期刊文献+
共找到27篇文章
< 1 2 >
每页显示 20 50 100
Development of Optimal Structural System for Hybrid Cable-Stayed Bridges Using Ultra High Performance Concrete 被引量:1
1
作者 Hee Seok Kim Young Jin Kim +1 位作者 Won Jong Chin Hyejin Yoon 《Engineering(科研)》 2013年第9期720-728,共9页
This study developed an optimal structural system for the hybrid cable-stayed bridge expected to have a durable lifetime of 200 years and of which major structural members are made of ultra high performance concrete (... This study developed an optimal structural system for the hybrid cable-stayed bridge expected to have a durable lifetime of 200 years and of which major structural members are made of ultra high performance concrete (UHPC) with 200 MPa-class compressive strength. This innovative cable-stayed bridge system makes it possible to reduce each of the construction and maintenance costs by 20% compared to the conventional concrete cable-stayed bridge by improving significantly the weight and durability of the bridge. Therefore, detail design is carried out considering a real 800 m cable-stayed bridge and the optimal structure of the hybrid cable-stayed bridge is proposed and verified. 展开更多
关键词 HYBRID CABLE-STAYED Bridge Ultra High Performance Concrete (UHPC) OPTIMAL Structural System DURABILITY
下载PDF
Twin lintel belt in steel for seismic strengthening of brick masonry buildings 被引量:2
2
作者 C.V.R.Murty Jayanta Dutta S.K.Agrawal 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2004年第2期215-222,共8页
A single-room, single-storey full-scale brick masonry building with precast RC roofing system was tested thrice under displacement controlled lateral cyclic loading, to assess the effectiveness of the basic repair and... A single-room, single-storey full-scale brick masonry building with precast RC roofing system was tested thrice under displacement controlled lateral cyclic loading, to assess the effectiveness of the basic repair and seismic strengthening techniques. Initially, the virgin building specimen was loaded laterally to failure. In the second stage, the damaged building was repaired by stitching across the cracks, and tested under the same lateral loading. In the third stage, the twice-damaged structure was repaired once more by stitching and strengthened by twin lintel belt in steel and vertical comer reinforcement,and re-tested. The building strengthened by twin lintel belt in steel showed about 28% higher strength under lateral loading than the virgin building. 展开更多
关键词 双梁带 地震加固 砖砌圬工建筑 准静态滚动循环载荷 抗震设计
下载PDF
Dynamic Characteristics Evaluation of Innovative UHPC Pedestrian Cable Stayed Bridge 被引量:5
3
作者 Won Jong Chin Young Jin Kim +1 位作者 Jeong-Rae Cho Jong Sup Park 《Engineering(科研)》 2012年第12期869-876,共8页
KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and... KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and main- tenance costs of long-span bridges by 20% and double their lifetime through the exploitation of ultra-high performance concrete (UHPC). This paper presents the design and construction of the first pedestrian cable stayed bridge using UHPC developed by KICT. UHPC, compared to conventional concrete, has not only high compressive and tensile strengths but also high ductility. The UHPC developed at KICT is a steel fiber-reinforced cement compound presenting design compressive strength larger than 180 MPa and design tensile strength exceeding 10 MPa with water-to-binder ratio below 0.24 and admixing of 2 volume percentage of steel fiber. To show the applicability of UHPC to structures, a pedestrian cable stayed bridge (Super Bridge I) exploiting the characteristics of the developed UHPC has been planned, designed and erected at KICT. The dimension of UHPC deck is 2.7 m × 7 m as a precast segment with a typical thickness of deck of only 7 cm. However, harmful crack was observed in the deck at the time of the fabrication of the deck segments. Accordingly, new fabrication method was conceived and applied to prevent cracking of the UHPC slender deck. Four UHPC deck segments were fabricated successfully without any crack. After construction, the dynamic characteristics (natural frequencies and mode shapes) were evaluated through vibration tests since several users felt excess vibration. A vertical tuned mass damper (TMD) was proposed and installed on the parapet of the bridge. The TMD reduces the acceleration by about 30% from 0.0316 g to 0.0244 g when two pedestrians are crossing the bridge. 展开更多
关键词 UHPC PEDESTRIAN CABLE Stayed BRIDGE Dynamic Characteristics Test TMD
下载PDF
Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete 被引量:4
4
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2014年第13期989-999,共11页
Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is perf... Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1]. 展开更多
关键词 Perfobond RIB CONNECTOR Ultra High Performance Concrete Push-Out Test SHEAR Strength
下载PDF
Conceptual Design of Hybrid Cable-Stayed Bridge with Central Span of 1000 m Using UHPC 被引量:3
5
作者 Hyejin Yoon Won Jong Chin +2 位作者 Hee Seok Kim Moon Seoung Keum Young Jin Kim 《Engineering(科研)》 2013年第9期744-750,共7页
Ultra-high performance concrete (UHPC) is featured by a compressive strength 5 times higher than that of ordinary concrete and by a high durability owing to the control of the chloride penetration speed by its dense s... Ultra-high performance concrete (UHPC) is featured by a compressive strength 5 times higher than that of ordinary concrete and by a high durability owing to the control of the chloride penetration speed by its dense structure. The high strength characteristics of UHPC offer numerous advantages like the reduction of the quantities of cables and foundations by the design of a lightweight superstructure in the case of the long-span bridge preserving its structural performance through axial forces and structures governed by compression. This study conducted the conceptual design of a hybrid cable-stayed bridge with central span of 1000 m and exploiting 200 MPa-class UHPC. The economic efficiency of the conceptual design results of the hybrid cable-stayed bridge with central span of 1000 m and of Sutong Bridge, the longest cable-stayed bridge in the world, was analyzed. 展开更多
关键词 Ultra-High Performance Concrete UHPC CABLE-STAYED BRIDGE 200 MPa-Class Sutong BRIDGE
下载PDF
Rolling Fatigue Test of Large-Sized UHPC Member for Cable Stayed Bridge 被引量:2
6
作者 Jeong-Rae Cho Young Jin Kim +2 位作者 Jong Sup Park Eun Suk Choi Won Jong Chin 《Engineering(科研)》 2012年第10期646-654,共9页
Recently, research strives to apply Ultra High Performance Concrete (UHPC) to large-sized structures owing to its remarkable mechanical performance and durability compared to normal concrete. The Korea Institute of Co... Recently, research strives to apply Ultra High Performance Concrete (UHPC) to large-sized structures owing to its remarkable mechanical performance and durability compared to normal concrete. The Korea Institute of Construction Technology proposed SuperBridge800, an edge girder type UHPC cable stayed bridge with central span of 800 m, through its detailed design. The bridge is designed to be erected through the connection of precast UHPC segments. The precast UHPC segment is monolithically composed of one ribbed deck slab and edge girders at each side. The connection between the precast segments is achieved by steel bars at the edge girders and by UHPC cast-in-place wet joint at the slab. Despite of the outstanding mechanical performance of UHPC, the fabrication of large-sized members is a difficult task since UHPC hardens faster than normal concrete and requires a special curing process. Therefore, the constructability of large-sized UHPC segment should be secured to achieve SuperBridge800. Besides, the performance of the connection between segments should also be guaranteed, especially in terms of the fatigue performance of the UHPC cast-in-place joint, which constitutes a weak point. To that goal, two half-scaled UHPC segments are manufactured and the constructability is examined by fabricating a large-sized UHPC member connected with respect to the design conditions. This study conducts rolling fatigue test on the so-fabricated large-sized UHPC member. Rolling fatigue test is carried out up to 2 million cycles considering actual vehicle load at each center and quarter points of the member. The test results confirm that the service limit state is satisfied. 展开更多
关键词 UHPC CABLE Stayed BRIDGE ROLLING FATIGUE Test Large-Sized UHPC MEMBER
下载PDF
A Study on the Characteristics for the Ground Vibration Due to the Travelling Tilting Train 被引量:2
7
作者 Hee Seok Kim 《Engineering(科研)》 2013年第9期729-734,共6页
The development of the tilting train can contribute to solve the economic burden and enhance the transportation means of areas that did not share the benefits of the high speed railway. But the dynamic behavior caused... The development of the tilting train can contribute to solve the economic burden and enhance the transportation means of areas that did not share the benefits of the high speed railway. But the dynamic behavior caused by the interaction between the train and the track as well as the environmental vibrations along the railway should be evaluated to secure the safety of the train and riding comfort. In this paper a study on the characteristics for ground vibration due to the tilting train travelling in the conventional line are carried out. The transmitted load into the ground is computed through a study on the interrelation between the tilting car and the line. This load is applied into the numerical model which is one for the analysis of ground vibration due to the travelling tilting car. The far fields on the numerical model are formed by the absorbing boundary using dashpot, one of the most widely used absorbing boundary in finite element analysis. Using this numerical model, the analysis of the ground vibration characteristics caused by travelling tilting car is performed. From the analysis, it is shown that the transferred load due to the tilting train is larger than that of the conventional train. 展开更多
关键词 GROUND VIBRATION TILTING CAR Absorbing BOUNDARY
下载PDF
A Study on the Flexural Performance of UHPC Precast Deck-Joint Interface by the Exposure of Steel Fiber 被引量:1
8
作者 Kilje Jung Sung Yong Park +2 位作者 Sung Tae Kim Byung-Suk Kim Keunhee Cho 《Engineering(科研)》 2014年第13期1000-1006,共7页
As a solution against the serviceability problem caused by the cracks occurring at the UHPC precast deck-joint interface, this study proposes a method exposing the steel fiber at the interface and evaluates the corres... As a solution against the serviceability problem caused by the cracks occurring at the UHPC precast deck-joint interface, this study proposes a method exposing the steel fiber at the interface and evaluates the corresponding flexural performance of the lap spliced construction joint. After having slowed down the strength development of the concrete placed in the joint of the precast deck by means of a curing retardant, the concrete at the interface is crushed so as to expose the steel fibers and the change in the flexural performance is observed experimentally according to the exposure of the steel fibers. The results show that, even if the ultimate strength and stiffness of the UHPC precast deck including the joint are mostly determined by the arrangement details of the rebar lap splice, the exposure of the steel fibers can secure stable ductile behavior and reduce the width of the cracks generated at the precast deck-joint interface under service load. 展开更多
关键词 Ultra-High Performance Concrete PRECAST DECK System Steel Fiber EXPOSURE Lap-Spliced Connection 4-Point BENDING Test
下载PDF
Experimental Study on the Mechanical Properties of FRP Bars by Hybridizing with Steel Wires 被引量:1
9
作者 Ji-Hyun Hwang Dong-Woo Seo +1 位作者 Ki-Tae Park Young-Jun You 《Engineering(科研)》 2014年第7期365-373,共9页
Many studies on fiber reinforced polymer composite bars, as a substitute for reinforcing bars, have been conducted to solve corrosion of steel in reinforced concrete structures since 1960s’. However, FRP Bars have a ... Many studies on fiber reinforced polymer composite bars, as a substitute for reinforcing bars, have been conducted to solve corrosion of steel in reinforced concrete structures since 1960s’. However, FRP Bars have a lower elastic modulus than steel rebar as a structural component of concrete structures. Material properties with brittleness fracture and low elastic modulus can be improved by combining cheaper steel than carbon or aramid fibers. In this study, prototypes of FRP Bars with inserted steel wires (i.e., “FRP Hybrid Bars”) were developed and their tensile performance was compared depending on the proportion and diameter of steel. The FRP Hybrid Bars were made by dividing them into D13 and D16 according to the diameter and proportion of inserted wires: GFRPs were combined with wires having different diameters of 0.5 mm, 1.0 mm, and 2.0 mm in the proportion of 10%, 30%, 50%, and 70%, respectively. As a result of tensile tests, the elastic modulus of FRP Hybrid Bars were improved as 20% - 190% in comparison with the fully GFRP Bars. 展开更多
关键词 Fiber-Reinforced POLYMER (FRP) FRP Hybrid BAR TENSILE Test Steel WIRE
下载PDF
Deformation Characteristics of Mono Strand Anchor Head 被引量:1
10
作者 Sung Tae Kim Jeong-Rae Cho +2 位作者 Keunhee Cho Sung Yong Park Young-Hwan Park 《Engineering(科研)》 2014年第12期743-749,共7页
This paper investigates experimentally the deformation characteristics of the mono strand anchor head used in prestressed concrete bridge. Since the strains measurable in the anchor head are the axial and hoop strains... This paper investigates experimentally the deformation characteristics of the mono strand anchor head used in prestressed concrete bridge. Since the strains measurable in the anchor head are the axial and hoop strains, the deformation characteristics of the anchor head are examined by measuring these strains at various positions and according to the jacking force exerted on the pre-stressing strand. Moreover, the possibility to estimate the jacking force acting in the tendon based upon the measured strains and the corresponding error are evaluated. 展开更多
关键词 PRESTRESSED Concrete BRIDGE ANCHOR Head MONO STRAND System DEFORMATION Characteristics
下载PDF
Development of Highly Efficient Construction Technologies for Super Long Span Bridge 被引量:1
11
作者 Hee Seok Kim Young Jin Kim +1 位作者 Won Jong Chin Hyejin Yoon 《Engineering(科研)》 2013年第8期629-636,共8页
This paper presents highly efficient cable erection equipments and methods related to the construction of super-long-span bridges, construction technology of high towers and, technology for offshore foundations curren... This paper presents highly efficient cable erection equipments and methods related to the construction of super-long-span bridges, construction technology of high towers and, technology for offshore foundations currently developed through a R&D on accelerated and cost-saving construction technology for long-span cable bridges to secure our international competitiveness. In the field of cable erection technology, AS and PPWS equipments for highly efficient erection of cable longer than 2000 m, world-class clamping bolt tensioning equipment and shape control system for super-long cable are under development. The technologies developed in the domain of construction of towers are tapered slip form system for the construction of 400 m high tower, shape and erection precision control of elevated tower and, lightweight and modular formwork for slip form system. In the domain of foundation construction, remote controlled survey equipment and analysis system for water-depth of 100 m and depth of 50 m, prediction and evaluation technology of optimal load carrying capacity and settlement complying with international standard and, highly efficient hybrid foundation construction technology suitable for ground acceleration of 0.5 g and deep soft soil are currently developed. 展开更多
关键词 AS EQUIPMENT PPWS EQUIPMENT SLIP FORM System Large Scale FOUNDATION
下载PDF
Load Transfer Test of Post-Tensioned Anchorage Zone in Ultra High Performance Concrete 被引量:1
12
作者 Jee-Sang Kim Changbin Joh Yoon-Seok Choi 《Engineering(科研)》 2015年第3期115-128,共14页
Researches on ultra-high performance concrete (UHPC) have been conducted worldwide owing to its outstanding durability and strength performances. The exploitation of the mechanical properties of UHPC will render it po... Researches on ultra-high performance concrete (UHPC) have been conducted worldwide owing to its outstanding durability and strength performances. The exploitation of the mechanical properties of UHPC will render it possible to achieve economic design through substantial reduction in the cross sectional dimensions and simplification in the reinforcement arrangement. This paper investigates experimentally the load transfer in the prestressed concrete anchorage zone. To provide distinctive features of UHPC compared to ordinary concrete, the cross sectional dimensions of the member were reduced and the stress distribution, deformation and cracking pattern of the PS anchorage zone were examined experimentally according to the degree of reinforcement of the members chosen. The distributions of the bursting stress, spalling stress and longitudinal edge stress in the specimens were observed according to the various types of reinforcement. All the specimens satisfied the load-bearing capacity criterion specified by the European ETAG-013 guidelines and their stress distributions were similar to those in the PS anchorages of post-tensioned members applying ordinary concrete. The cracks propagated longitudinally with lengths up to twice the cross sectional dimensions and their width was smaller than when applying ordinary concrete owing to the bridging effect of the steel fibers in UHPC. Accordingly, the exploitation of the high strength of UHPC enabled us to secure the resistance of the anchorage with no need for particular reinforcing devices. 展开更多
关键词 UHPC PS ANCHORAGE Zone Load Transfer TEST BURSTING FORCE SPLITTING FORCE
下载PDF
Behavior Characteristics of Bonded Type Anchorage for CFRP Tendon 被引量:1
13
作者 Jong Sup Park Woo Tai Jung +1 位作者 Jae Yoon Kang Moon Seoung Kum 《Engineering(科研)》 2013年第11期909-918,共10页
This paper examines the shear stress and displacement occurring in CFRP tendons through finite element analysis on the parameters influencing the anchoring performance to evaluate the behavioral characteristics of the... This paper examines the shear stress and displacement occurring in CFRP tendons through finite element analysis on the parameters influencing the anchoring performance to evaluate the behavioral characteristics of the bonded type anchorage for CFRP tendon. The selected parameters are the inner angle of the anchorage barrel, the friction between the barrel and filling material, and the elastic modulus of the filling material. The difference in the behavioral characteristics is examined for each parameter. In view of the analytic results, the shear stress developed in the CFRP tendon reduces with larger inner angle of the barrel and lower elastic modulus of the filling material. However, such combination provokes also the increase of the relative displacement of the CFRP tendon. Especially, slip failure may occur due to the lack of the confining force necessary for the anchorage due to the sudden loss of vertical force brought by the wedge force. The experimental results relative to barrel inner angles of 2° and 4° showed that the specimen with an angle of 2° preserved its anchoring performance up to tensile failure whereas the specimen with an angle of 4°?failed in developing its maximum anchoring performance due to slip failure. 展开更多
关键词 CFRP TENDON PRESTRESSING ANCHORAGE WEDGE
下载PDF
Experimental Study on Innovative Slip Form Method for the Construction of Tapered Concrete Pylon of Long-Span Cable Bridge
14
作者 Hee Seok Kim Young Jin Kim +1 位作者 Won Jong Chin Hyejin Yoon 《Engineering(科研)》 2014年第10期633-643,共11页
The construction of the three-dimensionally shaped pylons higher than 400 m requires a very high technological degree. It is known that the application of the tapered slip form method for the erection of the concrete ... The construction of the three-dimensionally shaped pylons higher than 400 m requires a very high technological degree. It is known that the application of the tapered slip form method for the erection of the concrete pylon of long-span cable bridges offers the advantage of being significantly faster than applying the auto-climbing system (ACS) form method. Therefore, this study presents the development of an innovative slip form system for pylons with tapered cross-section. Surface wave inspection system is applied for the determination of slip-up time, wireless hydraulic control system is applied for auto rising, GPS system is used to manage the pylon configuration, and lightweight GFRP (Grass Fiber Reinforced Plastic) panels are applied in the slip form system. Small-scale tests were conducted three times to validate the performance of the developed core technologies, and full-scale tests were conducted twice to validate and verify the developed innovative slip form. The full-scale tapered concrete pylons have hollow shafts and a height of 10 m. The sectional dimensions are varied according to the construction height. The experimental constructions of the tapered pylons using the innovative slip form were conducted successfully. This system is the world’s first application of GFRP slip form panel. 展开更多
关键词 SLIP Form SYSTEM Surface Wave Inspection SYSTEM Wireless Hydraulic Control SYSTEM PYLON Configuration LIGHTWEIGHT GFRP Panel
下载PDF
Enhancement in Elastic Modulus of GFRP Bars by Material Hybridization
15
作者 Dong-Woo Seo Ki-Tae Park +1 位作者 Young-Jun You Hyeong-Yeol Kim 《Engineering(科研)》 2013年第11期865-869,共5页
Fiber reinforced polymer (FRP) reinforcing bars for concrete structure has been extensively investigated for last two decades and a number of FRP bars are commercially available. However, one of shortcomings of the ex... Fiber reinforced polymer (FRP) reinforcing bars for concrete structure has been extensively investigated for last two decades and a number of FRP bars are commercially available. However, one of shortcomings of the existing FRP bars is its low elastic modulus, if glass fibers are used (i.e., GFRP). The main objective of this study using the concept of material hybridization is to develop a viable hybrid FRP bar for concrete structures, especially for marine and port con- crete structures. The purposes of hybridization are to increase the elastic modulus of GFRP bar with acceptable tensile strength. Two types of hybrid GFRP bar were considered in the development: GFRP crust with steel core and GFRP bar with steel wires dispersed over the cross-section. Using E-glass fibers and unsaturated polyester resins, the hybrid GFRP bar samples of 13 mm in diameter were pultruded and tested for tensile properties. The effect of hybridization on tensile properties of GFRP bars was evaluated by comparing the results of tensile test with those of non-hybrid GFRP bars. The results of this study indicated that the elastic modulus of the hybrid GFRP bar was increased by up to 270 percent by the material hybridization. The results of the test and the future recommendations are summarized in this paper. To ensure long-term durability of the hybrid GFRP bars in waterfront structure applications, the individual and combined effects of environmental conditions on hybrid GFRP rebar itself as well as on the interface between rebar and concrete should be accessed. 展开更多
关键词 FRP Glass Fibers TENSILE Test ELASTIC MODULUS PULTRUSION MATERIAL HYBRIDIZATION Marine Structures
下载PDF
A Study on the Characteristics and the Effective Reduction Methods for the Ground Vibration Due to the Travelling Tilting Train
16
作者 Hee Seok Kim 《Engineering(科研)》 2014年第4期202-209,共8页
In this paper, a study on the characteristics and the reduction methods of ground vibration due to the tilting train travelling in the conventional line is carried out. The load transmitted into the ground is computed... In this paper, a study on the characteristics and the reduction methods of ground vibration due to the tilting train travelling in the conventional line is carried out. The load transmitted into the ground is computed considering the interaction between the tilting car and the line. This load is then applied in the numerical model for the analysis of ground vibration due to the travelling tilting car. The far-fields of the numerical model are modeled using the dashpot, as one of the most widely used absorbing boundaries in finite element analysis. Using this numerical model, the analysis of the ground vibration characteristics caused by the travelling tilting car and the analysis of the blocking effect of the ground vibration by wave barriers are performed. From the numerical analysis, it is shown that the blocking effect of the trench and the barrier filled with soft material is more effective than that of the barrier filled with hard material. 展开更多
关键词 Component GROUND Vibration TILTING CAR Absorbing BOUNDARY Wave BARRIER
下载PDF
Load-Measuring Pot Bearing with Built-In Load Cell —Part II: Fatigue Performance and Experimental Temperature Correction
17
作者 Jeong-Rae Cho Young Jin Kim +3 位作者 Jong-Won Kwark Sung Yong Park Won Jong Chin Byung-Suk Kim 《Engineering(科研)》 2013年第11期881-886,共6页
This paper presents the results of fatigue performance tests performed up to 10 million cycles on a load-measuring pot bearing with built-in load cell to verify its field applicability and proposes an empirical temper... This paper presents the results of fatigue performance tests performed up to 10 million cycles on a load-measuring pot bearing with built-in load cell to verify its field applicability and proposes an empirical temperature correction formula. In Part I of this work, various measurement performances of the load-measuring pot bearing were evaluated through static and dynamic loading tests. Bridge bearings are subjected to the effect of fatigue caused by the repeated application of moving loads and exposed to harsh site conditions including cold and hot weathers differently to laboratory conditions. Accordingly, the durability of the load-measuring pot bearing with built-in load cell shall be secured and the environmental effects like temperature shall be minimized for its application on field. This study conducted fatigue tests up to 10 million cycles on a load-measuring pot bearing with the capacity of 1000 kN to examine eventual degradation of the measurement accuracy with respect to the number of fatigue loading cycles. In addition, the experimental temperature correction procedure is proposed to obtain the temperature correction formula enabling to correct the effect of temperature on the load measurement. 展开更多
关键词 POT BEARING Load-Measuring LOAD Cell FATIGUE Temperature Correction
下载PDF
Parametric Analysis on the Optimal Dimensions of Steel Sleeve in Swaging Type Anchorage for CFRP Tendon
18
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Kum 《Engineering(科研)》 2013年第11期902-908,共7页
This paper presents the parametric analysis conducted to derive the optimal dimensions of the steel sleeve necessary to secure the bond performance of the swaging type anchorage for CFRP tendon with diameter of 5 mm. ... This paper presents the parametric analysis conducted to derive the optimal dimensions of the steel sleeve necessary to secure the bond performance of the swaging type anchorage for CFRP tendon with diameter of 5 mm. To that goal, finite element analysis is performed on the parameters determining the dimensions of the sleeve like the thickness and inner diameters of the sleeve. The results show that a constant swaging pressure of about 450 MPa on the mean is distributed in the sleeve when the thickness ratio of the stress relief zone to the effective swaging zone of the sleeve is larger than 1.1 and that the swaging pressure tends to reduce linearly as much as this thickness ratio becomes smaller than 1.1. The pressure varies within a range of about 30% according to the change in the inner diameter of the sleeve whereas varies within a range less than 10% according to the change in the inner diameter when the thickness ratio is larger than 1.1. Finally, the optimal dimensions of the steel tube sleeve enabling to secure an anchor force larger than the rupture strength of the CFRP tendon with diameter of 5 mm are determined based upon the results of the parametric analysis. 展开更多
关键词 CFRP TENDON PRESTRESSING SWAGING Type ANCHORAGE SWAGING SLEEVE
下载PDF
Comparison of Measured and Dynamic Analysis Vertical Accelerations of High-Speed Railway Bridges Crossed by KTX Train
19
作者 Hyejin Yoon Won Jong Chin +2 位作者 Jeong-Rae Cho Jae Yoon Kang Jongwon Kwark 《Engineering(科研)》 2013年第9期756-763,共8页
Since high-speed railway bridges are subjected to cyclic loading by the continuous wheel loads traveling at high speed and regular spacing, their dynamic behavior is of extreme importance and has significant influence... Since high-speed railway bridges are subjected to cyclic loading by the continuous wheel loads traveling at high speed and regular spacing, their dynamic behavior is of extreme importance and has significant influence on the riding safety of the trains. To secure the riding safety of the trains, advanced railway countries have limited the vertical acceleration of the bridge slab below critical values at specific frequency domains. Since these limitations of the vertical acceleration constitute the most important factors in securing the dynamic safety of the bridges, these countries have opted for a conservative approach. However, the Korean specifications limit only the size of the peak acceleration without considering the frequency domain, which impede significantly rational evaluation of the high-speed railway bridges in Korea. In addition, the evaluation of the acceleration without consideration of the frequency domain is the cause of disagreement between the dynamic analysis and measurement results. This study conducts field monitoring and dynamic analysis on high-speed railway bridges to gather the acceleration signals and compare them. Significant difference in the size of the vertical acceleration was observed between the measured and dynamic analysis accelerations when discarding the frequency domain as done in the current specifications. The comparison of the accelerations considering only low frequencies below 30 Hz showed that the dynamic analysis reflected accurately the measured vertical acceleration. 展开更多
关键词 HIGH-SPEED RAILWAY Bridge Vertical ACCELERATION Dynamic Response
下载PDF
Computation of Impact Factor of High-Speed Railway Bridge by KTX Train Riding Test
20
作者 Hyejin Yoon Won Jong Chin +2 位作者 Jae Yoon Kang Jongwon Kwark Eui-Seung Hwang 《Engineering(科研)》 2013年第9期751-755,共5页
The design live load of railway is divided into common railway and high-speed railway separately inKorea. Accordingly, the Korean design specification of railway specifies the impact factor for common railway and high... The design live load of railway is divided into common railway and high-speed railway separately inKorea. Accordingly, the Korean design specification of railway specifies the impact factor for common railway and high-speed railway respectively. The impact factor for high-speed railway is based on Eurocode. Since the impact factor criteria inKoreawere established by adopting those of the Eurocode and without dedicated investigation relying on research results reflecting the domestic circumstances, thorough examination should be implemented on these criteria. Therefore the evaluation of impact factor based on field tests is required. Both dynamic and static vertical displacements are necessary to compute the impact factor. The dynamic response can be obtained from the measurement of deflection of the bridge slab crossed by the firstKoreahigh-speed train (KTX, Korea Train eXpress) running at high-speed. The main difficulties encountered are in obtaining static response because static response corresponds to the response of the bridge when the train remains immobile on the bridge or crosses the bridge at speed slower than5 km/hr. This study introduces the static response derived by applying the moving average method on the dynamic response signal. To that goal, field measurements was conducted under train speeds of5 km/hr and ranging from100 km/hr to300 km/hr on Yeonjae Bridge located in the trial section of the Gyeonbu High-Speed Railway Line before its opening. The validity of the application of the moving average method is verified from comparison of measured static response and derived static response by moving average method. Moreover, evaluation is conducted on the impact factor computed for a bridge crossed by the KTX train running at operational speed. 展开更多
关键词 HIGH-SPEED RAILWAY Dynamic Response Impact Factor MOVING AVERAGE Method
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部