source in China and the major source of greenhouse gases and air pollutants. To facilitate the use of coal in an environmentally satisfactory and economically viable way, clean coal...Coal is the dominant primary energy source in China and the major source of greenhouse gases and air pollutants. To facilitate the use of coal in an environmentally satisfactory and economically viable way, clean coal technologies (CCTs) are necessary. This paper presents a review of recent research and development of four kinds of CCTs: coal power generation; coal conversion; pollution control; and carbon capture, utilization, and storage. It also outlines future perspectives on directions for technology re search and development (R&D). This review shows that China has made remarkable progress in the R&D of CCTs, and that a number of CCTs have now entered into the commercialization stage.展开更多
Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion...Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion was dependent on temperature and was greatly accelerated by ash deposition.The mass gain was distinctly reduced in the presence of SO2 with and without ash deposition on the specimens.Corrosion rates with ash deposit at different temperatures were calculated.Two feasible methods were provided to avoid serious high-temperature corrosion in the biomass boiler.展开更多
We derive the expressions of the first and second harmonic signals on the basis of absorption spectral and lock-in theories, and determine the gas concentration according to the ratio of second and first harmonic sign...We derive the expressions of the first and second harmonic signals on the basis of absorption spectral and lock-in theories, and determine the gas concentration according to the ratio of second and first harmonic signals. It is found that the X and Y components of the harmonic signals are influenced by the phase shift between the detection and reference signal, and the phase shift can be any value in a range from 0 to 2π, which is different from the results obtained previously. Meanwhile, an additional item caused by the residual amplitude modulation will make a great contribution to the second harmonic signal, and may not be neglected under low absorbance conditions. Theoretical analysis indicates that subtracting back-ground signal from the second harmonic signal can remove the influence of this item, and can improve the measurement accuracy of gas concentration. On this basis, we select the transition of CO2 at 6527.64 cm-1 to analyse the approximation errors during the derivation by numerical simulation and then measure the CO2 concentration under low absorbance conditions, with absorbance varying from 1‰ to 6‰.展开更多
Observation and measurement were conducted to investigate contact angle andits hysteresis on rough surface. The experimental results indicate that the increase in solidsurface roughness enlarges advancing contact angl...Observation and measurement were conducted to investigate contact angle andits hysteresis on rough surface. The experimental results indicate that the increase in solidsurface roughness enlarges advancing contact angle and decreases receding contact angle, resultingin enhanced hysteresis. It was observed that when Young''s contact angle θ_Y 【 90°, as theroughness of solid surface increased the extent of the decrease in receding contact angle exceededthat of the increase in advancing contact angle. Based on the experimental observations, the conceptof hysteresis tension was introduced to describe the contact angle hysteresis behavior on roughsolid surface. The model provides a thoughtful understanding of the physical nature of contact anglehysteresis, in particular an instructive description of the influence of surface roughness on thehysteresis. The prediction of the model is found in quite good agreement with the experimentalobservation and measurement.展开更多
The dynamic stall problem for blades is related to the general performance of wind turbines,where a varying flow field is introduced with a rapid change of the effective angle of attack (AOA).The objective of this wor...The dynamic stall problem for blades is related to the general performance of wind turbines,where a varying flow field is introduced with a rapid change of the effective angle of attack (AOA).The objective of this work is to study the aerodynamic performance of a sinusoidally oscillating NACA0012 airfoil.The coupled k-ω Menter's shear stress transport (SST) turbulence model and γ-Reθ transition model were used for turbulence closure.Lagrangian coherent structures (LCS) were utilized to analyze the dynamic behavior of the flow structures.The computational results were supported by the experiments.The results indicated that this numerical method can well describe the dynamic stall process.For the case with reduced frequency K =0.1,the lift and drag coefficients increase constantly with increasing angle prior to dynamic stall.When the AOA reaches the stall angle,the lift and drag coefficients decline suddenly due to the interplay between the first leading-and trailing-edge vortex.With further increase of the AOA,both the lift and drag coefficients experience a secondary rise and fall process because of formation and shedding of the secondary vortex.The results also reveal that the dynamic behavior of the flow structures can be effectively identified using the finite-time Lyapunov exponent (FTLE) field.The influence of the reduced frequency on the flow structures and energy extraction efficiency in the dynamic stall process is further discussed.When the reduced frequency increases,the dynamic stall is delayed and the total energy extraction efficiency is enhanced.With K =0.05,the amplitude of the dynamic coefficients fluctuates more significantly in the poststall process than in the case of K =0.1.展开更多
An improved large eddy simulation using a dynamic second-order sub-grid-scale (SGS) stress model has been developed to model the governing equations of dense turbulent particle-liquid two-phase flows in a rotating c...An improved large eddy simulation using a dynamic second-order sub-grid-scale (SGS) stress model has been developed to model the governing equations of dense turbulent particle-liquid two-phase flows in a rotating coordinate system, and continuity is conserved by a mass-weighted method to solve the filtered governing equations. In the cur- rent second-order SGS model, the SGS stress is a function of both the resolved strain-rate and rotation-rate tensors, and the model parameters are obtained from the dimensional consistency and the invariants of the strain-rate and the rotation-rate tensors. In the numerical calculation, the finite volume method is used to discretize the governing equations with a staggered grid system. The SIMPLEC algorithm is applied for the solution of the discretized governing equations. Body- fitted coordinates are used to simulate the two-phase flows in complex geometries. Finally the second-order dynamic SGS model is successfully applied to simulate the dense turbu-lent particle-liquid two-phase flows in a centrifugal impeller. The predicted pressure and velocity distributions are in good agreement with experimental results.展开更多
Based on assuming that there is the precursor film in the front of the apparent contact line (ACL), a model was proposed to understand the dynamic wetting process and associated dynamic contact angle. The present mo...Based on assuming that there is the precursor film in the front of the apparent contact line (ACL), a model was proposed to understand the dynamic wetting process and associated dynamic contact angle. The present model indicated that a new dimensionless characteristic parameter, 2, attects the dynamic wetting process and associated dynamic contact angle as well. However, the previous model suggested that the dynamic contact angle is dependent'on the capillary number and static contact angle only. An experimental investigation was conducted to measure the dynamic wetting behavior of silicon oil moving over glass, aluminum and stainless steel surfaces. It concluded that when the value of 2 was selected as 0.07, 0.16 and 0.35 for glass, aluminum and stainless steel, respectively, the experimental results were in good accordance with the prediction of the model. Furthermore, the comparison of the model with Strom's experimental data showed that 2 is independent on the species of liquids. Apparently, 2 should be interpreted as the effect of the solid surface properties on the dynamic wetting process.Meanwhile, it is found in the present experiment that the Hoffman-Voinov-Tanner law, which is valid at very low capillary number (Ca 〈〈 1 or 80〈 10°) recommend by Cazabat, still holds for higher contact angles, even up to 70°-80°. This is explained by (he present model very well.展开更多
The test results of sealing performance and a comparison between three types of honeycomb seals and a type of labyrinth seal are presented, which have different seal clearances and work under various rotor speeds. It ...The test results of sealing performance and a comparison between three types of honeycomb seals and a type of labyrinth seal are presented, which have different seal clearances and work under various rotor speeds. It has been found that the honeycomb seal leakage during a rotor speed of 6000 r/min decreases by about 4.8 percent as compared with that during a rotor speed of 0 r/min. At a radial clearance of 0.12 mm the honeycomb seal with a cell size of 1.6 mm enjoys the best sealing performance. The leakage flow of the labyrinth seal with a radial clearance of 0.06 mm is smaller than that of the honeycomb seals.展开更多
Current research on pump-turbine units is focused on the unstable operation at off-design conditions, with the characteristic curves in generating mode being S-shaped. Unlike in the traditional water turbines, pump-tu...Current research on pump-turbine units is focused on the unstable operation at off-design conditions, with the characteristic curves in generating mode being S-shaped. Unlike in the traditional water turbines, pump-turbine operation along the S-shaped curve can lead to difficulties during load rejection with unusual increases in the water pressure, which leads to machine vibrations. This paper describes both model tests and numerical simulations. A reduced scale model of a low specific speed pump-turbine was used for the performance tests, with comparisons to computational fluid dynamics(CFD) results. Predictions using the detached eddy simulation(DES) turbulence model, which is a combined Reynolds averaged Naviers-Stokes(RANS) and large eddy simulation(LES) model, are compared with the two-equation turbulence mode results. The external characteristics as well as the internal flow are for various guide vane openings to understand the unsteady flow along the so called S characteristics of a pump-turbine. Comparison of the experimental data with the CFD results for various conditions and times shows that DES model gives better agreement with experimental data than the two-equation turbulence model. For low flow conditions, the centrifugal forces and the large incident angle create large vortices between the guide vanes and the runner inlet in the runner passage, which is the main factor leading to the S-shaped characteristics. The turbulence model used here gives more accurate simulations of the internal flow characteristics of the pump-turbine and a more detailed force analysis which shows the mechanisms controlling of the S characteristics.展开更多
The effect of moisture in municipal solid waste (MSW) on partitioning of lead (Pb), zinc (Zn), copper (Cu) and cadmium (Cd) was studied in a laboratory tubular furnace by using simulated MSW. The moisture in MSW influ...The effect of moisture in municipal solid waste (MSW) on partitioning of lead (Pb), zinc (Zn), copper (Cu) and cadmium (Cd) was studied in a laboratory tubular furnace by using simulated MSW. The moisture in MSW influences heavy metals in following ways, to increase the moisture in flue gas and decrease the combustion temperature, to prolong the combustion time, and to prolong the releasing time of volatiles with the furnace temperature decreased by increasing the moisture. The volatilization of Pb, Zn and Cd was enhanced by increasing the moisture in MSW because of the prolonged combustion time. For Pb and Zn, the combustion time was important at higher temperature, while for Cd, it was important at low temperature. The moisture content showed slight effect on Cu partitioning. When extra chlorine was added to MSW, such as 1%PVC + 0.5%NaCl, the volatilization of Pb, Zn and Cu was enhanced by increasing the moisture because water evaporation reduced the temperature and increased devolatilization time. At higher temperature, NaCl tends to decompose and generates more free chlorine, producing more metal chlorides. Since Cd is a strong volatile heavy metal in MSW, the effect of moisture content on its volatilization is less than that of Pb, Zn or Cu during the MSW incineration.展开更多
The characteristics of oxy-coal combustion for a swirl burner with a specially designed preheating chamber are studied numerically. In order to increase the accuracy in the prediction of flame temperature and igni- ti...The characteristics of oxy-coal combustion for a swirl burner with a specially designed preheating chamber are studied numerically. In order to increase the accuracy in the prediction of flame temperature and igni- tion position, eddy dissipation concept (EDC) model with a skeletal chemical reaction mechanism was adopted to describe the combustion of volatile matter. Simulation was conducted under six oxidant stream conditions with dif- ferent OjN2/CO2 molar ratios: 21/79/0, 30/70/0, 50/50/0, 21/0/79, 30/0/70 and 50/0/50. Results showed that 02 en- richment in the primary oxidant stream is in favor of combustion stabilization, acceleration of ignition and increase of maximum flame temperature, while the full substitution of N2 by CO2 in the oxidant stream delays ignition and decreases the maximum flame temperature. However, the overall flow field and flame shapes in these cases are very similar at the same flow rate of the primary oxidant stream. Combustion characteristics of the air-coal is similar to that of the oxy-coal with 30% 02 and 70% CO2 in the oxidant stream, indicating that the rear condition is suitable for retrofitting an air-coal fired boiler to an oxy-coal one. The swirl burner with a specially designed preheating chamber can increase flame temperature, accelerate ignition and enhance burning intensity of pulverized coal under oxy-coal combustion. Also, qualitative experimental validation indicated the burner can reduce the overall NOx emission under certain 02 enrichment and oxy-coal combustion conditions against the air-coal combustion.展开更多
Experimental studies of a model pump-turbine S-curve characteristics and its improvement by misaligned guide vanes (MGV) were extended to prototype pump turbine through 3-D transient flow simulations. The unsteady R...Experimental studies of a model pump-turbine S-curve characteristics and its improvement by misaligned guide vanes (MGV) were extended to prototype pump turbine through 3-D transient flow simulations. The unsteady Reynolds-averaged Navier-Stokes equations with the SST turbulence model were used to model the transient flow within the entire flow passage of a reversible pump-turbine with and without misaligned guide vanes during turbine model start-up. The unstable S-curve and its improvement by using misaligned guide vane were verified by model test and simulation. The transient flow calculations were used to clarify the variations of pressure pulse and internal flow behavior in the entire flow passage. The use of misaligned guide vanes can eliminate the S-curve characteristics of a pump-turbine, and can significantly increase the pressure pulse amplitude in the entire flow passage and the runner radial forces during start-up. The MGV only decreased the pulse amplitude on the guide vane suction side when the rotating speed was less than 50% rated speed. The hydraulic reason is that the MGV dramatically changed the flow patterns inside the entire flow passage, and destroyed the symmetry of the flow distribution inside the guide vane and runner.展开更多
The wavelength dependence of laser induced breakdown spectroscopy (LIBS) in the analysis of the carbon contents of coal was studied using 266 nm and 1064 nm laser radiations. Compared with the 1064 nm wavelength las...The wavelength dependence of laser induced breakdown spectroscopy (LIBS) in the analysis of the carbon contents of coal was studied using 266 nm and 1064 nm laser radiations. Compared with the 1064 nm wavelength laser ablation, the 266 nm wavelength laser ablation has less thermal effects, resulting in a better crater morphology on the coal pellets. Besides, the 266 nm wavelength laser ablation also provides better laser-sample coupling and less plasma shielding, resulting in a higher carbon line intensity and better signal reproducibility. The carbon contents in the bituminous coal samples have better linearity with the line intensities of atomic carbon measured by the 266 nm wavelength than those measured by the 1064 nm wavelength. The partial least square (PLS) model was established for the quantitative analysis of the carbon content in coal samples by LIBS. The results show that both of the 266 nm and 1064 nm wavelengths are capable of achieving good performance for the quantitative analysis of carbon content in coal using the PLS method.展开更多
Oxides of silicon, aluminium and calcium are normally dominant minerals during municipal solid waste(MSW)combustion. In flue gas, Si O2, Al2O3 and Ca O all act as sorbents capturing heavy metals(and semi-volatile orga...Oxides of silicon, aluminium and calcium are normally dominant minerals during municipal solid waste(MSW)combustion. In flue gas, Si O2, Al2O3 and Ca O all act as sorbents capturing heavy metals(and semi-volatile organics). To further understand the effect of sorbents during MSW combustion, the effects of Si O2, Al2O3 and Ca O on Cu partitioning were experimentally investigated by the combustion of synthetic MSW in a tubular furnace and their effects on Cu speciation were studied by thermodynamic equilibrium calculations using Chem Kin software. The experiments show that Ca O has the highest Cu sorption efficiency at 900 °C, followed by Al2O3 and Si O2. Thermodynamic equilibrium calculations show that for Cu the addition of Si O2 and Al2O3reduces the amount of liquid Cu Cl, which is more volatile. However, the addition of Ca O has little influence on chemical sorption of Cu, indicating that the sorption of Ca O is resulted from physical sorption.展开更多
文摘The differential equations of continuum mechanics are the basis of an uncountable variety of phenomena and technological processes in fluid-dynamics and related fields.These equations contain derivatives of the first order with respect to time.The derivation of the equations of continuum mechanics uses the limit transitions of the tendency of the volume increment and the time increment to zero.Derivatives are used to derive the wave equation.The differential wave equation is second order in time.Therefore,increments of volume and increments of time in continuum mechanics should be considered as small but finite quantities for problems of wave formation.This is important for calculating the generation of sound waves and water hammer waves.Therefore,the Euler continuity equation with finite time increments is of interest.The finiteness of the time increment makes it possible to take into account the quadratic and cubic invariants of the strain rate tensor.This is a new branch in hydrodynamics.Quadratic and cubic invariants will be used in differential wave equations of the second and third order in time.
文摘This study investigates the use of waste fat biodiesel(WFB)from the leather industry as a substitute for diesel fuel.Specifically,it examines the diesel engine performance of WFB,a blend of WFB and diesel(B50),and different blends of WFB and silicon dioxide(SiO_(2))nanoparticles(B50SiO_(2)40,B50SiO_(2)80,and B50SiO_(2)120μg/g).The results indicate that the B50SiO_(2)120 blend increases brake thermal efficiency by 10.03%compared to pure biodiesel but falls 1.93%short of neat diesel.Furthermore,the B50SiO_(2)120 mixture reduces smoke,hydrocarbon,and carbon monoxide emissions by 31.87%,34.14%,and 43.97%respectively,compared to diesel.However,the B50SiO_(2)120 blend shows a 4.91%increase in nitrogen oxide emissions compared to diesel.
基金supported by the National Natural Science Foundation of China (No.50906002)Beijing Novel Program (No.2008B16)
文摘Temperature fluctuations in a mixing T-junction have been simulated on the FLUENT platform using the large eddy simulation (LES) turbulent flow model and a sub-grid scale Smagorinsky-Lilly model. The normalized mean and root mean square temperatures for describing time-averaged temperature and temperature fluctuation intensity, and the velocity are obtained. The power spectrum densities of temperature fluctuations, which are key parameters for thermal fatigue analysis and lifetime evaluation, are analyzed. Simulation results are consistent with experimental data published in the literature, showing that the LES is reliable. Several mixing processes under different conditions are simulated in order to analyze the effects of varying Reynolds number and Richardson number on the mixing course and thermal fluctuations.
文摘An analysis of the sectorial structure of energy consumption shows that residential and tertiary sector buildings are the third-highest consumers,responsible for 29.5%of a city’s final energy consumption.The Building Quality Control Laboratory of the Basque Government aims to promote quality,innovation,and sustainability in buildings.To accomplish this goal,it has constructed an experimental facility with different energy generation technologies and a very versatile control system for testing different energy systems and operation modes.In this study,we tested a facility for supplying domestic hot water and heating for a multi-family house by means of a condensing boiler and an aerothermal heat pump(together with the corresponding control).This installation could reproduce the thermal demands required to be satisfied by the generation equipment through a programmed operation of the installation based on real demands.Additionally,this installation was analyzed using thermoeconomics(TE)to solve problems unable to be solved using traditional energy analyses based on the First Law of Thermodynamics.These problems include:(1)Determining the costs of the products of the installation based on physical criteria,(2)detecting the places where losses actually occur,evaluating their costs,and proposing cost-effective improvements,and(3)diagnosing issues in the installation.As a result,this paper suggests a solution to the preventive maintenance problems confronting the technical maintenance personnel for thermal installations in buildings by applying TE knowledge and using real data collected from sensors.
基金the China-CEEC Joint Higher Education Project(Cultivation Project)(CEEC2021001)Srdjan Beloševic,Aleksandar Milicevic and Ivan Tomanovic acknowledge the financial support by the Ministry of Science,Technological Development and Innovation of the Republic of Serbia(Contract Annex:451-03-47/2023-01/200017).
文摘In this study,the open-source software MFIX-DEM simulations of a bubbling fluidized bed(BFB)are applied to assess nine drag models according to experimental and direct numerical simulation(DNS)results.The influence of superficial gas velocity on gas–solid flow is also examined.The results show that according to the distribution of time-averaged particle axial velocity in y direction,except for Wen–Yu and Tenneti–Garg–Subramaniam(TGS),other drag models are consistent with the experimental and DNS results.For the TGS drag model,the layer-by-layer movement of particles is observed,which indicates the particle velocity is not correctly predicted.The time domain and frequency domain analysis results of pressure drop of each drag model are similar.It is recommended to use the drag model derived from DNS or fine grid computational fluid dynamics–discrete element method(CFD-DEM)data first for CFD-DEM simulations.For the investigated BFB,the superficial gas velocity less than 0.9 m·s^(-1) should be adopted to obtain normal hydrodynamics.
基金Supported by the National Basic Research Pro-gram of China(973 Program)(2013CB228506).
文摘This study investigated the influence of precipitators and wet flue gas desulfurization equipment on characteristics of PM_(2.5)emission from coal-fired power stations.We measured size distribution and removal efficiencies,including hybrid electrostatic precipitator/bag filters(ESP/BAGs)which have rarely been studied.A bimodal distribution of particle concentrations was observed at the inlet of each precipitator.After the precipitators,particle concentrations were significantly reduced.Although a bimodal distribution was still observed,all peak positions shifted to the smaller end.The removal efficiencies of hybrid ESP/BAGs reached 99%for PM_(2.5),which is considerably higher than those for other types of precipitators.In particular,the influence of hybrid ESP/BAG operating conditions on the performance of dust removal was explored.The efficiency of hybrid ESP/BAGs decreased by 1.9%when the first electrostatic field was shut down.The concentrations and distributions of particulate matter were also measured in three coal-fired power plants before and after desulfurization devices.The results showed diverse removal efficiencies for different desulfurization towers.The reason for the difference requires further research.We estimated the influence of removal technology for particulate matter on total emissions in China.Substituting ESPs with hybrid ESP/BAGs could reduce the total emissions to 104.3 thousand tons,with 47.48 thousand tons of PM_(2.5).
基金Acknowledgements The authors gratefully acknowledge the funding support from the National Key Basic Research Program of China (2013CB228500), the National Natural Science Foundation of Chi- na (71203119), and the Advanced Coal Technology Consortium of CERC (2016YFE0102500).
文摘Coal is the dominant primary energy source in China and the major source of greenhouse gases and air pollutants. To facilitate the use of coal in an environmentally satisfactory and economically viable way, clean coal technologies (CCTs) are necessary. This paper presents a review of recent research and development of four kinds of CCTs: coal power generation; coal conversion; pollution control; and carbon capture, utilization, and storage. It also outlines future perspectives on directions for technology re search and development (R&D). This review shows that China has made remarkable progress in the R&D of CCTs, and that a number of CCTs have now entered into the commercialization stage.
文摘Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion was dependent on temperature and was greatly accelerated by ash deposition.The mass gain was distinctly reduced in the presence of SO2 with and without ash deposition on the specimens.Corrosion rates with ash deposit at different temperatures were calculated.Two feasible methods were provided to avoid serious high-temperature corrosion in the biomass boiler.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51176085 and 51206086)
文摘We derive the expressions of the first and second harmonic signals on the basis of absorption spectral and lock-in theories, and determine the gas concentration according to the ratio of second and first harmonic signals. It is found that the X and Y components of the harmonic signals are influenced by the phase shift between the detection and reference signal, and the phase shift can be any value in a range from 0 to 2π, which is different from the results obtained previously. Meanwhile, an additional item caused by the residual amplitude modulation will make a great contribution to the second harmonic signal, and may not be neglected under low absorbance conditions. Theoretical analysis indicates that subtracting back-ground signal from the second harmonic signal can remove the influence of this item, and can improve the measurement accuracy of gas concentration. On this basis, we select the transition of CO2 at 6527.64 cm-1 to analyse the approximation errors during the derivation by numerical simulation and then measure the CO2 concentration under low absorbance conditions, with absorbance varying from 1‰ to 6‰.
文摘Observation and measurement were conducted to investigate contact angle andits hysteresis on rough surface. The experimental results indicate that the increase in solidsurface roughness enlarges advancing contact angle and decreases receding contact angle, resultingin enhanced hysteresis. It was observed that when Young''s contact angle θ_Y 【 90°, as theroughness of solid surface increased the extent of the decrease in receding contact angle exceededthat of the increase in advancing contact angle. Based on the experimental observations, the conceptof hysteresis tension was introduced to describe the contact angle hysteresis behavior on roughsolid surface. The model provides a thoughtful understanding of the physical nature of contact anglehysteresis, in particular an instructive description of the influence of surface roughness on thehysteresis. The prediction of the model is found in quite good agreement with the experimentalobservation and measurement.
基金the National Postdoctoral Program for Innovative Talents(Grant BX201700126)the China Postdoctoral Science Foundation(Grant 2017M620043)+1 种基金the National Natural Science Foundation of China(Grants 51679005 and 91752105)the National Natural Science Foundation of Beijing(Grant 3172029).
文摘The dynamic stall problem for blades is related to the general performance of wind turbines,where a varying flow field is introduced with a rapid change of the effective angle of attack (AOA).The objective of this work is to study the aerodynamic performance of a sinusoidally oscillating NACA0012 airfoil.The coupled k-ω Menter's shear stress transport (SST) turbulence model and γ-Reθ transition model were used for turbulence closure.Lagrangian coherent structures (LCS) were utilized to analyze the dynamic behavior of the flow structures.The computational results were supported by the experiments.The results indicated that this numerical method can well describe the dynamic stall process.For the case with reduced frequency K =0.1,the lift and drag coefficients increase constantly with increasing angle prior to dynamic stall.When the AOA reaches the stall angle,the lift and drag coefficients decline suddenly due to the interplay between the first leading-and trailing-edge vortex.With further increase of the AOA,both the lift and drag coefficients experience a secondary rise and fall process because of formation and shedding of the secondary vortex.The results also reveal that the dynamic behavior of the flow structures can be effectively identified using the finite-time Lyapunov exponent (FTLE) field.The influence of the reduced frequency on the flow structures and energy extraction efficiency in the dynamic stall process is further discussed.When the reduced frequency increases,the dynamic stall is delayed and the total energy extraction efficiency is enhanced.With K =0.05,the amplitude of the dynamic coefficients fluctuates more significantly in the poststall process than in the case of K =0.1.
基金the National Natural Science Foundation of China(50779069 and 90510007)the Start-up Scientific Research Foundation of China Agricultural University(2006021)the Beijing Natural Science Foundation(3071002).
文摘An improved large eddy simulation using a dynamic second-order sub-grid-scale (SGS) stress model has been developed to model the governing equations of dense turbulent particle-liquid two-phase flows in a rotating coordinate system, and continuity is conserved by a mass-weighted method to solve the filtered governing equations. In the cur- rent second-order SGS model, the SGS stress is a function of both the resolved strain-rate and rotation-rate tensors, and the model parameters are obtained from the dimensional consistency and the invariants of the strain-rate and the rotation-rate tensors. In the numerical calculation, the finite volume method is used to discretize the governing equations with a staggered grid system. The SIMPLEC algorithm is applied for the solution of the discretized governing equations. Body- fitted coordinates are used to simulate the two-phase flows in complex geometries. Finally the second-order dynamic SGS model is successfully applied to simulate the dense turbu-lent particle-liquid two-phase flows in a centrifugal impeller. The predicted pressure and velocity distributions are in good agreement with experimental results.
基金Supported by the National Natural Science Foundation of China (Nos.50636020, 50406001).
文摘Based on assuming that there is the precursor film in the front of the apparent contact line (ACL), a model was proposed to understand the dynamic wetting process and associated dynamic contact angle. The present model indicated that a new dimensionless characteristic parameter, 2, attects the dynamic wetting process and associated dynamic contact angle as well. However, the previous model suggested that the dynamic contact angle is dependent'on the capillary number and static contact angle only. An experimental investigation was conducted to measure the dynamic wetting behavior of silicon oil moving over glass, aluminum and stainless steel surfaces. It concluded that when the value of 2 was selected as 0.07, 0.16 and 0.35 for glass, aluminum and stainless steel, respectively, the experimental results were in good accordance with the prediction of the model. Furthermore, the comparison of the model with Strom's experimental data showed that 2 is independent on the species of liquids. Apparently, 2 should be interpreted as the effect of the solid surface properties on the dynamic wetting process.Meanwhile, it is found in the present experiment that the Hoffman-Voinov-Tanner law, which is valid at very low capillary number (Ca 〈〈 1 or 80〈 10°) recommend by Cazabat, still holds for higher contact angles, even up to 70°-80°. This is explained by (he present model very well.
基金National Emphases Basis Research Development and Programming Project(G1999022304)
文摘The test results of sealing performance and a comparison between three types of honeycomb seals and a type of labyrinth seal are presented, which have different seal clearances and work under various rotor speeds. It has been found that the honeycomb seal leakage during a rotor speed of 6000 r/min decreases by about 4.8 percent as compared with that during a rotor speed of 0 r/min. At a radial clearance of 0.12 mm the honeycomb seal with a cell size of 1.6 mm enjoys the best sealing performance. The leakage flow of the labyrinth seal with a radial clearance of 0.06 mm is smaller than that of the honeycomb seals.
基金Supported by National Natural Science Foundation of China(Grant No.51139007)State Key Laboratory of Hydroscience and Engineering Open Foundation of China(Grant No.2014-KY-05)
文摘Current research on pump-turbine units is focused on the unstable operation at off-design conditions, with the characteristic curves in generating mode being S-shaped. Unlike in the traditional water turbines, pump-turbine operation along the S-shaped curve can lead to difficulties during load rejection with unusual increases in the water pressure, which leads to machine vibrations. This paper describes both model tests and numerical simulations. A reduced scale model of a low specific speed pump-turbine was used for the performance tests, with comparisons to computational fluid dynamics(CFD) results. Predictions using the detached eddy simulation(DES) turbulence model, which is a combined Reynolds averaged Naviers-Stokes(RANS) and large eddy simulation(LES) model, are compared with the two-equation turbulence mode results. The external characteristics as well as the internal flow are for various guide vane openings to understand the unsteady flow along the so called S characteristics of a pump-turbine. Comparison of the experimental data with the CFD results for various conditions and times shows that DES model gives better agreement with experimental data than the two-equation turbulence model. For low flow conditions, the centrifugal forces and the large incident angle create large vortices between the guide vanes and the runner inlet in the runner passage, which is the main factor leading to the S-shaped characteristics. The turbulence model used here gives more accurate simulations of the internal flow characteristics of the pump-turbine and a more detailed force analysis which shows the mechanisms controlling of the S characteristics.
基金Supported by the National Basic Research Program of China (2011CB201502)
文摘The effect of moisture in municipal solid waste (MSW) on partitioning of lead (Pb), zinc (Zn), copper (Cu) and cadmium (Cd) was studied in a laboratory tubular furnace by using simulated MSW. The moisture in MSW influences heavy metals in following ways, to increase the moisture in flue gas and decrease the combustion temperature, to prolong the combustion time, and to prolong the releasing time of volatiles with the furnace temperature decreased by increasing the moisture. The volatilization of Pb, Zn and Cd was enhanced by increasing the moisture in MSW because of the prolonged combustion time. For Pb and Zn, the combustion time was important at higher temperature, while for Cd, it was important at low temperature. The moisture content showed slight effect on Cu partitioning. When extra chlorine was added to MSW, such as 1%PVC + 0.5%NaCl, the volatilization of Pb, Zn and Cu was enhanced by increasing the moisture because water evaporation reduced the temperature and increased devolatilization time. At higher temperature, NaCl tends to decompose and generates more free chlorine, producing more metal chlorides. Since Cd is a strong volatile heavy metal in MSW, the effect of moisture content on its volatilization is less than that of Pb, Zn or Cu during the MSW incineration.
基金Supported by the Chinese Ministry of Science and Technology Project(2011DFA60390)The National High Technology Research and Development Program of China(2007AA05Z303)
文摘The characteristics of oxy-coal combustion for a swirl burner with a specially designed preheating chamber are studied numerically. In order to increase the accuracy in the prediction of flame temperature and igni- tion position, eddy dissipation concept (EDC) model with a skeletal chemical reaction mechanism was adopted to describe the combustion of volatile matter. Simulation was conducted under six oxidant stream conditions with dif- ferent OjN2/CO2 molar ratios: 21/79/0, 30/70/0, 50/50/0, 21/0/79, 30/0/70 and 50/0/50. Results showed that 02 en- richment in the primary oxidant stream is in favor of combustion stabilization, acceleration of ignition and increase of maximum flame temperature, while the full substitution of N2 by CO2 in the oxidant stream delays ignition and decreases the maximum flame temperature. However, the overall flow field and flame shapes in these cases are very similar at the same flow rate of the primary oxidant stream. Combustion characteristics of the air-coal is similar to that of the oxy-coal with 30% 02 and 70% CO2 in the oxidant stream, indicating that the rear condition is suitable for retrofitting an air-coal fired boiler to an oxy-coal one. The swirl burner with a specially designed preheating chamber can increase flame temperature, accelerate ignition and enhance burning intensity of pulverized coal under oxy-coal combustion. Also, qualitative experimental validation indicated the burner can reduce the overall NOx emission under certain 02 enrichment and oxy-coal combustion conditions against the air-coal combustion.
基金supported by the National Natural Science Foundation of China(51009077)State Key Laboratory of Hydroscience and Engineering(2014-KY-05)
文摘Experimental studies of a model pump-turbine S-curve characteristics and its improvement by misaligned guide vanes (MGV) were extended to prototype pump turbine through 3-D transient flow simulations. The unsteady Reynolds-averaged Navier-Stokes equations with the SST turbulence model were used to model the transient flow within the entire flow passage of a reversible pump-turbine with and without misaligned guide vanes during turbine model start-up. The unstable S-curve and its improvement by using misaligned guide vane were verified by model test and simulation. The transient flow calculations were used to clarify the variations of pressure pulse and internal flow behavior in the entire flow passage. The use of misaligned guide vanes can eliminate the S-curve characteristics of a pump-turbine, and can significantly increase the pressure pulse amplitude in the entire flow passage and the runner radial forces during start-up. The MGV only decreased the pulse amplitude on the guide vane suction side when the rotating speed was less than 50% rated speed. The hydraulic reason is that the MGV dramatically changed the flow patterns inside the entire flow passage, and destroyed the symmetry of the flow distribution inside the guide vane and runner.
基金supported by National Natural Science Foundation of China(No.51276100)National Basic Research Program of China(973 Program)(No.2013CB228501)
文摘The wavelength dependence of laser induced breakdown spectroscopy (LIBS) in the analysis of the carbon contents of coal was studied using 266 nm and 1064 nm laser radiations. Compared with the 1064 nm wavelength laser ablation, the 266 nm wavelength laser ablation has less thermal effects, resulting in a better crater morphology on the coal pellets. Besides, the 266 nm wavelength laser ablation also provides better laser-sample coupling and less plasma shielding, resulting in a higher carbon line intensity and better signal reproducibility. The carbon contents in the bituminous coal samples have better linearity with the line intensities of atomic carbon measured by the 266 nm wavelength than those measured by the 1064 nm wavelength. The partial least square (PLS) model was established for the quantitative analysis of the carbon content in coal samples by LIBS. The results show that both of the 266 nm and 1064 nm wavelengths are capable of achieving good performance for the quantitative analysis of carbon content in coal using the PLS method.
基金Supported by the National Basic Research Program of China(2011CB201502)
文摘Oxides of silicon, aluminium and calcium are normally dominant minerals during municipal solid waste(MSW)combustion. In flue gas, Si O2, Al2O3 and Ca O all act as sorbents capturing heavy metals(and semi-volatile organics). To further understand the effect of sorbents during MSW combustion, the effects of Si O2, Al2O3 and Ca O on Cu partitioning were experimentally investigated by the combustion of synthetic MSW in a tubular furnace and their effects on Cu speciation were studied by thermodynamic equilibrium calculations using Chem Kin software. The experiments show that Ca O has the highest Cu sorption efficiency at 900 °C, followed by Al2O3 and Si O2. Thermodynamic equilibrium calculations show that for Cu the addition of Si O2 and Al2O3reduces the amount of liquid Cu Cl, which is more volatile. However, the addition of Ca O has little influence on chemical sorption of Cu, indicating that the sorption of Ca O is resulted from physical sorption.