Introduction: Our study focused on the evaluation of renal function in children with sickle cell disease compared to children without sickle cell disease at the pediatric emergency unit of the Donka National Hospital ...Introduction: Our study focused on the evaluation of renal function in children with sickle cell disease compared to children without sickle cell disease at the pediatric emergency unit of the Donka National Hospital and SOS Drepano-Guinea center. Patients and Methods: This was a cross-sectional descriptive and analytical study lasting 3 months (October 1 to December 31, 2020). Were included, all sickle cell and non-sickle cell children aged 0 to 15 received on an outpatient basis and had undergone an exploration of renal function (serum creatinine and urine dipstick). Results: We performed the urine dipstick and serum creatinine in 75 children, 45 of whom were sickle cell and 30 were not sickle cell. 27 of our patients or 36% had a reduction in GFR, among them 9 or 20% were sickle cell and 18 or 60% were not sickle cell. The most affected age group was 5 to 9 years in sickle cell (66.7%) and non-sickle cell (38.9%). In sickle cell patients, 9 cases (100%) had mild renal failure (IRL). Non-sickle cell patients, had 14 cases or 77.8% of IRL and 4 cases (22.2%) of moderate IR. Sickle cell disease and antibiotics which had the respective p-value (0.01);(0.02), were statistically significant with the onset of renal failure. Conclusion: Several factors including sickle cell anemia and antibiotics are believed to be involved in lowering GFR. It would be essential to detect early the children received in consultation.展开更多
We report on a mid-infrared fiber laser that uses a single-walled carbon nanotube saturable absorber mirror to realize the mode-locking operation.The laser generates 3.5 μm ultra-short pulses from an erbium-doped flu...We report on a mid-infrared fiber laser that uses a single-walled carbon nanotube saturable absorber mirror to realize the mode-locking operation.The laser generates 3.5 μm ultra-short pulses from an erbium-doped fluoride fiber by utilizing a dual-wavelength pumping scheme.Stable mode-locking is achieved at the 3.5 μm band with a repetition rate of 25.2 MHz.The maximum average power acquired from the laser in the mode-locking regime is 25 mW.The experimental results indicate that the carbon nanotube is an effective saturable absorber for mode-locking in the mid-infrared spectral region.展开更多
文摘Introduction: Our study focused on the evaluation of renal function in children with sickle cell disease compared to children without sickle cell disease at the pediatric emergency unit of the Donka National Hospital and SOS Drepano-Guinea center. Patients and Methods: This was a cross-sectional descriptive and analytical study lasting 3 months (October 1 to December 31, 2020). Were included, all sickle cell and non-sickle cell children aged 0 to 15 received on an outpatient basis and had undergone an exploration of renal function (serum creatinine and urine dipstick). Results: We performed the urine dipstick and serum creatinine in 75 children, 45 of whom were sickle cell and 30 were not sickle cell. 27 of our patients or 36% had a reduction in GFR, among them 9 or 20% were sickle cell and 18 or 60% were not sickle cell. The most affected age group was 5 to 9 years in sickle cell (66.7%) and non-sickle cell (38.9%). In sickle cell patients, 9 cases (100%) had mild renal failure (IRL). Non-sickle cell patients, had 14 cases or 77.8% of IRL and 4 cases (22.2%) of moderate IR. Sickle cell disease and antibiotics which had the respective p-value (0.01);(0.02), were statistically significant with the onset of renal failure. Conclusion: Several factors including sickle cell anemia and antibiotics are believed to be involved in lowering GFR. It would be essential to detect early the children received in consultation.
基金supported by the National Natural Science Foundation of China (NSFC) (Nos. 61975136, 61935014, 61775146, and 61905151)Guangdong Basic and Applied Basic Research Foundation (No. 2019A1515010699)+2 种基金Shenzhen Science and Technology Project (Nos. JCYJ20160520161351540, JCYJ20170817100639177,JCYJ20170302151146995, JCYJ20180305125352956,JCYJ20160328144942069,and JCYJ20190808141011530)State Key Laboratory of Information Photonics and Optical Communications (No. IPOC2019ZZ01)State Key Laboratory of Pulsed Power Laser Technology (No. SKL2018KF04)
文摘We report on a mid-infrared fiber laser that uses a single-walled carbon nanotube saturable absorber mirror to realize the mode-locking operation.The laser generates 3.5 μm ultra-short pulses from an erbium-doped fluoride fiber by utilizing a dual-wavelength pumping scheme.Stable mode-locking is achieved at the 3.5 μm band with a repetition rate of 25.2 MHz.The maximum average power acquired from the laser in the mode-locking regime is 25 mW.The experimental results indicate that the carbon nanotube is an effective saturable absorber for mode-locking in the mid-infrared spectral region.