期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Mechanisms and clinical significance of quality of final kissing balloon inflation in patients with true bifurcation lesions treated by crush stenting technique 被引量:8
1
作者 ZHANG Jun-jie CHEN Shao-liang +8 位作者 YE Fei YANG Song KAN Jing LIU Yue-qiang ZHOU Yong SUN Xue-wen ZHANG Ai-ping WANG Xin CHEN Jack 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第18期2086-2091,共6页
Background The mechanisms responsible for the occurrence of a kissing unsatisfied (KUS) result after classical crush stenting remain unclear. The present study aimed at analyzing the mechanisms and clinical signific... Background The mechanisms responsible for the occurrence of a kissing unsatisfied (KUS) result after classical crush stenting remain unclear. The present study aimed at analyzing the mechanisms and clinical significance of KUS. Methods Two hundred and thirteen patients with true bifurcation lesions treated with classical crush stenting and final kissing balloon inflation (FKBI) were assigned to upper, middle, and lower groups according to the position of the side branch re-wiring assessed by visual estimation, quantitative coronary analysis (QCA) and intravascular ultrasound (IVUS). Angiographic follow-up was indexed at 12 months. Results The upper group was characterized by a larger bifurcation angle of 55.53°±25.25° (P=0,030) and a longer procedural time (42.43±23.92) minutes (P=0.015). The overall rate of KUS by visual estimation was 10.48%, with 5.4% in the upper group, 3.9% in middle group, and 36.1% in lower group (P 〈0.001). For the diagnosis of KUS, visual inspection demonstrated a good correlation with both QCA and IVUS. Smaller stent diameter was the main reason for KUS in the upper group, while extra-stent side wire location, or re-wire in a low position was the main mechanism attributed to KUS in the lower group. The Lower group had more restenosis, with most restenotic lesions at a lower position of the side branch ostium. KUS (HR 1.652, 95% Cl 1.332-2.088, P 〈0.001) and re-wiring position (HR 2.341, 95% Cl 1.780-4.329, P 〈0.001) were two independent predictors of side branch restenosis. Re-wiring position (OR 0.458, 95%C/0.336-0.874, P=0.001) and side stent expansion (OR 3.122, 95%C/2.883-5.061, P=0.014) were factors predicting the findings of KUS. Conclusions Side wire outside side stents resulted in more KUS and restenosis. Different restenotic lesion types reflected individual mechanisms contributing to the development of plaque proliferation. 展开更多
关键词 bifurcation lesions classical crush stenting kissing unsatisfied classification
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部