期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
NOVEL DESIGN OF A BIOELECTRIC AMPLIFIER WITH MINIMIZED MAGNITUDE AND PHASE ERRORS 被引量:1
1
作者 Mashhour Bani Amer Assistant Professor 《Journal of Electronics(China)》 2001年第3期242-254,共13页
A new design of a bioelectric amplifier that has better parameters than conventional designs is presented. The design allows the construction of bioelectric amplifier with improved parameters in terms of common-mode r... A new design of a bioelectric amplifier that has better parameters than conventional designs is presented. The design allows the construction of bioelectric amplifier with improved parameters in terms of common-mode rejection ratio and phase and magnitude errors. The voltage gain is easily adapted to a wide range of biomedical applications. The experimental and simulation results of the designed bioelectric amplifier are also included. 展开更多
关键词 Bioelectric AMPLIFIER INSTRUMENTATION AMPLIFIER Common-mode REJECTION RATIO
下载PDF
Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer
2
作者 Xiaohao Wang Ran Liu +2 位作者 Fei Tang Yangchun Yu Zhaoying Zhou 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期80-82,共3页
In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (... In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer. 展开更多
关键词 data processing portable blood sugar analyzer dynamic linear detecting method
下载PDF
Analysis of secretome of breast cancer cell line with an optimized semi-shotgun method
3
作者 TANG Xiaorong YAO Ling +3 位作者 CHEN Keying HU Xiaofang XU Lisa X. FAN Chunhai 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第5期286-291,共6页
Secretome, the totality of secreted proteins, is viewed as a promising pool of candidate cancer biomarkers. Simple and reliable methods for identifying secreted proteins are highly desired. We used an optimized semi-s... Secretome, the totality of secreted proteins, is viewed as a promising pool of candidate cancer biomarkers. Simple and reliable methods for identifying secreted proteins are highly desired. We used an optimized semi-shotgun liquid chromatography followed by tandem mass spectrometry (LC-MS/MS) method to analyze the secretome of breast cancer cell line MDA-MB-231. A total of 464 proteins were identified. About 63% of the proteins were classified as secreted proteins, including many promising breast cancer biomarkers, which were thought to be correlated with tumorigenesis, tumor development and metastasis. These results suggest that the optimized method may be a powerful strategy for cell line secretome profiling, and can be used to find potential cancer biomarkers with great clinical significance. 展开更多
关键词 乳腺癌 癌细胞 放射性 化疗
下载PDF
NONLINEAR SCATTERING AND ATTENUATION OF FIRST SOUND IN SUPERFLUID ^(4)He AT HIGH FREQUENCY AND TEMPERATURE NEAR T_(λ)
4
作者 程建春 魏荣爵 《Chinese Physics Letters》 SCIE CAS 1988年第6期261-264,共4页
The attenuation coefficient of the impressed first sound due to the scattering of random background of the second sound is calculated.The result shows that this is an important factor which gives rise the attenuation ... The attenuation coefficient of the impressed first sound due to the scattering of random background of the second sound is calculated.The result shows that this is an important factor which gives rise the attenuation of the first sound in the vicinity of transition temperature T_(λ) at very high frequencies of GHz range.The predicted value agrees with the measured data in order of magnitude. 展开更多
关键词 MAGNITUDE VICINITY sound
原文传递
Single-Molecular Co-localization Detection and Analysis
5
作者 Mary D.WANG 《生物物理学报》 CAS CSCD 北大核心 2009年第S1期161-161,共1页
This talk will discuss single-molecule detection that shows on dual-color optical imaging data, image processing and statistical analysis can reliably differentiate random
关键词 SINGLE MOLECULE DETECTION CO-LOCALIZATION dual-color
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部