期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A Method for Measurement of the Hypertrophic First Metatarsal Medial Eminence on Foot Radiographs—A Reliability Study with Surgical Implications
1
作者 Paul S. Armanasco Kathy Briffa Nick Pang 《Journal of Analytical Sciences, Methods and Instrumentation》 2014年第1期31-37,共7页
Background: It has been suggested that hypertrophic eminence on the medial head of the first metatarsal is a component of the patho-anatomy of hallux valgus. However, research findings in this area are inconsistent, p... Background: It has been suggested that hypertrophic eminence on the medial head of the first metatarsal is a component of the patho-anatomy of hallux valgus. However, research findings in this area are inconsistent, possibly due to differences in methods in identifying and measuring the medial eminence. To date, reliability of any method of measurement has not been reported. The purpose of this study was to determine the reliability of measurement of the medial eminence on medial oblique and dorsoplantar radiographs using a previously described geometric technique. Methods: To evaluate the reliability of a method of measurement of the medial eminence of the first metatarsal duplicate standardized dorsoplantar and medial oblique radiographs were taken of one foot of 15 subjects. The feet included both rectus feet and subjects with hallux valgus. The medial eminence was measured on the digital images using Inteleviewer 2.5 (Intelerad medical systems incorporated, Montreal, Quebec) software. Observer 1 measured one randomly selected image from each subject to determine inter-observer reliability. Observer 2 measured all images to determine the overall intraobserver reliability. Reliability was calculated using intra-class correlation coefficients (ICC). Results: The mean projection of the medial eminence ranged from 0.39 to 0.44 cm in both views. The ICCs were calculated for the dorsoplantar view and the 2 medial oblique view measures between observers. They ranged from 0.76 intra-rater and 0.86 interrater in the dorsoplantar view to 0.80 intra-rater and 0.90 inter-rater in the medial oblique view indicating good reliability in all measures. The average of the 4 oblique views also showed a high level of reliability with a coefficient of 0.96. Conclusions: The medial eminence can be reliably measured in the medial oblique and dorsoplantar view using the described technique. The medial oblique and the dorsoplantar views are valuable and reliable projections for visualising the dorso medial aspect of the first metatarsal. 展开更多
关键词 HALLUX VALGUS MEDIAL Eminence RADIOGRAPH Surgery RELIABILITY
下载PDF
防止ESD引起器件闩锁的电源断路器
2
作者 Emerson segurat 《电子设计技术 EDN CHINA》 2005年第10期76-76,共1页
在某些情况下,ESD(静电放电)事件会毁坏数字电路,造成闩锁效应.例如,受到ESD触发时,通常构成CMOS器件中一部分的寄生晶体管会表现为一个SCR(可控硅整流器).一旦ESD触发,SCR会在CMOS器件的两部分之间形成一个低阻通道,并严重导电.除非立... 在某些情况下,ESD(静电放电)事件会毁坏数字电路,造成闩锁效应.例如,受到ESD触发时,通常构成CMOS器件中一部分的寄生晶体管会表现为一个SCR(可控硅整流器).一旦ESD触发,SCR会在CMOS器件的两部分之间形成一个低阻通道,并严重导电.除非立即切断电路的电源,否则器件就会被损坏.人体交互产生的ESD是手机和医疗设备中遇到的大问题.为了有足够的ESD防护,多数医疗设备和工业设备都需要为ESD电流设置一个接地回路.而在实际生活中,移动设备可以对付没有合适的电源接地引出线的使用环境. 展开更多
关键词 CMOS器件 ESD防护 电源接地 闩锁效应 断路器 防止 可控硅整流器 数字电路 医疗设备
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部