Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement trans...Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated.展开更多
An indium tin oxide(ITO) and silicon nitride(Si_(3)N_(4)) assisted compact TE-pass waveguide polarizer based on lithiumniobate-on-insulator is proposed and numerically analyzed.By properly designing the ITO and Si_(3)...An indium tin oxide(ITO) and silicon nitride(Si_(3)N_(4)) assisted compact TE-pass waveguide polarizer based on lithiumniobate-on-insulator is proposed and numerically analyzed.By properly designing the ITO and Si_(3)N_(4) assisted structure and utilizing the epsilon-near-zero effect of ITO,the TM mode is strongly confined in the ITO layer with extremely high loss,while the TE mode is hardly affected and passes through the waveguide with low loss.The simulation results show that the polarizer has an extinction ratio of 22.5 dB and an insertion loss of 0.8 dB at the wavelength of 1.55 μm,and has an operating bandwidth of about 125 nm(from 1540 nm to 1665 nm) for an extinction ratio of>20 dB and an insertion loss of<0.95 dB.Moreover,the proposed device exhibits large fabrication tolerances.More notably,the device is compact,with a length of only 7.5 μm,and is appropriate for on-chip applications.展开更多
A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achi...A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achieved.According to the model,a probe-type nano-modified fiber optic configurable plasmonic resonance(NMF-CPR)sensor with tip hot spot enhancement is demonstrated for the measurement of the refractive index in the range of 1.3332-1.3432 corresponding to the low-concentration biomarker solution.The new-type sensing structure avoids excessive broadening and redshift of the resonance dip,which provides more possibilities for the surface modification of other functional nanomaterials.The tip hot spots in nanogaps between the Au layer and Au nanostars(AuNSs),the tip electric field enhancement of AuNSs,and the high carrier mobility of the WSe_(2)layer synergistically and significantly enhance the sensitivity of the sensor.Ex-perimental results show that the sensitivity and the figure of merit of the tip hot spot enhanced fiber NMF-CPR sensor can achieve up to 2995.70 nm/RIU and 25.04 RIU^(−1),respectively,which are 1.68 times and 1.29 times higher than those of the conventional fiber plasmonic resonance sensor.The results achieve good agreements with numerical simulations,demonstrate a better level compared to similar reported studies,and verify the correctness of the dispersion model.The detection resolution of the sensor reaches up to 2.00×10^(−5)RIU,which is obviously higher than that of the conventional side-polished fiber plasmonic resonance sensor.This indicates a high detection accuracy of the sensor.The dense Au layer effectively prevents the intermediate nanomaterials from shedding and chemical degradation,which enables the sensor with high stability.Furthermore,the terminal reflective sensing structure can be used as a practical probe and can allow a more convenient operation.展开更多
Using hexagonal boron nitride(h-BN)to prepare resistive switching devices is a promising strategy.Various doping methods have aroused great interest in the semiconductor field in recent years,but many researchers have...Using hexagonal boron nitride(h-BN)to prepare resistive switching devices is a promising strategy.Various doping methods have aroused great interest in the semiconductor field in recent years,but many researchers have overlooked the various repetitive anomalies that occur during the testing process.In this study,the basic electrical properties and additive protrusion behavior of Ga-ion-doped h-BN memristors at micro–nanoscale during the voltage scanning process are investigated via atomic force microscopy(AFM)and energy dispersive spectroscopy.The additive protrusion behavior is subjected to exploratory research,and it is concluded that it is caused by anodic oxidation.An approach is proposed that involves filling the AFM chamber with nitrogen gas to improve the stability of memristor testing,and this method provides a solution for enhanced testing stability of memristors.展开更多
The wMPS is a laser-based measurement system used for large scale metrology.However,it is susceptible to external factors such as vibrations,which can lead to unreliable measurements.This paper presents a fault diagno...The wMPS is a laser-based measurement system used for large scale metrology.However,it is susceptible to external factors such as vibrations,which can lead to unreliable measurements.This paper presents a fault diagnosis and separation method which can counter this problem.To begin with,the paper uses simple models to explain the fault diagnosis and separation methods.These methods are then mathematically derived using statistical analysis and the principles of the wMPS.A comprehensive solution for fault diagnosis and separation is proposed,considering the characteristics of the wMPS.The effectiveness of this solution is verified through experimental observations.It can be concluded that this approach can detect and separate false observations,thereby enhancing the reliability of the wMPS.展开更多
Passively mode-locked fiber lasers emit femtosecond pulse trains with excellent short-term stability. The quantum-limited timing jitter of a free running femtosecond erbium-doped fiber laser working at room temperatur...Passively mode-locked fiber lasers emit femtosecond pulse trains with excellent short-term stability. The quantum-limited timing jitter of a free running femtosecond erbium-doped fiber laser working at room temperature is considerably below one femtosecond at high Fourier frequency. The ultrashort pulse train with ultralow timing jitter enables absolute time-of-flight measurements based on a dual-comb implementation, which is typically composed of a pair of optical frequency combs generated by femtosecond lasers. Dead-zone-free absolute distance measurement with sub-micrometer precision and kHz update rate has been routinely achieved with a dual-comb configuration, which is promising for a number of precision manufacturing applications, from large step-structure measurements prevalent in microelectronic profilometry to three coordinate measurements in large-scale aerospace manufacturing and shipbuilding. In this paper, we first review the sub-femtosecond precision timing jitter characterization methods and approaches for ultralow timing jitter mode-locked fiber laser design. Then, we provide an overview of the state-of-the-art dual-comb absolute ranging technology in terms of working principles, experimental implementations, and measurement precisions. Finally, we discuss the impact of quantum-limited timing jitter on the dual-comb ranging precision at a high update rate. The route to highprecision dual-comb range finder design based on ultralow jitter femtosecond fiber lasers is proposed.展开更多
If a metalens integrates the circular polarization(CP)conversion function,the focusing lens together with circular-polariz-ing lens(CPL)in traditional cameras may be replaced by a metalens.However,in terahertz(THz)ban...If a metalens integrates the circular polarization(CP)conversion function,the focusing lens together with circular-polariz-ing lens(CPL)in traditional cameras may be replaced by a metalens.However,in terahertz(THz)band,the reported metalenses still do not obtain the perfect and strict single-handed CP,because they were constructed via Pancharatnam-Berry phase so that CP conversion contained both left-handed CP(LCP)and right-handed CP(RCP)components.In this paper,a silicon based THz metalens is constructed using dynamic phase to obtain single-handed CP conversion.Also,we can rotate the whole metalens at a certain angle to control the conversion of multi-polarization states,which can simply manipulate the focusing for incident linear polarization(LP)THz wave in three polarization conversion states,in-cluding LP without conversion,LCP and RCP.Moreover,the polarization conversion behavior is reversible,that is,the THz metalens can convert not only the LP into arbitrary single-handed CP,but also the LCP and RCP into two perpen-dicular LP,respectively.The metalens is expected to be used in advanced THz camera,as a great candidate for tradi-tional CPL and focusing lens group,and also shows potential application in polarization imaging with discriminating LCP and RCP.展开更多
Speech signals in frequency domain were separated based on discrete wavelet transform (DWT) and independent component analysis (ICA). First, mixed speech signals were decomposed into different frequency domains by DWT...Speech signals in frequency domain were separated based on discrete wavelet transform (DWT) and independent component analysis (ICA). First, mixed speech signals were decomposed into different frequency domains by DWT and the subbands of speech signals were separated using ICA in each wavelet domain; then, the permutation and scaling problems of frequency domain blind source separation (BSS) were solved by utilizing the correlation between adjacent bins in speech signals; at last, source signals were reconstructed from single branches. Experiments were carried out with 2 sources and 6 microphones using speech signals at sampling rate of 40 kHz. The microphones were aligned with 2 sources in front of them, on the left and right. The separation of one male and one female speeches lasted 2.5 s. It is proved that the new method is better than single ICA method and the signal to noise ratio is improved by 1 dB approximately.展开更多
In the proposed system for online inspection of steel balls, a diffuse illumination is developed to enhance defect appearances and produce high quality images. To fully view the entire sphere, a novel unfolding method...In the proposed system for online inspection of steel balls, a diffuse illumination is developed to enhance defect appearances and produce high quality images. To fully view the entire sphere, a novel unfolding method is put forward based on geometrical analysis, which only requires one-dimensional movement of the balls and a pair of cameras to capture images from different directions. Moreover, a realtime inspection algorithm is customized to improve both accuracy and efficiency. The precision and recall of the sample set were 87.7% and 98%, respectively. The average time cost on image processing and analysis for a steel ball was 47 ms, and the total time cost was less than 200 ms plus the cost of image acquisition and balls' movement. The system can sort 18 000 balls per hour with a spatial resolution higher than 0.01 mm.展开更多
A discrimination measurement method and demodulation technique for fiber Bragg grating (FBG) sensors were presented using digital filtering technique. The system can control a tunable fiber Fabry-Perot filter with saw...A discrimination measurement method and demodulation technique for fiber Bragg grating (FBG) sensors were presented using digital filtering technique. The system can control a tunable fiber Fabry-Perot filter with sawtooth wave voltage generated by digital clock to interrogate FBG sensors. Using the analogue digital converter (ADC), the reflected FBG signals were sampled with synchronous digital clock. With the aid of digital matched filtering technique, the sampled FBG signals were processed to obtain the maximum signal-to-noise ratio (SNR) and the Bragg wavelength shift from the FBG signals was recovered. The results demonstrate that this system has a scanning range of 1 520 nm-1 575 nm,and the wavelength detection accuracy is less than 2 pm with 1.5 Hz scanning frequency.展开更多
The parallel spectral-domain optical coherence tomography(PSDOCT) is described for high-speed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) int...The parallel spectral-domain optical coherence tomography(PSDOCT) is described for high-speed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional OCT and complex Fourier-domain optical coherence tomography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.展开更多
A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, ...A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional micro-adjusting mechanism to realize the precise positioning. By LabView software this system is controlled to run automatically, to carry out calibration and automatic data collection, and to make data import into the database directly. Experiments proved that the diameter measurement range of the system can be 1.8 mm—7 mm, the resolution can be up to 5 nm—10 nm, the repeatability measurement standard deviation can be 0.05 μm—0.1 μm, and the measurement uncertainty can achieve 0.15 μm—0.3 μm. So the measuring system can realize the nanometer-level measurement.展开更多
Transition metal dichalcogenides(TMDCs) belong to a subgroup of two-dimensional(2 D) materials which usually possess thickness-dependent band structures and semiconducting properties. Therefore, for TMDCs to be widely...Transition metal dichalcogenides(TMDCs) belong to a subgroup of two-dimensional(2 D) materials which usually possess thickness-dependent band structures and semiconducting properties. Therefore, for TMDCs to be widely used in electronic and optoelectronic applications, two critical issues need to be addressed, which are thickness-controllable fabrication and doping modulation of TMDCs. In this work, we successfully obtained monolayer WS2 and achieved its efficient doping by chemical vapor deposition and chemical doping, respectively. The n-and p-type dopings of the monolayer WS2 were achieved by drop coating electron donor and acceptor solutions of triphenylphosphine(PPh3) and gold chloride(AuCl_3), respectively, on the surface, which donates and captures electrons to/from the WS2 surface through charge transfer, respectively. Both doping effects were investigated in terms of the electrical properties of the fabricated field effect transistors. After chemical doping, the calculated mobility and density of electrons/holes are around 74.6/39.5 cm^2 · V^(-1) ·s^(-1)and 1.0 x 10^(12)/4.2 x 10^(11) cm^(-2), respectively. Moreover, we fabricated a lateral WS2 p-n homojunction consisting of nondoped n-type and p-doped p-type regions, which showed great potential for photodetection with a response time of 1.5 s and responsivity of 5.8 A/W at V_G = 0 V and V_D = 1 V under 532 nm light illumination.展开更多
In this paper, a flexible high-precision calibration method suitable for industrial field was proposed. The complexity of the coordinate transformation was simplified by choosing the camera coordinate system as the un...In this paper, a flexible high-precision calibration method suitable for industrial field was proposed. The complexity of the coordinate transformation was simplified by choosing the camera coordinate system as the unified reference coordinate system. A flexible planar calibration pattern was introduced to the calibration process, which can be arbitrarily placed and from which the known feature points can be extracted to construct other unknown feature points. With the known intrinsic parameters, the laser projector plane equation was fitted by the multi-noncollinear points, which were acquired through the principle of triangulation and the projective invariance of cross ratio. With this method, the strict alignment and multiple times of coordinate transformation can be avoided. Experimental results showed that the arithmetic mean of the root mean square(RMS) error of distance was 0.000 7 mm.展开更多
A brain-computer interface(BCI)-based electric wheelchair control system was developed, which enables the users to move the wheelchair forward or backward, and turn left or right without any pre-learning. This control...A brain-computer interface(BCI)-based electric wheelchair control system was developed, which enables the users to move the wheelchair forward or backward, and turn left or right without any pre-learning. This control system makes use of the amplitude enhancement of alpha-wave blocking in electroencephalogram(EEG) when eyes close for more than 1 s to constitute a BCI for the switch control of wheelchair movements. The system was formed by BCI control panel, data acquisition, signal processing unit and interface control circuit. Eight volunteers participated in the wheelchair control experiments according to the preset routes. The experimental results show that the mean success control rate of all the subjects was 81.3%, with the highest reaching 93.7%. When one subject's triggering time was 2.8 s, i.e., the flashing time of each cycle light was 2.8 s, the average information transfer rate was 8.10 bit/min, with the highest reaching 12.54 bit/min.展开更多
To sharpen the imaging of structures, it is vital to develop a convenient and efficient quantitative algorithm of the optical coherence tomography (OCT) sampling. In this paper a new Monte Carlo model is set up and ho...To sharpen the imaging of structures, it is vital to develop a convenient and efficient quantitative algorithm of the optical coherence tomography (OCT) sampling. In this paper a new Monte Carlo model is set up and how light propagates in bio-tissue is analyzed in virtue of mathematics and physics equations. The relations,in which light intensity of Class 1 and Class 2 light with different wavelengths changes with their permeation depth,and in which Class 1 light intensity (signal light intensity) changes with the probing depth, and in which angularly resolved diffuse reflectance and diffuse transmittance change with the exiting angle, are studied. The results show that Monte Carlo simulation results are consistent with the theory data.展开更多
Based on the effective structure of the self-mixing interference effects,a general model for the self-mixing interference effects in the LD pumped solid-state laser has been established for the first time.The numerica...Based on the effective structure of the self-mixing interference effects,a general model for the self-mixing interference effects in the LD pumped solid-state laser has been established for the first time.The numerical simulation of the self-mixing interference signal has been done,the results show that when the external cavity length is integral times of 1/2,1/3,2/3,1/4,3/4 of the effective cavity length,the intensity of the self-mixing interference signals reach maximum in value.While that of single mode laser is integral times of half of the effective cavity length,the measuring precision of displacement of single mode laser is λ/2.A conclusion can be drawn from the above results that the measuring precision of displacement of multi-mode laser is higher than that of single mode laser.展开更多
A new method to detect multiple outliers in multivariate data is proposed. It is a combination of minimum subsets, resampling and self-organizing map (SOM) algorithm introduced by Kohonen,which provides a robust way w...A new method to detect multiple outliers in multivariate data is proposed. It is a combination of minimum subsets, resampling and self-organizing map (SOM) algorithm introduced by Kohonen,which provides a robust way with neural network. In this method, the number and organization of the neurons are selected by the characteristics of the spectra, e.g., the spectra data are often changed linearly with the concentration of the components and are often measured repeatedly, etc. So the spatial distribution of the neurons can be arranged by this characteristic. With this method, all the outliers in the spectra can be detected, which cannot be solved by the traditional method, and the speed of computation is higher than that of the traditional neural network method. The results of the simulation and the experiment show that this method is simple, effective, intuitionistic and all the outliers in the spectra can be detected in a short time. It is useful when associated with the regression model in the near infra-red research.展开更多
Graphene and transition metal dichalcogenides(TMDs), two-dimensional materials, have been investigated wildely in recent years. As a member of the TMD family, MoTe2 possesses a suitable bandgap of ~1.0 eV for near inf...Graphene and transition metal dichalcogenides(TMDs), two-dimensional materials, have been investigated wildely in recent years. As a member of the TMD family, MoTe2 possesses a suitable bandgap of ~1.0 eV for near infrared(NIR)photodetection. Here we stack the MoTe2 flake with two graphene flakes of high carrier mobility to form a graphene–MoTe2–graphene heterostructure. It exhibits high photo-response to a broad spectrum range from 500 nm to 1300 nm. The photoresponsivity is calculated to be 1.6 A/W for the 750-nm light under 2 V/0 V drain–source/gate bias, and 154 mA/W for the 1100-nm light under 0.5 V/60 V drain–source/gate bias. Besides, the polarity of the photocurrent under zero Vds can be efficiently tuned by the back gate voltage to satisfy different applications. Finally, we fabricate a vertical graphene–MoTe2–graphene heterostructure which shows improved photoresponsivity of 3.3 A/W to visible light.展开更多
基金supported financially by the National Natural Science Foundation of China (NSFC) (Grant No.51775378)the Key Projects in Tianjin Science&Technology Support Program (Grant No.19YFZC GX00890).
文摘Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated.
基金Project supported by the National Natural Science Foundation of China (Grant No. 61875148)。
文摘An indium tin oxide(ITO) and silicon nitride(Si_(3)N_(4)) assisted compact TE-pass waveguide polarizer based on lithiumniobate-on-insulator is proposed and numerically analyzed.By properly designing the ITO and Si_(3)N_(4) assisted structure and utilizing the epsilon-near-zero effect of ITO,the TM mode is strongly confined in the ITO layer with extremely high loss,while the TE mode is hardly affected and passes through the waveguide with low loss.The simulation results show that the polarizer has an extinction ratio of 22.5 dB and an insertion loss of 0.8 dB at the wavelength of 1.55 μm,and has an operating bandwidth of about 125 nm(from 1540 nm to 1665 nm) for an extinction ratio of>20 dB and an insertion loss of<0.95 dB.Moreover,the proposed device exhibits large fabrication tolerances.More notably,the device is compact,with a length of only 7.5 μm,and is appropriate for on-chip applications.
基金financial supports from in part by National Natural Science Foundation of China under Grants 61922061, 61775161 and 61735011in part by the Tianjin Science Fund for Distinguished Young Scholars under Grant 19JCJQJC61400
文摘A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achieved.According to the model,a probe-type nano-modified fiber optic configurable plasmonic resonance(NMF-CPR)sensor with tip hot spot enhancement is demonstrated for the measurement of the refractive index in the range of 1.3332-1.3432 corresponding to the low-concentration biomarker solution.The new-type sensing structure avoids excessive broadening and redshift of the resonance dip,which provides more possibilities for the surface modification of other functional nanomaterials.The tip hot spots in nanogaps between the Au layer and Au nanostars(AuNSs),the tip electric field enhancement of AuNSs,and the high carrier mobility of the WSe_(2)layer synergistically and significantly enhance the sensitivity of the sensor.Ex-perimental results show that the sensitivity and the figure of merit of the tip hot spot enhanced fiber NMF-CPR sensor can achieve up to 2995.70 nm/RIU and 25.04 RIU^(−1),respectively,which are 1.68 times and 1.29 times higher than those of the conventional fiber plasmonic resonance sensor.The results achieve good agreements with numerical simulations,demonstrate a better level compared to similar reported studies,and verify the correctness of the dispersion model.The detection resolution of the sensor reaches up to 2.00×10^(−5)RIU,which is obviously higher than that of the conventional side-polished fiber plasmonic resonance sensor.This indicates a high detection accuracy of the sensor.The dense Au layer effectively prevents the intermediate nanomaterials from shedding and chemical degradation,which enables the sensor with high stability.Furthermore,the terminal reflective sensing structure can be used as a practical probe and can allow a more convenient operation.
基金supported by the Youth Fund of the National Natural Science Foundation of China(Grant No.622041701004267).
文摘Using hexagonal boron nitride(h-BN)to prepare resistive switching devices is a promising strategy.Various doping methods have aroused great interest in the semiconductor field in recent years,but many researchers have overlooked the various repetitive anomalies that occur during the testing process.In this study,the basic electrical properties and additive protrusion behavior of Ga-ion-doped h-BN memristors at micro–nanoscale during the voltage scanning process are investigated via atomic force microscopy(AFM)and energy dispersive spectroscopy.The additive protrusion behavior is subjected to exploratory research,and it is concluded that it is caused by anodic oxidation.An approach is proposed that involves filling the AFM chamber with nitrogen gas to improve the stability of memristor testing,and this method provides a solution for enhanced testing stability of memristors.
文摘The wMPS is a laser-based measurement system used for large scale metrology.However,it is susceptible to external factors such as vibrations,which can lead to unreliable measurements.This paper presents a fault diagnosis and separation method which can counter this problem.To begin with,the paper uses simple models to explain the fault diagnosis and separation methods.These methods are then mathematically derived using statistical analysis and the principles of the wMPS.A comprehensive solution for fault diagnosis and separation is proposed,considering the characteristics of the wMPS.The effectiveness of this solution is verified through experimental observations.It can be concluded that this approach can detect and separate false observations,thereby enhancing the reliability of the wMPS.
基金supported by National Natural Science Foundation of China (Grant Nos.61475162,61675150,and 61535009)Tianjin Natural Science Foundation (Grant No.18JCYBJC16900)Tianjin Research Program of Application Foundation and Advanced Technology (Grant No.17JCJQJC43500)
文摘Passively mode-locked fiber lasers emit femtosecond pulse trains with excellent short-term stability. The quantum-limited timing jitter of a free running femtosecond erbium-doped fiber laser working at room temperature is considerably below one femtosecond at high Fourier frequency. The ultrashort pulse train with ultralow timing jitter enables absolute time-of-flight measurements based on a dual-comb implementation, which is typically composed of a pair of optical frequency combs generated by femtosecond lasers. Dead-zone-free absolute distance measurement with sub-micrometer precision and kHz update rate has been routinely achieved with a dual-comb configuration, which is promising for a number of precision manufacturing applications, from large step-structure measurements prevalent in microelectronic profilometry to three coordinate measurements in large-scale aerospace manufacturing and shipbuilding. In this paper, we first review the sub-femtosecond precision timing jitter characterization methods and approaches for ultralow timing jitter mode-locked fiber laser design. Then, we provide an overview of the state-of-the-art dual-comb absolute ranging technology in terms of working principles, experimental implementations, and measurement precisions. Finally, we discuss the impact of quantum-limited timing jitter on the dual-comb ranging precision at a high update rate. The route to highprecision dual-comb range finder design based on ultralow jitter femtosecond fiber lasers is proposed.
基金supported by the National Natural Science Foundation of China(Nos.61675147,61735010 and 91838301)National Key Research and Development Program of China(No.2017YFA0700202)Basic Re-search Program of Shenzhen(JCYJ20170412154447469).
文摘If a metalens integrates the circular polarization(CP)conversion function,the focusing lens together with circular-polariz-ing lens(CPL)in traditional cameras may be replaced by a metalens.However,in terahertz(THz)band,the reported metalenses still do not obtain the perfect and strict single-handed CP,because they were constructed via Pancharatnam-Berry phase so that CP conversion contained both left-handed CP(LCP)and right-handed CP(RCP)components.In this paper,a silicon based THz metalens is constructed using dynamic phase to obtain single-handed CP conversion.Also,we can rotate the whole metalens at a certain angle to control the conversion of multi-polarization states,which can simply manipulate the focusing for incident linear polarization(LP)THz wave in three polarization conversion states,in-cluding LP without conversion,LCP and RCP.Moreover,the polarization conversion behavior is reversible,that is,the THz metalens can convert not only the LP into arbitrary single-handed CP,but also the LCP and RCP into two perpen-dicular LP,respectively.The metalens is expected to be used in advanced THz camera,as a great candidate for tradi-tional CPL and focusing lens group,and also shows potential application in polarization imaging with discriminating LCP and RCP.
基金Supported by Tianjin Municipal Science and Technology Commission (No.09JCYBJC02200)
文摘Speech signals in frequency domain were separated based on discrete wavelet transform (DWT) and independent component analysis (ICA). First, mixed speech signals were decomposed into different frequency domains by DWT and the subbands of speech signals were separated using ICA in each wavelet domain; then, the permutation and scaling problems of frequency domain blind source separation (BSS) were solved by utilizing the correlation between adjacent bins in speech signals; at last, source signals were reconstructed from single branches. Experiments were carried out with 2 sources and 6 microphones using speech signals at sampling rate of 40 kHz. The microphones were aligned with 2 sources in front of them, on the left and right. The separation of one male and one female speeches lasted 2.5 s. It is proved that the new method is better than single ICA method and the signal to noise ratio is improved by 1 dB approximately.
文摘In the proposed system for online inspection of steel balls, a diffuse illumination is developed to enhance defect appearances and produce high quality images. To fully view the entire sphere, a novel unfolding method is put forward based on geometrical analysis, which only requires one-dimensional movement of the balls and a pair of cameras to capture images from different directions. Moreover, a realtime inspection algorithm is customized to improve both accuracy and efficiency. The precision and recall of the sample set were 87.7% and 98%, respectively. The average time cost on image processing and analysis for a steel ball was 47 ms, and the total time cost was less than 200 ms plus the cost of image acquisition and balls' movement. The system can sort 18 000 balls per hour with a spatial resolution higher than 0.01 mm.
基金Doctoral Foundation of Ministry of Education of China (No. 20040056008)
文摘A discrimination measurement method and demodulation technique for fiber Bragg grating (FBG) sensors were presented using digital filtering technique. The system can control a tunable fiber Fabry-Perot filter with sawtooth wave voltage generated by digital clock to interrogate FBG sensors. Using the analogue digital converter (ADC), the reflected FBG signals were sampled with synchronous digital clock. With the aid of digital matched filtering technique, the sampled FBG signals were processed to obtain the maximum signal-to-noise ratio (SNR) and the Bragg wavelength shift from the FBG signals was recovered. The results demonstrate that this system has a scanning range of 1 520 nm-1 575 nm,and the wavelength detection accuracy is less than 2 pm with 1.5 Hz scanning frequency.
文摘The parallel spectral-domain optical coherence tomography(PSDOCT) is described for high-speed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional OCT and complex Fourier-domain optical coherence tomography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.
文摘A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional micro-adjusting mechanism to realize the precise positioning. By LabView software this system is controlled to run automatically, to carry out calibration and automatic data collection, and to make data import into the database directly. Experiments proved that the diameter measurement range of the system can be 1.8 mm—7 mm, the resolution can be up to 5 nm—10 nm, the repeatability measurement standard deviation can be 0.05 μm—0.1 μm, and the measurement uncertainty can achieve 0.15 μm—0.3 μm. So the measuring system can realize the nanometer-level measurement.
基金Project supported by the National Natural Science Foundation of China(Grant No.21405109)Seed Foundation of State Key Laboratory of Precision Measurement Technology and Instruments,China(Grant No.1710)
文摘Transition metal dichalcogenides(TMDCs) belong to a subgroup of two-dimensional(2 D) materials which usually possess thickness-dependent band structures and semiconducting properties. Therefore, for TMDCs to be widely used in electronic and optoelectronic applications, two critical issues need to be addressed, which are thickness-controllable fabrication and doping modulation of TMDCs. In this work, we successfully obtained monolayer WS2 and achieved its efficient doping by chemical vapor deposition and chemical doping, respectively. The n-and p-type dopings of the monolayer WS2 were achieved by drop coating electron donor and acceptor solutions of triphenylphosphine(PPh3) and gold chloride(AuCl_3), respectively, on the surface, which donates and captures electrons to/from the WS2 surface through charge transfer, respectively. Both doping effects were investigated in terms of the electrical properties of the fabricated field effect transistors. After chemical doping, the calculated mobility and density of electrons/holes are around 74.6/39.5 cm^2 · V^(-1) ·s^(-1)and 1.0 x 10^(12)/4.2 x 10^(11) cm^(-2), respectively. Moreover, we fabricated a lateral WS2 p-n homojunction consisting of nondoped n-type and p-doped p-type regions, which showed great potential for photodetection with a response time of 1.5 s and responsivity of 5.8 A/W at V_G = 0 V and V_D = 1 V under 532 nm light illumination.
基金Supported by the National Natural Science Foundation of China(No.51105273)
文摘In this paper, a flexible high-precision calibration method suitable for industrial field was proposed. The complexity of the coordinate transformation was simplified by choosing the camera coordinate system as the unified reference coordinate system. A flexible planar calibration pattern was introduced to the calibration process, which can be arbitrarily placed and from which the known feature points can be extracted to construct other unknown feature points. With the known intrinsic parameters, the laser projector plane equation was fitted by the multi-noncollinear points, which were acquired through the principle of triangulation and the projective invariance of cross ratio. With this method, the strict alignment and multiple times of coordinate transformation can be avoided. Experimental results showed that the arithmetic mean of the root mean square(RMS) error of distance was 0.000 7 mm.
基金Supported by the National Natural Science Foundation of China(No.81222021,No.30970875,No.90920015,No.61172008 and No.81171423)National Key Technology Research and Development Program of the Ministry of Science and Technology of China(No.2012BAI34B02)Program for New Century Excellent Talents in University of the Ministry of Education of China(No.NCET-10-0618)
文摘A brain-computer interface(BCI)-based electric wheelchair control system was developed, which enables the users to move the wheelchair forward or backward, and turn left or right without any pre-learning. This control system makes use of the amplitude enhancement of alpha-wave blocking in electroencephalogram(EEG) when eyes close for more than 1 s to constitute a BCI for the switch control of wheelchair movements. The system was formed by BCI control panel, data acquisition, signal processing unit and interface control circuit. Eight volunteers participated in the wheelchair control experiments according to the preset routes. The experimental results show that the mean success control rate of all the subjects was 81.3%, with the highest reaching 93.7%. When one subject's triggering time was 2.8 s, i.e., the flashing time of each cycle light was 2.8 s, the average information transfer rate was 8.10 bit/min, with the highest reaching 12.54 bit/min.
文摘To sharpen the imaging of structures, it is vital to develop a convenient and efficient quantitative algorithm of the optical coherence tomography (OCT) sampling. In this paper a new Monte Carlo model is set up and how light propagates in bio-tissue is analyzed in virtue of mathematics and physics equations. The relations,in which light intensity of Class 1 and Class 2 light with different wavelengths changes with their permeation depth,and in which Class 1 light intensity (signal light intensity) changes with the probing depth, and in which angularly resolved diffuse reflectance and diffuse transmittance change with the exiting angle, are studied. The results show that Monte Carlo simulation results are consistent with the theory data.
文摘Based on the effective structure of the self-mixing interference effects,a general model for the self-mixing interference effects in the LD pumped solid-state laser has been established for the first time.The numerical simulation of the self-mixing interference signal has been done,the results show that when the external cavity length is integral times of 1/2,1/3,2/3,1/4,3/4 of the effective cavity length,the intensity of the self-mixing interference signals reach maximum in value.While that of single mode laser is integral times of half of the effective cavity length,the measuring precision of displacement of single mode laser is λ/2.A conclusion can be drawn from the above results that the measuring precision of displacement of multi-mode laser is higher than that of single mode laser.
文摘A new method to detect multiple outliers in multivariate data is proposed. It is a combination of minimum subsets, resampling and self-organizing map (SOM) algorithm introduced by Kohonen,which provides a robust way with neural network. In this method, the number and organization of the neurons are selected by the characteristics of the spectra, e.g., the spectra data are often changed linearly with the concentration of the components and are often measured repeatedly, etc. So the spatial distribution of the neurons can be arranged by this characteristic. With this method, all the outliers in the spectra can be detected, which cannot be solved by the traditional method, and the speed of computation is higher than that of the traditional neural network method. The results of the simulation and the experiment show that this method is simple, effective, intuitionistic and all the outliers in the spectra can be detected in a short time. It is useful when associated with the regression model in the near infra-red research.
基金Project supported by the National Natural Science Foundation of China(Grant No.21405109)the Seed Foundation of State Key Laboratory of Precision Measurement Technology and Instruments,China(Pilt No.1710)
文摘Graphene and transition metal dichalcogenides(TMDs), two-dimensional materials, have been investigated wildely in recent years. As a member of the TMD family, MoTe2 possesses a suitable bandgap of ~1.0 eV for near infrared(NIR)photodetection. Here we stack the MoTe2 flake with two graphene flakes of high carrier mobility to form a graphene–MoTe2–graphene heterostructure. It exhibits high photo-response to a broad spectrum range from 500 nm to 1300 nm. The photoresponsivity is calculated to be 1.6 A/W for the 750-nm light under 2 V/0 V drain–source/gate bias, and 154 mA/W for the 1100-nm light under 0.5 V/60 V drain–source/gate bias. Besides, the polarity of the photocurrent under zero Vds can be efficiently tuned by the back gate voltage to satisfy different applications. Finally, we fabricate a vertical graphene–MoTe2–graphene heterostructure which shows improved photoresponsivity of 3.3 A/W to visible light.